Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Arch ; 70(3): 203-7, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27594747

RESUMO

INTRODUCTION: Glaucoma is the most common optic neuropathy which is characterized by progressive loss of retinal ganglion cells, the excavation of the optic nerve head, associated with defects in the visual field. It is not a disease, but the final result of united and yet completely unidentified cellular and subcellular processes and effects of many factors responsible for changes in retinal ganglion cells leading to their accelerated apoptosis. METHODS: This is a prospective-retrospective, comparative, randomized clinical trial that included 150 patients, 97 were female and 53 male. The age of patients ranged from 18 to 80 years. RESULTS: The highest degree of myopia in category of tilted optic discs had patients with large disc (4.05 + -0.65). Values of the degree of myopia have linearly declined in relation to the size of the oblique disc. The analysis of the results revealed that the subjects who had a higher degree of myopia associated with glaucoma had frequent parapapillar atrophy of alpha and beta zones. The highest percentage of subjects with parapapillar changes were in the group of patients who had other than glaucoma and myopia (62%), then in the group of patients with glaucoma only (56%). CONCLUSION: Previous studies on the relationship between myopia and open-angle glaucoma are based on the results of observational studies. However, according to recent findings, based on the available studies, the systematic approach to estimate the association between myopia and glaucoma does not exist. Disc Damage Likelihood Scale (DDLS) is a new system for assessing glaucomatous damage of the optic disc which strongly correlates with the degree of visual field loss.


Assuntos
Glaucoma/diagnóstico , Miopia/diagnóstico , Disco Óptico/diagnóstico por imagem , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica , Adulto , Idoso , Diagnóstico Precoce , Feminino , Glaucoma/complicações , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/complicações , Estudos Observacionais como Assunto , Disco Óptico/patologia , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Campos Visuais , Adulto Jovem
2.
Med Arch ; 69(5): 334-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26622089

RESUMO

AIM: To determine the possible relation between intraocular pressure (IOP), central corneal thickness (CCT) and corneal resistance (CR) in kerotoconic eyes before, 3,6 and 12 months after collagen crosslinking procedure (CXL) with aim to find out does the thicker cornea means already more resistance cornea followed with higher IOP. METHODS: Thirty eyes (30 patients) with central keratoconus (KC)were evaluated in retrospective cross sectional study. The corneal biomechanical parameters were taken with Wave Light Allegro Oculyzer produced by Alcon before the CXL, 3, 6 and 12 months after the procedure. IOP were checked by Goldmann applanation tonometry (GAT) before, 3, 6 and 12 months after CXL. RESULTS: The value of IOP before the CXL was 12,0 mmHg (10,62-15,25 mmHg), 3 months later 13,5 mmHg (11,0-16,0 mmHg), 6 months 14,0 mmHg (11,0-16,0 mmHg) and 12 months later 15,0 mmHg (10,37-17,25 mmHg) and was statistically significant higher (p=0,015) comparing to the value of IOP 3 months after the CXL, IOP 12 months after CXL procedure was statistically significant higher comparing to preoperative values (p=0,010). There were no statistically significant difference between the values 3 and 6 months after CXL. The CCT before the CXL procedure was 449 (433-505,75 microns), 3 months after CXL was 420 (383-473microns, p < 0,005), 6 months later 437 (401,25-480,25, p=0,001), 12 months after CXL 437 (401-503 microns, p=0,001). However there is statistically significant difference in CCT 12 months after CXL 437 (401-503microns p=0,032) and the value of CCT 3 months later the procedure (p=0,004) and the CCT 12 months after CXL and the value of CXL 6 months after CXL (p=0,036). The value of CCT did not show any statistically significant difference 3 and 6 months postoperatively. CONCLUSION: After riboflavin-UVA CXL in eyes with KC there was significant decrease in central corneal thickness 3 and 6 months after the procedure and the thickness is almost the same 12 months later. However IOP is low before CXL, raising up 3 and 6 months after CXL but significant increase is seen 12 months later. It means the regular measurement of IOP could be the serious and confident indicator of increasing of corneal resistance which is the main goal of CXL treatment.


Assuntos
Córnea/patologia , Reagentes de Ligações Cruzadas/uso terapêutico , Ceratocone/terapia , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina/uso terapêutico , Terapia Ultravioleta/métodos , Adulto , Feminino , Humanos , Pressão Intraocular , Ceratocone/patologia , Ceratocone/fisiopatologia , Masculino , Estudos Retrospectivos , Tonometria Ocular , Adulto Jovem
3.
Acta Inform Med ; 22(4): 237-40, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25395724

RESUMO

GOAL: the purpose of the current study was to estimate the predictive values of optical coherence tomography parameters in early, developed perimetric and terminal glaucoma. METHODS: 180 eyes of 120 consecutive patients were evaluated in this retrospective cross sectional pilot study. Copernicus Spectral -domain optical coherence tomography with resolution of 3 mm obtained throught the optic nerve head were included. All examined eyes were divided to four groups (healthy,early, developed perimetric glaucoma and terminal glaucoma). The values of the thicknes of the retinal nerve fibre layer, the size of the disk, the volume of the cup, the E/D parameter and the size of the RIM were compared in four study groups. RESULTS: The sensitivity of RNFL was 90,0%, specificity 82,0 %, positive predictability 83,3 % and negative predictability was 89,1 %. The total accuracy was 86,0 % and area under curve (AUC) was 0,878 for RNFL indeks compering early to developed glaucoma. The sensitivity for CUP was 78%, the specificity was 80,8 %, the positive predictability 81,2% and the negative predictability was 77,5 %. The total accuracy was 79,3 % and area under curve (AUC) was 0,86 compering early to developed glaucoma. The sensitivity for E/D was 82,0%, the specificity was 82,9 % the positive predictability 83,7 % and the negative predictability was 81,3 %. The total accuracy was 82,5 % and area under curve (AUC) for E/D was 0,89 compering eearly to developed glaucoma. The sensitivity for RIM was 78,0%, the specificity was 76,6 %, the positive predictability was 84,7 and the negative predictability was 67,7 %. The total accuracy was 77,5 % and area under curve (AUC) for the RIM compering the developed to terminal glaucoma was 0,792. The sensitivity of RNFL was 88,0 %, the specificity was 66,7 %, the positive predictability was 81,5% and the negative predictability was 76,9%. The total accuracy was 80,0% and the area under curve (AUC) for RNFL compering developed to terminal glaucoma was 0,815. The incrreasing 0,1 unit RNFL decreases the risk of developing glaucoma from early to another developed stage of glaucoma for 6,95%. The increasing of E/D for only one unit increases the risk to develop another stage of glaucoma for 18,75 times. The increasing of RNFL for only one unit decreases the risk of performing developed glaucoma from initial stage for 7,8%. The increasing for only one unit of CUP increases the risk to develop terminal glaucoma for 8,47 times and increasing for 0,1 unit of the value of RIM decreases the risk developing terminal glaucoma for 9,27%. The increasing for 0,01 unit of the E/D index increases the risk for terminal glaucoma for 23,23 times. The increasing for one unit of RNFL decreasing the risk developing terminal glaucoma for 5,7%.

4.
Med Arh ; 68(3): 204-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25195354

RESUMO

INTRODUCTION: Age-related macular degeneration (AMD) is a leading cause of irreversible serious vision damage in persons over 50 years of age. In treating AMD many medicaments are applied such as inhibitors of vascular endothelial growth factor (VEGF), have been very carefully included over the last few years after a series of study research. AIMS: To analyze the past methods of treatment, discuss emerging therapies which could advance the treatment of exudative AMD. The past anti-VEGF therapies require frequent repetitions of administration, with uncertain visual acuity recovery, as not all patients react to anti-VEGF therapy. Consequently, there is a need to find out additional therapies which could improve the treatment of exudative AMD. The real aim in the treating of AMD is to prevent CNV development. METHODS: A survey of the current clinical research and results in the field of the present and future treatments of exudative AMD. RESULTS: There are many areas of research into new methods of the exudative AMD treatment. CONCLUSION: The future therapies for exudative AMD treatment have a potential not only to reduce the frequency of administration and follow-up visits, but also to improve effects of treatment by targeting additional ways of CNV development, increasing the aptitude of target binding and extending durability of treatment.


Assuntos
Degeneração Macular/terapia , Inibidores da Angiogênese/uso terapêutico , Anticorpos Monoclonais Humanizados/uso terapêutico , Aptâmeros de Nucleotídeos/uso terapêutico , Bevacizumab , Terapia Combinada , Humanos , Lentes Intraoculares , Radiação Ionizante , Ranibizumab , Receptores de Fatores de Crescimento do Endotélio Vascular/uso terapêutico , Proteínas Recombinantes de Fusão/uso terapêutico , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores
5.
Med Arch ; 68(2): 113-6, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24937935

RESUMO

GOAL: The aim of the study was to estimate the diagnostic accuracy of optical coherence tomography parameters in normal, preperimetric, developed perimetric and terminal glaucoma. METHODS: 180 eyes of 140 consecutive patients were evaluated in this retrospective cross sectional pilot study. Copernicus Spectra--domain optical coherence tomography with resolution of 3 mm obtained through the optic nerve head were included. All examined eyes were divided into four groups (healthy eyes, initial, preperimetric glaucoma, developed perimetric glaucoma and terminal glaucoma). RESULTS: The highest value of the RIM is noticed in control group 1.44 (1.21-1.70). There is no significant difference in the size of the disc in the eyes with developed open angle glaucoma (1.80 +/- 0.66) compared to normal eyes (p = 0.663), to the eyes with initial glaucoma (p = 0.120), and terminal glaucomatous atrophy (p = 0.068). There is statistically importance of E/D parameter in healthy group 0.17 (0.04-0.27), early glaucomatous group 0.44 (0.35-0.51), developed glaucoma 0.47 (0.39-0.61) respectively p < 0.005. The volume of cup was significantly greater in the eyes with terminal glaucomatous atrophy 1.05 (0.85-1.4) compared to the healthy eyes 0.31 (0.06-0.51) (p < 0.005), significantly greater to initial glaucoma 0.84 (0.58-1.12) (p = 0.007) and significantly higher compared to developed glaucoma 0.82 (0.62-1.07) (p = 0.003). There is no significant difference in the cup between the eyes with early and developed glaucoma (p = 0.912). The eyes with terminal glaucoma had significant lower value of the thickness of retinal nerve fiber layer 56.50 (45.50-71.25) compared to developed glaucoma group 82.5 (72-95.75), initial glaucoma 110.50 (102-123) and healthy eyes 132 (119-150) (p < 0.005). CONCLUSION: The SD-OCT scanning should be used to quantify optic nerve head anatomy in human eyes. The changes can be recognized and can indicate as important risk factor in considering glaucoma changes. It also should be considered as an exact model of glaucoma pathology.


Assuntos
Glaucoma/patologia , Fibras Nervosas/patologia , Disco Óptico/patologia , Estudos Transversais , Feminino , Humanos , Masculino , Projetos Piloto , Estudos Retrospectivos , Tomografia de Coerência Óptica
6.
Med Arch ; 68(3): 204-208, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25568535

RESUMO

INTRODUCTION: Age-related macular degeneration (AMD) is a leading cause of irreversible serious vision damage in persons over 50 years of age. In treating AMD many medicaments are applied such as inhibitors of vascular endothelial growth factor (VEGF), have been very carefully included over the last few years after a series of study research. AIMS: To analyze the past methods of treatment, discuss emerging therapies which could advance the treatment of exudative AMD. The past anti-VEGF therapies require frequent repetitions of administration, with uncertain visual acuity recovery, as not all patients react to anti-VEGF therapy. Consequently, there is a need to find out additional therapies which could improve the treatment of exudative AMD. The real aim in the treating of AMD is to prevent CNV development. METHODS: A survey of the current clinical research and results in the field of the present and future treatments of exudative AMD. RESULTS: There are many areas of research into new methods of the exudative AMD treatment. CONCLUSION: The future therapies for exudative AMD treatment have a potential not only to reduce the frequency of administration and follow-up visits, but also to improve effects of treatment by targeting additional ways of CNV development, increasing the aptitude of target binding and extending durability of treatment.

7.
Med Arch ; 67(5): 372-3, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24601176

RESUMO

GOAL: To estimate corneal cross-linking (CXL) in keratoconus not only as a treatment to heal and increase the corneal stability then to consider it as a refractive procedure. METHODS: 28 eyes of 22 patients with progressive keratokonus were enrolled in prospective comparative study. Average follow up was 9 +/- 2 months (range 5 to 12 months). RESULTS: 6 months later uncorrected visual acuity (UCVA) was 0,2 (range 0,1 -0,5) and was significant higher to UCVA one month after the operation but not different to the results of UCVA before the CXL and three months later. The visual acuity with spectacles or hard contact lenses (BCVA) 6 months after CXL was 0,8 (range 0,57 -1,0) and was extremely higher then before the intervention (p=0,003), one month after CXL (p= 0,001) and significantly higher three months later (p=0,011). CONCLUSION: the CXL shows evident reduction in spherical equivalent refraction, cylinder and max K.


Assuntos
Ceratocone/radioterapia , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina/uso terapêutico , Terapia Ultravioleta/métodos , Humanos , Estudos Prospectivos , Refração Ocular , Resultado do Tratamento , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...