Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Lett ; 29(7): 736-8, 2004 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-15072375

RESUMO

Comparison of two illumination modes for wide-field optical coherence tomography has revealed that spatially coherent illumination generates coherent cross talk, causing significant image degradation, and that spatially incoherent illumination, with an adequate interferometer design, provides an efficient mechanism for suppression of coherent cross talk. This is shown by comparison of a pulsed laser with a thermal light source for a U.S. Air Force resolution target covered with a scattering solution made from microbeads as well as for an ex vivo tooth.


Assuntos
Artefatos , Iluminação , Modelos Teóricos , Tomografia de Coerência Óptica , Desenho de Equipamento , Interferometria/instrumentação , Lasers , Microesferas , Espalhamento de Radiação , Tomografia de Coerência Óptica/instrumentação
2.
Opt Lett ; 28(24): 2476-8, 2003 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-14690119

RESUMO

A simple method for the calibration of optical path difference modulation in low-coherence interferometry is presented. Spectrally filtering a part of the detected interference signal results in a high-coherence signal that encodes the scan imperfections and permits their correction. The method is self-referenced in the sense that no secondary high-coherence light source is necessary. Using a spectrometer setup for spectral filtering allows for flexibility in both the choice of calibration wavelength and the maximum scan range. To demonstrate the method's usefulness, it is combined with a recently published digital spectral shaping technique to measure the thickness of a pellicle beam splitter with a white-light source.


Assuntos
Calibragem , Interferometria , Modelos Teóricos , Valores de Referência , Análise Espectral
3.
Opt Express ; 9(12): 610-5, 2001 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-19424297

RESUMO

Dispersive samples introduce a wavelength dependent phase distortion to the probe beam. This leads to a noticeable loss of depth resolution in high resolution OCT using broadband light sources. The standard technique to avoid this consequence is to balance the dispersion of the sample byarrangingadispersive materialinthereference arm. However, the impact of dispersion is depth dependent. A corresponding depth dependent dispersion balancing technique is diffcult to implement. Here we present a numerical dispersion compensation technique for Partial Coherence Interferometry (PCI) and Optical Coherence Tomography (OCT) based on numerical correlation of the depth scan signal with a depth variant kernel. It can be used a posteriori and provides depth dependent dispersion compensation. Examples of dispersion compensated depth scan signals obtained from microscope cover glasses are presented.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...