Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
ACS Omega ; 9(8): 8810-8817, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38434806

RESUMO

This study examines the fog-harvesting ability of graphene oxide surfaces patterned by hydrophobic domains. The samples were prepared from graphene deposited using low pressure chemical vapor deposition, which was later plasma oxidized to obtain hydrophilic graphene oxide (GO) surfaces. Hydrophobic domains on GO surfaces were formed by initiated CVD (iCVD) of a low-surface-energy poly(perfluorodecyl alkylate) (PPFDA) polymer. Hence, patterned surfaces with hydrophobic/hydrophilic contrast were produced with ease in an all-dry manner. The structures of the as-deposited graphene and PPFDA films were characterized using Raman and Fourier transform infrared spectrophotometer analyses, respectively. The fog harvesting performance of the samples was measured using the fog generated by a nebulizer, in which the average diameter of the fog droplets is comparable to meteorological fog. According to the fog harvesting experiment results, 100 cm2 of the as-patterned surface can collect fog up to 2.5 L in 10 h in a foggy environment. Hence, hydrophilic/hydrophobic patterned surfaces in this study can be considered as promising fog harvesting materials. Both CVD techniques used in the production of hydrophilic/hydrophobic patterned surfaces can be easily applied to the production of large-scale materials.

2.
J Adv Res ; 36: 39-49, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35127163

RESUMO

Introduction: Nanomaterials aggregation within polyamide (PA) layer of thin film nanocomposite (TFN) membrane is found to be a common issue and can negatively affect membrane filtration performance. Thus, post-treatment on the surface of TFN membrane is one of the strategies to address the problem. Objective: In this study, an eco-friendly surface modification technique based on plasma enhanced chemical vapour deposition (PECVD) was used to deposit hydrophilic acrylic acid (AA) onto the PA surface of TFN membrane with the aims of simultaneously minimizing the PA surface defects caused by nanomaterials incorporation and improving the membrane surface hydrophilicity for reverse osmosis (RO) application. Methods: The TFN membrane was first synthesized by incorporating 0.05 wt% of functionalized titania nanotubes (TNTs) into its PA layer. It was then subjected to 15-s plasma deposition of AA monomer to establish extremely thin hydrophilic layer atop PA nanocomposite layer. PECVD is a promising surface modification method as it offers rapid and solvent-free functionalization for the membranes. Results: The findings clearly showed that the sodium chloride rejection of the plasma-modified TFN membrane was improved with salt passage reduced from 2.43% to 1.50% without significantly altering pure water flux. The AA-modified TFN membrane also exhibited a remarkable antifouling property with higher flux recovery rate (>95%, 5-h filtration using 1000 mg/L sodium alginate solution) compared to the unmodified TFN membrane (85.8%), which is mainly attributed to its enhanced hydrophilicity and smoother surface. Furthermore, the AA-modified TFN membrane also showed higher performance stability throughout 12-h filtration period. Conclusion: The deposition of hydrophilic material on the TFN membrane surface via eco-friendly method is potential to develop a defect-free TFN membrane with enhanced fouling resistance for improved desalination process.


Assuntos
Incrustação Biológica , Nanocompostos , Incrustação Biológica/prevenção & controle , Filtração/métodos , Nanocompostos/química , Nylons/química , Osmose
3.
Langmuir ; 37(5): 1941-1947, 2021 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-33507758

RESUMO

This study demonstrates the coating of a transparent and robust organic thin film having an excellent hydrophilicity-based antifogging property by an initiated chemical vapor deposition (iCVD) method. iCVD was able to synthesize linear and cross-liked poly(acrylic acid) (PAA) from the vapors of acrylic acid (AA) and ethylene glycol dimethacrylate (EGDMA) using tert-butyl peroxide (TBPO) as an initiator. High deposition rates of up to 35 nm/min were observed at low deposition temperatures. It was possible to control the quantity of comonomers in the as-deposited films by adjusting the partial pressure of the EGDMA cross-linking agent. The effect of the EGDMA partial pressure on chemical structure was studied using Fourier transform infrared (FTIR) and X-ray photoelectron spectroscopy (XPS) techniques. FTIR and XPS spectra of the as-deposited films showed the complete retention of the monomer functionality during iCVD. Hydrophilicities and large-area uniformity of the coatings were revealed using water contact angle measurements. The as-deposited PAA film was the most hydrophilic with a water contact angle (WCA) of 7.0°, while cross-linking with EGDMA increased the WCA values by up to 51.7°. Results of various tests, which were based on exposing the coated surfaces to artificial fog and hot water vapor, showed the excellent antifogging property of the coatings. Films were never fogged upon extensive and long-term exposure (2 months) to humid air.

4.
Membranes (Basel) ; 10(12)2020 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-33297433

RESUMO

In this work, several ultrafiltration (UF) membranes with enhanced antifouling properties were fabricated using a rapid and green surface modification method that was based on the plasma-enhanced chemical vapor deposition (PECVD). Two types of hydrophilic monomers-acrylic acid (AA) and 2-hydroxyethyl methacrylate (HEMA) were, respectively, deposited on the surface of a commercial UF membrane and the effects of plasma deposition time (i.e., 15 s, 30 s, 60 s, and 90 s) on the surface properties of the membrane were investigated. The modified membranes were then subjected to filtration using 2000 mg/L pepsin and bovine serum albumin (BSA) solutions as feed. Microscopic and spectroscopic analyses confirmed the successful deposition of AA and HEMA on the membrane surface and the decrease in water contact angle with increasing plasma deposition time strongly indicated the increase in surface hydrophilicity due to the considerable enrichment of the hydrophilic segment of AA and HEMA on the membrane surface. However, a prolonged plasma deposition time (>15 s) should be avoided as it led to the formation of a thicker coating layer that significantly reduced the membrane pure water flux with no significant change in the solute rejection rate. Upon 15-s plasma deposition, the AA-modified membrane recorded the pepsin and BSA rejections of 83.9% and 97.5%, respectively, while the HEMA-modified membrane rejected at least 98.5% for both pepsin and BSA. Compared to the control membrane, the AA-modified and HEMA-modified membranes also showed a lower degree of flux decline and better flux recovery rate (>90%), suggesting that the membrane antifouling properties were improved and most of the fouling was reversible and could be removed via simple water cleaning process. We demonstrated in this work that the PECVD technique is a promising surface modification method that could be employed to rapidly improve membrane surface hydrophilicity (15 s) for the enhanced protein purification process without using any organic solvent during the plasma modification process.

5.
ACS Appl Mater Interfaces ; 12(46): 52136-52145, 2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-33151052

RESUMO

Chromium(VI) contamination of drinking water arises from industrial activity wherever there is a lack of environmental legislation enforcement regarding the removal of such pollutants. Although it is possible to remove such harmful metal ions from drinking water through large-scale facilities, there currently exists no safe and simple way to filter chromium(VI) oxoanions at the point of use (which is potentially safer and necessary in remote locations or humanitarian scenarios). High-surface-area cloth substrates have been functionalized with calixarene molecules for the selective capture of aqueous chromium(VI) oxoanions in the presence of structurally similar anions. This is accomplished by pulsed plasmachemical deposition of a linker layer and subsequent functionalization with dimethylaminomethyl-calixarene (5,11,17,23-tetrakis[(dimethylamino)methyl]-25,26,27,28-tetrahydroxycalix[4]arene). Chromium(VI) oxoanions are captured by simply passing polluted water through the functionalized cloth, while other ions not harmful/beneficial to human health remain in the water. These cloth filters are simple to use, highly selective, and easily recyclable-thus making them attractive for point-of-use application in geographic regions lacking appropriate wastewater treatment plants or flawed environmental monitoring systems. Chromium(VI) pollutants have been successfully removed from real-world contaminated industrial wastewater streams using the dimethylaminomethyl-calixarene functionalized cloths.


Assuntos
Calixarenos/química , Cromo/química , Poluentes Químicos da Água/química , Purificação da Água/métodos , Adsorção , Cromo/isolamento & purificação , Gases em Plasma/química , Polipropilenos/química , Águas Residuárias/química , Poluentes Químicos da Água/isolamento & purificação
6.
Polymers (Basel) ; 12(9)2020 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-32825561

RESUMO

The non-selective property of conventional polyurethane (PU) foam tends to lower its oil absorption efficiency. To address this issue, we modified the surface properties of PU foam using a rapid solvent-free surface functionalization approach based on the chemical vapor deposition (CVD) method to establish an extremely thin yet uniform coating layer to improve foam performance. The PU foam was respectively functionalized using different monomers, i.e., perfluorodecyl acrylate (PFDA), 2,2,3,4,4,4-hexafluorobutyl acrylate (HFBA), and hexamethyldisiloxane (HMDSO), and the effect of deposition times (1, 5 and 10 min) on the properties of foam was investigated. The results showed that all the modified foams demonstrated a much higher water contact angle (i.e., greater hydrophobicity) and greater absorption capacities compared to the control PU foam. This is due to the presence of specific functional groups, e.g., fluorine (F) and silane (Si) in the modified PU foams. Of all, the PU/PHFBAi foam exhibited the highest absorption capacities, recording 66.68, 58.15, 53.70, and 58.38 g/g for chloroform, acetone, cyclohexane, and edible oil, respectively. These values were 39.19-119.31% higher than that of control foam. The promising performance of the PU/PHFBAi foam is due to the improved surface hydrophobicity attributed to the original perfluoroalkyl moieties of the HFBA monomer. The PU/PHFBAi foam also demonstrated a much more stable absorption performance compared to the control foam when both samples were reused for up to 10 cycles. This clearly indicates the positive impact of the proposed functionalization method in improving PU properties for oil absorption processes.

7.
Carbohydr Polym ; 159: 48-57, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28038753

RESUMO

In this study, surface-modified grinded coconut waste (CW) particles were used as bio-fillers to prepare polymeric composite materials with enhanced properties. Epoxy resin modified with acrylated and epoxidized soybean oil (AESO) was used as the polymer matrix. Two different strategies, namely chemical treatment and plasma enhanced chemical vapor deposition (PECVD) were utilized to modify the surface of CW particles for using them as compatible bio-fillers in composite preparation. Chemical modification involved the treatment of CW particles in a highly alkali NaOH solution, while PECVD modification involved coating of a thin film of hydrophobic poly(hexafluorobutyl acrylate) (PHFBA) around individual CW particle surfaces. Untreated and surface-modified CW particles were used in 10-50wt% for preparation of epoxy composites. FTIR analysis was performed to study the effect of modification on the structures of particles and as-prepared composites. The composite morphologies were investigated by XRD and SE. TGA test was conducted to study the thermal behavior of the composites. Also, the effects of CW particle surface modification on the mechanical and water sorption properties of epoxy resin composites were investigated in detail. It was observed that PECVD-treated CW particles had much more positive effects on the thermal, mechanical, wettability and flammability properties of composites.


Assuntos
Lignina/química , Polímeros/síntese química , Cocos/química , Interações Hidrofóbicas e Hidrofílicas , Polímeros/química , Propriedades de Superfície , Molhabilidade
8.
Artigo em Inglês | MEDLINE | ID: mdl-24474131

RESUMO

Intravascular ultrasound (IVUS) and intracardiac echography (ICE) catheters with real-time volumetric ultrasound imaging capability can provide unique benefits to many interventional procedures used in the diagnosis and treatment of coronary and structural heart diseases. Integration of capacitive micromachined ultrasonic transducer (CMUT) arrays with front-end electronics in single-chip configuration allows for implementation of such catheter probes with reduced interconnect complexity, miniaturization, and high mechanical flexibility. We implemented a single-chip forward-looking (FL) ultrasound imaging system by fabricating a 1.4-mm-diameter dual-ring CMUT array using CMUT-on-CMOS technology on a front-end IC implemented in 0.35-µm CMOS process. The dual-ring array has 56 transmit elements and 48 receive elements on two separate concentric annular rings. The IC incorporates a 25-V pulser for each transmitter and a low-noise capacitive transimpedance amplifier (TIA) for each receiver, along with digital control and smart power management. The final shape of the silicon chip is a 1.5-mm-diameter donut with a 430-µm center hole for a guide wire. The overall front-end system requires only 13 external connections and provides 4 parallel RF outputs while consuming an average power of 20 mW. We measured RF A-scans from the integrated single- chip array which show full functionality at 20.1 MHz with 43% fractional bandwidth. We also tested and demonstrated the image quality of the system on a wire phantom and an ex vivo chicken heart sample. The measured axial and lateral point resolutions are 92 µm and 251 µm, respectively. We successfully acquired volumetric imaging data from the ex vivo chicken heart at 60 frames per second without any signal averaging. These demonstrative results indicate that single-chip CMUT-on-CMOS systems have the potential to produce realtime volumetric images with image quality and speed suitable for catheter-based clinical applications.


Assuntos
Amplificadores Eletrônicos , Ecocardiografia/instrumentação , Imageamento Tridimensional/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Transdutores , Ultrassonografia de Intervenção/instrumentação , Animais , Galinhas , Sistemas Computacionais , Capacitância Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
IEEE Trans Biomed Circuits Syst ; 6(5): 454-67, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23853232

RESUMO

We designed and fabricated a dynamic receive beamformer integrated circuit (IC) in 0.35-µm CMOS technology. This beamformer IC is suitable for integration with an annular array transducer for high-frequency (30-50 MHz) intravascular ultrasound (IVUS) imaging. The beamformer IC consists of receive preamplifiers, an analog dynamic delay-and-sum beamformer, and buffers for 8 receive channels. To form an analog dynamic delay line we designed an analog delay cell based on the current-mode first-order all-pass filter topology, as the basic building block. To increase the bandwidth of the delay cell, we explored an enhancement technique on the current mirrors. This technique improved the overall bandwidth of the delay line by a factor of 6. Each delay cell consumes 2.1-mW of power and is capable of generating a tunable time delay between 1.75 ns to 2.5 ns. We successfully integrated the fabricated beamformer IC with an 8-element annular array. Experimental test results demonstrated the desired buffering, preamplification and delaying capabilities of the beamformer.


Assuntos
Ultrassonografia/instrumentação , Engenharia Biomédica , Vasos Sanguíneos/diagnóstico por imagem , Catéteres , Desenho de Equipamento , Humanos , Aumento da Imagem , Semicondutores , Processamento de Sinais Assistido por Computador , Transdutores , Ultrassonografia/estatística & dados numéricos
10.
Artigo em Inglês | MEDLINE | ID: mdl-23443696

RESUMO

Forward-looking (FL) catheter-based imaging systems are highly desirable for guiding interventions in intra- vascular ultrasound (IVUS) applications. One of the main challenges of array-based FL-IVUS systems is the large channel count, which results in increased system complexity. Synthetic phased-array processing with a reduced firing count simplifies the front-end and, hence, can enable 3-D real-time imaging. Recently, we have investigated dual-ring arrays suitable for IVUS imaging, in which the two concentric circular arrays are used separately as transmit (Tx) and receive (Rx) arrays. In this study, we present different optimized array designs based on dual and single circular rings which are suitable for synthetic phased-array processing with a reduced number of firings. To obtain an optimal firing set that produces low side lobes in the wideband response, we use a simulated annealing algorithm. In the simulations, we use 1.2-mm-diameter array configurations with 64 Tx and 58 Rx elements, a center frequency of 20 MHz and fractional bandwidths of 50% and 80%. The results show that optimized dual-ring arrays provide 8 dB improvements in peak near side-lobe level with no widening in the main lobe width when compared with full and other sparse co-arrays.


Assuntos
Aumento da Imagem/instrumentação , Transdutores , Ultrassonografia de Intervenção/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento
11.
Artigo em Inglês | MEDLINE | ID: mdl-23443701

RESUMO

One of the most important promises of capacitive micromachined ultrasonic transducer (CMUT) technology is integration with electronics. This approach is required to minimize the parasitic capacitances in the receive mode, especially in catheter-based volumetric imaging arrays, for which the elements must be small. Furthermore, optimization of the available silicon area and minimized number of connections occurs when the CMUTs are fabricated directly above the associated electronics. Here, we describe successful fabrication and performance evaluation of CMUT arrays for intravascular imaging on custom-designed CMOS receiver electronics from a commercial IC foundry. The CMUT-on-CMOS process starts with surface isolation and mechanical planarization of the CMOS electronics to reduce topography. The rest of the CMUT fabrication is achieved by modifying a low-temperature micromachining process through the addition of a single mask and developing a dry etching step to produce sloped sidewalls for simple and reliable CMUT-to-CMOS interconnection. This CMUT-to-CMOS interconnect method reduced the parasitic capacitance by a factor of 200 when compared with a standard wire-bonding method. Characterization experiments indicate that the CMUT-on-CMOS elements are uniform in frequency response and are similar to CMUTs simultaneously fabricated on standard silicon wafers without electronics integration. Ex- periments on a 1.6-mm-diameter dual-ring CMUT array with a center frequency of 15 MHz show that both the CMUTs and the integrated CMOS electronics are fully functional. The SNR measurements indicate that the performance is adequate for imaging chronic total occlusions located 1 cm from the CMUT array.


Assuntos
Eletrônica/instrumentação , Aumento da Imagem/instrumentação , Sistemas Microeletromecânicos/instrumentação , Semicondutores , Transdutores , Ultrassonografia de Intervenção/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas
12.
Artigo em Inglês | MEDLINE | ID: mdl-19942502

RESUMO

State-of-the-art 3-D medical ultrasound imaging requires transmitting and receiving ultrasound using a 2-D array of ultrasound transducers with hundreds or thousands of elements. A tight combination of the transducer array with integrated circuitry eliminates bulky cables connecting the elements of the transducer array to a separate system of electronics. Furthermore, preamplifiers located close to the array can lead to improved receive sensitivity. A combined IC and transducer array can lead to a portable, high-performance, and inexpensive 3-D ultrasound imaging system. This paper presents an IC flip-chip bonded to a 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array for 3-D ultrasound imaging. The IC includes a transmit beamformer that generates 25-V unipolar pulses with programmable focusing delays to 224 of the 256 transducer elements. One-shot circuits allow adjustment of the pulse widths for different ultrasound transducer center frequencies. For receiving reflected ultrasound signals, the IC uses the 32-elements along the array diagonals. The IC provides each receiving element with a low-noise 25-MHz-bandwidth transimpedance amplifier. Using a field-programmable gate array (FPGA) clocked at 100 MHz to operate the IC, the IC generated properly timed transmit pulses with 5-ns accuracy. With the IC flip-chip bonded to a CMUT array, we show that the IC can produce steered and focused ultrasound beams. We present 2-D and 3-D images of a wire phantom and 2-D orthogonal cross-sectional images (Bscans) of a latex heart phantom.


Assuntos
Eletrônica Médica/instrumentação , Imageamento Tridimensional/instrumentação , Transdutores , Ultrassonografia/instrumentação , Ecocardiografia , Desenho de Equipamento , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Ultrassonografia/métodos
13.
IEEE Trans Med Imaging ; 28(7): 1051-61, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19131299

RESUMO

In real-time ultrasonic 3-D imaging, in addition to difficulties in fabricating and interconnecting 2-D transducer arrays with hundreds of elements, there are also challenges in acquiring and processing data from a large number of ultrasound channels. The coarray (spatial convolution of the transmit and receive arrays) can be used to find efficient array designs that capture all of the spatial frequency content (a transmit-receive element combination corresponds to a spatial frequency) with a reduced number of active channels and firing events. Eliminating the redundancies in the transmit-receive element combinations and firing events reduces the overall system complexity and improves the frame rate. Here we explore four reduced redundancy 2-D array configurations for miniature 3-D ultrasonic imaging systems. Our approach is based on 1) coarray design with reduced redundancy using different subsets of linear arrays constituting the 2-D transducer array, and 2) 3-D scanning using fan-beams (narrow in one dimension and broad in the other dimension) generated by the transmit linear arrays. We form the overall array response through coherent summation of the individual responses of each transmit-receive array pairs. We present theoretical and simulated point spread functions of the array configurations along with quantitative comparison in terms of the front-end complexity and image quality.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Ultrassonografia/métodos , Algoritmos , Simulação por Computador , Transdutores
14.
Artigo em Inglês | MEDLINE | ID: mdl-18334340

RESUMO

For three-dimensional (3D) ultrasound imaging, connecting elements of a two-dimensional (2D) transducer array to the imaging system's front-end electronics is a challenge because of the large number of array elements and the small element size. To compactly connect the transducer array with electronics, we flip-chip bond a 2D 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array to a custom-designed integrated circuit (IC). Through-wafer interconnects are used to connect the CMUT elements on the top side of the array with flip-chip bond pads on the back side. The IC provides a 25-V pulser and a transimpedance preamplifier to each element of the array. For each of three characterized devices, the element yield is excellent (99 to 100% of the elements are functional). Center frequencies range from 2.6 MHz to 5.1 MHz. For pulse echo operation, the average - 6-dB fractional bandwidth is as high as 125%. Transmit pressures normalized to the face of the transducer are as high as 339 kPa and input-referred receiver noise is typically 1.2 to 2.1 mPa/pHz. The flip-chip bonded devices were used to acquire 3D synthetic aperture images of a wire-target phantom. Combining the transducer array and IC, as shown in this paper, allows for better utilization of large arrays, improves receive sensitivity, and may lead to new imaging techniques that depend on transducer arrays that are closely coupled to IC electronics.


Assuntos
Eletrônica Médica/instrumentação , Aumento da Imagem/instrumentação , Imageamento Tridimensional/instrumentação , Processamento de Sinais Assistido por Computador , Transdutores , Ultrassonografia/instrumentação , Algoritmos , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas
15.
Artigo em Inglês | MEDLINE | ID: mdl-16529123

RESUMO

In this study, a 64-element, 1.15-mm diameter annular-ring capacitive micromachined ultrasonic transducer (CMUT) array was characterized and used for forward-looking intravascular ultrasound (IVUS) imaging tests. The array was manufactured using low-temperature processes suitable for CMOS electronics integration on a single chip. The measured radiation pattern of a 43 X 140-microm2 array element depicts a 40 degrees view angle for forward-looking imaging around a 15-MHz center frequency in agreement with theoretical models. Pulse-echo measurements show a -10-dB fractional bandwidth of 104% around 17 MHz for wire targets 2.5 mm away from the array in vegetable oil. For imaging and SNR measurements, RF A-scan data sets from various targets were collected using an interconnect scheme forming a 32-element array configuration. An experimental point spread function was obtained and compared with simulated and theoretical array responses, showing good agreement. Therefore, this study demonstrates that annular-ring CMUT arrays fabricated with CMOS-compatible processes are capable of forward-looking IVUS imaging, and the developed modeling tools can be used to design improved IVUS imaging arrays.


Assuntos
Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Transdutores , Ultrassonografia de Intervenção/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia de Intervenção/métodos
17.
Artigo em Inglês | MEDLINE | ID: mdl-15742561

RESUMO

The front-end hardware complexity of a coherent array imaging system scales with the number of active array elements that are simultaneously used for transmission or reception of signals. Different imaging methods use different numbers of active channels and data collection strategies. Conventional full phased array (FPA) imaging produces the best image quality using all elements for both transmission and reception, and it has high front-end hardware complexity. In contrast, classical synthetic aperture (CSA) imaging only transmits on and receives from a single element at a time, minimizing the hardware complexity but achieving poor image quality. We propose a new coherent array imaging method--phased subarray (PSA) imaging--that performs partial transmit and receive beam-forming using a subset of adjacent elements at each firing step. This method reduces the number of active channels to the number of subarray elements; these channels are multiplexed across the full array and a reduced number of beams are acquired from each subarray. The low-resolution subarray images are laterally upsampled, interpolated, weighted, and coherently summed to form the final high-resolution PSA image. The PSA imaging reduces the complexity of the front-end hardware while achieving image quality approaching that of FPA imaging.


Assuntos
Desenho Assistido por Computador , Ecocardiografia Doppler de Pulso/instrumentação , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Modelos Biológicos , Tomografia de Coerência Óptica/instrumentação , Transdutores , Simulação por Computador , Ecocardiografia Doppler de Pulso/métodos , Desenho de Equipamento , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos
18.
Artigo em Inglês | MEDLINE | ID: mdl-15742562

RESUMO

The basic principles and theory of phased subarray (PSA) imaging imaging provides the flexibility of reducing the number of front-end hardware channels between that of classical synthetic aperture (CSA) imaging--which uses only one element per firing event--and full-phased array (FPA) imaging-which uses all elements for each firing. The performance of PSA generally ranges between that obtained by CSA and FPA using the same array, and depends on the amount of hardware complexity reduction. For the work described in this paper, we performed FPA, CSA, and PSA imaging of a resolution phantom using both simulated and experimental data from a 3-MHz, 3.2-cm, 128-element capacitive micromachined ultrasound transducer (CMUT) array. The simulated system point responses in the spatial and frequency domains are presented as a means of studying the effects of signal bandwidth, reconstruction filter size, and subsampling rate on the PSA system performance. The PSA and FPA sector-scanned images were reconstructed using the wideband experimental data with 80% fractional bandwidth, with seven 32-element subarrays used for PSA imaging. The measurements on the experimental sector images indicate that, at the transmit focal zone, the PSA method provides a 10% improvement in the 6-dB lateral resolution, and the axial point resolution of PSA imaging is identical to that of FPA imaging. The signal-to-noise ratio (SNR) of PSA image was 58.3 dB, 4.9 dB below that of the FPA image, and the contrast-to-noise ratio (CNR) is reduced by 10%. The simulated and experimental test results presented in this paper validate theoretical expectations and illustrate the flexibility of PSA imaging as a way to exchange SNR and frame rate for simplified front-end hardware.


Assuntos
Desenho Assistido por Computador , Ecocardiografia Doppler de Pulso/instrumentação , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Modelos Biológicos , Tomografia de Coerência Óptica/instrumentação , Transdutores , Simulação por Computador , Ecocardiografia Doppler de Pulso/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia de Coerência Óptica/métodos
19.
Artigo em Inglês | MEDLINE | ID: mdl-16463489

RESUMO

Integration of front-end electronics with 2D capacitive micromachined ultrasonic transducer (CMUT) arrays has been a challenging issue due to the small element size and large channel count. We present design and verification of a front-end drive-readout integrated circuit for 3D ultrasonic imaging using 2D CMUT arrays. The circuit cell dedicated to a single CMUT array element consists of a high-voltage pulser and a low-noise readout amplifier. To analyze the circuit cell together with the CMUT element, we developed an electrical CMUT model with parameters derived through finite element analysis, and performed both the pre- and postlayout verification. An experimental chip consisting of 4 X 4 array of the designed circuit cells, each cell occupying a 200 X 200 microm2 area, was formed for the initial test studies and scheduled for fabrication in 0.8 microm, 50 V CMOS technology. The designed circuit is suitable for integration with CMUT arrays through flip-chip bonding and the CMUT-on-CMOS process.


Assuntos
Desenho Assistido por Computador , Aumento da Imagem/instrumentação , Imageamento Tridimensional/instrumentação , Modelos Lineares , Membranas Artificiais , Transdutores , Ultrassonografia/instrumentação , Simulação por Computador , Capacitância Elétrica , Eletrônica Médica , Desenho de Equipamento/métodos , Análise de Falha de Equipamento , Análise de Elementos Finitos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Microeletrodos , Miniaturização , Semicondutores , Integração de Sistemas , Ultrassonografia/métodos
20.
Artigo em Inglês | MEDLINE | ID: mdl-15301009

RESUMO

This paper reports the design and testing of forward-viewing annular arrays fabricated using capacitive micromachined ultrasonic transducer (CMUT) technology. Recent research studies have shown that CMUTs have broad frequency bandwidth and high-transduction efficiency. One- and two-dimensional CMUT arrays of various sizes already have been fabricated, and their viability for medical imaging applications has been demonstrated. We fabricated 64-element, forward-viewing annular arrays using the standard CMUT fabrication process and carried out experiments to measure the operating frequency, bandwidth, and transmit/receive efficiency of the array elements. The annular array elements, designed for imaging applications in the 20 MHz range, had a resonance frequency of 13.5 MHz in air. The immersion pulse-echo data collected from a plane reflector showed that the devices operate in the 5-26 MHz range with a fractional bandwidth of 135%. The output pressure at the surface of the transducer was measured to be 24 kPa/V. These values translate into a dynamic range of 131.5 dB for 1-V excitation in 1-Hz bandwidth with a commercial low noise receiving circuitry. The designed, forward-viewing annular CMUT array is suitable for mounting on the front surface of a cylindrical catheter probe and can provide Doppler information for measurement of blood flow and guiding information for navigation through blood vessels in intravascular ultrasound imaging.


Assuntos
Transdutores , Ultrassonografia/instrumentação , Capacitância Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...