Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Endoscopy ; 40(8): 670-4, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18561105

RESUMO

BACKGROUND AND STUDY AIMS: Changes in portal pressure during endoscopy have not been previously evaluated. The aims of this study were to assess the effect of esophagogastroduodenoscopy (EGD), colonoscopy, and endoscopic retrograde cholangiopancreatography (ERCP) on portal vein, inferior vena cava (IVC), and systemic pressures. PATIENTS AND METHODS: Five acute experiments were performed on 50-kg pigs utilizing endoscopic ultrasound (EUS)-guided catheterization of the portal vein and IVC. Systemic, intra-abdominal, IVC, and portal vein pressures were monitored during colonoscopy, EGD, and ERCP with endoscopic sphincterotomy. After endoscopy the animals were sacrificed for necropsy. The main outcome measure was pressure change during each type of endoscopic procedure. RESULTS: There were no significant changes in heart rate or systemic pressure during all endoscopic procedures. Intra-abdominal pressure increased during colonoscopy ( P = 0.02) and ERCP ( P = 0.007). However, mean portal venous pressure was significantly elevated only after the injection of contrast into the common bile duct, reaching its peak value at the time of biliary sphincterotomy (39.0 +/- 15.2 mm Hg vs. 13.4 +/- 3.6 mm Hg at baseline, P = 0.006). Mean peak IVC pressure was also elevated during ERCP, but it did not reach statistical significance (24.0 +/- 10.7 mm Hg vs. 12.6 +/- 4.1 mm Hg at baseline, P = 0.06). CONCLUSION: EGD and colonoscopy did not cause significant changes in portal vein, IVC, or systemic pressures. ERCP with biliary sphincterotomy increased portal pressure with only limited effect on IVC and systemic pressures. These new data indicate a possible connection between ERCP with sphincterotomy and portal pressure, and may be clinically important for patients with liver disease and other causes of portal hypertension who undergo this procedure.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Colonoscopia , Endoscopia do Sistema Digestório , Hipertensão Portal/etiologia , Animais , Biópsia por Agulha Fina/instrumentação , Cateterismo , Modelos Animais , Veia Porta , Punções , Suínos , Ultrassonografia de Intervenção , Veia Cava Inferior
3.
Endoscopy ; 40(6): 506-12, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18478511

RESUMO

BACKGROUND AND STUDY AIMS: Pancreatitis complicates 1% - 22% of endoscopic retrograde cholangiopancreatography procedures. The study aims were to develop a reproducible animal model of post-ERCP pancreatitis (PEP), and investigate the impact of endoscopic technique on severity of PEP. PATIENTS AND METHODS: ERCP was carried out in six male hound dogs. Pancreatitis was induced by one of three escalating methods: 1) pancreatic acinarization with 20 - 30 mL of contrast; 2) acinarization + ductal balloon occlusion + sphincterotomy; 3) acinarization + intraductal synthetic bile injection + ductal balloon occlusion + sphincterotomy. Dogs 5 and 6 received a pancreatic stent. Necropsy was performed on postoperative day 5. All pancreatic specimens were graded by two blinded pathologists according to a validated scoring system. All dogs were compared with three control dogs. RESULTS: Dogs 1 - 4 developed clinical pancreatitis and hyperamylasemia (11 736 vs. 722 U/L, P = 0.02). Total injury scores were significantly elevated compared with controls (6.85 vs. 1.06, P = 0.004). There was significant increase in acinar cell necrosis (0.86 vs. 0.06, P = < 0.001), and all other categories (except fibrosis) demonstrated elevated injury scores . Dogs 5 and 6 developed clinical pancreatitis without significant hyperamylasemia; total injury scores were elevated compared with controls (4.83 vs. 1.06, P = 0.01), but lower than in Dogs 1 - 4 (4.83 vs. 6.85, P = 0.25). There was escalating severity of pancreatic injury from Dogs 1 to 4 correlating with the method of endoscopic injury used. CONCLUSION: Severity of PEP is directly proportional to invasiveness of endoscopic intervention. Pancreatic acinarization, even without balloon occlusion and sphincterotomy, can be used as a reliable animal model for future studies investigating therapy and prevention of disease.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Pancreatite/etiologia , Pancreatite/patologia , Doença Aguda , Animais , Biópsia por Agulha , Modelos Animais de Doenças , Cães , Imuno-Histoquímica , Masculino , Testes de Função Pancreática , Probabilidade , Distribuição Aleatória , Valores de Referência , Reprodutibilidade dos Testes , Medição de Risco , Índice de Gravidade de Doença
4.
Surg Endosc ; 22(7): 1609-13, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18401658

RESUMO

BACKGROUND: Reliable closure of the translumenal incision is one of the main challenges facing natural orifice translumenal endoscopic surgery (NOTES). This study aimed to evaluate the use of an automated flexible stapling device (SurgASSIST) for closure of the gastrotomy incision in a porcine model. METHODS: A double-channel gastroscope was advanced into the stomach. A gastric wall incision was made, and the endoscope was advanced into the peritoneal cavity. After peritoneoscopy, the endoscope was withdrawn into the stomach. The SurgASSIST stapler was advanced orally into the stomach. The gastrotomy edges were positioned between the opened stapler arms using two endoscopic grasping forceps. Stapler loads with and without a cutting blade were used for gastric closure. After firing of the stapler to close the gastric wall incision, x-ray with contrast was performed to assess for gastric leakage. At the end of the procedure, the animals were killed for a study of closure adequacy. RESULTS: Four acute animal experiments were performed. The delivery and positioning of the stapler were achieved, with technical difficulties mostly due to a short working length (60 cm) of the device. Firing of the staple delivered four rows of staples. Postmortem examination of pig 1 (when a cutting blade was used) demonstrated full-thickness closure of the gastric wall incision, but the cutting blade caused a transmural hole right at the end of the staple line. For this reason, we stopped using stapler loads with a cutting blade. In the three remaining animals (pigs 2-4), we were able to achieve a full-thickness closure of the gastric wall incision without any complications. CONCLUSIONS: The flexible stapling device may provide a simple and reliable technique for lumenal closure after NOTES procedures. Further survival studies are currently under way to evaluate the long-term efficacy of gastric closure with the stapler after intraperitoneal interventions.


Assuntos
Gastroscopia/métodos , Gastrostomia/instrumentação , Suturas , Animais , Desenho de Equipamento , Grampeamento Cirúrgico/métodos , Suínos
5.
Endoscopy ; 39(10): 849-53, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17968798

RESUMO

BACKGROUND AND STUDY AIMS: Safe entrance into the peritoneal cavity through the gastric wall is paramount for the successful clinical introduction of natural orifice transluminal endoscopic surgery (NOTES). The aim of the study was to develop alternative safe transgastric access to the peritoneal cavity. PATIENTS AND METHODS: We performed 11 survival experiments on 50-kg pigs. In sterile conditions, the abdominal wall was punctured with a Veress needle. The peritoneal cavity was insufflated with 2 L carbon dioxide (CO (2)). A sterile endoscope was introduced into the stomach through a sterile overtube; the gastric wall was punctured with a needle-knife; after balloon dilation of the puncture site, the endoscope was advanced into the peritoneal cavity. Peritoneoscopy with biopsies from abdominal wall, liver and omentum, was performed. The endoscope was withdrawn into the stomach. The animals were kept alive for 2 weeks and repeat endoscopy was followed by necropsy. RESULTS: The pneumoperitoneum, easily created with the Veress needle, lifted the abdominal wall and made a CO (2)-filled space between the stomach and adjacent organs, facilitating gastric wall puncture and advancement of the endoscope into the peritoneal cavity. There were no hemodynamic changes or immediate or delayed complications related to pneumoperitoneum, transgastric access, or intraperitoneal manipulations. Follow-up endoscopy and necropsy revealed no problems or complications inside the stomach or peritoneal cavity. CONCLUSIONS: Creation of a preliminary pneumoperitoneum with a Veress needle facilitates gastric wall puncture and entrance into the peritoneal cavity without injury to adjacent organs, and can improve the safety of NOTES.


Assuntos
Laparoscópios , Laparoscopia/métodos , Cavidade Peritoneal/cirurgia , Pneumoperitônio Artificial/métodos , Estômago/cirurgia , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Seguimentos , Gastroenteropatias/cirurgia , Projetos Piloto , Suínos
6.
Endoscopy ; 39(10): 876-80, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17968803

RESUMO

BACKGROUND AND STUDY AIMS: Reliable closure of the transluminal incision is the crucial step for natural orifice transluminal endoscopic surgery (NOTES) procedures. The aim of this study was to evaluate the feasibility and effectiveness of transgastric access closure with a flexible stapling device in a porcine survival model. PATIENTS AND METHODS: We carried out four experiments (two sterile and two nonsterile) on 50 kg pigs. The endoscope was passed through a gastrotomy made with a needle knife and an 18-mm controlled radial expansion dilating balloon. After peritoneoscopy, a flexible linear stapling device (NOLC60, Power Medical Interventions, Langhorne, Pennsylvania, USA) was perorally advanced over a guide wire into the stomach, positioned under endoscopic guidance, and opened to include the site of gastrotomy between its two arms; four rows of staples were fired. One animal was sacrificed 24 hours after the procedure (progression of pre-existing pneumonia). The remaining animals were survived for 1 week and then underwent repeat endoscopy and postmortem examination. RESULTS: Peroral delivery and positioning of the stapling device involved some technical difficulties, mostly due to the short length (60 cm) of the stapling device. The stapler provided complete leak-resistant gastric closure in all pigs. None of the surviving animals had any clinical signs of infection. Necropsy demonstrated an intact staple line with full-thickness healing of the gastrotomy in all animals. Histologic examination confirmed healing, but also revealed intramural micro-abscesses within the gastric wall after nonsterile procedure. CONCLUSIONS: Gastrotomy closure with a perorally delivered flexible stapling device created a leak-resistant transmural line of staples followed by full-thickness healing of the gastric wall incision. Increasing the length of the instrument and adding device articulation will further facilitate its use for NOTES procedures.


Assuntos
Endoscopia Gastrointestinal/métodos , Doenças Peritoneais/cirurgia , Estômago/cirurgia , Grampeadores Cirúrgicos , Técnicas de Sutura/instrumentação , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Estudos de Viabilidade , Projetos Piloto , Resultado do Tratamento
7.
Endoscopy ; 39(9): 761-4, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17703382

RESUMO

BACKGROUND AND STUDY AIMS: The most permanent method of treating achalasia is a surgical myotomy. Because of the requirement for a mucosal incision and the risk of perforation, this procedure has not generally been approached endoscopically. We hypothesized that we could perform a safe and robust myotomy by working in the submucosal space, accessed from the esophageal lumen. MATERIALS AND METHODS: Four pigs were used for this experiment. Baseline lower esophageal sphincter (LES) pressures were recorded and the pigs underwent upper endoscopy using a standard endoscope. A submucosal saline lift was created approximately 5 cm above the LES and a small nick was made in the mucosa in order to facilitate the introduction of a dilating balloon. After dilation, the scope was introduced over the balloon into the submucosal space and advanced toward the now visible fibers of the LES. The circular layer of muscle was then cleanly incised using an electrocautery knife in a distal-to-proximal fashion, without complications. The scope was then withdrawn back into the lumen and the mucosal defect was closed with endoscopically applied clips. The entire procedure took less than 15 minutes. Manometry was repeated on day 5 after the procedure and the animals were euthanized on day 7. RESULTS: LES pressures fell significantly from an average of 16.4 mm Hg to an average of 6.7 mm Hg after the myotomy. The necropsy examinations revealed no evidence of mediastinitis or peritonitis. CONCLUSIONS: Endoscopic submucosal esophageal myotomy is feasible, safe, and effective in the short term. It has the potential for being useful in patients with achalasia. The submucosal space is a novel and potentially important field of operation for endoscopic procedures.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório/métodos , Acalasia Esofágica/cirurgia , Animais , Esfíncter Esofágico Inferior , Esofagoscopia , Esôfago/cirurgia , Estudos de Viabilidade , Manometria , Modelos Animais , Mucosa/cirurgia , Músculos/cirurgia , Suínos
8.
Surg Endosc ; 21(8): 1450-3, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17593460

RESUMO

BACKGROUND: The peroral transluminal approach to the peritoneal cavity appears safe, feasible, and may further reduce the invasiveness of surgery. However, flexible endoscopes have multiple limitations inside the peritoneal cavity, which can potentially be overcome by blending the use of both a laparoscope and a flexible upper endoscope--a hybrid approach. The goal of the present study was to evaluate a hybrid minimally invasive technique for cholecystectomy in a porcine model. METHODS: Hybrid cholecystectomies were performed in acute experiments on 50-kg pigs under general anesthesia. Pneumoperitoneum was created with a Veress needle, and a laparoscopic 10-mm port was inserted. Under laparoscopic observation, the gastric wall incision was done with an endoscopic needle-knife and sphincterotome, and the upper endoscope was advanced into the peritoneal cavity. A laparoscopic 10-mm port was inserted into the right upper quadrant of the abdomen for gallbladder traction to facilitate exposure of the cystic duct and artery. Via the biopsy channel of the flexible endoscope, and using a knife with an isolated tip, a needle knife, and clips, both the cystic duct and artery were identified, clipped, and transected. The gallbladder itself was then dissected and retracted through the mouth, and the gastric wall incision was closed with endoscopic clips. RESULTS: Five hybrid cholecystectomies were performed without complications. The laparoscopic port enabled a stable pneumoperitoneum, good traction and counter-traction, and improved spatial orientation and visualization. Necropsy did not reveal any intraperitoneal complications. CONCLUSIONS: The hybrid approach increases safety of initial gastric puncture and gastric wall incision, improves orientation and navigation of the flexible endoscope inside the peritoneal cavity, simplifies peroral transgastric cholecystectomy, and could be used to decrease invasiveness of laparoscopic surgery and to facilitate development and clinical introduction of transgastric endoscopic procedures. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00464-007-9329-2) contains supplementary material, which is available to authorized users.


Assuntos
Colecistectomia Laparoscópica/métodos , Colecistectomia/métodos , Animais , Endoscópios , Gastrostomia , Sus scrofa
9.
Endoscopy ; 39(6): 525-9, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17554648

RESUMO

BACKGROUND AND STUDY AIMS: Pancreatic ablation is gaining popularity for the treatment of focal pancreatic lesions. The aim of our study was to evaluate local effects of intrapancreatic alcohol injection and the utility of contrast-enhanced endoscopic ultrasound (EUS) for its monitoring in a porcine model. METHODS: We performed four survival experiments on 50-kg pigs. Under linear EUS guidance, 0.5 mL of 50% ethanol plus purified carbon particle solution (GI Spot) was injected into the pancreatic body to create a focal area of pancreatic necrosis. The animals survived for 24-48 hours (pigs # 1, # 2, and # 3) and 7 days (pig # 4). EUS was then repeated with and without perflutren lipid microspheres (Definity) administration through the peripheral vein. Standard and microsphere-enhanced images of the pancreas were compared. Afterwards the animals were euthanized for necropsy. RESULTS: Alcohol injection caused focal pancreatic necrosis, which was barely seen by standard EUS as a subtle hypoechoic lesion 1 cm in diameter. Color and power Doppler EUS of this region did not reveal any blood flow. After intravenous injection of microspheres, color Doppler EUS revealed marked contrast enhancement of normal pancreatic parenchyma with a clearly delineated avascular alcohol-treated area, which on postmortem examination corresponded to the discrete necrotic area marked with carbon particles. CONCLUSIONS: EUS-guided alcohol injection consistently causes focal areas of pancreatic necrosis. Contrast-enhanced EUS with microspheres improves visualization of altered pancreatic vascular perfusion and can be used to facilitate detection of small pancreatic lesions and its follow-up post-ablation.


Assuntos
Cáusticos/administração & dosagem , Meios de Contraste/administração & dosagem , Endossonografia , Etanol/administração & dosagem , Pâncreas/diagnóstico por imagem , Animais , Modelos Animais de Doenças , Aumento da Imagem , Injeções Intralesionais , Injeções Intravenosas , Microesferas , Necrose , Pâncreas/patologia , Projetos Piloto , Suínos
10.
Endoscopy ; 39(5): 390-3, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17516343

RESUMO

BACKGROUND AND STUDY AIMS: Multiple studies have demonstrated the feasibility of peroral transgastric endoscopic procedures in animal models. The aim of the study was to evaluate the feasibility of a peroral transgastric endoscopic approach to repair abdominal wall hernias. PATIENTS AND METHODS: We performed acute experiments under general anesthesia with endotracheal intubation using 50-kg pigs. Following peroral intubation an incision of the gastric wall was made and the endoscope was advanced into the peritoneal cavity. An internal anterior abdominal wall incision was performed with a needle knife to create an animal model of a ventral hernia. After hernia creation an endoscopic suturing device was used for primary repair of the hernia. After completion of the hernia repair the endoscope was withdrawn into the stomach and the gastric wall incision was closed with endoscopic clips. Then the animals were killed for necropsy. RESULTS: Two acute experiments were performed. Incision of the gastric wall was easily achieved with a needle knife and a pull-type sphincterotome. A large (3 x 2 cm) defect of the abdominal wall (ventral hernia model) was closed with five or six sutures using the endoscopic suturing device. Postmortem examination revealed complete closure of the hernia without any complications. CONCLUSIONS: Transgastric endoscopic primary repair of ventral hernias in a porcine model is feasible and may be technically simpler than laparoscopic surgery.


Assuntos
Endoscopia do Sistema Digestório/métodos , Hérnia Abdominal/cirurgia , Animais , Modelos Animais de Doenças , Estudos de Viabilidade , Intubação/métodos , Suínos
11.
Surg Endosc ; 21(6): 998-1001, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17404796

RESUMO

BACKGROUND: The peroral transgastric endoscopic approach for intraabdominal procedures appears to be feasible, although multiple aspects of this approach remain unclear. This study aimed to measure intraperitoneal pressure in a porcine model during the peroral transgastric endoscopic approach, comparing an endoscopic on-demand insufflator/light source with a standard autoregulated laparoscopic insufflator. METHODS: All experiments were performed with 50-kg female pigs under general anesthesia. A standard upper endoscope was advanced perorally through a gastric wall incision into the peritoneal cavity. The peritoneal cavity was insufflated with operating room air from an endoscopic light source/insufflator. Intraperitoneal pressure was measured by three routes: (1) through the endoscope biopsy channel, (2) through a 5-mm transabdominal laparoscopic port, and (3) through a 16-gauge Veress needle inserted into the peritoneal cavity through the anterior abdominal wall. The source of insufflation alternated between on-demand manual insufflation through the endoscopic light source/insufflator using room air and a standard autoregulated laparoscopic insufflator using carbon dioxide (CO(2)). RESULTS: Six acute experiments were performed. Intraperitoneal pressure measurements showed good correlation regardless of measurement route and were independent of the type of insufflation gas, whether room air or CO(2). On-demand insufflation with the endoscopic light source/insufflator resulted in a wide variation in pressures (range, 4-32 mmHg; mean, 16.0 +/- 11.7). Intraabdominal pressures using a standard autoregulated laparoscopic insufflator demonstrated minimal fluctuation (range, 8-15 mmHg; mean, 11.0 +/- 2.2 mmHg) around a predetermined value. CONCLUSION: Use of an on-demand unregulated endoscopic light source/insufflator for translumenal surgery can cause large variation in intraperitoneal pressures and intraabdominal hypertension, leading to the risk of hemodynamic and respiratory compromise. Safety may favor well-controlled intraabdominal pressures achieved with a standard autoregulated laparoscopic insufflator.


Assuntos
Gastroscópios , Laparoscópios , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Cavidade Peritoneal/cirurgia , Pneumoperitônio Artificial/instrumentação , Animais , Feminino , Modelos Animais , Pressão , Estômago/cirurgia , Suínos
12.
Endoscopy ; 39(1): 72-6, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17252464

RESUMO

BACKGROUND AND STUDY AIMS: Implantable microstimulators (IMS) have been used in a variety of medical conditions. Selective stimulation to increase lower esophageal sphincter (LES) pressure may be useful in the control of gastroesophageal reflux disease. We evaluated on-demand stimulation of the LES with an endoscopically implanted microstimulator. MATERIALS AND METHODS: We performed acute experiments in three 30-kg dogs. After LES manometry, a 3.3 mm x 28 mm microstimulator (the Bion) was implanted into the LES. Manometry was repeated with and without IMS stimulation to record the changes in LES pressure. Stimulation amplitude was varied from 3 mA to 10 mA, with a fixed frequency of 20 Hz and a pulse width of 200 microsec. RESULTS: The mean LES pressures prior to IMS implantation in the three dogs were 13.0 mm Hg, 5.0 mm Hg, and 14.9 mm Hg. The mean pressures were not significantly changed by IMS placement. There were no documented changes in LES pressure when the amplitude of stimulation was less than 8 mA. After stimulation of the IMS at a setting of 10 mA in dogs 1 and 2 and at 8mA in dog 3, however, the resultant LES pressures were 62.1 mm Hg, 35.1 mm Hg, and 26.8 mm Hg respectively, more than three times higher than post-implantation baseline levels (P < 0.02). CONCLUSIONS: The LES pressure can be increased using an on-demand microstimulator. The implantation procedure is minimally invasive, represents a novel therapeutic approach to gastroesophageal reflux disease, and may have therapeutic potential for other gastrointestinal motility disorders.


Assuntos
Terapia por Estimulação Elétrica , Eletrodos Implantados , Esfíncter Esofágico Inferior/fisiologia , Robótica , Animais , Cães , Esofagoscopia , Manometria , Modelos Animais , Implantação de Prótese
13.
Endoscopy ; 38(12): 1230-4, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17163324

RESUMO

BACKGROUND AND STUDY AIMS: Creation of a submucosal cushion before endoscopic mucosal resection (EMR) significantly reduces perforation risk. We evaluated six solutions as cushioning agents in live pigs. MATERIAL AND METHODS: 5 ml of normal saline, normal saline plus epinephrine, albumin 12.5 %, albumin 25 %, hydroxypropyl methylcellulose, and the pig's own whole blood were endoscopically injected into the porcine esophageal submucosa. Blood was obtained from a peripheral vein immediately before injection. Injections were made every 4 cm from the gastroesophageal junction. The time from completion of the injection to disappearance of the cushion was recorded. Endoscopy was repeated at 48 hours post injection. Two EMRs were performed after blood injection. Statistical analysis employed one-way analysis of variance followed by pairwise T test comparisons using the Bonferroni correction. RESULTS: Five animal experiments were completed. The mean time to dissipation of the submucosal cushion was shortest for saline plus epinephrine sites (2.87 minutes, SD 2.21) followed by the saline (4.8 minutes, SD 1.56), albumin 12.5 % (5.68 minutes, SD 3.48), albumin 25 % (7.83 minutes, SD 2.02), hydroxypropyl methylcellulose (9.77 minutes, SD 1.55), and blood sites (38.6 minutes, SD 6.07). Injection of blood resulted in significantly longer mucosal elevation than any other solution ( P < 0.0007). Blood from the cushion did not hamper visualization and facilitated EMR. CONCLUSION: Blood produces the most durable cushion compared with standard agents, also having the advantages of being readily available and without cost. Albumin 25 % provides as durable a cushion as hydroxypropyl methylcellulose.


Assuntos
Transfusão de Sangue Autóloga/métodos , Mucosa , Albuminas/administração & dosagem , Animais , Esôfago , Derivados da Hipromelose , Injeções , Metilcelulose/administração & dosagem , Metilcelulose/análogos & derivados , Modelos Animais , Suínos , Fatores de Tempo
14.
Surg Endosc ; 20(3): 522-5, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16432652

RESUMO

BACKGROUND: We have previously reported the feasibility of diagnostic and therapeutic peritoneoscopy including liver biopsy, gastrojejunostomy, and tubal ligation by an oral transgastric approach. We present results of per-oral transgastric splenectomy in a porcine model. The goal of this study was to determine the technical feasibility of per-oral transgastric splenectomy using a flexible endoscope. METHODS: We performed acute experiments on 50-kg pigs. All animals were fed liquids for 3 days prior to procedure. The procedures were performed under general anesthesia with endotracheal intubation. The flexible endoscope was passed per orally into the stomach and puncture of the gastric wall was performed with a needle knife. The puncture was extended to create a 1.5-cm incision using a pull-type sphincterotome, and a double-channel endoscope was advanced into the peritoneal cavity. The peritoneal cavity was insufflated with air through the endoscope. The spleen was visualized. The splenic vessels were ligated with endoscopic loops and clips, and then mesentery was dissected using electrocautery. RESULTS: Endoscopic splenectomy was performed on six pigs. There were no complications during gastric incision and entrance into the peritoneal cavity. Visualization of the spleen and other intraperitoneal organs was very good. Ligation of the splenic vessels and mobilization of the spleen were achieved using commercially available devices and endoscopic accessories. CONCLUSIONS: Transgastric endoscopic splenectomy in a porcine model appears technically feasible. Additional long-term survival experiments are planned.


Assuntos
Endoscopia/métodos , Esplenectomia/métodos , Animais , Modelos Animais , Baço/irrigação sanguínea , Estômago/cirurgia , Suínos
15.
Endoscopy ; 37(9): 847-51, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16116536

RESUMO

BACKGROUND: Existing animal models of ulcerative bleeding are not suitable for endoscopic investigation. We describe a new porcine model of massive arterial bleeding in the stomach and its use for assessing a novel endoscopic suturing device. METHODS: Two animal models were investigated. In model 1, the short gastric artery (mean diameter 2 mm) was divided near its gastric end. A mucosal defect was created near the greater curve and the divided artery was brought into the lumen of the stomach through a submucosal tunnel. An inflatable plastic cuff was placed around the base of the artery. Cuff deflation led to massive bleeding. In model 2, the short gastric artery was carefully exposed along a segment of 2 cm on the side facing the stomach. It was then anchored to a small gastrostomy made at the posterior wall near the vessel. At endoscopy an ulcer-like lesion could be seen with a pulsatile vessel at the base and brisk bleeding could be started by cutting a hole in the artery using endoscissors. The pigs were heparinized by an intravenous bolus of 110-300 units per kilogram, in both models. A prototype suturing device, the Eagle Claw, was inserted using a gastroscope and the curved needle was driven around the bleeding artery. Extracorporeal knotting or intracorporeal ligation was done endoscopically. RESULTS: Pulsatile arterial bleeding was successfully created in four pigs using model 1, and in another four pigs using model 2. Model 2 was more reproducible and less time-consuming to create. Endoscopic suturing controlled arterial bleeding in five out of eight pigs with a single stitch and in another three pigs with an additional stitch. CONCLUSION: This animal model provides reproducible massive hemorrhage suitable for endoscopic studies. Control of gastric bleeding from large arteries by endoscopic suturing is possible.


Assuntos
Modelos Animais de Doenças , Hemostase Endoscópica/instrumentação , Úlcera Péptica Hemorrágica/cirurgia , Suínos , Animais , Artérias/cirurgia , Mucosa Gástrica/cirurgia , Gastrostomia , Ligadura/métodos , Reprodutibilidade dos Testes , Estômago/irrigação sanguínea
16.
Endoscopy ; 37(5): 411-4, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15844017

RESUMO

BACKGROUND AND STUDY AIMS: Surgical creation of a small gastric pouch with a restricted outlet is a well-established option for the treatment of morbid obesity. This report describes initial experience with endoscopic transoral stomach partition using a newly designed suturing apparatus. MATERIALS AND METHODS: A fresh porcine stomach was placed in the Erlangen model. A prototype suture device, incorporating a curved needle and an intracorporeal tightening mechanism, was used in this procedure. A long fishing line was first introduced into the stomach, with the two ends left outside. The suturing device, premounted outside a standard gastroscope, was inserted into the stomach and delivered several stitches attaching the fishing line to both the anterior and posterior walls along the line for the stomach to be partitioned. Five throws of half-hitches were tied onto the fishing line extracorporeally and separately pushed into place, creating a gastric pouch just below the esophagogastric junction. A flexible sheath of 8 cm long was then put on one side of the fishing line and pushed into the stomach. Additional extracorporeal knots were tied on the fishing line, forming a restrictive ring at the outlet of the pouch. The ring was then anchored to the stomach wall with similar endosutures. RESULTS: The proximal gastric pouch, with an estimated volume of approximately 100 ml, was successfully created with a restrictive band at its outlet. All of the stitches were securely sutured, with consistent penetration of the muscular layer of the stomach wall. CONCLUSIONS: In a bench model, it is technically possible to accomplish transoral gastroplasty endoscopically with an intraluminal suturing device. Further live animal studies will be needed in order to confirm the efficacy and safety of this procedure before clinical application.


Assuntos
Gastroplastia/instrumentação , Gastroscopia , Obesidade Mórbida/cirurgia , Técnicas de Sutura/instrumentação , Animais , Desenho de Equipamento , Gastroplastia/métodos , Técnicas In Vitro , Suínos
17.
Endoscopy ; 37(5): 415-7, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15844018

RESUMO

BACKGROUND AND STUDY AIMS: Endoscopic intracorporeal knots have potentially enormous applications in endoscopic surgery. We describe a method for testing the security of various types of endoscopically tied knots using a vessel perfusion manometer system. METHODS: A 4-cm segment of porcine splenic artery was placed on the mucosal surface of a pig stomach. The two ends of the vessel were brought out through the gastric wall and connected to a two-way manometer. One end was also joined to a pressure infusion bag. The stomach was mounted in an Erlangen training model. A long 3/0 nylon thread, previously introduced into the submucosal layer of the stomach and encircling the vessel, was brought out from the mouth. Three-throw square knots, Mayo knots, "surgeon's" knots and five-throw square knots were tied and pushed into place using a cap attached to a gastroscope. The pressure at the two ends of the artery was compared. If the pressure could be increased to over 200 mm Hg at one end without a change in the other, the knot was considered secure. RESULTS: Each type of knot was tested 12 times under endoscopic vision. The range for mean knotting time was 3.4 - 4.5 minutes. Five-throw knots took significantly longer to tie than three-throw knots (P < 0.005). There was one loose knot in each of the three-throw and Mayo groups, and three each in the "surgeon's" and five-throw groups (P > 0.05). CONCLUSIONS: This system is a reliable model for testing intracorporeal knots tied endoscopically. A three-half-hitches square knot with 3/0 nylon, tied using a flexible endoscope and knot-tightening cap, can withstand pressure up to 200 mm Hg.


Assuntos
Endoscopia , Artéria Esplênica/cirurgia , Estômago/cirurgia , Técnicas de Sutura , Animais , Humanos , Técnicas In Vitro , Manequins , Manometria , Perfusão , Reprodutibilidade dos Testes , Resistência ao Cisalhamento , Suínos , Resistência à Tração
18.
Prim Care ; 28(3): 591-606, vii, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11483446

RESUMO

Gallstones are common in the US and western countries. This article describes the pathogenesis of gallstone formation and the clinical manifestations and current approaches to diagnosis and treatment of the most common clinical conditions caused by gallstones: biliary colic, acute cholecystitis, choledocholithiasis, and acute gallstone pancreatitis. The role of widely used imaging techniques (transabdominal ultrasound, CT scan, MR imaging, and MRCP) and diagnostic and therapeutic endoscopy (endoscopic ultrasound, ERCP) is emphasized. This article is intended mainly for general practitioners, primary care physicians, and other specialists providing medical care to patients with gallstones and their complications.


Assuntos
Doenças Biliares/diagnóstico , Doenças Biliares/terapia , Colelitíase/diagnóstico , Colelitíase/terapia , Doença Aguda , Doenças Biliares/epidemiologia , Doenças Biliares/etiologia , Doenças Biliares/fisiopatologia , Colangiopancreatografia Retrógrada Endoscópica , Colelitíase/epidemiologia , Colelitíase/etiologia , Colelitíase/fisiopatologia , Doença Crônica , Medicina de Família e Comunidade/métodos , Humanos , Imageamento por Ressonância Magnética , Atenção Primária à Saúde/métodos , Encaminhamento e Consulta , Fatores de Risco , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...