1.
Int Orthop ; 48(3): 643-649, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38015209

RESUMO

PURPOSE: The number of seven required throws per knot was previously reported as providing sufficient security against slippage. A novel high-strength suture featuring dynamic tightening may allow for throw number reduction without compromising stability. The aims of this study were to (1) investigate the influence of the throw number and the effect of different ambient conditions on the knot security of two different high-strength sutures, and (2) compare their biomechanical competence. METHODS: Two sutures (FiberWire (FW) and DynaCord (DC)) were considered for preparing alternating surgical knots. The specimens were stratified for exposure to different media during biomechanical testing-namely air (dry), saline solution (wet), and fat (fatty-wet). A monotonic tensile ramp loading to failure was applied in each test run. For each suture and ambient condition, seven specimens with three to seven throws each were tested (n = 7), evaluating their slippage and ultimate force to failure. The minimum number of throws preventing suture unraveling was determined for each suture type and condition. RESULTS: For each suture type and condition, failure occurred via rupture in all specimens for the following minimum number of throws: FW-dry-7, wet-7, fatty-wet-7; DC-dry-6, wet-4, fatty-wet-5. When applying seven throws, FW demonstrated significantly larger slippage (6.5 ± 2.2 mm) versus DC (3.5 ± 0.4 mm) in wet (p = 0.004) but not in dry and fatty-wet conditions (p ≥ 0.313). CONCLUSIONS: The lower number of throws providing knot security of DC versus FW in the more realistic wet and fatty-wet conditions indicates that the novel DC suture may allow to decrease the foreign body volume and save surgical time without compromising the biomechanical competence.


Assuntos
Técnicas de Sutura , Suturas , Humanos , Teste de Materiais , Resistência à Tração , Ruptura , Técnicas de Sutura/efeitos adversos
2.
Bioengineering (Basel) ; 10(12)2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38135988

RESUMO

OBJECTIVES: As currently there is no existing biomechanical work on the topic of interest, the aim of the current study was to investigate the effect of cerclage banding distally to an intraoperatively occurring proximal periprosthetic femoral clamshell fracture versus a non-fractured femur after total hip arthroplasty. METHODS: A diaphyseal anchoring stem was implanted in twenty paired human cadaveric femora, assigned to a treatment and a control group. In the treatment group, each specimen was fitted with a cerclage band placed 3 mm distally to a clamshell fracture, created with an extent of 40% of the anchoring length of the stem. The resulting fragment was not treated further. The contralateral specimens were left with the stems without further fracture creation or treatment. All constructs were tested under progressively increasing cyclic axial loading until failure. Relative bone-implant movements were monitored by motion tracking. RESULTS: Number of cycles and the corresponding load at stem loosening, defined as 1 mm displacement of the stem along the shaft axis, were 31,417 ± 8870 and 3641.7 ± 887 N in the control group, and 26,944 ± 11,706 and 3194.4 ± 1170.6 N in the treatment group, respectively, with no significant differences between them, p = 0.106. CONCLUSION: From a biomechanical perspective, cerclage banding distally to an intraoperative clamshell fracture with an extent of 40% of the anchoring length of the stem demonstrated comparable resistance against hip stem loosening versus a non-fractured femur. It may therefore represent a valid treatment option to restore the full axial stability of a diaphyseal anchoring stem. In addition, it may be considered to keep the medial wall fragment unfixed, thus saving operative time and minimizing associated risks.

3.
J Hand Microsurg ; 15(1): 13-17, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36761056

RESUMO

Introduction Music is commonly played in operating rooms. Because microsurgery demands utmost concentration and precise motor control, we conducted the present study to investigate a potentially beneficial impact of music on performing a microsurgical anastomosis. Materials and Methods We included a novice group (15 inexperienced medical students) and a professional group (15 experienced microsurgeons) in our study. Simple randomization was performed to allocate participants to the music-playing first or music-playing second cohort. Each participant performed two end-to-end anastomoses on a chicken thigh model. Participant demographics, their subjective preference for work environment (music/no music), and time to completion were noted. The performance of the participants was assessed using the Stanford Microsurgery and Resident Training (SMaRT) scale by an independent examiner, and the final anastomoses were evaluated according to the anastomosis lapse index. Results Listening to music had no significant effect on time to completion, SMaRT scale, and anastomosis lapse index scores in both novice and professional cohorts. However, the subjective preference to work while listening to music correlated with high SMaRT scale scores within the professional cohort ( p = 0.044). Conclusion Playing their preferred music in the operating room improves the performance scores of surgeons, but only if they subjectively appreciate working with background music.

4.
Eur J Trauma Emerg Surg ; 49(3): 1449-1458, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36508022

RESUMO

PURPOSE: To compare construct stability of cement augmented sacroiliac screws using two different cementation sites in a biomechanical fragility fracture model of the pelvis. METHODS: A fracture model with an incomplete fracture of the sacral ala and complete fracture of the anterior pelvic ring mimicking a FFP IIB fragility fracture of the pelvis was established in five fresh frozen human cadaveric pelvises. Sacral fracture stabilization was achieved with bilateral 7.3 mm fully threaded sacroiliac screws. Cement augmentation was performed at the tip of the screw (body of S1; Group A) on one side, and at the midshaft of the screw (sacral ala; Group B) on the contralateral side. Biomechanical testing was conducted separately on both sides comprising cyclic loading of axial forces transferred through the tested hemipelvis from L5 to the ipsilateral acetabulum. Combined angular displacement in flexion and internal rotation ("gap angle"), angular displacement of the ilium in relation to the screw ("screw tilt ilium"), and screw tip cutout were evaluated. RESULTS: Relative interfragmentary movements were associated with significantly higher values in group A versus group B for "gap angle" (2.4° vs. 1.4°; p < 0.001), and for "screw tilt ilium" (3.3° vs. 1.4°; p < 0.001), respectively. No significant difference was indicated for screw tip cutout between the two groups (0.6 mm [Group A] vs. 0.8 mm [Group B]; p = 0.376). CONCLUSION: The present study demonstrated less fragment and screw displacements in a FFP IIB fracture model under physiologic cyclic loading by cement augmentation of sacroiliac screws at the level of the lateral mass compared to the center of vertebral body of S1.


Assuntos
Parafusos Ósseos , Fraturas Ósseas , Humanos , Fenômenos Biomecânicos , Cimentos Ósseos , Fraturas Ósseas/cirurgia , Pelve , Fixação Interna de Fraturas , Sacro/cirurgia , Sacro/lesões
5.
J Orthop Res ; 41(3): 641-648, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35735256

RESUMO

To biomechanically evaluate the stability of a diaphyseal anchored, cementless stem in presence of a proximal periprosthetic femoral medial wall defect compared to the stability of the same stem in an intact femur. Twenty-two paired human cadaveric femora were pairwise assigned either to a fracture group, featuring a proximal medial wall defect involving 40% of the stems medial anchorage distance, or a control group with native specimens. The specimens were tested under a monotonically increasing cyclic axial loading protocol. Load, cycles, and multiples of the respective body weight at implant loosening was measured. Mean initial stiffness was 2243.9 ± 467.9 N/mm for the intact group and 2190.1 ± 474.8 N/mm for the fracture group. Mean load to loosening in the intact group was 3210.5 ± 1073.2 N and 2543.6 ± 576.4 N in the fracture group, with statistical significance. Mean cycles to loosening in the intact group were 27104.9 ± 10731.7 and 20431.5 ± 5763.7 in the fracture group, with statistical significance. Mean multiples of the resulting body weight at loosening in the intact group was 548.3 ± 158.5% and 441.4 ± 104% in the fracture group, with statistical significance. A medial wall defect involving 40% of the medial anchorage distance significantly decreases the axial stability of a diaphyseal anchored stem. However, mechanical failure occurred beyond physiological stress. At loosening rates of about 4 multiples of the body weight in the fracture group, a "safe zone" remains of a 0.5-fold body weight for maximum loads and twofold body weights for average loads.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Artroplastia de Quadril/métodos , Desenho de Prótese , Fêmur/cirurgia , Reoperação , Fraturas do Fêmur/cirurgia
6.
Eur J Trauma Emerg Surg ; 49(1): 411-418, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35986752

RESUMO

OBJECTIVES: Helical plates are preferably used for proximal humeral shaft fracture fixation and potentially avoid radial nerve irritation. AIMS: Safety of applying four different long plate designs (straight, 45°-, 90°-helical and ALPS) with MIPO technique as well as assessment and comparison of their distances to adjacent anatomical structures. METHODS: MIPO was performed in 16 human cadaveric humeri using either a straight (group 1), a 45°-helical (group 2), a 90°-helical (group 3) plate, or an ALPS (group 4). Applying CT angiography, distances between brachial arteries and plates were evaluated. All specimens were dissected and distances to the axillary, radial and musculocutaneous nerve were evaluated. RESULTS: No specimens demonstrated injuries of the anatomical structures at risk after MIPO with all investigated plate designs. Closest overall distance (mean (range); mm) between each plate and the radial nerve was 1 (1-3) in group 1, 7 (2-11) in group 2, 14 (7-25) in group 3 and 6 (3-8) in group 4. It was significantly bigger in group 3 and significantly smaller in group 1 compared to all other groups, p < 0.001. Closest overall distance between each plate and the musculocutaneous nerve was 16 (8-28) in group 1, 11 (7-18) in group 2, 3 (2-4) in group 3 and 6 (3-8) in group 4. It was significantly bigger in group 1 and significantly smaller in group 3 compared to all other groups, p < 0.001. CONCLUSIONS: MIPO with 45°- and 90°-helical plates as well as with ALPS is safely feasible and demonstrates significantly bigger distances to the radial nerve compared to straight plates. However, the distances remain small and attention must be paid to the musculocutaneous nerve and the brachial artery when MIPO is applied using ALPS, 45°- and 90°-helical implants.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Humanos , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fixação Interna de Fraturas/métodos , Úmero , Placas Ósseas , Fraturas do Ombro/cirurgia , Resultado do Tratamento , Consolidação da Fratura/fisiologia
7.
Medicina (Kaunas) ; 58(11)2022 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-36422175

RESUMO

Background and Objectives: Intramedullary nailing of trochanteric fractures can be challenging and sometimes the clinical situation does not allow perfect implant positioning. The aim of this study was (1) to compare in human cadaveric femoral heads the biomechanical competence of two recently launched cephalic implants inserted in either an ideal (centre-centre) or less-ideal anterior off-centre position, and (2) to investigate the effect of bone cement augmentation on their fixation strength in the less-ideal position. Materials and Methods: Fourty-two paired human cadaveric femoral heads were assigned for pairwise implantation using either a TFNA helical blade or a TFNA screw as head element, implanted in either centre-centre or 7 mm anterior off-centre position. Next, seven paired specimens implanted in the off-centre position were augmented with bone cement. As a result, six study groups were created as follows: group 1 with a centre-centre positioned helical blade, paired with group 2 featuring a centre-centre screw, group 3 with an off-centre positioned helical blade, paired with group 4 featuring an off-centre screw, and group 5 with an off-centre positioned augmented helical blade, paired with group 6 featuring an off-centre augmented screw. All specimens were tested until failure under progressively increasing cyclic loading. Results: Stiffness was not significantly different among the study groups (p = 0.388). Varus deformation was significantly higher in group 4 versus group 6 (p = 0.026). Femoral head rotation was significantly higher in group 4 versus group 3 (p = 0.034), significantly lower in group 2 versus group 4 (p = 0.005), and significantly higher in group 4 versus group 6 (p = 0.007). Cycles to clinically relevant failure were 14,919 ± 4763 in group 1, 10,824 ± 5396 in group 2, 10,900 ± 3285 in group 3, 1382 ± 2701 in group 4, 25,811 ± 19,107 in group 5 and 17,817 ± 11,924 in group 6. Significantly higher number of cycles to failure were indicated for group 1 versus group 2 (p = 0.021), group 3 versus group 4 (p = 0.007), and in group 6 versus group 4 (p = 0.010). Conclusions: From a biomechanical perspective, proper centre-centre implant positioning in the femoral head is of utmost importance. In cases when this is not achievable in a clinical setting, a helical blade is more forgiving in the less ideal (anterior) malposition when compared to a screw, the latter revealing unacceptable low resistance to femoral head rotation and early failure. Cement augmentation of both off-centre implanted helical blade and screw head elements increases their resistance against failure; however, this effect might be redundant for helical blades and is highly unpredictable for screws.


Assuntos
Cimentos Ósseos , Fraturas do Quadril , Humanos , Pinos Ortopédicos , Parafusos Ósseos , Fraturas do Quadril/cirurgia , Cadáver
8.
Medicina (Kaunas) ; 58(6)2022 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-35744036

RESUMO

Background and Objectives: Freehand distal interlocking of intramedullary nails is technically demanding and prone to handling issues. It requires precise placement of a screw through the nail under fluoroscopy guidance and can result in a time consuming and radiation expensive procedure. Dedicated training could help overcome these problems. The aim of this study was to assess construct and face validity of new Digitally Enhanced Hands-On Surgical Training (DEHST) concept and device for training of distal interlocking of intramedullary nails. Materials and Methods: Twenty-nine novices and twenty-four expert surgeons performed interlocking on a DEHST device. Construct validity was evaluated by comparing captured performance metrics-number of X-rays, nail hole roundness, drill tip position and drill hole accuracy-between experts and novices. Face validity was evaluated with a questionnaire concerning training potential and quality of simulated reality using a 7-point Likert scale. Results: Face validity: mean realism of the training device was rated 6.3 (range 4-7). Training potential and need for distal interlocking training were both rated with a mean of 6.5 (range 5-7), with no significant differences between experts and novices, p ≥ 0.234. All participants (100%) stated that the device is useful for procedural training of distal nail interlocking, 96% wanted to have it at their institution and 98% would recommend it to colleagues. Construct validity: total number of X-rays was significantly higher for novices (20.9 ± 6.4 versus 15.5 ± 5.3, p = 0.003). Success rate (ratio of hit and miss attempts) was significantly higher for experts (novices hit: n = 15; 55.6%; experts hit: n = 19; 83%, p = 0.040). Conclusion: The evaluated training device for distal interlocking of intramedullary nails yielded high scores in terms of training capability and realism. Furthermore, construct validity was proven by reliably discriminating between experts and novices. Participants indicate high further training potential as the device may be easily adapted to other surgical tasks.


Assuntos
Pinos Ortopédicos , Fixação Intramedular de Fraturas , Parafusos Ósseos , Fluoroscopia , Fixação Intramedular de Fraturas/métodos , Humanos , Radiografia
9.
Injury ; 53(7): 2636-2641, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35346508

RESUMO

PURPOSE: Helical plates potentially avoid the medial neurovascular structures of the thigh. Two implant designs for additional medial 90° helical plate in double plate constructs for geriatric patients and 180° helical plate for single plating in young patients are potential alternatives to widely used standard straight plates. AIMS: (1) assess the distances to adjacent anatomical structures being at risk when applying medial 90° and 180° helical plates with MIPO technique to the femur, (2) compare these distances with medial straight plates, and (3) correlate measurements performed during surgical dissection with CT angiography. METHODS: MIPO was performed in ten human cadaveric femoral pairs using either a 90° helical 14-hole LCP (Group 1) or a 180° helical 15-hole LCP-DF (Group 2). Using CT angiography, distances between femoral arteries and plates as well as distances between plates and perforating vessels were evaluated. Following, specimens were dissected and distances determined again. All plates were removed and measurements were repeated with straight medial plates (Group 3). RESULTS: Overall closest distances between plates and femoral arteries were 14.5 mm (11-19 mm) in Group 1, 21.6 mm (15-24 mm) in Group 2 and 6.5 mm (5-8 mm) in Group 3, with significant differences between Group 3 and both other groups (p < 0.001). Distances to the nearest perforating vessels were 22.4 mm (15-30 mm) in Group 1 and 1.2 mm (1-2 mm) in Group 2. Measurement techniques (visual after surgical disection and CT angiography) demonstrated a strong correlation (p < 0.010). CONCLUSIONS: Inserting 90° and 180° helical plates with MIPO technique is safe, however, attention must be paid to the medial neurovascular structures with 90° helical plates and to the proximal perforating vessels with 180° helical plates. Helical plates can avoid irritation of medial neurovascular structures - compared with straight plates - although care must be taken during their distal insertion. Measurements during surgical dissection correlate with CT angiography.


Assuntos
Artéria Femoral , Fraturas do Fêmur , Idoso , Placas Ósseas , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fêmur/irrigação sanguínea , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Humanos