Circ J ; 88(7): 1147-1154, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38311419

RESUMO

BACKGROUND: High shock impedance is associated with conversion failure among patients with subcutaneous implantable cardioverter defibrillators (S-ICD). Currently, there is no preoperative assessment method for predicting high shock impedance. This study examined the efficacy of chest computed tomography (CT) as a preoperative evaluation tool to assess the shock impedance of S-ICDs.Methods and Results: The amount of adipose tissue adjacent to the device and anteroposterior diameter at the basal heart region were measured preoperatively using chest CT. We examined the correlation between these measurements and shock impedance at the conversion test. We enrolled 43 patients with S-ICDs (mean [±SD] age 54±15 years; body mass index 23±4 kg/m2; PRAETORIAN score 30-270 points; amount of adipose tissue 1,250±716 cm3), who underwent intraoperative conversion tests by inducing ventricular fibrillation, which was terminated with a 65-J shock. A sufficient concordance correlation coefficient was observed between the shock impedance and the amount of adipose tissue (r=0.616, P<0.01) and anteroposterior diameter (r=0.645, P<0.01). In multiple regression analysis, the amount of adipose tissue (ß=0.439, P=0.009) and anteroposterior diameter (ß=0.344, P=0.038) were identified as independent predictive factors of shock impedance. CONCLUSIONS: The preoperative CT-measured amount of adipose tissue and basal heart anteroposterior diameter are independent predictors of shock impedance. These parameters may be more accurate in identifying higher shock impedance in patients with S-ICDs.


Assuntos
Desfibriladores Implantáveis , Impedância Elétrica , Tomografia Computadorizada por Raios X , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Idoso , Adulto , Tecido Adiposo/diagnóstico por imagem , Fibrilação Ventricular/terapia , Fibrilação Ventricular/diagnóstico por imagem , Fibrilação Ventricular/fisiopatologia , Valor Preditivo dos Testes
2.
Int Heart J ; 64(6): 1157-1161, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-37967987

RESUMO

A 59-year-old man who had been diagnosed with human immunodeficiency virus-associated cardiomyopathy was referred for catheter ablation of ventricular tachycardia (VT). An electrocardiogram (ECG) waveform revealed that the clinical VT originated from the epicardium. A deceleration zone (DZ) was identified on an isochronal late activation map. Moreover, 2 forms of monomorphic VT were induced by different cycle length burst pacings from near the DZ. The morphologies of the 2 VTs with an identical cycle length were very likely to use a shared common pathway with bi-directional conduction around the slow conduction area in the left ventricle posterolateral small epicardial surface area. After ablation of the DZ, the VT was uninducible.


Assuntos
Cardiomiopatias , Ablação por Cateter , Taquicardia Ventricular , Masculino , Humanos , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Frequência Cardíaca/fisiologia , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Resultado do Tratamento
4.
Circ J ; 85(8): 1265-1272, 2021 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-33790146

RESUMO

BACKGROUND: The optimum cut-off value of premature atrial contraction (PAC) burden (CV-PACb) in 24-h Holter electrocardiography (24-h ECG) for predicting atrial fibrillation (AF) is debatable, with few validation data.Methods and Results:We retrospectively analyzed 61 patients already diagnosed with AF (AD-AF) and 147 patients never diagnosed with AF (ND-AF), aged ≥50 years, free of heart disease, and who had undergone 24-h ECG and transthoracic echocardiography (TTE). Receiver operating characteristic analysis demonstrated that 0.4% was the optimal CV-PACb differentiating AD-AF from ND-AF, with 69% sensitivity and 72% specificity (area under the curve [AUC] 0.72; 95% confidence interval [CI] 0.65-0.79); however, the left atrial volume index was not significant (AUC 0.60; 95% CI 0.51-0.68). To verify the CV-PACb, new propensity-matched cohorts (i.e., subjects with a PAC burden ≥0.4% and <0.4%; n=69 in each group) were compared based on new detection of AF at a median follow-up of 50 months (interquartile range 12-60 months) Multivariable Cox regression analysis revealed that among 24-h ECG and TTE findings, only PAC burden ≥0.4% was independently associated with incident AF (hazard ratio 5.28; 95% CI 1.28-26.11; P=0.023). CONCLUSIONS: A high PAC burden (≥0.4%) in 24-h ECG was a reliable indicator to identify undiagnosed AF, whereas TTE parameters did not show any predictive value.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/diagnóstico , Complexos Atriais Prematuros/diagnóstico , Eletrocardiografia , Eletrocardiografia Ambulatorial , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Pontuação de Propensão , Estudos Retrospectivos , Fatores de Risco
5.
Circ J ; 83(10): 2002-2009, 2019 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-31462585

RESUMO

BACKGROUND: An adaptive cardiac resynchronization therapy (aCRT) algorithm has been described for synchronized left ventricular (LV) pacing and continuous optimization of cardiac resynchronization therapy (CRT). However, there are few algorithmic data on the effect of changes during exercise.Methods and Results:We enrolled 27 patients with availability of the aCRT algorithm. Eligible patients were manually programmed to optimal atrioventricular (AV) and interventricular (VV) delays by using echocardiograms at rest or during 2 stages of supine bicycle exercise. We compared the maximum cardiac output between manual echo-optimization and aCRT-on during each phase. After initiating exercise, the optimal AV delay progressively shortened (P<0.05) with incremental exercise levels. The manual-optimized settings and aCRT resulted in similar cardiac performance, as demonstrated by a high concordance correlation coefficient between the LV outflow tract velocity time integral (LVOT-VTI) during each exercise stage (Ex.1: r=0.94 P<0.0008, Ex.2: r=0.88 P<0.001, respectively). Synchronized LV-only pacing in patients with normal AV conduction could provide a higher LVOT-VTI as compared with manual-optimized conventional biventricular pacing at peak exercise (P<0.05). CONCLUSIONS: The aCRT algorithm was physiologically sound during exercise by patients.


Assuntos
Algoritmos , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Tolerância ao Exercício , Insuficiência Cardíaca/terapia , Hemodinâmica , Processamento de Sinais Assistido por Computador , Terapia Assistida por Computador/instrumentação , Função Ventricular Esquerda , Adaptação Fisiológica , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Doppler de Pulso , Ecocardiografia sob Estresse , Teste de Esforço , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
6.
Clin J Gastroenterol ; 9(6): 345-351, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27624750

RESUMO

A 77-year-old woman underwent an upper gastrointestinal (UGI) endoscopy screening examination, and a 10-mm reddish, submucosal tumor-like lesion was found on the posterior wall of the fornix. Biopsy was performed, but there was no evidence of malignancy, so annual follow-up by UGI endoscopy was decided upon. After 12 years, examination of another biopsy specimen revealed an adenocarcinoma of the fundic gland type. There had been no significant change in the size or shape of the lesion over the long follow-up period. Endoscopic submucosal dissection (ESD) was performed, and en bloc resection was achieved. Histopathologically, the tumor appeared as a flat elevated lesion measuring 11 × 10 mm. It was composed of irregularly shaped glands and invaded the submucosa up to 300 µm. Immunohistochemical examination involving specific antibodies to pepsinogen I, MIST-1, MUC6, and H+/K+-ATPase confirmed the fundic gland differentiation of the irregularly shaped glands together with a very low Ki-67 labeling index. Thus, gastric adenocarcinoma of the fundic gland type (GAFG) was diagnosed. Four years have passed since the ESD, and there has been no recurrence. To the best of our knowledge, this is the first report of the long-term natural history of GAFG. Over the 12 years, no morphologic changes were observed; the tumor remained within the submucosal layer. Our observations in this case strengthen the notion that GAFG is a specific type of gastric adenocarcinoma of low-grade malignancy.