Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 32(6): 10618-10629, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38571268

RESUMO

In this article we demonstrate rapid manufacturing of an illumination quality double-sided centimeter-scale optics without any post-processing. Two methods are presented: additive manufacturing (AM) using an optically transparent material with a water-soluble support material (support method), and alternatively, using only the optically transparent material but flipping the optics mid-process (flipping method). The main advantage of the flipping method is that only one material is needed. However, the use of support material is more straightforward, allows better alignment between the two sides of the lens and enables more complex lenses manufactured in the future. Both methods result in sufficient surface quality, i.e. surface roughness Rq = 11.48 ±3.32 nm and form accuracy of ±10 µm, for the purposes of illumination optics.

2.
ACS Appl Nano Mater ; 6(6): 4770-4781, 2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-37006910

RESUMO

We propose a simple, fast, and low-cost method for producing Au-coated black Si-based SERS-active substrates with a proven enhancement factor of 106. Room temperature reactive ion etching of silicon wafer followed by nanometer-thin gold sputtering allows the formation of a highly developed lace-type Si surface covered with homogeneously distributed gold islands. The mosaic structure of deposited gold allows the use of Au-uncovered Si domains for Raman peak intensity normalization. The fabricated SERS substrates have prominent uniformity (with less than 6% SERS signal variations over large areas, 100 × 100 µm2). It has been found that the storage of SERS-active substrates in an ambient environment reduces the SERS signal by less than 3% in 1 month and not more than 40% in 20 months. We showed that Au-coated black Si-based SERS-active substrates can be reused after oxygen plasma cleaning and developed relevant protocols for removing covalently bonded and electrostatically attached molecules. Experiments revealed that the Raman signal of 4-MBA molecules covalently bonded to the Au coating measured after the 10th cycle was just 4 times lower than that observed for the virgin substrate. A case study of the reusability of the black Si-based substrate was conducted for the subsequent detection of 10-5 M doxorubicin, a widely used anticancer drug, after the reuse cycle. The obtained SERS spectra of doxorubicin were highly reproducible. We demonstrated that the fabricated substrate permits not only qualitative but also quantitative monitoring of analytes and is suitable for the determination of concentrations of doxorubicin in the range of 10-9-10-4 M. Reusable, stable, reliable, durable, low-cost Au-coated black Si-based SERS-active substrates are promising tools for routine laboratory research in different areas of science and healthcare.

3.
Nano Lett ; 22(10): 3879-3883, 2022 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-35506595

RESUMO

Plasmonic metasurfaces exhibiting collective responses known as surface lattice resonances (SLRs) show potential for realizing flat photonic components for wavelength-selective processes, including lasing and optical nonlinearities. However, postfabrication tuning of SLRs remains challenging, limiting the applicability of SLR-based components. Here, we demonstrate how the properties of high quality factor SLRs are easily modified by breaking the symmetry of the nanoparticle surroundings. We break the symmetry by changing the refractive index of the overlying immersion oil by controlling the ambient temperature of the device. We show that a modest temperature change of 10 °C can increase the quality factor of the SLR from 400 to 750. Our results demonstrate accurate and reversible modification of the properties of the investigated SLRs, paving the way toward tunable SLR-based photonic devices. More generally, we show how symmetry breaking of the environment can be utilized for efficient and potentially ultrafast modification of the SLR properties.

4.
Opt Express ; 30(3): 3620-3631, 2022 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-35209616

RESUMO

Nonlinear metamaterials show potential for realizing flat nonlinear optical devices but are generally lacking in terms of achievable conversion efficiencies. Recent work has focused on enhancing nonlinear processes by utilizing high quality factor resonances, such as collective responses known as surface lattice resonances (SLRs) taking place in periodic metal nanoparticle arrays. Here, we investigate how the dispersive nature of SLRs affects the nonlinear responses of SLR-supporting metasurfaces. Particularly, we measure second-harmonic generation from aluminum nanoparticle arrays and demonstrate that by tilting the sample along two orthogonal directions, the sample can be made multiply-resonant for several pump and second-harmonic signal wavelength combinations. Characterized metasurfaces are estimated to exhibit a second-order susceptibility value of 0.40 pm/V, demonstrating aluminum as a potential material for nonlinear metasurfaces.

5.
Opt Lett ; 47(4): 1009-1012, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35167581

RESUMO

Nanograting-based plasmonic sensors are widely regarded as promising platforms due to their real-time label-free detection and ease of integration. However, many reported grating structures are too complicated to fabricate, which limits their application. We propose a 1D bilayer metallic grating with trapezoidal profile as a near-infrared plasmonic sensor in the spectral interrogation. Trapezoidal gratings tend to perform better than rectangular gratings as sensors, particularly as they can detect at oblique incidence to obtain higher performance. Furthermore, we have successfully fabricated such a grating with a period of 633 nm over a 2.25 cm2 area using a two-step approach based on laser interference lithography. Glucose detection has been conducted to experimentally validate the sensing performance of the as-prepared grating. The measured sensitivity and figure-of-merit can reach up to 786 nm/RIU and 30, respectively. Our research sheds new light on the development of cost-effective sensing devices.


Assuntos
Lasers , Impressão , Luz
6.
J Synchrotron Radiat ; 28(Pt 6): 1978-1984, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34738953

RESUMO

The performance and parameters of the online photon single-shot spectrometer (PSSS) at the Aramis beamline of the SwissFEL free-electron laser are presented. The device operates between the photon energies 4 and 13 keV and uses diamond transmission gratings and bent Si crystals for spectral measurements on the first diffraction order of the beam. The device has an energy window of 0.7% of the median photon energy of the free-electron laser pulses and a spectral resolution (full width at half-maximum) ΔE/E on the order of 10-5. The device was characterized by comparing its performance with reference data from synchrotron sources, and a parametric study investigated other effects that could affect the reliability of the spectral information.

7.
Nanotechnology ; 33(9)2021 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-34818632

RESUMO

In living organisms, redox reactions play a crucial role in the progression of disorders accompanied by the overproduction of reactive oxygen and reactive chlorine species, such as hydrogen peroxide and hypochlorous acid, respectively. We demonstrate that green fluorescence graphene quantum dots (GQDs) can be employed for revealing the presence of the hypochlorous acid in aqueous solutions and cellular systems. Hypochlorous acid modifies the oxygen-containing groups of the GQD, predominantly opens epoxide ring C-O-C, forms excessive C=O bonds and damages the carbonic core of GQDs. These changes, which depend on the concentration of the hypochlorous acid and exposure time, manifest themselves in the absorbance and fluorescence spectra of the GQD, and in the fluorescence lifetime. We also show that the GQD fluorescence is not affected by hydrogen peroxide. This finding makes GQDs a promising sensing agent for selective detecting reactive chlorine species produced by neutrophils. Neutrophils actively accumulate GQDs allowing to visualize cells and to examine the redox processes via GQDs fluorescence. At high concentrations GQDs induce neutrophil activation and myeloperoxidase release, leading to the disruption of GQD structure by the produced hypochlorous acid. This makes the GQDs a biodegradable material suitable for various biomedical applications.


Assuntos
Técnicas Biossensoriais/métodos , Corantes Fluorescentes , Ácido Hipocloroso , Neutrófilos , Pontos Quânticos , Células Cultivadas , Corantes Fluorescentes/análise , Corantes Fluorescentes/química , Corantes Fluorescentes/metabolismo , Grafite/química , Humanos , Ácido Hipocloroso/análise , Ácido Hipocloroso/metabolismo , Microscopia de Fluorescência , Neutrófilos/química , Neutrófilos/metabolismo , Peroxidase/metabolismo , Pontos Quânticos/análise , Pontos Quânticos/química , Pontos Quânticos/metabolismo
8.
Opt Express ; 28(18): 26509-26518, 2020 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-32906923

RESUMO

We demonstrate optically induced crossover from a weak to a strong coupling regime in a single photonic system consisting of propagating surface plasmon polaritons (SPPs) on a planar silver film and ultraviolet (UV)-switchable photochromic molecules. A gradual increase is observed in the vacuum Rabi splitting upon increasing UV exposure, along with intriguing behavior, where the reflectivity initially decreases due to increased losses at the weak coupling regime, and then increases due to the emergence of strongly coupled modes and the associated band gap formation at the resonance frequency of the uncoupled states. This work explicitly demonstrates the optical tunability of the degree of hybridization of the SPP and exciton modes, spanning the range from weak to intermediate and finally to the strong coupling regime.

9.
Opt Express ; 27(21): 30031-30043, 2019 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-31684257

RESUMO

Plasmonic oligomers can provide profound Fano resonance in their scattering responses. The sub-radiant mode of Fano resonance can result in significant near-field enhancement due to its light trapping capability into the so-called hotspots. Appearance of these highly localized hotspots at the excitation and/or Stokes wavelengths of the analytes makes such oligomers promising SERS active substrates. In this work, we numerically and experimentally investigate optical properties of two disk-type gold oligomers, which have different strength and origin of Fano resonance. Raman analysis of rhodamine 6G and adenine with the presence of the fabricated oligomers clearly indicates that an increment in the strength of Fano resonance can improve the Raman enhancement of an oligomer significantly. Therefore, by suitable engineering of Fano lineshape, one can achieve efficient SERS active substrates with spatially localized hotspots.

10.
Struct Dyn ; 3(3): 034301, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26958586

RESUMO

We report a method for achieving advanced photon diagnostics of x-ray free-electron lasers (XFELs) under a quasi-noninvasive condition by using a beam-splitting scheme. Here, we used a transmission grating to generate multiple branches of x-ray beams. One of the two primary diffracted branches (+1st-order) is utilized for spectral measurement in a dispersive scheme, while the other (-1st-order) is dedicated for arrival timing diagnostics between the XFEL and the optical laser pulses. The transmitted x-ray beam (0th-order) is guided to an experimental station. To confirm the validity of this timing-monitoring scheme, we measured the correlation between the arrival timings of the -1st and 0th branches. The observed error was as small as 7.0 fs in root-mean-square. Our result showed the applicability of the beam branching scheme to advanced photon diagnostics, which will further enhance experimental capabilities of XFEL.

11.
Opt Lett ; 41(2): 281-4, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26766694

RESUMO

The focusing efficiency of conventional diffractive x-ray lenses is fundamentally limited due to their symmetric binary structures and the corresponding symmetry of their focusing and defocusing diffraction orders. Fresnel zone plates with asymmetric structure profiles can break this limitation; yet existing implementations compromise either on resolution, ease of use, or stability. We present a new way for the fabrication of such blazed lenses by patterning two complementary binary Fresnel zone plates on the front and back sides of the same membrane chip to provide a compact, inherently stable, single-chip device. The presented blazed double-sided zone plates with 200 nm smallest half-pitch provide up to 54.7% focusing efficiency at 6.2 keV, which is clearly beyond the value obtainable by their binary counterparts.

12.
Langmuir ; 31(45): 12537-43, 2015 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-26509355

RESUMO

We demonstrate that spatial confinement can be used to control the orientational and translational order of cubic nanoparticles. For this purpose we have combined X-ray scattering and scanning electron microscopy to study the ordering of iron oxide nanocubes that have self-assembled from toluene-based dispersions in nanofluidic channels. An analysis of scattering vector components with directions parallel and perpendicular to the slit walls shows that the confining walls induce a preferential parallel alignment of the nanocube (100) faces. Moreover, slit wall separations that are commensurate with an integer multiple of the edge length of the oleic acid-capped nanocubes result in a more pronounced translational order of the self-assembled arrays compared to incommensurate confinement. These results show that the confined assembly of anisotropic nanocrystals is a promising route to nanoscale devices with tunable anisotropic properties.

13.
Opt Express ; 23(10): 13278-93, 2015 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-26074579

RESUMO

Zernike phase contrast microscopy is a well-established method for imaging specimens with low absorption contrast. It has been successfully implemented in full-field microscopy using visible light and X-rays. In microscopy Cowley's reciprocity principle connects scanning and full-field imaging. Even though the reciprocity in Zernike phase contrast has been discussed by several authors over the past thirty years, only recently it was experimentally verified using scanning X-ray microscopy. In this paper, we investigate the image and contrast formation in scanning Zernike phase contrast microscopy with a particular and detailed focus on the origin of imaging artifacts that are typically associated with Zernike phase contrast. We demonstrate experimentally with X-rays the effect of the phase mask design on the contrast and halo artifacts and present an optimized design of the phase mask with respect to photon efficiency and artifact reduction. Similarly, due to the principle of reciprocity the observations and conclusions of this work have direct applicability to Zernike phase contrast in full-field microscopy as well.

14.
Opt Express ; 23(2): 776-86, 2015 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-25835837

RESUMO

The fabrication of high aspect ratio metallic nanostructures is crucial for the production of efficient diffractive X-ray optics in the hard X-ray range. We present a novel method to increase their structure height via the double-sided patterning of the support membrane. In transmission, the two Fresnel zone plates on the two sides of the substrate will act as a single zone plate with added structure height. The presented double-sided zone plates with 30 nm smallest zone width offer up to 9.9% focusing efficiency at 9 keV, that results in a factor of two improvement over their previously demonstrated single-sided counterparts. The increase in efficiency paves the way to speed up X-ray microscopy measurements and allows the more efficient utilization of the flux in full-field X-ray microscopy.

15.
Opt Express ; 22(14): 16676-85, 2014 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-25090486

RESUMO

A nano-focusing module based on two linear Fresnel zone plates is presented. The zone plates are designed to generate a kinoform phase profile in tilted geometry, thus overcoming the efficiency limitations of binary diffractive structures. Adjustment of the tilt angle enables tuning of the setup for optimal efficiency over a wide range of photon energies, ranging from 5 to 20 keV. Diffraction efficiency of more than 50% was measured for the full module at 8 keV photon energy. A diffraction limited spot size of 100 nm was verified by ptychographic reconstruction for a lens module with a large entrance aperture of 440 µm × 400 µm.

16.
Opt Express ; 22(12): 14859-70, 2014 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-24977581

RESUMO

The smaller pixel size and high frame rate of next-generation photon counting pixel detectors opens new opportunities for the application of X-ray coherent diffractive imaging (CDI). In this manuscript we demonstrate fast image acquisition for ptychography using an Eiger detector. We achieve above 25,000 resolution elements per second, or an effective dwell time of 40 µs per resolution element, when imaging a 500 µm × 290 µm region of an integrated electronic circuit with 41 nm resolution. We further present the application of a scheme of sharing information between image parts that allows the field of view to exceed the range of the piezoelectric scanning system and requirements on the stability of the illumination to be relaxed.

17.
J Synchrotron Radiat ; 21(Pt 3): 497-501, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24763638

RESUMO

High-efficiency nanofocusing of hard X-rays using stacked multilevel Fresnel zone plates with a smallest zone width of 200 nm is demonstrated. The approach is to approximate the ideal parabolic lens profile with two-, three-, four- and six-level zone plates. By stacking binary and three-level zone plates with an additional binary zone plate, the number of levels in the optical transmission function was doubled, resulting in four- and six-level profiles, respectively. Efficiencies up to 53.7% focusing were experimentally obtained with 6.5 keV photons using a compact alignment apparatus based on piezoelectric actuators. The measurements have also been compared with numerical simulations to study the misalignment of the two zone plates.

18.
Opt Lett ; 37(24): 5073-5, 2012 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-23258009

RESUMO

We present a spectrometer setup based on grating dispersion for hard x-ray free-electron lasers. This setup consists of a focusing spectrometer grating and a charge-integrating microstrip detector. Measurement results acquired at Linac Coherent Light Source are presented, demonstrating noninvasive monitoring of single-shot spectra with a resolution of 2.0×10(-4) ±0.3×10(-4) at photon energy of 6 keV with more than 95% transmission of the main beam.

19.
Opt Express ; 18(13): 13444-50, 2010 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-20588475

RESUMO

Three variants of binary blazed gratings with subwavelength features are considered, which have high first-order efficiencies in the non-paraxial domain for arbitrarily polarized light. A combination of effective medium theory and further parametric optimization with the Fourier modal method are used in design. Experimental demonstration is provided by electron beam lithography on a structure etched in a Si3N4 layer on top of a SiO2 substrate, with period approximately 3.5lambda at lambda = 633 nm. The measured efficiency (81% for TE and 85% for TM polarization) agrees well with the calculated value, 84%.


Assuntos
Elétrons , Microscopia/métodos , Modelos Teóricos , Óptica e Fotônica/métodos , Calibragem , Desenho de Equipamento , Análise de Fourier , Microscopia Eletrônica de Varredura , Dióxido de Silício
20.
Opt Express ; 18(10): 10557-66, 2010 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-20588908

RESUMO

The interferogram of a high index phase mask of 200 nm period under normal incidence of a collimated beam at 244 nm wavelength with substantially suppressed zeroth order produces a 100 nm period grating in a resist film under immersion. The paper describes the phase mask design, its fabrication, the effect of electron-beam lithographic stitching errors and optical assessment of the fabricated sub-cutoff grating.


Assuntos
Nanotecnologia/instrumentação , Fotografação/instrumentação , Refratometria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...