Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-18270874

RESUMO

The manipulation of the surgical field in laparoscopic surgery, through small incisions with rigid instruments, reduces free sight, dexterity, and tactile feedback. To help overcome some of these drawbacks, we present a prototype research and development platform, CustusX, for navigation in minimally invasive therapy. The system can also be used for planning and follow-up studies. With this platform we can import and display a range of medical images, also real-time data such as ultrasound and X-ray, during surgery. Tracked surgical tools, such as pointers, video laparoscopes, graspers, and various probes, allow surgeons to interactively control the display of medical images during the procedure. This paper introduces navigation technologies and methods for laparoscopic therapy, and presents our software and hardware research platform. Furthermore, we illustrate the use of the system with examples from two pilots performed during laparoscopic therapy. We also present new developments that are currently being integrated into the system for future use in the operating room. Our initial results from pilot studies using this technology with preoperative images and guidance in the retroperitoneum during laparoscopy are promising. Finally, we shortly describe an ongoing multicenter study using this surgical navigation system platform.


Assuntos
Laparoscopia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Cirurgia Assistida por Computador/instrumentação , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Estudos Multicêntricos como Assunto , Projetos Piloto , Cirurgia Assistida por Computador/métodos , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos , Cirurgia Vídeoassistida/métodos
2.
Surg Endosc ; 18(8): 1242-8, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15457384

RESUMO

BACKGROUND: The main drawback with the laparoscopic approach is that the surgeon is unable to palpate vessels, tumors, and organs during surgery. Furthermore, the laparoscope provides only surface view of organs. There is a need for more advanced visualizations that can enhance the view to include information below the surface of the organs for planning of the procedure and for control and guidance during treatment. METHODS: We propose three-dimensional (3D) navigation technology based on preoperatively acquired magnetic resonance or computed tomography data used in combination with a laparoscopic navigation pointer (LNP). The LNP has an attached position tracker that allows the surgeon to control the display of images interactively before and during surgery. This study evaluated the patient registration accuracy, the feasibility of image-based navigation and, qualitatively, the navigation precision in the retroperitoneum during laparoscopic surgery. RESULTS: This technology was used during the treatment of six patients (involving adrenalectomies and a neuroma protruding into the pelvis). An average patient registration accuracy of 6.90 mm was achieved. The precision during navigation in the retroperitoneum was, in some cases, better than the patient registration accuracy suggested. The technology helped the surgeons to understand better the anatomy and to locate blood vessels. CONCLUSIONS: In the reported cases, the LNP was a useful tool for image guidance in laparoscopic surgery, both for planning the surgical approach in detail and for guidance. The authors believe that adominal 3D image guidance using an LNP has a large potential for improving laparoscopic surgery, especially when vessels and anatomic relations may be difficult to identify using only a laparoscope. Accordingly, they believe this new technology could increase safety and make it easier for the surgeon to perform successful laparoscopic surgery.


Assuntos
Adrenalectomia/métodos , Imageamento Tridimensional/métodos , Laparoscopia/métodos , Sistemas Homem-Máquina , Neuroma/cirurgia , Neoplasias Pélvicas/cirurgia , Adenoma/cirurgia , Neoplasias das Glândulas Suprarrenais/cirurgia , Adrenalectomia/instrumentação , Adulto , Desenho de Equipamento , Humanos , Pessoa de Meia-Idade , Fatores de Tempo , Cirurgia Vídeoassistida/instrumentação , Cirurgia Vídeoassistida/métodos
3.
Cardiovasc Intervent Radiol ; 26(4): 347-56, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14667116

RESUMO

PURPOSE: Three-dimensional (3D) intraoperative ultrasound may be easier to interpret when used in combination with less noisy preoperative image data such as CT. The purpose of this study was to evaluate the use of preoperative image data in a 3D ultrasound-based navigation system specially designed for minimally invasive abdominal surgery. A prototype system has been tested in patients with aortic aneurysms undergoing clinical assessment before and after abdominal aortic stent-graft implantation. METHODS: All patients were first imaged by spiral CT followed by 3D ultrasound scanning. The CT volume was registered to the patient using fiducial markers. This enabled us to compare corresponding slices from 3D ultrasound and CT volumes. The accuracy of the patient registration was evaluated both using the external fiducial markers (artificial landmarks glued on the patient's skin) and using intraoperative 3D ultrasound as a measure of the true positioning of anatomic landmarks inside the body. RESULTS: The mean registration accuracy on the surface was found to be 7.1 mm, but increased to 13.0 mm for specific landmarks inside the body. CT and ultrasound gave supplementary information of surrounding structures and position of the patient's anatomy. Fine-tuning the initial patient registration of the CT data with a multimodal CT to intraoperative 3D ultrasound registration (e.g., mutual information), as well as ensuring no movements between this registration and image guidance, may improve the registration accuracy. CONCLUSION: Preoperative CT in combination with 3D ultrasound might be helpful for guiding minimal invasive abdominal interventions.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção , Aneurisma da Aorta Abdominal/cirurgia , Estudos de Viabilidade , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Cuidados Intraoperatórios , Procedimentos Cirúrgicos Minimamente Invasivos , Cuidados Pré-Operatórios
4.
Cardiovasc Surg ; 9(3): 266-71, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11336850

RESUMO

The purpose is to describe our experience with endovascular treatment of type B aortic dissections. Five patients were treated for complications following type B dissections like, false channel aneurysm formation, rupture and arterial obstruction. They were treated in general anaesthesia using a 'homemade' endoprosthesis or a commercially available endoprosthesis (Excluder) deployed during fluoroscopy. The patients have been followed at regular intervals with a median observation time of 18 months (range 12--36). One patient needed a secondary intervention due to dislodgement of the proximal stentgraft with haemorrhage into both the false and the true lumen. Otherwise there have been no early or late mortality or major complications in this series. Even if our experience with endovascular treatment of type B dissections is rather limited, the results so far are promising. Open surgery in many of these cases is complicated with high morbidity and mortality rate and the endovascular technique offers great advantages. A longer follow-up period is necessary to define the place of endovascular treatment.


Assuntos
Angioplastia/métodos , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Stents , Idoso , Dissecção Aórtica/classificação , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico , Angioplastia/instrumentação , Aneurisma da Aorta Torácica/classificação , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico , Implante de Prótese Vascular/instrumentação , Ecocardiografia Transesofagiana , Fluoroscopia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Resultado do Tratamento
5.
Ultrasound Med Biol ; 27(1): 89-99, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11295275

RESUMO

We introduce a new wavelet-based method for edge detection in ultrasound (US) images. Each beam that is analyzed is first transformed into the wavelet domain using the continuous wavelet transform (CWT). Because the CWT preserves both scale and time information, it is possible to separate the signal into a number of scales. The edge is localized by first determining the scale at which the power spectrum, based on the wavelet transform, has its maximum value. Next, at this scale we find the position of the peak for the squared CWT. This method does not depend on any threshold, after the range of scales have been determined. We suggest a range of scales for US images in general. Sample edge detections are demonstrated in US images of straight and jagged edges of simple structures submerged in water bath, and of an abdominal aorta aneurysm phantom.


Assuntos
Processamento de Sinais Assistido por Computador , Ultrassonografia/métodos , Algoritmos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...