Artigo em Inglês | MEDLINE | ID: mdl-29550684

RESUMO

Vaccine production is a biological process in which variation in time and output is inevitable. Thus, the application of Process Analytical Technologies (PAT) will be important in this regard. Headspace solid - phase microextraction (HS-SPME) coupled with GC-MS can be used as a PAT for process monitoring. This method is suitable to chemical profiling of volatile organic compounds (VOCs) emitted from microorganisms. Tetanus is a lethal disease caused by Clostridium tetani (C. tetani) bacterium and vaccination is an ultimate way to prevent this disease. In this paper, SPME fiber was used for the investigation of VOCs emerging from C. tetani during cultivation. Different types of VOCs such as sulfur-containing compounds were identified and some of them were selected as biomarkers for bioreactor monitoring during vaccine production. In the second step, the portable dynamic air sampling (PDAS) device was used as an interface for sampling VOCs by SPME fibers. The sampling procedure was optimized by face-centered central composite design (FC-CCD). The optimized sampling time and inlet gas flow rates were 10 min and 2 m L s-1, respectively. PDAS was mounted in exhausted gas line of bioreactor and 42 samples of VOCs were prepared by SPME fibers in 7 days during incubation. Simultaneously, pH and optical density (OD) were evaluated to cultivation process which showed good correlations with the identified VOCs (>80%). This method could be used for VOCs sampling from off-gas of a bioreactor to monitoring of the cultivation process.


Assuntos
Reatores Biológicos/microbiologia , Clostridium tetani/metabolismo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/métodos , Clostridium tetani/química , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/metabolismo
2.
Anal Bioanal Chem ; 409(29): 6739-6744, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29030669

RESUMO

A novel and efficient headspace solid-phase microextraction (HS-SPME) method, followed by gas chromatography mass spectrometry (GC-MS), was developed to study volatile organic compounds (VOCs) emerging from microorganisms. Two homemade SPME fibers, a semi-polar poly (dimethylsiloxane) (PDMS) fiber, and a polar polyethylene glycol (PEG) fiber, along with two commercial fibers (PDMS and PDMS/DVB) were used to collect VOCs emerging from Clostridium tetani which was cultured in different media. The adsorbed VOCs were desorbed and identified, in vitro, using GC-MS. The adsorption efficiency was improved by optimizing the time duration of adsorption and desorption. About 50 components were identified by the proposed method. The main detected compounds appeared to be sulfur containing compounds such as butanethioic acid S-methyl ester, dimethyl trisulfide, and dimethyl tetrasulfide. These volatile sulfur containing compounds are derived from amino acids containing the sulfur element, which probably coexist in the mentioned bacterium or are added to the culture media. The developed HS-SPME-GC-MS method allowed the determination of the chemical fingerprint of Clostridium tetani volatile constituents, and thus provides a new, simple, and reliable tool for studying the growth of microorganisms. Graphical abstract Investigation of biogenic VOCs released from Clostridium tetani using SPME-GC-MS.


Assuntos
Clostridium tetani/química , Microextração em Fase Sólida/métodos , Compostos Orgânicos Voláteis/análise , Adsorção , Dimetilpolisiloxanos/química , Cromatografia Gasosa-Espectrometria de Massas , Polietilenoglicóis/química , Compostos Orgânicos Voláteis/química
3.
Appl Opt ; 56(11): E58-E63, 2017 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-28414342

RESUMO

In this work, a combined flow injection-photo thermal lens microscopy (FI-PTLM) system was used for highly sensitive determination of captopril as an angiotensin-converting enzyme inhibitor. Captopril has no absorption in the visible range, but due to its thiol group could interact with gold nanoparticles (GNPs). GNPs, because of their surface plasmon resonance (SPR), have absorption in the visible range, but their interaction with a low concentration of captopril shows no effective change in UV-Vis spectrophotometry because their aggregation is slight. On the contrary, at the same condition, the PTLM with a visible light source enables sensitive measurement of this compound. The thiol group of captopril binds to the surface of GNPs and decreases the SPR. At the optimum condition in the focal volume of 2.68 fL (f=10-15), the obtained range of linearity was 50-800 nM. The developed method was successfully applied for the determination of captopril in human serum and pharmaceutical samples.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/análise , Captopril/análise , Ouro , Nanopartículas Metálicas/análise , Microscopia Eletrônica de Transmissão , Inibidores da Enzima Conversora de Angiotensina/sangue , Inibidores da Enzima Conversora de Angiotensina/química , Captopril/sangue , Captopril/química , Desenho de Equipamento , Humanos , Lentes , Luz , Nanopartículas Metálicas/química , Espectrofotometria/instrumentação , Espectrofotometria/métodos , Ressonância de Plasmônio de Superfície , Comprimidos/química
4.
Talanta ; 135: 7-17, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25640119

RESUMO

In this work, a rapid HPLC-DAD method has been developed for the analysis of six antibiotics (amoxicillin, metronidazole, sulfamethoxazole, ofloxacine, sulfadiazine and sulfamerazine) in the sewage treatment plant influent and effluent samples. Decreasing the chromatographic run time to less than 4 min as well as lowering the cost per analysis, were achieved through direct injection of the samples into the HPLC system followed by chemometric analysis. The problem of the complete separation of the analytes from each other and/or from the matrix ingredients was resolved as a posteriori. The performance of MCR/ALS and U-PLS/RBL, as second-order algorithms, was studied and comparable results were obtained from implication of these modeling methods. It was demonstrated that the proposed methods could be used promisingly as green analytical strategies for detection and quantification of the targeted pollutants in wastewater samples while avoiding the more complicated high cost instrumentations.


Assuntos
Antibacterianos/análise , Águas Residuárias/análise , Poluentes Químicos da Água/análise , Amoxicilina/análise , Cromatografia Líquida de Alta Pressão/métodos , Química Verde , Metronidazol/análise , Ofloxacino/análise , Sulfadiazina/análise , Sulfamerazina/análise , Sulfametoxazol/análise
5.
J Fluoresc ; 24(3): 855-8, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24522346

RESUMO

A very sensitive and selective spectrofluorimetric method has been developed for nickel (ΙΙ) determination in environmental samples. The method is based on measuring the decrease in fluorescence intensity of murexide after nickel (ΙΙ) binding. The intensity of the fluorescence emission peak was measured at ex/em 345/431 nm in several solutions with pH interval 3.0-7.0. The fluorescence intensity decrease was found to be linear in the concentration range of 0.007 mg.L(-1) to 0.1 mg.L(-1) and 0.1 mg.L(-1) to 20 mg.L(-1) of nickel (ΙΙ) by using 10(-4) M murexide at pH 3. The detection limit was found 0.004 mg.L(-1). Relatively large excesses of over 20 cations and anions do not interfere. The method was successfully applied to the analysis of nickel (ΙΙ) in sea, rain and ground water. This method is very precise and accurate (R.S.D. = 0.42% for the determination of 0.05 mg.L-(1) nickel in 10 replicates).


Assuntos
Água Subterrânea/análise , Murexida/química , Níquel/análise , Níquel/química , Chuva/química , Água do Mar/análise , Espectrometria de Fluorescência/métodos , Fluorescência , Concentração de Íons de Hidrogênio , Limite de Detecção , Murexida/metabolismo , Níquel/metabolismo
6.
Pharm Dev Technol ; 12(6): 573-80, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18161630

RESUMO

A novel analytical procedure has been developed for quantitative determination of levodopa and carbidopa in aqueous binary solutions acidified by HCl and without any other sample pretreatment. The method is based partially on least squares treatment of data obtained by attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectrometry in 1211-1315 cm(-1) and 1488-1550 cm(-1) spectral regions. The simple, rapid, and accurate proposed method was applied to determine levodopa and carbidopa in Levodopa-C tablets. The statistical parameters, such as R2, RSD, SEE, SECV, LOD, and recovery were evaluated. Number of factors, scans, and resolution were optimized. In this method R2 and RSD for levodopa and carbidopa were (0.9965, 1.209) and (0.9537, 0.813), respectively.


Assuntos
Antiparkinsonianos/análise , Carbidopa/análise , Levodopa/análise , Cromatografia Líquida de Alta Pressão , Interpretação Estatística de Dados , Combinação de Medicamentos , Espectroscopia de Infravermelho com Transformada de Fourier , Comprimidos