Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Indian J Urol ; 39(4): 303-310, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38077208

RESUMO

Introduction: Stereotactic body radiotherapy (SBRT) has been found to be an effective and safe modality with excellent oncological outcome in medically inoperable primary renal cell carcinoma (RCC) and oligometastases. There is scarcity of data on the synchronous delivery of SBRT to primary and oligometastatic RCC in patients unfit for nephrectomy. Here, we report the findings of a retrospective study of prospectively collected data on "total ablative SBRT." Methods: Oligometastatic RCC patients with intact primary tumors were enrolled between May 2021 and June 2022. SBRT was synchronously delivered to the primary tumor and metastases. Demographics, treatment, oncologic outcomes, and toxicity were assessed. Kaplan-Meier estimates were generated for oncologic outcomes. The primary endpoint of this study was feasibility and tolerability. Results: Eleven patients were enrolled between May 2021 and June 2022. One patient died at 2 months after SBRT due to viral pneumonitis (possibly COVID pneumonia). Nine patients (82%) had metastatic disease, while 2 (18%) were stage II. The average maximal diameter of primary was 68.7 mm (range, 23-128 mm). The SBRT doses for primary and metastasis ranged from 40 to 55 Gray (Gy) in 5 to 7 fractions and 22 to 40Gy in 2 to 5 fractions, respectively. The median follow-up period was 10.5 months (Range: 4-15 months). Response assessment was available for ten patients. Local control, marginal control, regional control and initial oligometastatic control (OMC) rates were 100%. OMC declined to 87.5% as one patient had recurrence in irradiated subcarinal lymphnode at 7 months. The metastatic control rate was 80% and loco-regional progression-free survival was 8 months (range, 4-15 months). Toxicities were minimal and manageable. At the last follow-up, 7 of 11 patients were alive with an overall survival of 63.5%. Six patients received systemic therapy after SBRT. Conclusions: Synchronous delivery of SBRT to primary and oligometastatic sites in patients unfit for nephrectomy was feasible and tolerable with good locoregional control. The total ablative SBRT strategy needs to be explored in similar cohorts.

3.
Asian Pac J Cancer Prev ; 24(4): 1239-1248, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37116146

RESUMO

OBJECTIVE: The aim of this study is to makethe standard total body irradiation (TBI) protocol for Helical tomotherapy© (HT) and to analyze the optimal pitch and modulation factor (MF) with respect to dose homogeneity index (HI), target dose coverage, target overdose, beam on time (BOT) and mean lung dose. MATERIALS AND METHODS: Ten patients who underwent high-dose TBI were taken for this study. For each patient, 35 dose plans were created by different combination of pitch and MF. The optimal pitch and MF were deduced using scatter plot and regression methodology based on target coverage, HI, target volume receiving 103%(V103%), 105%(V105%) and 107% (V107%) of the prescription dose and BOT. Using these optimal pitch and MF, the final dose plan was made and the planning aim and achieved dose was compared using two tailed student's t-test. Radiochromic films and ionization chambers were used to measure the delivered dose using anthropomorphic phantom on various points for the head and pelvis regions to verify the skin flash margin and its effect on skin dose. RESULTS: The optimal pitch and MF value were 0.287 and 2.4 respectively. Based on optimal pitch and MF, the mean BOT was 1692 seconds with optimal inhomogeneity (7.4%). For target, D95 and D98 were 97.09% (range:94.7-99.6%, p=0.002) and 93.9% (range:91.5-94.4%,p=0.007) respectively, and mean D2 was within 107% with SD of ±1.22% (p=0.04). The mean of PTV receiving V103, V105 and V107 was 24.48% (range=7.7-36.6%, p=0.03), 5.76% (range=1.4-12.1%, SD=±3.3%), 1.93% (range=0.1-4.6%, p=0.008) respectively. Our measurements show that the flash margin did not increase the skin dose. CONCLUSION: In our study, the optimal combination of pitch value of 0.287 and MF value of 2.4 provided acceptable plans for all patients planned for TBI in HT. The flash margin can provide adequate coverage during patient position uncertainty without increasing the skin dose.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Irradiação Corporal Total , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radiometria/métodos
4.
Pract Radiat Oncol ; 13(2): e134-e138, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35977668

RESUMO

Incremental use of high-dose radiation therapy (RT) with SABR in thoracic tumors has led to identification of many unusual toxicities (chest wall pain, rib fractures, vascular perforation, brachial plexopathy) and consequently additional organs at risk (OARs; chest wall, ribs, bronchial wall, carotid artery, brachial plexus). Phrenic nerve is another structure that may be affected at any point during its long course from origin until end, although symptomatic toxicities have been reported rarely in the setting of reirradiation, large-volume irradiation such as mantle field, or SABR. We undertook a prospective study to describe the delineation of phrenic nerve course on RT planning computed tomography scan as an OAR. An anonymized RT planning computed tomography scan of neck and thorax (1.5-mm slice thickness, intravenous contrast) was used for the study. Radiology textbooks and publications were reviewed, and the course was delineated with the help of 2 radiologists and 6 radiation oncologists well versed with thoracic radiologic anatomy. A step-by-step description in the form of a pictorial essay is given. The adjacent structures including cervical vertebrae, cervical and mediastinal vessels, lungs, heart, and so on were identified, and the course of phrenic nerve on either side is described in relation to these structures. Delineation of the phrenic nerve as an OAR is challenging but feasible. We recommend routine delineation of the phrenic nerve as an OAR during thoracic RT. Although specific dose constraints are not known yet, unnecessary dose to the same during RT planning should be minimized.


Assuntos
Neoplasias Pulmonares , Nervo Frênico , Humanos , Nervo Frênico/patologia , Estudos Prospectivos , Neoplasias Pulmonares/radioterapia , Pulmão/patologia , Tórax
5.
J Contemp Brachytherapy ; 15(6): 391-398, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38230402

RESUMO

Purpose: This survey aimed to understand the practice pattern and attitude of Indian doctors towards prostate brachytherapy. Material and methods: A 21-point questionnaire was designed in Google form and sent to radiation oncologists practicing in India, using texts, mails, and social media. Responses were collated, and descriptive statistical analysis was performed. Results: A total of 212 radiation oncologists from 136 centers responded to the survey questionnaire, with majority (66%) being post-specialty training > 6 years. We found that about 44.3% (n = 94) of respondents do not practice interstitial brachytherapy for any site, and majority (83.3%, n = 175) do not practice high-dose-rate (HDR) prostate brachytherapy. Only 2.8% (n = 6) of doctors preferred boost by brachytherapy compared with 38.1% (n = 80) of respondents, who favored stereotactic body radiation therapy (SBRT) boost. When asked about the indication of HDR prostate brachytherapy in Indian setting, 32.5% (n = 67) of respondents favored monotherapy, 46.1% (n = 95) of oncologists thought boost as a good indication, and 21.4% (n = 44) preferred re-irradiation/salvage setting. The most cited reason for prostate brachytherapy not being popularly practiced in India was lack of training (84.8%, n = 179). It was also noted that out of 80 respondents who practiced SBRT for prostate boost, 37 would prefer HDR brachytherapy boost if given adequate training and facilities. Conclusions: The present survey provided insight on practice of prostate brachytherapy in India. It is evident that majority of radiation oncologists do not practice HDR prostate brachytherapy due to lack of training and infrastructure. Indian physicians are willing to learn and start prostate brachytherapy procedures if dedicated training and workshops are organized.

6.
Cancers (Basel) ; 14(19)2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-36230831

RESUMO

Survival, recurrence, and xerostomia are considerable problems in the treatment of oral squamous carcinoma patients. In this study, we investigated the role of DMA (5-(4-methylpiperazin-1-yl)-2-[2'-(3,4-dimethoxyphenyl)5″benzimidazoyl]benzimidazole) as a salivary gland cytoprotectant in a patient-derived xenograft mouse model. A significant increase in saliva secretion was observed in the DMA-treated xenograft compared to radiation alone. Repeated doses of DMA with a high dose of radiation showed a synergistic effect on mice survival and reduced tumor growth. The mean survival rate of tumor-bearing mice was significantly enhanced. The increased number of Ki-67-stained cells in the spleen, intestine, and lungs compared to the tumor suggests DMA ablates the tumor but protects other organs. The expression of aquaporin-5 was restored in tumor-bearing mice injected with DMA before irradiation. The reduced expression of αvß3 integrin and CD44 in DMA alone and DMA with radiation-treated mice suggests a reduced migration of cells and stemness of cancer cells. DMA along with radiation treatment results in the activation of the Ras/Raf/MEK/ERK pathway in the tumor, leading to apoptosis through caspase upregulation. In conclusion, DMA has strong potential for use as an adjuvant in radiotherapy in OSCC patients.

10.
J Radiosurg SBRT ; 8(4): 257-264, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37416331

RESUMO

Objectives: Stereotactic body radiotherapy (SBRT) can sterilize the portal vein tumour thrombus (PVTT) and may make the patient eligible for liver transplant. We assessed the radiological response of PVTT after SBRT and check incidence of radiation induced liver disease (RILD). Methods: PVTT treatment response was measured at 4-6 weeks as per mRECIST criteria, volume of PVTT and its enhancement in arterial phase. Biochemical data and Child-Pugh scoring (CPC) were evaluated to determine RILD incidence. Results: 31 Patients were included. Complete response was seen in 5 patients (16.1%), partial response in 13 patients (41.9%), stable disease in 12 patients (38.7%). Mean volume of PVTT was 15.05 cc before SBRT and 7.83 cc afterwards (p = 0.001). The mean enhancement of the lesion was 86.19HU before SBRT vs 58.58HU after SBRT (p = 0.000). Two patients had grade 3 adverse events. Conclusion: Volume, enhancement, and major axis length of PVTT showed statistically significant improvement after SBRT. No case had RILD after SBRT.

11.
J Radiosurg SBRT ; 8(3): 201-209, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36861001

RESUMO

Purpose/Objectives: Accurate delineation of target is key to any successful radiosurgery. C-arm Dyna CT/ 3DCT angiography (3DCTA) has the potential of improving the accuracy of nidus delineation in intracranial arteriovenous malformations (AVM) due to high temporo-spatial resolution of vessel architecture. Here, we present a comparison of nidus delineation and dosimetric parameters between digital 3DCTA and MRI. Materials/Methods: Ten consecutive patients treated for intracranial AVMs were included in this study. All patients underwent MRI/MRA, and 3DCTA and all images were co-registered. AVM were delineated using 3DCTA (GTV3DCTA) and contrast enhanced MRI/MRA (GTVMRI). Hausdorff distance (HD) matrices and dice similarity coefficient (DSC) matrices were analysed. Stereotactic radiosurgery plans were developed for both the volumes for all patients and statistical analysis were performed with T-test. Results: Mean volumes of GTV3DCTA and GTVMRI were 1.771 cc (SD 1.794cc, range 0.124-4.191cc) and 2.183cc (SD 2.16cc, range 0.221-6.133cc), respectively. Significant deviation (p=0.018) was found when taking GTVMRI as a primary and comparing it to GTV3DCTA (MD=0.723cc±0.816cc). Similar result was observed with GTV3DCTA as primary and GTVMRI as secondary (MD=0.188cc, SD=0.193cc, p=0.024). Maximum HD was in the range of 1.71 to 7.44mm (mean=4.27mm, SD=1.56). For GTV3DCTA based plans, significant deviation was found between GTVMRI and GTV3DCTA in dose coverage and the mean difference was 22.17% (SD 16.73). In GTVMRI based plans, the mean CIRTOG deteriorated from 1.33 to 2.18 for GTVMRI and GTV3DCTA, respectively. Significant deviation was found in CIRTOG (0.005) and mean deviation was 0.86(SD=0.72) when comparing GTVMRI and GTV3DCTA. Highly significant (p=0.002) deviation was found in CIPaddick between GTVMRI and GTV3DCTA for GTVMRI based plans with mean difference of 0.26(SD=0.4, for GTVMRI=0.3, GTV3DCTA=0.46). Conclusion: Nidus volume was significantly altered with the use of 3DCTA compared to that of MRA/MRI images. Multimodality imaging is crucial for accurate target delineation, and successful radiosurgical obliteration of nidus.

12.
J Med Phys ; 47(4): 322-330, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36908497

RESUMO

Aim: The goal of this study is to discuss the commissioning and dosimetric parameters achieved during the clinical implementation of an indigenously developed intracavitary (IC) plus interstitial (IS) template for high dose rate (HDR) image-guided brachytherapy (IGBT) in cancer (Ca) cervix. We want to discuss our achieved values of cumulative equi-effective doses (EQD2) for high-risk clinical target volume (HRCTV) and organ at risk (OAR) and compare it with available published results. Materials and Methods: Medanta anterior oblique/lateral oblique template has a total of 19 needles including the central tandem. For commissioning the template with needles, the indigenously made acrylic phantom was used. Oblique and straight needles were placed inside the acrylic phantom and a computed tomography (CT) scan was performed. Sixteen patients were treated in HDR IGBT using this template after external-beam radiotherapy. The IGBT plans were evaluated based on EQD2 of target coverage i.e., dose received by 98% (D98%_HRCTV), 90% (D90%_HRCTV), and 50% (D50%_HRCTV) volume of HRCTV, and dose received by 2 cc (D2cc) and 0.1 cc (D0.1cc) of OAR using linear quadratic (LQ) radiobiological model. Results: The autoradiographic in radiochromic film shows that the distance between the needle tip and the middle of the source position is 6 mm. The mean D98%_HRCTV and D90%_HRCTV was 76.8 Gy (range: 70-87.7 Gy, P < 0.01) and 84.49 Gy (range: 76.6-96.7 Gy, P < 0.01), respectively. Mean EQD2 of D2cc of the bladder, rectum, and sigmoid was 85.6 Gy (range: 77.5-99.6 Gy, P < 0.03), 74.3 Gy (range: 70.9-76.7 Gy, P < 0.05), and 58.3 Gy (range: 50.6-67.9 Gy, P = 0.01), respectively. The mean total reference air kerma at a 1 m distance is 0.489cGy (range: 0.391-0.681cGy). Conclusions: The indigenously developed template could attain satisfactory standards in terms of set parameters for commissioning and acceptable dose volume relations in our clinical use for treating the advanced Ca cervix patients who need IC + IS type of HDR IGBT. The comparative analysis with contemporary applicators was acceptable.

13.
South Asian J Cancer ; 10(2): 107-111, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34568224

RESUMO

Purpose Use of stereotactic ablative radiotherapy (SABR) in the treatment of recurrent or metastatic lesions from a primary gynecologic cancer is a relatively new concept. The present study aims to assess the safety, efficacy, and possible toxicity profile of CyberKnife SABR, recurrent or metastatic disease. Materials/Methods CyberKnife VSI-based SABR was offered to 20 oligometastatic/recurrent gynecological cancer patients between 2013 and 2019. Patient, tumor, and treatment characteristics including radiotherapy details, clinical outcome in terms of local control rates, and toxicities are reported in this study. Results Twenty-five recurrent or oligometastatic lesions for 20 primary gynecologic cancer patients including cervical ( n = 8), ovarian ( n = 6), endometrial ( n = 5), and vulvar ( n = 1) cancers were analyzed. Of these, 4 (16%) were intracranial lesions and remaining 21 (84%) were extracranial, consisting of 14 (67%) extrapelvic and 7 (33%) pelvic lesions. The median SABR dose delivered was 60 Gy biologically effective dose (range 42-133 Gy) in an average of four fractions (range 1-6). The mean follow-up was 18 (range 2-70) months. Local tumor control was achieved in 82% of patients. There was no grade ≥ 3 toxicity recorded. Conclusion Our study results suggest that CyberKnife SABR is an effective treatment modality with no major morbidity in patients with recurrent or oligometastatic gynecological cancers.

14.
J Med Phys ; 46(1): 16-25, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34267485

RESUMO

PURPOSE: To investigate the dosimetric comparison of different collimators which are used in robotic radiosurgery (cyberknife-CK) and linear accelerator (LINAC) for stereotactic radiosurgery (SRS) in arteriovenous malformation (AVM). MATERIALS AND METHODS: Twenty-five AVM patients were planned in CK using FIXED cone, IRIS collimator, and multi-leaf collimator (MLC) based in LINAC. Dosimetric comparison was performed using Paddick conformity index (CIPaddick) and International Commission on Radiation Units and measurements (ICRU) homogeneity index (HIICRU), gradient score (GS), normal brain dose received by 10cc (D10cc) and critical structure (brain stem, optic chiasma, optic nerves) doses. Paired sample t-test was used for statistical analysis. RESULTS: Mean treatment volume was 3.16cc (standard deviation ± 4.91cc). No significant deviation (P =0.45, 0.237 for FIXED vs. IRIS and FIXED vs. MLC, respectively) was found in target coverage. For CIPaddick, the mean difference (MD) between FIXED- and MLC-based plans was 0.16(P = 0.001); For HIICRU, difference between FIXED and IRIS was insignificant (0.5, P = 0.823); but, when FIXED versus MLC, the deviation was 7.99% (P = 0.002). In FIXED- and MLC-based plans, significant difference was found in GS70 and GS40 (P < 0.041 and 0.005, respectively). MD between FIXED- and MLC-based plans for normal brain for 5Gy, 10Gy, 12Gy, and 20Gy were 36.08cc (P = 0.009), 7.12cc (P = 0.000), 5.84cc (P = 0.000) and 1.56cc (P = 0.000), respectively. AVM volume <0.7cc should be treated with CK FIXED and >0.7cc were treated by using FIXED or IRIS collimators. AVM volume > 1.4cc can be treated by either LINAC MLC-based SRS or CK. CONCLUSION: Our study shows CK collimator (IRIS and FIXED) could be able to treat brain AVMs in any size. Linac MLC-based SRS has some limitations in terms of conformity and low-dose spillage, and advantages like reduced treatment time and MU.

15.
Br J Radiol ; 94(1122): 20200842, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33914614

RESUMO

Artificial intelligence (AI) applications, in the form of machine learning and deep learning, are being incorporated into practice in various aspects of medicine, including radiation oncology. Ample evidence from recent publications explores its utility and future use in external beam radiotherapy. However, the discussion on its role in brachytherapy is sparse. This article summarizes available current literature and discusses potential uses of AI in brachytherapy, including future directions. AI has been applied for brachytherapy procedures during almost all steps, starting from decision-making till treatment completion. AI use has led to improvement in efficiency and accuracy by reducing the human errors and saving time in certain aspects. Apart from direct use in brachytherapy, AI also contributes to contemporary advancements in radiology and associated sciences that can affect brachytherapy decisions and treatment. There is a renewal of interest in brachytherapy as a technique in recent years, contributed largely by the understanding that contemporary advances such as intensity modulated radiotherapy and stereotactic external beam radiotherapy cannot match the geometric gains and conformality of brachytherapy, and the integrated efforts of international brachytherapy societies to promote brachytherapy training and awareness. Use of AI technologies may consolidate it further by reducing human effort and time. Prospective validation over larger studies and incorporation of AI technologies for a larger patient population would help improve the efficiency and acceptance of brachytherapy. The enthusiasm favoring AI needs to be balanced against the short duration and quantum of experience with AI in limited patient subsets, need for constant learning and re-learning to train the AI algorithms, and the inevitability of humans having to take responsibility for the correctness and safety of treatments.


Assuntos
Inteligência Artificial , Braquiterapia , Radioterapia (Especialidade)/tendências , Previsões , Humanos , Erros Médicos/prevenção & controle
16.
J Food Sci Technol ; 58(4): 1480-1487, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33746276

RESUMO

The knowledge of the dielectric properties of oils is of great importance for several industrial applications, such as microwave-assisted oil frying for foods and high voltage electric power transmission. In this paper, we present the complex permittivity of vegetable oils (canola, olive, soybean, coconut) at 2.50 GHz using the cavity perturbation technique from 28 to 200 °C (temperature close to the smoking point of oils). The measurements were taken with a cylindrical cavity operating at the TE111 mode with an unloaded Q of 4950. In addition, free fatty acids, peroxide index and color were measured before and after heating.

17.
J Food Sci ; 86(1): 112-119, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33368317

RESUMO

The dielectric properties and specifically the complex relative permittivity of foods are key elements for the design of pasteurization processes with high frequency electromagnetic waves. Mexican sauces are recognized worldwide for their flavor and nutritional properties. In this work, the complex permittivity of four of the most representative sauces of Mexican cuisine (chipotle chili, habanero chili, red and green sauce) is presented. The permittivity was measured with the open coaxial probe method at temperatures of 25, 40, 55, 70, 85 °C and in the frequency range of 500 MHz to 6 GHz. Additionally, moisture content, specific heat, viscosity, water activity, density and electrical conductivity are reported, these last three at 25 °C. Dielectric properties were affected by the sauce formulation. The loss factor of each sauce sample at any temperature presents significant changes in relation to the frequency. At 915 and 2,450 MHz, d ε ' ' d T > 0 , which would cause a thermal runaway effect or the uncontrolled rise in temperature in the sauces during the microwave pasteurization. At 5,800 MHz, d ε ' ' d T < 0 , which would give better control for microwave heating than at 915 and 2,450 MHz. At 915 MHz, the loss factor of all sauces is higher than at 2,450 and 5,800 MHz, therefore, more rapid heating can be produced. Moreover, at 915 MHz, microwaves exhibit higher penetration depth than at 2,450 and 5,800 MHz; therefore, at 915 MHz, the greatest uniform microwave dielectric heating would be achieved. Thus, 915 MHz is the frequency recommended for the studied sauces pasteurization. PRACTICAL APPLICATION: This work provides the dielectric properties of Mexican sauces at different temperatures and their penetration depths in the microwave range, which are key information for further microwave-assisted pasteurization process and for getting safer sauces for consumers. Moreover, this research supplies suggestions about what frequency for ISM (Industrial, Scientific and Medical) applications is the best for microwave-assisted pasteurization according to the penetration depth of the electromagnetic wave in the sauces and microwave dielectric heating speed of the sauces.


Assuntos
Condimentos/análise , Análise de Alimentos/métodos , Calefação , Micro-Ondas , Pasteurização/métodos , Temperatura
18.
J Egypt Natl Canc Inst ; 32(1): 23, 2020 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-32462353

RESUMO

BACKGROUND: Central neurocytomas represent 0.25-0.5% of all intracranial tumors in adults. Leptomeningeal spread is uncommon, and the exact incidence of meningeal spread is unknown due to sparse literature. We present the clinical course and management outcome of a case of atypical central neurocytoma with leptomeningeal spread. CASE PRESENTATION: A young gentleman, who initially presented with memory loss, was found to have a right intra-axial periventricular mass on imaging. He underwent subtotal resection, and operative histopathology suggested a periventricular atypical neurocytoma. In view of subtotal resection, adjuvant focal radiation therapy was recommended, but he developed headache and blurring of vision 10 days postoperatively. Contrast enhanced craniospinal magnetic resonance imaging (MRI) showed residual primary tumor as well as diffuse leptomeningeal spread. Cerebrospinal fluid cytology also showed malignant cells. After tumor board discussion, craniospinal axis irradiation was advised and delivered. He remained disease-free for 10 months after radiation therapy, but then developed local and spinal recurrence, and offered salvage chemotherapy. His general condition deteriorated following chemotherapy with disease progression, and he was subsequently advised best supportive care. CONCLUSION: Leptomeningeal dissemination in atypical neurocytomas portends an aggressive course and adverse prognosis; management decisions may need tailoring as per individual presentation.


Assuntos
Neoplasias Encefálicas/patologia , Neoplasias Meníngeas/etiologia , Neurocitoma/patologia , Adulto , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/terapia , Humanos , Imageamento por Ressonância Magnética , Masculino , Neurocitoma/diagnóstico por imagem , Neurocitoma/terapia
19.
J Contemp Brachytherapy ; 12(1): 44-47, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32190069

RESUMO

PURPOSE: In advanced cervical cancers, improved techniques using both intracavitary and interstitial brachytherapy (IC + IS) should be used to adequately cover the residual tumor volume, resulting in better clinical results. Confronted with some limitation in implementing available applicators, we devised our own indigenous template that would also serve as an applicator. MATERIAL AND METHODS: First, a graphical design was drawn, keeping in mind the extent of volumes that need to be targeted in various brachytherapy scenarios. It was validated in a computer system and a physical template was manufactured. The template underwent modified versions through iterative dosimetric and planning exercises. The final model was successfully implemented in a clinical scenario. RESULTS: Cylindrical templates of diameter 3, 4, and 5 cm were produced with central aperture for central tandem, combining surrounding holes spaced at pre-planned points. The instrument can be used for IC + IS brachytherapy in cervical cancers. This easy to use applicator/template can direct needles to treat a distance of 4.5 cm laterally at the level of point A. In two initial applications 55 and 54 cc of high-risk clinical target volumes (HRCTV) were treated, and 90% of the HRCTV was covered by 96% and 97% of prescribed doses, respectively. Additionally, the needles guided by the template helped in sculpting the dose from bladder and rectum. CONCLUSIONS: We have developed an easy to use IC + IS type of template/applicator, which was successfully implemented in our clinical practice.

20.
Transplantation ; 104(11): 2334-2345, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32032291

RESUMO

BACKGROUND: Median survival in patients with hepatocellular carcinoma (HCC) and portal vein tumor thrombosis (PVTT) is 2-6 months; conventionally liver transplantation is contraindicated. METHODS: We studied outcomes following living donor liver transplantation (LDLT) post-PVTT downstaging (DS) with stereotactic body radiotherapy (SBRT), and tumor ablation (with transarterial chemo- or radio-embolization). RESULTS: Of 2348 consecutive LDLTs, 451 were for HCC, including 25 with PVTT (mainly Vp1-3) after successful DS and 20 with Vp1/2 PVTT without previous treatment. DS was attempted in 43, was successful in 27 (63%), and 25 underwent LDLT. Median alpha fetoprotein (AFP) at diagnosis and pre-LDLT were 78.1 ng/mL (3-58 200) and 55 ng/mL (2-7320), respectively. Mean DS to LDLT time was 10.2 weeks (5-16). Excluding 2 postoperative deaths, 1- and 5-year overall survival (OS) and recurrence-free survival (RFS) were 82%, 57%, and 77%, 51%, respectively, comparable to survival in 382 HCC patients without PVTT undergoing upfront LDLT (5-y OS 65%, P = 0.06; RFS 66%, P = 0.33, respectively). There was a trend toward better OS in DS+LDLT versus non-DS LDLT group (5-y OS/RFS-48%/40%). OS was significantly better than in HCC-PVTT patients receiving no intervention or palliative Sorafenib alone (1-y OS of 0%) or Sorafenib with TARE/SBRT (2-y OS of 17%) at our center during the study period. Initial AFP <400 ng/mL and AFP fall (initial minus pre-LDLT) >2000 ng/mL predicted better RFS; Grade III/IV predicted worse OS in DS patients. CONCLUSIONS: HCC patients with PVTT can achieve acceptable survival with LDLT after successful DS. Low initial AFP level, a significant drop in AFP with DS and low tumor grade, favorably influence survival in these patients.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica , Neoplasias Hepáticas/terapia , Transplante de Fígado , Células Neoplásicas Circulantes/patologia , Veia Porta/patologia , Radiocirurgia , Trombose Venosa/terapia , Adulto , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Quimioembolização Terapêutica/efeitos adversos , Quimioembolização Terapêutica/mortalidade , Bases de Dados Factuais , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Transplante de Fígado/efeitos adversos , Transplante de Fígado/mortalidade , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Veia Porta/diagnóstico por imagem , Radiocirurgia/efeitos adversos , Radiocirurgia/mortalidade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/mortalidade , Trombose Venosa/patologia , alfa-Fetoproteínas/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...