Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Environ Sci Pollut Res Int ; 31(9): 13925-13940, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38265594

RESUMO

This research determines the influence of green supply chain management practices (GSCM) on environmental performance. It also investigates the moderating role of supply chain environmental cooperation on GSCM practices and environmental performance relationships. A total of 370 employees of several Bangladeshi manufacturing companies were conveniently chosen as respondents. To verify the data validity and reliability and to test the hypotheses, we used SmartPLS. Finally, we employed an artificial neural network (ANN) to examine the relationship. Green design and green manufacturing have significant positive impacts on environmental performance, while green procurement and green distribution do not. Moreover, environmental cooperation moderates the relationships of green design and green distribution with environmental performance. The moderating effect of supply chain environmental cooperation in the relationship between GSCM practices and environmental performance in the manufacturing industry adds knowledge to the existing literature by incorporating a hybrid model combining PLS-SEM and ANN. Our study adds to the current body of knowledge by delving into the literature on GSCM from the perspective of Bangladesh's industrial sector. This study fills a knowledge gap by shedding light on the interactions of GSCM and environmental performance. Indeed, this study represents a step forward from classic linear regression-based models to an ANN-based nonlinear model. It also demonstrates new contributions to the literature on green supply chain management and environmental performance.


Assuntos
Comércio , Conservação dos Recursos Naturais , Humanos , Reprodutibilidade dos Testes , Indústrias , Indústria Manufatureira
2.
PLoS One ; 18(5): e0285482, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37163528

RESUMO

A crop simulation model is adopted to calculate the potential yield in a certain location. The data sets generated in each scenario (2021-2022) were used to evaluate the InfoCrop model. A field experiment using a randomized complete block design was conducted at the Agronomy Department's research field, Hajee Mohammad Danesh Science and Technology University. The following two factors: 1) factor A: sowing dates (Planting date 1: PD1 = 5th November and Planting date 2: PD2 = 15th November 2021) and 2) factor B: Trichoderma biofertilizers (T1 = control, T2 = 50% chemical fertilizer + 2,000 kg ha-1 Trichoderma biofertlizer, T3 = fully chemical fertilizer; and T4 = fully 3,000 kg ha-1 Trichoderma biofertilizer). Three BARI (Bangladesh Agricultural Research Institute) released varieties (V1 = BARI Sarisa-14, V2 = BARI Sarisa-16, and V3 = BARI Sarisa-17) used for the completion of the experiment. The Trichoderma biofertilizer and planting dates had a significant influence on yield and yield attributes of mustard. Results showed that plant height, leaf width, leaves per plant, pods per plant, harvest index, maturity date, and yield were significantly affected by Trichoderma biofertilizer treatments, two different conditions, and varieties. The regression analysis indicated a significant linear relationship between two different growing conditions especially for harvest index PD2>PD1 (0.88>0.83), grain yield (0.94>0.90), flowering date (0.95>0.91) and maturity date (0.95>0.90). It was found that the model significantly overestimated all the parameters with an acceptable error range (<15%) while growth and yield characteristics including flowering and maturity dates and yield were simulated and results were compared to observed data. BARI Sarisa 16 had the highest simulated yield of 2.5 t ha-1 and showed a high yielding variety among the used varieties in the experiment. As a result, it can be concluded that if the InfoCrop growth model is carefully calibrated, it will be an excellent tool for evaluating and identifying the best yielding variety.


Assuntos
Trichoderma , Humanos , Mostardeira , Fertilizantes/análise , Agricultura/métodos , Grão Comestível
3.
Front Cardiovasc Med ; 8: 744779, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34765656

RESUMO

Background: The majority of data regarding tissue substrate for post myocardial infarction (MI) VT has been collected during hemodynamically tolerated VT, which may be distinct from the substrate responsible for VT with hemodynamic compromise (VT-HC). This study aimed to characterize tissue at diastolic locations of VT-HC in a porcine model. Methods: Late Gadolinium Enhancement (LGE) cardiovascular magnetic resonance (CMR) imaging was performed in eight pigs with healed antero-septal infarcts. Seven pigs underwent electrophysiology study with venous arterial-extra corporeal membrane oxygenation (VA-ECMO) support. Tissue thickness, scar and heterogeneous tissue (HT) transmurality were calculated at the location of the diastolic electrograms of mapped VT-HC. Results: Diastolic locations had median scar transmurality of 33.1% and a median HT transmurality 7.6%. Diastolic activation was found within areas of non-transmural scar in 80.1% of cases. Tissue activated during the diastolic component of VT circuits was thinner than healthy tissue (median thickness: 5.5 mm vs. 8.2 mm healthy tissue, p < 0.0001) and closer to HT (median distance diastolic tissue: 2.8 mm vs. 11.4 mm healthy tissue, p < 0.0001). Non-scarred regions with diastolic activation were closer to steep gradients in thickness than non-scarred locations with normal EGMs (diastolic locations distance = 1.19 mm vs. 9.67 mm for non-diastolic locations, p < 0.0001). Sites activated late in diastole were closest to steep gradients in tissue thickness. Conclusions: Non-transmural scar, mildly decreased tissue thickness, and steep gradients in tissue thickness represent the structural characteristics of the diastolic component of reentrant circuits in VT-HC in this porcine model and could form the basis for imaging criteria to define ablation targets in future trials.

4.
Sci Rep ; 11(1): 5718, 2021 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-33707527

RESUMO

Recent dose reduction techniques have made retrospective computed tomography (CT) scans more applicable and extracting myocardial function from cardiac computed tomography (CCT) images feasible. However, hyperparameters of generic image intensity-based registration techniques, which are used for tracking motion, have not been systematically optimised for this modality. There is limited work on their validation for measuring regional strains from retrospective gated CCT images and open-source software for motion analysis is not widely available. We calculated strain using our open-source platform by applying an image registration warping field to a triangulated mesh of the left ventricular endocardium. We optimised hyperparameters of two registration methods to track the wall motion. Both methods required a single semi-automated segmentation of the left ventricle cavity at end-diastolic phase. The motion was characterised by the circumferential and longitudinal strains, as well as local area change throughout the cardiac cycle from a dataset of 24 patients. The derived motion was validated against manually annotated anatomical landmarks and the calculation of strains were verified using idealised problems. Optimising hyperparameters of registration methods allowed tracking of anatomical measurements with a mean error of 6.63% across frames, landmarks, and patients, comparable to an intra-observer error of 7.98%. Both registration methods differentiated between normal and dyssynchronous contraction patterns based on circumferential strain ([Formula: see text], [Formula: see text]). To test whether a typical 10 temporal frames sampling of retrospective gated CCT datasets affects measuring cardiac mechanics, we compared motion tracking results from 10 and 20 frames datasets and found a maximum error of [Formula: see text]. Our findings show that intensity-based registration techniques with optimal hyperparameters are able to accurately measure regional strains from CCT in a very short amount of time. Furthermore, sufficient sensitivity can be achieved to identify heart failure patients and left ventricle mechanics can be quantified with 10 reconstructed temporal frames. Our open-source platform will support increased use of CCT for quantifying cardiac mechanics.

5.
Int J Cardiol Heart Vasc ; 32: 100694, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33392384

RESUMO

AIMS: Left atrial (LA) remodelling is a common feature of many cardiovascular pathologies and is a sensitive marker of adverse cardiovascular outcomes. The aim of this study was to establish normal ranges for LA parameters derived from coronary computed tomographic angiography (CCTA) imaging using a standardised image processing pipeline to establish normal ranges in a previously described cohort. METHODS: CCTA imaging from 193 subjects recruited to the Budapest GLOBAL twin study was analysed. Indexed LA cavity volume (LACVi), LA surface area (LASAi), wall thickness and LA tissue volume (LATVi) were calculated. Wall thickness maps were combined into an atlas. Indexed LA parameters were compared with clinical variables to identify early markers of pathological remodelling. RESULTS: LACVi is similar between sexes (31 ml/m2 v 30 ml/m2) and increased in hypertension (33 ml/m2 v 29 ml/m2, p = 0.009). LASAi is greater in females than males (47.8 ml/m2 v 45.8 ml/m2 male, p = 0.031). Median LAWT was 1.45 mm. LAWT was lowest at the inferior portion of the posterior LA wall (1.14 mm) and greatest in the septum (median = 2.0 mm) (p < 0.001). Conditions known to predispose to the development of AF were not associated with differences in tissue thickness. CONCLUSIONS: The reported LACVi, LASAi, LATVi and tissue thickness derived from CCTA may serve as reference values for this age group and clinical characteristics for future studies. Increased LASAi in females in the absence of differences in LACVi or LATVi may indicate differential LA shape changes between the sexes. AF predisposing conditions, other than sex, were not associated with detectable changes in LAWT.Clinical trial registration:http://www.ClinicalTrials.gov/NCT01738828.

6.
Pract Radiat Oncol ; 11(1): 84-88, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32416269

RESUMO

PURPOSE: A recent clinical trial has demonstrated that noninvasive radioablation (NIRA) has the potential to reduce recurrent ventricular tachycardia (VT) that is refractory to drugs and standard catheter ablation. Electroanatomic mapping (EAM) that would be useful for planning is obtained during catheter ablation, but incompatibility between EAM and DICOM formats required for radiation planning has impeded the use of existing catheter-based mapping to guide NIRA and is an important hurdle for its wider adoption. In this paper we define a process to facilitate the fusion of catheter-based EAM with DICOM imaging for radiation planning. METHOD AND MATERIALS: The raw data export of the CARTO3 EAM system (version 6.0.45.171, ".mesh" file) was processed with a MATLAB script to generate 3-dimensional (3D) visual took kit files containing X, Y, Z coordinates obtained during mapping and corresponding impedance, voltage, and other point-based information. The image could then be visualized with standard image processing software (3D Slicer) and the target outlined on the image surface. This structure was in turn converted to a DICOM image and fused with patient thoracic imaging using anatomic landmarks. Robustness of the workflow was assessed through implementation with a second magnetic resonance imaging based VT ablation planning system, ADAS-VT. RESULTS: This process facilitated the fusion of EAM and DICOM imaging to inform selection of NIRA targets. The workflow was found to be robust and compatible with a second VT ablation planning system. CONCLUSIONS: The conversion of catheter-based EAM to a DICOM compatible format permits the fusion of images for radiation planning and provides an avenue for the wider application of NIRA. Further improvements in the compatibility of these imaging formats would be expected to improve quality and reproducibility of image fusion.


Assuntos
Imageamento Tridimensional , Taquicardia Ventricular , Catéteres , Humanos , Reprodutibilidade dos Testes , Taquicardia Ventricular/diagnóstico por imagem , Fluxo de Trabalho
7.
Med Image Anal ; 67: 101832, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33166776

RESUMO

Segmentation of medical images, particularly late gadolinium-enhanced magnetic resonance imaging (LGE-MRI) used for visualizing diseased atrial structures, is a crucial first step for ablation treatment of atrial fibrillation. However, direct segmentation of LGE-MRIs is challenging due to the varying intensities caused by contrast agents. Since most clinical studies have relied on manual, labor-intensive approaches, automatic methods are of high interest, particularly optimized machine learning approaches. To address this, we organized the 2018 Left Atrium Segmentation Challenge using 154 3D LGE-MRIs, currently the world's largest atrial LGE-MRI dataset, and associated labels of the left atrium segmented by three medical experts, ultimately attracting the participation of 27 international teams. In this paper, extensive analysis of the submitted algorithms using technical and biological metrics was performed by undergoing subgroup analysis and conducting hyper-parameter analysis, offering an overall picture of the major design choices of convolutional neural networks (CNNs) and practical considerations for achieving state-of-the-art left atrium segmentation. Results show that the top method achieved a Dice score of 93.2% and a mean surface to surface distance of 0.7 mm, significantly outperforming prior state-of-the-art. Particularly, our analysis demonstrated that double sequentially used CNNs, in which a first CNN is used for automatic region-of-interest localization and a subsequent CNN is used for refined regional segmentation, achieved superior results than traditional methods and machine learning approaches containing single CNNs. This large-scale benchmarking study makes a significant step towards much-improved segmentation methods for atrial LGE-MRIs, and will serve as an important benchmark for evaluating and comparing the future works in the field. Furthermore, the findings from this study can potentially be extended to other imaging datasets and modalities, having an impact on the wider medical imaging community.


Assuntos
Benchmarking , Gadolínio , Algoritmos , Átrios do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética
8.
Circ Cardiovasc Imaging ; 13(12): e011512, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33317334

RESUMO

BACKGROUND: Pathological atrial fibrosis is a major contributor to sustained atrial fibrillation. Currently, late gadolinium enhancement (LGE) scans provide the only noninvasive estimate of atrial fibrosis. However, widespread adoption of atrial LGE has been hindered partly by nonstandardized image processing techniques, which can be operator and algorithm dependent. Minimal validation and limited access to transparent software platforms have also exacerbated the problem. This study aims to estimate atrial fibrosis from cardiac magnetic resonance scans using a reproducible operator-independent fully automatic open-source end-to-end pipeline. METHODS: A multilabel convolutional neural network was designed to accurately delineate atrial structures including the blood pool, pulmonary veins, and mitral valve. The output from the network removed the operator dependent steps in a reproducible pipeline and allowed for automated estimation of atrial fibrosis from LGE-cardiac magnetic resonance scans. The pipeline results were compared against manual fibrosis burdens, calculated using published thresholds: image intensity ratio 0.97, image intensity ratio 1.61, and mean blood pool signal +3.3 SD. RESULTS: We validated our methods on a large 3-dimensional LGE-cardiac magnetic resonance data set from 207 labeled scans. Automatic atrial segmentation achieved a 91% Dice score, compared with the mutual agreement of 85% in Dice seen in the interobserver analysis of operators. Intraclass correlation coefficients of the automatic pipeline with manually generated results were excellent and better than or equal to interobserver correlations for all 3 thresholds: 0.94 versus 0.88, 0.99 versus 0.99, 0.99 versus 0.96 for image intensity ratio 0.97, image intensity ratio 1.61, and +3.3 SD thresholds, respectively. Automatic analysis required 3 minutes per case on a standard workstation. The network and the analysis software are publicly available. CONCLUSIONS: Our pipeline provides a fully automatic estimation of fibrosis burden from LGE-cardiac magnetic resonance scans that is comparable to manual analysis. This removes one key source of variability in the measurement of atrial fibrosis.


Assuntos
Átrios do Coração/diagnóstico por imagem , Cardiopatias/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Redes Neurais de Computação , Automação , Meios de Contraste , Fibrose , Átrios do Coração/patologia , Cardiopatias/patologia , Humanos , Variações Dependentes do Observador , Compostos Organometálicos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
9.
J Cardiovasc Magn Reson ; 22(1): 13, 2020 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-32036784

RESUMO

BACKGROUND: Using cardiovascular magnetic resonance imaging (CMR), it is possible to detect diffuse fibrosis of the left ventricle (LV) in patients with atrial fibrillation (AF), which may be independently associated with recurrence of AF after ablation. By conducting CMR, clinical, electrophysiology and biomarker assessment we planned to investigate LV myocardial fibrosis in patients undergoing AF ablation. METHODS: LV fibrosis was assessed by T1 mapping in 31 patients undergoing percutaneous ablation for AF. Galectin-3, coronary sinus type I collagen C terminal telopeptide (ICTP), and type III procollagen N terminal peptide were measured with ELISA. Comparison was made between groups above and below the median for LV extracellular volume fraction (ECV), followed by regression analysis. RESULTS: On linear regression analysis LV ECV had significant associations with invasive left atrial pressure (Beta 0.49, P = 0.008) and coronary sinus ICTP (Beta 0.75, P < 0.001), which remained significant on multivariable regression. CONCLUSION: LV fibrosis in patients with AF is associated with left atrial pressure and invasively measured levels of ICTP turnover biomarker.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda , Remodelação Ventricular , Adulto , Idoso , Fibrilação Atrial/sangue , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Pressão Atrial , Biomarcadores/sangue , Proteínas Sanguíneas , Ablação por Cateter , Colágeno Tipo I/sangue , Técnicas Eletrofisiológicas Cardíacas , Feminino , Fibrose , Galectina 3/sangue , Galectinas , Ventrículos do Coração/metabolismo , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/sangue , Peptídeos/sangue , Valor Preditivo dos Testes , Pró-Colágeno/sangue
10.
SoftwareX ; 12: 100570, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-34124331

RESUMO

Personalised medicine is based on the principle that each body is unique and will respond to therapies differently. In cardiology, characterising patient specific cardiovascular properties would help in personalising care. One promising approach for characterising these properties relies on performing computational analysis of multimodal imaging data. An interactive cardiac imaging environment, which can seamlessly render, manipulate, derive calculations, and otherwise prototype research activities, is therefore sought-after. We developed the Cardiac Electro-Mechanics Research Group Application (CemrgApp) as a platform with custom image processing and computer vision toolkits for applying statistical, machine learning and simulation approaches to study physiology, pathology, diagnosis and treatment of the cardiovascular system. CemrgApp provides an integrated environment, where cardiac data visualisation and workflow prototyping are presented through a common graphical user interface.

11.
Europace ; 21(12): 1817-1823, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31793653

RESUMO

AIMS: A point-by-point workflow for pulmonary vein isolation (PVI) targeting pre-defined Ablation Index values (a composite of contact force, time, and power) and minimizing interlesion distance may optimize the creation of contiguous ablation lesions whilst minimizing scar formation. We aimed to compare ablation scar formation in patients undergoing PVI using this workflow to patients undergoing a continuous catheter drag workflow. METHODS AND RESULTS: Post-ablation cardiovascular magnetic resonance imaging was performed in patients undergoing 1st-time PVI using a parameter-guided point-by-point workflow (n = 26). Total left atrial scar burden and the width and continuity of the pulmonary vein encirclement were determined on analysis of atrial late gadolinium enhancement sequences. Comparison was made with a cohort of patients (n = 20) undergoing PVI using continuous drag lesions. Mean post-ablation scar burden and scar width were significantly lower in the point-by-point group than in the control group (6.6 ± 6.8% vs. 9.6 ± 5.0%, P = 0.03 and 7.9 ± 3.6 mm vs. 10.7 ± 2.3 mm, P = 0.003). More complete bilateral pulmonary vein encirclements were seen in the point-by-point group (P = 0.038). All patients achieved acute PVI. CONCLUSION: Pulmonary vein isolation using a point-by-point workflow is feasible and results in a lower scar burden and scar width with more complete pulmonary vein encirclements than a conventional drag lesion approach.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Cicatriz/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Fluxo de Trabalho
12.
J Cardiovasc Electrophysiol ; 30(10): 1894-1903, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31397511

RESUMO

INTRODUCTION: Multiple cardiac magnetic resonance (CMR)-derived indices of atrial fibrillation (AF) substrate have been shown in isolation to predict long-term outcome following catheter ablation. Left atrial (LA) fibrosis, LA volume, LA ejection fraction (EF), left ventricular ejection fraction (LVEF), LA shape (sphericity) and pulmonary vein anatomy have all been shown to correlate with late AF recurrence. This study aimed to validate and assess the relative contribution of multiple indices in a long-term single-center study. METHODS AND RESULTS: Eighty-nine patients (53% paroxysmal AF, 73% male) underwent comprehensive CMR study before first-time AF ablation (median follow-up 726 days [IQR: 418-1010 days]). The 3D late gadolinium-enhanced acquisition (1.5T, 1.3 × 1.3 × 2 mm) was quantified for fibrosis; LA volume and sphericity were assessed on manual segmentation at atrial diastole; LAEF and LVEF were quantified on multislice cine imaging. AF recurred in 43 patients (48%) overall (31 at 1 year). In the recurrence group, LA fibrosis was higher (42% vs 29%; hazard ratio [HR]: 1.032; P = .002), left atrial ejection fraction (LAEF) lower (25% vs 34%; HR: 0.063; P = .016) and LVEF lower (57% vs 63%; HR: 0.011; P = .008). LA volume (135 vs 124 mL) and sphericity (0.819 vs 0.822) were similar. Multivariate Cox regression analysis was adjusted for age and sex (Model 1), additionally AF type (Model 2) and combined (Model 3). In Models 1 and 2, LA fibrosis, LAEF, and LVEF were independently associated with outcome, but only LA fibrosis was independent in Model 3 (HR: 1.021; P = .022). CONCLUSIONS: LAEF, LVEF, and LA fibrosis differed significantly in the AF recurrence cohort. However, on combined multivariate analysis only LA fibrosis remained independently associated with outcome.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Imagem Cinética por Ressonância Magnética , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Remodelamento Atrial , Ablação por Cateter/efeitos adversos , Feminino , Fibrose , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Recidiva , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
14.
J Cardiovasc Electrophysiol ; 30(1): 67-77, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30255652

RESUMO

INTRODUCTION: The VisiTag module (CARTO3) provides an objective assessment of radiofrequency (RF) ablation parameters. This study aimed to determine the predictive value and optimal VisiTag threshold settings for prediction of gaps in mature atrial scar, as assessed non-invasively using cardiac magnetic resonance (CMR) imaging. METHODS: Twenty-four subjects (11 paroxysmal atrial fibrillation) underwent first-time RF ablation with operators blinded to VisiTag data. Three-dimensional late gadolinium enhancement (LGE) CMR scans were performed at 3 months (1.3 × 1.3 × 4 mm3 ). A survey of UK operators defined the standard VisiTag settings ("Force," 8 g; "Time," 10 seconds; "Percentage Time," 50%; "Range," 3 mm; "Impedance" and "Temperature" "off"). Each ablation procedure was exported 27 times, varying single VisiTag parameters from default values. The presence of gaps in VisiTag markers (18 sectors) was assessed for each export and compared with gaps in CMR enhancement. RESULTS: At default settings, VisiTag gaps were specific (97.5%) but less sensitive (50.4%) for CMR gaps. Sensitivity improved at higher thresholds (89.2% at 20 g, 85.6% at 30 seconds, 88.5% impedance 10 Ω, 92.8% temperature 42°C), but with a lower positive predictive value (PPV) (42.3%, 42.7%, 41.1%, and 37.7%, respectively, vs 90.9% at baseline). "Force" thresholds demonstrated stable PPV from 2 to 8 g (P = 0.24), but a rapid fall at forces more than 10 g. The binomial logistic regression model explained 41.7% of gaps; χ 2 (4), 148; P < 0.0001, correctly classifying 82% of cases (specificity 94.9%, sensitivity 56.8%). CONCLUSION: Gaps in VisiTags predict gaps in CMR LGE enhancement with high specificity at default settings. Sensitivity may be improved using more stringent thresholds but at the potential cost of unnecessary ablation, particularly when a force more than 10 g is stipulated.


Assuntos
Fibrilação Atrial/cirurgia , Remodelamento Atrial , Ablação por Cateter/efeitos adversos , Cicatriz/diagnóstico por imagem , Átrios do Coração/cirurgia , Imageamento por Ressonância Magnética , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Cicatriz/etiologia , Cicatriz/fisiopatologia , Meios de Contraste/administração & dosagem , Feminino , Fibrose , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento
15.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 1111-1114, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30440584

RESUMO

The use of implantable cardiac devices has increased in the last 30 years. Cardiac resynchronisation therapy (CRT) is a procedure which involves implanting a coin sized pacemaker for reversing heart failure. The pacemaker electrode leads are implanted into cardiac myocardial tissue. The optimal site for implantation is highly patient-specific. Most implanters use empirical placement of the lead. One region identified to have a poor response rate are myocardial tissue with transmural scar. Studies that precisely measure transmurality of scar tissue in the left ventricle (LV) are few. Most studies lack proper validation of their transmurality measurement technique. This study presents an image analysis technique for computing scar transmurality from late-gadolinium enhancement MRI. The technique is validated using phantoms under a CRT image guidance system. The study concludes that scar transmurality can be accurately measured in certain situations and validation with phantoms is important.


Assuntos
Terapia de Ressincronização Cardíaca , Cicatriz , Meios de Contraste , Análise de Dados , Gadolínio , Insuficiência Cardíaca , Humanos , Imageamento por Ressonância Magnética , Resultado do Tratamento
16.
Med Image Anal ; 50: 36-53, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30208355

RESUMO

Structural changes to the wall of the left atrium are known to occur with conditions that predispose to Atrial fibrillation. Imaging studies have demonstrated that these changes may be detected non-invasively. An important indicator of this structural change is the wall's thickness. Present studies have commonly measured the wall thickness at few discrete locations. Dense measurements with computer algorithms may be possible on cardiac scans of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI). The task is challenging as the atrial wall is a thin tissue and the imaging resolution is a limiting factor. It is unclear how accurate algorithms may get and how they compare in this new emerging area. We approached this problem of comparability with the Segmentation of Left Atrial Wall for Thickness (SLAWT) challenge organised in conjunction with MICCAI 2016 conference. This manuscript presents the algorithms that had participated and evaluation strategies for comparing them on the challenge image database that is now open-source. The image database consisted of cardiac CT (n=10) and MRI (n=10) of healthy and diseased subjects. A total of 6 algorithms were evaluated with different metrics, with 3 algorithms in each modality. Segmentation of the wall with algorithms was found to be feasible in both modalities. There was generally a lack of accuracy in the algorithms and inter-rater differences showed that algorithms could do better. Benchmarks were determined and algorithms were ranked to allow future algorithms to be ranked alongside the state-of-the-art techniques presented in this work. A mean atlas was also constructed from both modalities to illustrate the variation in thickness within this small cohort.


Assuntos
Átrios do Coração/anatomia & histologia , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Algoritmos , Fibrilação Atrial , Bioestatística , Bases de Dados Factuais , Humanos , Variações Dependentes do Observador
17.
J Cardiovasc Magn Reson ; 20(1): 30, 2018 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-29720202

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) imaging may be used to visualize post-ablation atrial scar (PAAS), and three-dimensional late gadolinium enhancement (3D LGE) is the most widely employed technique for imaging of chronic scar. Detection of PAAS provides a unique non-invasive insight into the effects of the ablation and may help guide further ablation procedures. However, there is evidence that PAAS is often not detected by CMR, implying a significant sensitivity problem, and imaging parameters vary between leading centres. Therefore, there is a need to establish the optimal imaging parameters to detect PAAS. METHODS: Forty subjects undergoing their first pulmonary vein isolation procedure for AF had detailed CMR assessment of atrial scar: one scan pre-ablation, and two scans post-ablation at 3 months (separated by 48 h). Each scan session included ECG- and respiratory-navigated 3D LGE acquisition at 10, 20 and 30 min post injection of a gadolinium-based contrast agent (GBCA). The first post-procedural scan was performed on a 1.5 T scanner with standard acquisition parameters, including double dose (0.2 mmol/kg) Gadovist and 4 mm slice thickness. Ten patients subsequently underwent identical scan as controls, and the other 30 underwent imaging with a reduced, single, dose GBCA (n = 10), half slice thickness (n = 10) or on a 3 T scanner (n = 10). Apparent signal-to-noise (aSNR), contrast-to-noise (aCNR) and imaging quality (Likert Scale, 3 independent observers) were assessed. PAAS location and area (%PAAS scar) were assessed following manual segmentation. Atrial shells with standardised %PAAS at each timepoint were then compared to ablation lesion locations to assess quality of scar delineation. RESULTS: A total of 271 3D acquisitions (out of maximum 280, 96.7%) were acquired. Likert scale of imaging quality had high interobserver and intraobserver intraclass correlation coefficients (0.89 and 0.96 respectively), and showed lower overall imaging quality on 3 T and at half-slice thickness. aCNR, and quality of scar delineation increased significantly with time. aCNR was higher with reduced, single, dose of GBCA (p = 0.005). CONCLUSION: 3D LGE CMR atrial scar imaging, as assessed qualitatively and quantitatively, improves with time from GBCA administration, with some indices continuing to improve from 20 to 30 min. Imaging should be performed at least 20 min post-GBCA injection, and a single dose of contrast should be considered. TRIAL REGISTRATION: Trial registry- United Kingdom National Research Ethics Service 08/H0802/68 - 30th September 2008.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Cicatriz/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Imagem Cinética por Ressonância Magnética , Compostos Organometálicos/administração & dosagem , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Cicatriz/etiologia , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
18.
Med Image Anal ; 47: 153-163, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29753180

RESUMO

Biophysical models of the atrium provide a physically constrained framework for describing the current state of an atrium and allow predictions of how that atrium will respond to therapy. We propose a work flow to simulate patient specific electrophysiological heterogeneity from clinical data and validate the resulting biophysical models. In 7 patients, we recorded the atrial anatomy with an electroanatomical mapping system (St Jude Velocity); we then applied an S1-S2 electrical stimulation protocol from the coronary sinus (CS) and the high right atrium (HRA) whilst recording the activation patterns using a PentaRay catheter with 10 bipolar electrodes at 12 ±â€¯2 sites across the atrium. Using only the activation times measured with a PentaRay catheter and caused by a stimulus applied in the CS with a remote catheter we fitted the four parameters for a modified Mitchell-Schaeffer model and the tissue conductivity to the recorded local conduction velocity restitution curve and estimated local effective refractory period. Model parameters were then interpolated across each atrium. The fitted model recapitulated the S1-S2 activation times for CS pacing giving a correlation ranging between 0.81 and 0.98. The model was validated by comparing simulated activations times with the independently recorded HRA pacing S1-S2 activation times, giving a correlation ranging between 0.65 and 0.96. The resulting work flow provides the first validated cohort of models that capture clinically measured patient specific electrophysiological heterogeneity.


Assuntos
Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco , Mapeamento Epicárdico/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiologia , Fluxo de Trabalho , Algoritmos , Estimulação Cardíaca Artificial , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Modelos Cardiovasculares
19.
J Cardiovasc Magn Reson ; 20(1): 21, 2018 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-29554919

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) imaging has been used to visualise post-ablation atrial scar (PAAS), generally employing a three-dimensional (3D) late gadolinium enhancement (LGE) technique. However the reproducibility of PAAS imaging has not been determined. This cross-over study is the first to investigate the reproducibility of the technique, crucial for both future research design and clinical implementation. METHODS: Forty subjects undergoing first time ablation for atrial fibrillation (AF) had detailed CMR assessment of PAAS. Following baseline pre-ablation scan, two scans (separated by 48 h) were performed at three months post-ablation. Each scan session included 3D LGE acquisition at 10, 20 and 30 min post administration of gadolinium-based contrast agent (GBCA). Subjects were allocated at second scan post-ablation to identical imaging parameters ('Repro', n = 10), 3 T scanner ('3 T', n = 10), half-slice thickness ('Half-slice', n = 10) or half GBCA dose ('Half-gad', n = 10). PAAS was compared to baseline scar and then reproducibility was assessed for two measures of thresholded scar (% left atrial (LA) occupied by PAAS (%LA PAAS) and Pulmonary Vein Encirclement (PVE)), and then four measures of non-thresholded scar (point-by-point assessment of PAAS, four normalisation methods). Thresholded measures of PAAS were evaluated against procedural outcome (AF recurrence). RESULTS: A total of 271 3D acquisitions (out of maximum 280, 96.7%) were acquired. At 20 and 30 min, inter-scan reproducibility was good to excellent (coefficient of variation at 20 min and 30 min: %LA PAAS 0.41 and 0.20; PVE 0.13 and 0.04 respectively for 'Repro' group). Changes in imaging parameters, especially reduced GBCA dose, reduced inter-scan reproducibility, but for most measures remained good to excellent (ICC for %LA PAAS 0.454-0.825, PVE 0.618-0.809 at 30 min). For non-thresholded scar, highest reproducibility was observed using blood pool z-score normalisation technique: inter-scan ICC 0.759 (absolute agreement, 'Repro' group). There was no significant relationship between indices of PAAS and AF recurrence. CONCLUSION: PAAS imaging is a reproducible finding. Imaging should be performed at least 20 min post-GBCA injection, and a blood pool z-score should be considered for normalisation of signal intensities. The clinical implications of these findings remain to be established in the absence of a simple correlation with arrhythmia outcome. TRIAL REGISTRATION: United Kingdom National Research Ethics Service 08/H0802/68 - 30th September 2008.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Cicatriz/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Imagem Cinética por Ressonância Magnética , Compostos Organometálicos/administração & dosagem , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Cicatriz/etiologia , Cicatriz/patologia , Cicatriz/fisiopatologia , Estudos Cross-Over , Feminino , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Valor Preditivo dos Testes , Recidiva , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
20.
PLoS One ; 13(1): e0189936, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29293545

RESUMO

AIMS: To test the ability of four circulating biomarkers of fibrosis, and of low left atrial voltage, to predict recurrence of atrial fibrillation after catheter ablation. BACKGROUND: Circulating biomarkers potentially may be used to improve patient selection for atrial fibrillation ablation. Low voltage areas in the left atrium predict arrhythmia recurrence when mapped in sinus rhythm. This study tested type III procollagen N terminal peptide (PIIINP), galectin-3 (gal-3), fibroblast growth factor 23 (FGF-23), and type I collagen C terminal telopeptide (ICTP), and whether low voltage areas in the left atrium predicted atrial fibrillation recurrence, irrespective of the rhythm during mapping. METHODS: 92 atrial fibrillation ablation patients were studied. Biomarker levels in peripheral and intra-cardiac blood were measured with enzyme-linked immunosorbent assay. Low voltage (<0.5mV) was expressed as a proportion of the mapped left atrial surface area. Follow-up was one year. The primary endpoint was recurrence of arrhythmia. The secondary endpoint was a composite of recurrence despite two procedures, or after one procedure if no second procedure was undertaken. RESULTS: The biomarkers were not predictive of either endpoint. After multivariate Cox regression analysis, high proportion of low voltage area in the left atrium was found to predict the primary endpoint in sinus rhythm mapping (hazard ratio 4.323, 95% confidence interval 1.337-13.982, p = 0.014) and atrial fibrillation mapping (hazard ratio 5.195, 95% confidence interval 1.032-26.141, p = 0.046). This effect was also apparent for the secondary endpoint. CONCLUSION: The studied biomarkers do not predict arrhythmia recurrence after catheter ablation. Left atrial voltage is an independent predictor of recurrence, whether the left atrium is mapped in atrial fibrillation or sinus rhythm.


Assuntos
Fibrilação Atrial/cirurgia , Biomarcadores/sangue , Ablação por Cateter/métodos , Átrios do Coração/fisiopatologia , Adulto , Idoso , Fibrilação Atrial/fisiopatologia , Proteínas Sanguíneas , Colágeno Tipo I/sangue , Feminino , Fator de Crescimento de Fibroblastos 23 , Fatores de Crescimento de Fibroblastos/sangue , Fibrose , Galectina 3/sangue , Galectinas , Humanos , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/sangue , Peptídeos/sangue , Pró-Colágeno/sangue , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...