1.
EJNMMI Res ; 7(1): 10, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28120177

RESUMO

BACKGROUND: The use of a normal database for [123I]FP-CIT SPECT imaging has been found to be helpful for cases which are difficult to interpret by visual assessment alone, and to improve reproducibility in scan interpretation. The aim of this study was to assess whether the use of different tomographic reconstructions affects the performance of a normal [123I]FP-CIT SPECT database and also whether systems benefit from a system characterisation before a database is used. Seventy-seven [123I]FP-CIT SPECT studies from two sites and with 3-year clinical follow-up were assessed quantitatively for scan normality using the ENC-DAT normal database obtained in well-documented healthy subjects. Patient and normal data were reconstructed with iterative reconstruction with correction for attenuation, scatter and septal penetration (ACSC), the same reconstruction without corrections (IRNC), and filtered back-projection (FBP) with data quantified using small volume-of-interest (VOI) (BRASS) and large VOI (Southampton) analysis methods. Test performance was assessed with and without system characterisation, using receiver operating characteristics (ROC) analysis for age-independent data and using sensitivity/specificity analysis with age-matched normal values. The clinical diagnosis at follow-up was used as the standard of truth. RESULTS: There were no significant differences in the age-independent quantitative assessment of scan normality across reconstructions, system characterisation and quantitative methods (ROC AUC 0.866-0.924). With BRASS quantification, there were no significant differences between the values of sensitivity (67.4-83.7%) or specificity (79.4-91.2%) across all reconstruction and calibration strategies. However, the Southampton method showed significant differences in sensitivity between ACSC (90.7%) vs IRNC (76.7%) and FBP (67.4%) reconstructions with calibration. Sensitivity using ACSC reconstruction with this method was also significantly better with calibration than without calibration (65.1%). Specificity using the Southampton method was unchanged across reconstruction and calibration choices (82.4-88.2%). CONCLUSIONS: The ability of a normal [123I]FP-CIT SPECT database to assess clinical scan normality is equivalent across all reconstruction, system characterisation, and quantification strategies using BRASS quantification. However, when using the Southampton quantification method, performance is sensitive to the reconstruction and calibration strategy used.

2.
Eur J Nucl Med Mol Imaging ; 41(10): 1938-46, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24806112

RESUMO

PURPOSE: Apart from binding to the dopamine transporter (DAT), [(123)I]FP-CIT shows moderate affinity for the serotonin transporter (SERT), allowing imaging of both monoamine transporters in a single imaging session in different brain areas. The aim of this study was to systematically evaluate extrastriatal binding (predominantly due to SERT) and its age and gender dependencies in a large cohort of healthy controls. METHODS: SPECT data from 103 healthy controls with well-defined criteria of normality acquired at 13 different imaging centres were analysed for extrastriatal binding using volumes of interest analysis for the thalamus and the pons. Data were examined for gender and age effects as well as for potential influence of striatal DAT radiotracer binding. RESULTS: Thalamic binding was significantly higher than pons binding. Partial correlations showed an influence of putaminal DAT binding on measured binding in the thalamus but not on the pons. Data showed high interindividual variation in extrastriatal binding. Significant gender effects with 31 % higher binding in women than in men were observed in the thalamus, but not in the pons. An age dependency with a decline per decade (±standard error) of 8.2 ± 1.3 % for the thalamus and 6.8 ± 2.9 % for the pons was shown. CONCLUSION: The potential to evaluate extrastriatal predominant SERT binding in addition to the striatal DAT in a single imaging session was shown using a large database of [(123)I]FP-CIT scans in healthy controls. For both the thalamus and the pons, an age-related decline in radiotracer binding was observed. Gender effects were demonstrated for binding in the thalamus only. As a potential clinical application, the data could be used as a reference to estimate SERT occupancy in addition to nigrostriatal integrity when using [(123)I]FP-CIT for DAT imaging in patients treated with selective serotonin reuptake inhibitors.


Assuntos
Neostriado/diagnóstico por imagem , Ponte/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética , Tálamo/diagnóstico por imagem , Tropanos/farmacocinética , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Especificidade de Órgãos , Ligação Proteica , Proteínas da Membrana Plasmática de Transporte de Serotonina/metabolismo , Fatores Sexuais , Tomografia Computadorizada de Emissão de Fóton Único
3.
EJNMMI Res ; 3(1): 39, 2013 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-23688063

RESUMO

BACKGROUND: Mesolimbic and nigrostriatal dopaminergic pathways play important roles in both the rewarding and conditioning effects of drugs. The dopamine transporter (DAT) is of central importance in regulating dopaminergic neurotransmission and in particular in activating the striatal D2-like receptors. Molecular imaging studies of the relationship between DAT availability/dopamine synthesis capacity and active cigarette smoking have shown conflicting results. Through the collaboration between 13 SPECT centres located in 10 different European countries, a database of FP-CIT-binding in healthy controls was established. We used the database to test the hypothesis that striatal DAT availability is changed in active smokers compared to non-smokers and ex-smokers. METHODS: A total of 129 healthy volunteers were included. Subjects were divided into three categories according to past and present tobacco smoking: (1) non-smokers (n = 64), (2) ex-smokers (n = 39) and (3) active smokers (n = 26). For imaging of the DAT availability, we used [123I]FP-CIT (DaTSCAN) and single photon emission computed tomography (SPECT). Data were collected in collaboration between 13 SPECT centres located in 10 different European countries. The striatal measure of DAT availability was analyzed in a multiple regression model with age, SPECT centre and smoking as predictor. RESULTS: There was no statistically significant difference in DAT availability between the groups of active smokers, ex-smokers and non-smokers (p = 0.34). Further, we could not demonstrate a significant association between striatal DAT and the number of cigarettes per day or total lifetime cigarette packages in smokers and ex-smokers. CONCLUSION: Our results do not support the hypothesis that large differences in striatal DAT availability are present in smokers compared to ex-smokers and healthy volunteers with no history of smoking.

4.
Eur J Nucl Med Mol Imaging ; 40(2): 213-27, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23160999

RESUMO

PURPOSE: Dopamine transporter (DAT) imaging with [(123)I]FP-CIT (DaTSCAN) is an established diagnostic tool in parkinsonism and dementia. Although qualitative assessment criteria are available, DAT quantification is important for research and for completion of a diagnostic evaluation. One critical aspect of quantification is the availability of normative data, considering possible age and gender effects on DAT availability. The aim of the European Normal Control Database of DaTSCAN (ENC-DAT) study was to generate a large database of [(123)I]FP-CIT SPECT scans in healthy controls. METHODS: SPECT data from 139 healthy controls (74 men, 65 women; age range 20-83 years, mean 53 years) acquired in 13 different centres were included. Images were reconstructed using the ordered-subset expectation-maximization algorithm without correction (NOACSC), with attenuation correction (AC), and with both attenuation and scatter correction using the triple-energy window method (ACSC). Region-of-interest analysis was performed using the BRASS software (caudate and putamen), and the Southampton method (striatum). The outcome measure was the specific binding ratio (SBR). RESULTS: A significant effect of age on SBR was found for all data. Gender had a significant effect on SBR in the caudate and putamen for the NOACSC and AC data, and only in the left caudate for the ACSC data (BRASS method). Significant effects of age and gender on striatal SBR were observed for all data analysed with the Southampton method. Overall, there was a significant age-related decline in SBR of between 4 % and 6.7 % per decade. CONCLUSION: This study provides a large database of [(123)I]FP-CIT SPECT scans in healthy controls across a wide age range and with balanced gender representation. Higher DAT availability was found in women than in men. An average age-related decline in DAT availability of 5.5 % per decade was found for both genders, in agreement with previous reports. The data collected in this study may serve as a reference database for nuclear medicine centres and for clinical trials using [(123)I]FP-CIT SPECT as the imaging marker.


Assuntos
Encéfalo/patologia , Valores de Referência , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tropanos/farmacologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Calibragem , Estudos de Casos e Controles , Bases de Dados Factuais , Demência/diagnóstico , Demência/diagnóstico por imagem , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Feminino , Humanos , Radioisótopos do Iodo/farmacologia , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Medicina Nuclear/métodos , Transtornos Parkinsonianos/diagnóstico , Transtornos Parkinsonianos/diagnóstico por imagem , Fatores Sexuais
5.
Eur J Nucl Med Mol Imaging ; 38(8): 1529-40, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21468761

RESUMO

PURPOSE: A joint initiative of the European Association of Nuclear Medicine (EANM) Neuroimaging Committee and EANM Research Ltd. aimed to generate a European database of [(123)I]FP-CIT single photon emission computed tomography (SPECT) scans of healthy controls. This study describes the characterization and harmonization of the imaging equipment of the institutions involved. METHODS: (123)I SPECT images of a striatal phantom filled with striatal to background ratios between 10:1 and 1:1 were acquired on all the gamma cameras with absolute ratios measured from aliquots. The images were reconstructed by a core lab using ordered subset expectation maximization (OSEM) without corrections (NC), with attenuation correction only (AC) and additional scatter and septal penetration correction (ACSC) using the triple energy window method. A quantitative parameter, the simulated specific binding ratio (sSBR), was measured using the "Southampton" methodology that accounts for the partial volume effect and compared against the actual values obtained from the aliquots. Camera-specific recovery coefficients were derived from linear regression and the error of the measurements was evaluated using the coefficient of variation (COV). RESULTS: The relationship between measured and actual sSBRs was linear across all systems. Variability was observed between different manufacturers and, to a lesser extent, between cameras of the same type. The NC and AC measurements were found to underestimate systematically the actual sSBRs, while the ACSC measurements resulted in recovery coefficients close to 100% for all cameras (AC range 69-89%, ACSC range 87-116%). The COV improved from 46% (NC) to 32% (AC) and to 14% (ACSC) (p < 0.001). CONCLUSION: A satisfactory linear response was observed across all cameras. Quantitative measurements depend upon the characteristics of the SPECT systems and their calibration is a necessary prerequisite for data pooling. Together with accounting for partial volume, the correction for scatter and septal penetration is essential for accurate quantification.


Assuntos
Bases de Dados Factuais , Câmaras gama/normas , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/normas , Tropanos , Calibragem , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Europa (Continente) , Humanos , Padrões de Referência
6.
Eur J Nucl Med Mol Imaging ; 37(2): 443-50, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19838702

RESUMO

These guidelines summarize the current views of the European Association of Nuclear Medicine Neuroimaging Committee (ENC). The aim of the guidelines is to assist nuclear medicine practitioners when making recommendations, performing, interpreting, and reporting the results of clinical dopamine transporter (DAT) single photon emission computed tomography (SPECT) studies using (123)I-labelled radiopharmaceuticals. The aim is to achieve a high-quality standard of DAT SPECT imaging, which will increase the diagnostic impact of this technique in neurological practice. The present document is an update of the 2002 guidelines [1] and has been guided by the views of various national societies: the Task Group Neuro-Nuclear-Medicine of the German Society of Nuclear Medicine [2], a consensus statement of the imaging centres included in the "Kompetenznetz-Parkinson" sponsored by the German Federal Ministry of Education, and the Task Group of Neuro-Nuclear-Medicine of the French Society of Nuclear Medicine [3]. The guidelines reflect the individual experience of experts in European countries. The guidelines are intended to present information specifically adapted to European practice. The information provided should be taken in the context of local conditions and regulations.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Dopamina/farmacocinética , Tomografia por Emissão de Pósitrons/normas , Guias de Prática Clínica como Assunto , Receptores de Dopamina D2/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único/normas , União Europeia , Feminino , Humanos , Masculino , Compostos Radiofarmacêuticos/farmacocinética , Transmissão Sináptica/fisiologia
7.
Eur J Nucl Med Mol Imaging ; 37(2): 434-42, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19838704

RESUMO

The guidelines summarize the current views of the European Association of Nuclear Medicine Neuroimaging Committee (ENC). The aims of the guidelines are to assist nuclear medicine practitioners in making recommendations, performing, interpreting and reporting the results of clinical dopamine D2 receptor SPECT or PET studies, and to achieve a high quality standard of dopamine D2 receptor imaging, which will increase the impact of this technique in neurological practice.The present document is an update of the first guidelines for SPECT using D2 receptor ligands labelled with (123)I [1] and was guided by the views of the Society of Nuclear Medicine Brain Imaging Council [2], and the individual experience of experts in European countries. The guidelines intend to present information specifically adapted to European practice. The information provided should be taken in the context of local conditions and regulations.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Dopamina/farmacocinética , Tomografia por Emissão de Pósitrons/normas , Guias de Prática Clínica como Assunto , Receptores de Dopamina D2/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único/normas , União Europeia , Feminino , Humanos , Masculino , Compostos Radiofarmacêuticos/farmacocinética , Transmissão Sináptica/fisiologia
8.
Eur J Nucl Med Mol Imaging ; 36(12): 2093-102, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19838703

RESUMO

These guidelines summarize the current views of the European Association of Nuclear Medicine Neuroimaging Committee (ENC). The purpose of the guidelines is to assist nuclear medicine practitioners when making recommendations, performing, interpreting, and reporting the results of brain perfusion single photon emission computed tomography (SPECT) studies using (99m)Tc-labelled radiopharmaceuticals. The aim is to achieve a high quality standard for brain perfusion SPECT imaging, which will increase the diagnostic impact of this technique in clinical practice. The present document replaces a former version of the guideline published in 2001 which was inspired by the Society of Nuclear Medicine Procedure Guideline for Brain Perfusion SPECT [1], the views of the Society of Nuclear Medicine Brain Imaging Council [2], and the individual experience of experts in European countries. The guidelines are intended to present information specifically adapted to European practice. The information provided should be taken in the context of local conditions and regulations.


Assuntos
Encéfalo/diagnóstico por imagem , Medicina Nuclear/métodos , Compostos de Organotecnécio , Imagem de Perfusão/métodos , Compostos Radiofarmacêuticos , Sociedades , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Criança , Contraindicações , Europa (Continente) , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Medicina Nuclear/instrumentação , Administração dos Cuidados ao Paciente , Imagem de Perfusão/efeitos adversos , Imagem de Perfusão/instrumentação , Gravidez , Compostos Radiofarmacêuticos/efeitos adversos , Relatório de Pesquisa , Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
9.
Eur J Nucl Med Mol Imaging ; 36(12): 2103-10, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19838705

RESUMO

These guidelines summarize the current views of the European Association of Nuclear Medicine Neuroimaging Committee (ENC). The purpose of the guidelines is to assist nuclear medicine practitioners in making recommendations, performing, interpreting, and reporting the results of fluorine-18 fluoro-2-deoxyglucose ([(18)F]FDG) PET imaging of the brain. The aim is to help achieve a high standard of FDG imaging, which will increase the diagnostic impact of this technique in neurological and psychiatric practice. The present document replaces a former version of the guidelines that were published in 2002 [1] and includes an update in the light of advances in PET technology, the introduction of hybrid PET/CT systems and the broadening clinical indications for FDG brain imaging. These guidelines are intended to present information specifically adapted for European practice. The information provided should be taken in the context of local conditions and regulations.


Assuntos
Encéfalo/diagnóstico por imagem , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons/métodos , Sociedades , Adulto , Criança , Contraindicações , Europa (Continente) , Feminino , Fluordesoxiglucose F18/efeitos adversos , Humanos , Interpretação de Imagem Assistida por Computador , Administração dos Cuidados ao Paciente , Tomografia por Emissão de Pósitrons/efeitos adversos , Gravidez , Relatório de Pesquisa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...