Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 26(Pt 5): 1797-1807, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31490172

RESUMO

Flame-retardant polyurethane foams are potential packing materials for the transport casks of highly active nuclear materials for shock absorption and insulation purposes. Exposure of high doses of gamma radiation causes cross-linking and chain sectioning of macromolecules in this polymer foam, which leads to reorganization of their cellular microstructure and thereby variations in physico-mechanical properties. In this study, in-house-developed flame-retardant rigid polyurethane foam samples were exposed to gamma irradiation doses in the 0-20 kGy range and synchrotron radiation X-ray micro-computed tomography (SR-µCT) imaging was employed for the analysis of radiation-induced morphological variations in their cellular microstructure. Qualitative and quantitative analysis of SR-µCT images has revealed significant variations in the average cell size, shape, wall thickness, orientations and spatial anisotropy of the cellular microstructure in polyurethane foam.


Assuntos
Retardadores de Chama/efeitos da radiação , Poliuretanos/efeitos da radiação , Microtomografia por Raio-X/métodos , Raios gama , Ciência dos Materiais/métodos , Doses de Radiação , Síncrotrons
2.
Appl Radiat Isot ; 148: 49-59, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30921617

RESUMO

Ore minerals in dolomites and Graphite Mica Schist (GMS) were studied by synchrotron radiation micro-computed tomography (SR-µCT) and optical microscopy. High resolution µCT images of ore minerals were obtained at Imaging Beamline (BL-4), Indus-2 synchrotron radiation source for the comprehensive volume characterization of minerals. Optical microscopy was used for mineral identification, mineral/rock characterization and quantification of ore mineral assemblages was also confirmed by XRD. 3D images from SR-µCT have shown spatial distribution of major minerals and crystals of different minerals in the volume of samples. The results obtained shows that the GMS and dolomitic hosted rocks mined from region near Udaipur, Rajasthan contains sulfide mineral phases. SR-µCT facilitates visualization of the association of the various metallic minerals with the host rock. The presence of economically important metallic minerals galena, sphalerite and pyrite found in the samples through SR-µCT has implications on exploration and processing of ores.

3.
Rev Sci Instrum ; 88(2): 023702, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28249518

RESUMO

Availability of microfocus X-ray sources and high resolution X-ray area detectors has made it possible for high resolution microtomography studies to be performed outside the purview of synchrotron. In this paper, we present the work towards the use of an external shutter on a high resolution microtomography system using X-ray CCD camera as a detector. During micro computed tomography experiments, the X-ray source is continuously ON and owing to the readout mechanism of the CCD detector electronics, the detector registers photons reaching it during the read-out period too. This introduces a shadow like pattern in the image known as smear whose direction is defined by the vertical shift register. To resolve this issue, the developed system has been incorporated with a synchronized shutter just in front of the X-ray source. This is positioned in the X-ray beam path during the image readout period and out of the beam path during the image acquisition period. This technique has resulted in improved data quality and hence the same is reflected in the reconstructed images.

4.
J Synchrotron Radiat ; 24(Pt 1): 232-239, 2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28009562

RESUMO

Experiments were conducted to study the effects of static magnetic fields (SMFs) on the venation network of soybean leaves using the synchrotron-based X-ray micro-imaging technique. The seeds of soybean (Glycine max, variety JS-335) were pretreated with different SMFs from 50 to 300 mT in steps of 50 mT for 1 h. The phase-contrast images obtained showed that, as the strength of the SMF increased, the area, width of the midrib, area of the midrib and minor vein of the middle leaflets of third trifoliate leaves also increased up to the SMF strength of 200 mT (1 h) and decreased thereafter. Quantification of the major conducting vein also showed the differences in the major and minor vein structures of the soybean leaves as compared with control leaves. Further, the phase-retrieval technique has been applied to make the segmentation process easy and to quantify the major and minor veins in the venation network. The width and area of midrib enhancement by pre-treatment with SMF implies an enhancement in the uptake of water, which in turn causes an increased rate of photosynthesis and stomatal conductance.


Assuntos
Folhas de Planta/química , Síncrotrons , Fotossíntese , Folhas de Planta/fisiologia , Sementes , Glycine max
5.
J Synchrotron Radiat ; 23(Pt 3): 795-801, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27140160

RESUMO

The hydraulic efficiency of a leaf depends on its vascular structure as this is responsible for transport activities. To investigate the effect of exclusion of UVAB and UVB radiation from the solar spectrum on the micro-structure of leaves of soybean (Glycine max, variety JS-335), a field experiment was conducted using synchrotron-based phase contrast imaging (PCI). Plants were grown in specially designed UV exclusion chambers, and wrapped with filters that excluded UVB (280-315 nm) or UVAB (280-400 nm), or transmitted all the ambient solar UV (280-400 nm) radiation (filter control). Qualitative observation of high-resolution X-ray PCI images obtained at 10 keV has shown the differences in major and minor vein structures of the leaves. The mid-rib width of the middle leaflet of third trifoliate leaves, for all treatments, were obtained using quantitative image analysis. The width of the mid-rib of the middle leaflet of third trifoliate leaves of UVB excluded plants was found to be more compared to leaves of filter control plants, which are exposed to ambient UV. The mid-rib or the main conducting vein transports water and sugars to the whole plant; therefore, mid-rib enhancement by the exclusion of solar UV radiation possibly implies enhancement in the leaf area which in turn causes an increased rate of photosynthesis.


Assuntos
Glycine max , Folhas de Planta , Luz Solar , Síncrotrons , Raios Ultravioleta , Raios X
6.
J Xray Sci Technol ; 24(1): 119-32, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26890899

RESUMO

BACKGROUND: Application of high resolution synchrotron micro-imaging in microdefects studies of restored dental samples. OBJECTIVE: The purpose of this study was to identify and compare the defects in restorations done by two different resin systems on teeth samples using synchrotron based micro-imaging techniques namely Phase Contrast Imaging (PCI) and micro-computed tomography (MCT). With this aim acquired image quality was also compared with routinely used RVG (Radiovisiograph). METHODS: Crowns of human teeth samples were fractured mechanically involving only enamel and dentin, without exposure of pulp chamber and were divided into two groups depending on the restorative composite materials used. Group A samples were restored using a submicron Hybrid composite material and Group B samples were restored using a Nano-Hybrid restorative composite material. Synchrotron based PCI and MCT was performed with the aim of visualization of tooth structure, composite resin and their interface. RESULTS: The quantitative and qualitative comparison of phase contrast and absorption contrast images along with MCT on the restored teeth samples shows comparatively large number of voids in Group A samples. CONCLUSIONS: Quality assessment of dental restorations using synchrotron based micro-imaging suggests Nano-Hybrid resin restorations (Group B) are better than Group A.


Assuntos
Resinas Compostas/análise , Resinas Compostas/química , Restauração Dentária Permanente , Análise de Falha de Equipamento/métodos , Microtomografia por Raio-X/métodos , Humanos , Síncrotrons
7.
Appl Radiat Isot ; 108: 133-142, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26722834

RESUMO

SiC coatings are commonly used as oxidation protective materials in high-temperature applications. The operational performance of the coating depends on its microstructure and uniformity. This study explores the feasibility of applying tabletop X-ray micro-CT for the micro-structural characterization of SiC coating. The coating is deposited over the internal surface of pipe structured graphite fuel tube, which is a prototype of potential components of compact high-temperature reactor (CHTR). The coating is deposited using atmospheric pressure chemical vapor deposition (APCVD) and properties such as morphology, porosity, thickness variation are evaluated. Micro-structural differences in the coating caused by substrate distance from precursor inlet in a CVD reactor are also studied. The study finds micro-CT a potential tool for characterization of SiC coating during its future course of engineering. We show that depletion of reactants at larger distances causes development of larger pores in the coating, which affects its morphology, density and thickness.

8.
J Synchrotron Radiat ; 22(6): 1531-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26524319

RESUMO

A full-field hard X-ray imaging beamline (BL-4) was designed, developed, installed and commissioned recently at the Indus-2 synchrotron radiation source at RRCAT, Indore, India. The bending-magnet beamline is operated in monochromatic and white beam mode. A variety of imaging techniques are implemented such as high-resolution radiography, propagation- and analyzer-based phase contrast imaging, real-time imaging, absorption and phase contrast tomography etc. First experiments on propagation-based phase contrast imaging and micro-tomography are reported.

9.
J Synchrotron Radiat ; 15(Pt 1): 100-5, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18097085

RESUMO

Phase-contrast imaging provides enhanced image contrast and is important for non-destructive evaluation of structural materials. In this paper, experimental results on in-line phase-contrast imaging using a synchrotron source (ELETTRA, Italy) for objects required in material science applications are discussed. Experiments have been carried out on two types of samples, pyrocarbon-coated zirconia and pyrocarbon-coated alumina microspheres. These have applications in both reactor and industrial fields. The phase-contrast imaging technique is found to be very useful in visualizing and determining the coating thickness of pyrocarbon on zirconia and alumina microspheres. The experiments were carried out at X-ray energies of 16, 18 and 20 keV and different object-to-detector distances. The results describe the contrast values and signal-to-noise ratio for both samples. A comprehensive study was carried out to determine the thickness of the pyrocarbon coating on zirconia and alumina microspheres of diameter 500 microm. The advantages of phase-contrast images are discussed in terms of contrast and resolution, and a comparison is made with absorption images. The results show considerable improvement in contrast with phase-contrast imaging as compared with absorption radiography.

10.
Rev Sci Instrum ; 78(8): 083703, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17764325

RESUMO

In-line x-ray phase contrast is an emerging x-ray imaging technique that promises to improve the contrast in x-ray imaging process. This technique is most suited for x-ray imaging of soft materials, low atomic number elements such as carbon composite fibers, very thin coatings, etc. We have used this new emerging technique for visualization and characterization of the pyrocarbon coated materials using a combination of microfocus x-ray source and x-ray charge coupled device detector. These studies are important for characterization of coating and optimization of various process parameters during deposition. These experiments will help us to exploit the potential of this technique for studies in other areas of material science such as characterization of carbon fibered structures and detection of cracks and flaws in materials. The characterization of the imaging system and optimization of some process parameters for carbon deposition are also described in detail.


Assuntos
Carbono/química , Aumento da Imagem/instrumentação , Teste de Materiais/instrumentação , Microscopia de Contraste de Fase/instrumentação , Espectrometria por Raios X/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Temperatura Alta , Aumento da Imagem/métodos , Microscopia de Contraste de Fase/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria por Raios X/métodos , Propriedades de Superfície
11.
J Pharm Biomed Anal ; 39(3-4): 517-22, 2005 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-15936912

RESUMO

Ezetimibe belongs to a group of selective and very effective 2-azetidione cholesterol absorption inhibitors that act on the level of cholesterol entry into enterocytes. A rapid, specific reversed-phase HPLC method has been developed for assaying ezetimibe in pharmaceutical dosage forms. The assay involved an isocratic elution of ezetimibe in a Kromasil 100 C18 column using a mobile phase composition of water (pH 6.8, 0.05%, w/v 1-heptane sulfonic acid) and acetonitrile (30:70, v/v). The flow rate was 0.5 ml/min and the analyte monitored at 232 nm. The assay method was found to be linear from 0.5 to 50 microg/ml. All the validation parameters were within the acceptance range. The developed method was successfully applied to estimate the amount of ezetimibe in tablets.


Assuntos
Anticolesterolemiantes/análise , Anticolesterolemiantes/química , Azetidinas/análise , Azetidinas/química , Química Farmacêutica/métodos , Cromatografia Líquida de Alta Pressão/métodos , Indústria Farmacêutica/métodos , Acetonitrilas/química , Calibragem , Relação Dose-Resposta a Droga , Estabilidade de Medicamentos , Enterócitos/metabolismo , Ezetimiba , Heptanos/química , Concentração de Íons de Hidrogênio , Hipercolesterolemia/patologia , Modelos Químicos , Preparações Farmacêuticas/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta , Ácidos Sulfônicos/química , Comprimidos , Temperatura , Fatores de Tempo , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...