1.
J Med Invest ; 71(1.2): 141-147, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38735710

RESUMO

CapeOX is a regimen used as postoperative adjuvant chemotherapy for the treatment of advanced recurrent colorectal cancer. If early adverse events occur, treatment may not progress as planned and further dose reduction may be necessary. In this study, we investigated whether pre-treatment medical records could be used to predict adverse events in order to prevent adverse events caused by CapeOX treatment. The 178 patients were classified into two groups (97 in the adverse event positive group and 81 in the adverse event-negative group) based on withdrawal or postponement of four or fewer courses. In univariate analysis, age, height, weight, body surface area (BSA), creatinine clearance, muscle mass, and lean body mass were associated with early adverse events (P<0.05). The area under the receiver operating characteristic curve obtained by Stepwise logistic regression analysis using the Akaike information criterion method was 0.832. For nested k-fold cross validation, the accuracy rates of the support vector machine, random forest, and logistic regression algorithms were 0.71, 0.70, and 0.75, respectively. The results of the present study suggest that a logistic regression prediction model may be useful in predicting early adverse events caused by CapeOX therapy in patients with colorectal cancer. J. Med. Invest. 71 : 141-147, February, 2024.


Assuntos
Neoplasias Colorretais , Humanos , Neoplasias Colorretais/tratamento farmacológico , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Capecitabina/efeitos adversos , Capecitabina/administração & dosagem , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Idoso de 80 Anos ou mais , Adulto , Estudos Retrospectivos
2.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 71(5): 423-7, 2015 May.
Artigo em Japonês | MEDLINE | ID: mdl-25994395

RESUMO

A short length scatterer is adopted to measure the X-ray spectrum of computed tomography (CT) equipment with a wide irradiation field in the body axis direction. The purpose of this study is to compare X-ray spectra measured using different length scatterers and determine the most appropriate length for the scatterer. 320-slice CT equipment (Aquilion ONE) was used in this study. Circular carbonrods (3 cm diameter) with five different lengths (1-16 cm) were used as scatterers. The effect of the beam hardening phenomenon from different length carbon rods was evaluated according to the effective energy. The measurement accuracy for photon information was also evaluated based on the photon count corresponding to the characteristic X-ray. As a result, the beam hardening effect was scarcely observed when the 1 cm long scatterer was used, and the number of the photons measured for the characteristic X-ray was the most. Therefore, it was concluded that the 1 cm long circular carbon rod scatterer was the most suitable.


Assuntos
Carbono , Espalhamento de Radiação , Tomógrafos Computadorizados