Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 236
Filtrar
2.
Cornea ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38635475

RESUMO

PURPOSE: The purpose of this study was to investigate the changes in higher-order aberrations (HOAs), coma, and spherical aberrations (SAs) on the anterior, posterior, and total corneal surfaces after pterygium excision. METHODS: In this single-center study, we examined 19 eyes of 15 patients who underwent pterygium excision at Yokohama Minami Kyosai Hospital between January 2017 and December 2017. We also evaluated 25 eyes of 25 age-matched patients with no history of ocular disease as the control group. Corneal topography, total HOAs, coma, and SAs in all regions at 4 and 6 mm diameters were evaluated using anterior segment optical coherence tomography (CASIA SS-1000, Tomey, Japan). The pterygium area and extent were also assessed. RESULTS: Significant improvements in the HOAs, coma, and SAs at both diameters were observed in the total and anterior corneas from the first postoperative month. Notably, the posterior cornea showed significant improvements in HOAs (4 mm: P < 0.001 [log HOAs]; 6 mm: P = 0.001 [log HOAs]) and coma (4 mm: P = 0.003 [log coma], 6 mm: P = 0.002 [log coma]) within both diameters at 1 month postoperatively. A strong correlation was identified among the pterygium area, posterior HOAs, and coma (Spearman correlation = 0.651). Pterygium induced 2 D of astigmatism when extension exceeded 2.1 mm. CONCLUSIONS: HOAs in both the anterior and posterior corneas improved after pterygium excision. This finding underscores the importance of considering corneal aberrations on both anterior and posterior surfaces in pterygium management.

3.
Eur J Cardiovasc Nurs ; 23(3): 305-312, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37474312

RESUMO

AIMS: It is more important for patients with heart failure (HF) to objectively identify their self-care status. The Self-Care of Heart Failure Index (SCHFI) version 7.2 is a reliable and valid instrument comprising three scales: self-care maintenance, symptom perception, and self-care management. We aimed to translate the SCHFI v.7.2 into Japanese and test its validity and reliability. METHODS AND RESULTS: This was a cross-sectional study. Two translators performed forward and backward translations between English and Japanese. To assess structural validity, confirmatory factor analyses were performed using the structure of the original version. To assess convergent validity, the associations between each scale and self-care self-efficacy were evaluated. To assess internal consistency, model-based internal consistency coefficients were calculated. Participants were 314 Japanese outpatients with HF (mean age: 72.8 ± 12.8 years). Regarding structural validity, all scales showed adequate model fit indices, supporting a two-factor structure with items similar to those in the original version. However, to improve the model fit indices, it was necessary to add error correlations for the self-care maintenance and symptom perception scales. Regarding convergent validity, all scales showed significant associations with self-care self-efficacy. Regarding internal consistency, the model-based internal consistency coefficients were sufficient for all scales (0.739, 0.908, and 0.783 for the self-care maintenance, symptom perception, and self-care management scales, respectively). CONCLUSION: The Japanese version of the SCHFI v.7.2 had adequate validity and reliability. This instrument is useful for assessing self-care in Japanese HF patients. However, factors influencing self-care should be considered when interpreting results.


Assuntos
Insuficiência Cardíaca , Autocuidado , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Psicometria/métodos , Inquéritos e Questionários , Estudos Transversais , Reprodutibilidade dos Testes , Japão , Insuficiência Cardíaca/terapia , Traduções
4.
ESC Heart Fail ; 11(2): 811-818, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38158757

RESUMO

AIM: This paper describes the trajectory during 1 year of four patient-reported outcomes (PROs), namely, sleep, depressive symptoms, health-related quality of life (HrQoL), and well-being, in patients with heart failure (HF), their relationship and the patient characteristics associated with changes in these PROs. METHODS AND RESULTS: Data analyses of PROs from 603 patients (mean age 67 years; 29% female, 60% NYHA II) enrolled in the HF-Wii study. On short term, between baseline and 3 months, 16% of the patients experienced continuing poor sleep, 11% had sustained depressive symptoms, 13% had consistent poor HrQoL, and 13% consistent poor well-being. Across the entire 1-year period only 21% of the patients had good PRO scores at all timepoints (baseline, 3, 6, and 12 months). All others had at least one low score in any of the PROs at some timepoint during the study. Over the 12 months, 17% had consistently poor sleep, 17% had sustained symptoms of depression, 15% consistently rated a poor HrQoL, and 13% poor well-being. Different patient characteristics per PRO were associated with a poor outcomes across the 12 months. Age, education, New York Heart Association, and length of disease were related to two PRO domains and submaximal exercise capacity (6 min test), co-morbidity, and poor physical activity to one. CONCLUSION: In total, 79% of the patients with HF encountered problems related to sleep, depressive symptoms, HrQoL, and well-being at least once during a 1-year period. This underscores the need for continuous monitoring and follow-up of patients with HF and the need for dynamic adjustments in treatment and care regularly throughout the HF trajectory.


Assuntos
Insuficiência Cardíaca , Qualidade de Vida , Humanos , Feminino , Idoso , Masculino , Depressão , Insuficiência Cardíaca/diagnóstico , Comorbidade , Medidas de Resultados Relatados pelo Paciente
5.
Medicine (Baltimore) ; 102(40): e35216, 2023 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-37800820

RESUMO

To investigate sex differences in the titles and lifestyles of Japanese ophthalmologists, we evaluated work places and private lives. Retrospective cross-sectional study. The study included 1721 members (1344 males and 377 females) of the Japanese Society of Cataract and Refractive Surgery. An online, anonymized questionnaire was distributed to the society members. The questionnaire included 40 questions to collect data on profiles, lifestyles, job title, families, spouses, children, household chores, child-rearing, and work satisfaction. In total, 219 members (144 males and 75 females; 53.4 ±â€…1.0 and 51.3 ±â€…9.9 years old, respectively) completed the questionnaire. The job title, working time, annual income, marriage rate, and the number of children significantly differed between male and female respondents. Female respondents had greater responsibilities toward house chores, child care, and nursing, whereas several male doctors had spouses who did not work or worked for shorter times, earned a lower income, and contributed greater toward family responsibilities. Female respondents changed their job titles after having children more frequently than male respondents. Both males and females had limited time available for community activities and volunteer work. There were no significant differences in daily sleep duration. Both sexes were equally satisfied with their career choice of ophthalmology; however, fewer females recommended ophthalmology as a career for students and children compared to males. There are significant sex differences among ophthalmologists in Japan in terms of family responsibilities; this topic has received insufficient attention.


Assuntos
Catarata , Oftalmologia , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Japão , Caracteres Sexuais , Estudos Transversais , Estudos Retrospectivos , Inquéritos e Questionários , Estilo de Vida , Satisfação no Emprego
6.
J Ultrasound Med ; 42(9): 2107-2114, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37079609

RESUMO

OBJECTIVES: Lumbopelvic pain (LPP) is a very common cause of discomfort during pregnancy, but its etiology remains unclear. The association between abdominal muscle thickness and LPP in pregnant women has not been studied extensively, despite the significant abdominal changes that occur during pregnancy. This study aimed to examine the relationship between abdominal muscle thickness and LPP in pregnant women. METHODS: In this study, 49 pregnant women in their second trimester participated. The intensity of LPP was assessed using a numerical rating scale. Ultrasound imaging was used to measure the thickness of abdominal muscles, including the rectus abdominis, external oblique, internal oblique, and transversus abdominis muscles. Participants were classified into two groups, the LPP group and non-LPP group, and the abdominal muscle thickness was compared between the two groups. The statistical significance level was set at P < .05. RESULTS: There were 24 and 25 participants in the LPP and non-LPP groups, respectively. Internal oblique (IO) thickness was significantly thinner in the LPP group than in the non-LPP group (5.4 ± 0.2 mm versus 6.1 ± 0.2 mm; P = .042). Multivariate logistic regression analysis showed that IO thickness was significantly associated with LPP (odds ratio, 0.516; 95% confidence interval, 0.284-0.935; P = .019). CONCLUSIONS: This study suggested that LPP in second trimester pregnancy might be related to IO thickness. Further longitudinal studies are needed to understand the role of this muscle as an LPP risk factor for pregnant women.


Assuntos
Dor Lombar , Gestantes , Feminino , Humanos , Gravidez , Dor Lombar/diagnóstico por imagem , Músculos Abdominais/diagnóstico por imagem , Músculos Abdominais/fisiologia , Ultrassonografia , Reto do Abdome
7.
Enferm. glob ; 22(70): 234-245, abr. 2023. tab
Artigo em Espanhol | IBECS | ID: ibc-218644

RESUMO

Introducción: Con el fin de alcanzar una vida óptima, los pacientes con dispositivos de asistencia ventricular izquierda implantables de forma permanente se enfrentan a regímenes de tratamiento complejos; requieren adquirir conocimiento y desarrollar habilidades para orientar su cuidado. Esto hace necesario que el profesional de enfermería cuente con herramientas que permitan identificar el nivel de autocuidado como punto de partida para promover comportamientos positivos que permitan adherirse a su nuevo estilo de vida. Objetivo: Determinar la versión equivalente del cuestionario de autocuidado para pacientes con asistencia ventricular definitiva en Colombia. Material y métodos: Estudio de tipo metodológico. Se llevó a cabo en seis etapas, con el propósito de garantizar la equivalencia del instrumento adaptado por medio de traducción inicial, síntesis de las traducciones, traducción inversa, revisión por parte del comité de expertos, presentación del instrumento a los autores y prueba de la versión prefinal. Resultados: Se realizó la traducción y la retrotraducción del instrumento. El 77 % de los expertos mencionaron que todos los ítems eran comprensibles y claros, pero el 33 % refirieron que en los ítems 3,5,6,7,8,10 y 11 requerían ajustes de forma. Conclusión: Se obtuvo la adaptación transcultural del cuestionario de autocuidado en pacientes con asistencia ventricular definitiva para el medio colombiano, conservando la equivalencia experiencial, conceptual, idiomática y semántica del instrumento original. (AU)


Introduction: In order to achieve an optimal life, patients with permanent implantable left ventricular assist devices face complex treatment regimens; they require acquiring knowledge and developing skills to guide their care. This makes it necessary for the nursing professional to have tools that allow them to identify the self-care level as a starting point to promote positive behaviors that allow adherence to their new lifestyle. Objective: To determine the equivalent version of the self-care questionnaire for patients with permanent ventricular assistance in Colombia. Material and methods: Methodological study. The process was carried out in six stages to guarantee the equivalence of the adapted instrument through a first translation, synthesis of translations, reverse translation, review by the expert committee, trial of the pre-final version and presentation of the instrument to the authors. Results: Translation and back-translation of the instrument were performed. 77% of the experts mentioned that all the items were understandable and clear, but 33% reported that items 3,5,6,7,8,10 and 11 required form adjustments. Conclusions: The cross-cultural adaptation of the self-care questionnaire in patients with permanent ventricular assistance for the Colombian environment was obtained, preserving the experiential, conceptual, idiomatic and semantic equivalence of the original instrument. (AU)


Assuntos
Humanos , Autocuidado , Insuficiência Cardíaca , Inquéritos e Questionários , Adaptação a Desastres , Colômbia , Coração Auxiliar , Disfunção Ventricular
8.
PLoS One ; 18(2): e0275465, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36763631

RESUMO

BACKGROUND: Adequate self-care behaviour is essential for patients with a left ventricular assist device (LVAD) to prevent complications, prolong life, and optimise quality of life. However, there were no valid and reliable measurements available to assess self-care behaviour among patients with LVAD. We have previously developed the 33-item LVAD self-care behaviour scale. OBJECTIVES: To evaluate psychometric properties of the 33-item LVAD self-care behaviour scale. METHODS AND RESULTS: Data on 127 patients with a LVAD in Israel, Japan, and the USA were analysed (mean age 51±14.3, 81% male). Exploratory factor analysis extracted three factors, and 13 items were excluded from the scale. Internal consistency assessed by Cronbach's alpha was acceptable for the total scale (α = 0.80) and the three subscales: Factor 1: Monitoring (α = 0.81), Factor 2: Heart failure self-care (α = 0.67), and Factor 3: LVAD self-care (α = 0.63). The 20-item version of the LVAD self-care behaviour scale had sufficient convergent validity with another scale that assessed self-care related to the driveline of LVAD (r = 0.47, p<0.001). Test-retest reliability was adequate (intraclass correlation coefficient = 0.58). CONCLUSIONS: The 20-item version of the LVAD self-care behaviour scale showed adequate validity and reliability. The scale is ready for use in clinical practice and research. Additional testing might further optimise the scale.


Assuntos
Coração Auxiliar , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Autocuidado , Reprodutibilidade dos Testes , Qualidade de Vida , Psicometria , Análise Fatorial , Inquéritos e Questionários
11.
Transl Vis Sci Technol ; 10(5): 12, 2021 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-34854915

RESUMO

Purpose: KeraVio is a corneal crosslinking treatment modality that utilizes violet light (VL)-emitting glasses and topical epithelium-on riboflavin administration. We focus on the new KeraVio protocol without riboflavin. This study aims to quantify the physiological intrastromal concentrations of riboflavin in corneas without riboflavin decreases and evaluate the biomechanics of corneas after VL irradiation. Methods: Twelve human donor corneas were included in this study and randomly categorized into four groups. The corneas underwent four imbibition techniques (physiological riboflavin without drops, epithelial [epi]-on with 0.05% flavin adenine dinucleotide [FAD], epi-off with FAD, and 0.1% riboflavin epi-off). Corneas in the FAD epi-on, FAD epi-off, and riboflavin epi-off groups were instilled with the respective solution every 2 minutes for 30 minutes. An ex vivo experiment was conducted with 24 porcine corneas arranged into three treatment groups and one control group. Corneas in the KeraVio with FAD epi-on group were treated with VL irradiation at 0.31 mW/cm2 for 4.8 hours (5.4 J/cm2) and simultaneously received FAD drops every 30 minutes during the VL irradiation. Corneas in the group with KeraVio without FAD epi-on were only treated with VL irradiation (5.4 J/cm2). Results: We identified the original physiological riboflavin of human corneal stroma at a concentration of 0.31 ± 0.03 µg/g, but its value was approximately 39-fold smaller than that in the 0.1% riboflavin epi-off group. The group with KeraVio without FAD and the standard corneal crosslinking group showed a significant increase in biomechanical stability compared with the controls, whereas the elastic modulus in the treated groups was equivalent. Conclusions: We preliminarily identified physiological riboflavin in human corneas without adding riboflavin drops. The VL exposure may strengthen the corneal biomechanics without requiring the use of additional riboflavin drops. Translational Relevance: We preliminarily identified physiological riboflavin in the human cornea without adding riboflavin drops. VL irradiation without riboflavin drops may increase the corneal stiffness using physiological riboflavin.


Assuntos
Colágeno , Fármacos Fotossensibilizantes , Animais , Córnea , Reagentes de Ligações Cruzadas , Módulo de Elasticidade , Humanos , Riboflavina , Suínos , Raios Ultravioleta
12.
BMC Ophthalmol ; 21(1): 317, 2021 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-34465309

RESUMO

INTRODUCTION: We present seven cases of infectious keratitis after corneal crosslinking (CXL) to attenuate keratoconus progression. METHODS: Of 524 consecutive patients who underwent CXL, 7 cases (4 males and 3 females; 21.5 ± 7.1 years) developed postoperative infectious keratitis were retrospectively reviewed. CXL was performed using the Dresden protocol or an accelerated protocol involving epithelial removal. RESULTS: All cases appeared normal on the day after surgery, but subsequently developed eye pain, blurred vision, corneal infiltration, inflammation of the anterior chamber, and ciliary injection on day 2 or 3. Methicillin-resistant Staphylococcus aureus was cultured from two eyes, methicillin-sensitive Staphylococcus aureus from two eyes, and Streptococcus pneumoniae from one eye. All detected bacteria were resistant to levofloxacin (LVFX). Five of the seven cases, especially four of the five severe cases with hypopyon, had a history of atopic dermatitis. All cases were observed after 2015. CONCLUSIONS: Infectious keratitis after CXL caused by microbes resistant to LVFX is increasing. In addition to careful postoperative observation of the cornea, preoperative evaluation of bacteria within the conjunctival sac evident on nasal swab cultures may be useful to identify potentially problematic microbes and inform the selection of appropriate antibiotics.


Assuntos
Ceratite , Ceratocone , Staphylococcus aureus Resistente à Meticilina , Córnea , Reagentes de Ligações Cruzadas , Feminino , Humanos , Ceratite/tratamento farmacológico , Ceratocone/tratamento farmacológico , Levofloxacino/uso terapêutico , Masculino , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Riboflavina/uso terapêutico
13.
ESC Heart Fail ; 8(6): 4539-4548, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34480412

RESUMO

AIMS: Improvement in exercise capacity is the primary goal of physical activity programmes for patients with heart failure (HF). Although activity programmes are effective for some patients, others do not benefit. Identifying factors related to a lack of improvement in submaximal exercise capacity may help us interpret findings and design new interventions. The aim of this study is to identify factors contributing to a lack of improvement in submaximal exercise capacity 3 months after physical activity advice or an exergame intervention in patients with HF. Additionally, we aimed to assess differences in lack of improvement in submaximal exercise capacity of patients whose baseline exercise capacity predicted a worse compared with better prognosis of HF. METHODS AND RESULTS: This secondary analysis of the HF-Wii study analysed baseline and 3 month data of the 6 min walk test (6MWT) from 480 patients (mean age 67 years, 72% male). Data were analysed separately in patients with a pre-defined 6 min walking distance at baseline of <300 m (n = 79) and ≥300 m (n = 401). Among patients with a baseline 6MWT of ≥300 m, 18% had deteriorated submaximal exercise capacity. In the multiple logistic regression analysis, lower baseline levels of self-reported physical activity [odds ratio (OR) = 0.77, 95% confidence interval (CI) = 0.60-0.97], lower baseline levels of cognitive function (OR = 0.87, 95%CI = 0.79-0.96) were significantly associated with lack of improvement in exercise capacity at 3 months. Not randomized to exergaming (OR = 0.63, 95%CI = 0.37-1.09) was likely (P = 0.097) to be associated with lack of improvement in exercise capacity at 3 months. Among the 79 patients with baseline 6MWT of <300 m, 41% (n = 32) did not improve 6MWT distance at 3 months. Independent predictors for the lack of improvement for 6MWT were New York Heart Association class III/IV (OR = 4.68, 95%CI = 1.08-20.35), higher levels of serum creatinine (OR = 1.02, 95%CI = 1.003-1.03), lower cognitive function (OR = 0.86, 95%CI = 0.75-0.99), and fewer anxiety symptoms (OR = 0.84, 95%CI = 0.72-0.98). CONCLUSIONS: Lower self-reported physical activity and cognitive impairment predict lack of improvement in submaximal exercise capacity in HF patients. Patients who have a worse prognosis (score <300 m at the 6MWT) are often frail and gain less in exercise capacity. These patients may need a more comprehensive approach to have an effect on exercise capacity, including an individually tailored exercise programme with aerobic exercise (if tolerated) and strength exercises.


Assuntos
Tolerância ao Exercício , Insuficiência Cardíaca , Idoso , Terapia por Exercício/métodos , Feminino , Humanos , Masculino , Prognóstico , Teste de Caminhada
14.
J Clin Med ; 10(12)2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-34203646

RESUMO

All corneal cross-linking techniques attenuated disease progression in patients with pediatric keratoconus for at least one year based on a meta-analysis. A standard and accelerated technique led to marked improvement in visual acuity. We determined the efficacy and safety of corneal cross-linking (CXL) in pediatric keratoconus by conducting a systematic review and meta-analysis. The PubMed and Cochrane databases were searched for relevant studies on the effects of standard, transepithelial, and/or accelerated CXL protocols in patients aged 18 years or younger. Standardized mean differences with 95% confidence intervals were calculated to compare the data collected at baseline and 12 months. The primary outcomes were maximum keratometry (Kmax) and uncorrected visual acuity (UCVA), and the secondary outcomes were the thinnest corneal thickness (TCT), best-corrected visual acuity (BCVA), and manifest refraction spherical equivalent or cylindrical refraction. Our search yielded 7913 publications, of which 26 were included in our systematic review and 21 were included in the meta-analysis. Standard CXL significantly improved the Kmax, UCVA, and BCVA, and significantly decreased the TCT. Accelerated CXL significantly improved UCVA and BCVA. In the transepithelial and accelerated-transepithelial CXL methods, each measurable parameter did not change after treatments. All CXL techniques attenuated disease progression in patients with pediatric keratoconus for at least one year. Standard and accelerated CXL led to marked improvement in visual acuity.

15.
Eur J Cardiovasc Nurs ; 20(5): 501-512, 2021 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-33864066

RESUMO

AIMS: The European Heart Failure Self-care Behaviour Scale (EHFScBS) is frequently used to assess self-care behaviours in patients with heart failure. This scale has been translated into several languages. The COnsensus-based Standards for the selection of health status Measurement INstrument (COSMIN) Risk of Bias checklist for a systematic review has recently been published. The aim of the study was to assess the methodological quality of studies reporting on psychometric evaluations of the EHFScBS using the COSMIN methodology. METHODS AND RESULTS: To identify relevant studies, a systematic literature search was performed using PubMed and CINAHL databases in December 2019 and the search was updated in June 2020. The COSMIN Risk of Bias checklist was used to assess the methodological quality. In total, 21 relevant studies were rated. The overall methodological quality of content validity was rated as inadequate in 17 studies and a main reason of the inadequate rating was a lack of patient involvement. Structural validity was adequately addressed in 12 studies, internal consistency in seven, and eight of 11 studies reporting on construct validity and had good methodological quality. CONCLUSION: Although the use of the EHFScBS has grown rapidly and the validity and reliability are reported to be good, the methodological quality of studies reporting on psychometric properties of the scale is not optimal. Further studies are necessary to strengthen the evidence on validity and reliability of the EHFScBS.


Assuntos
Insuficiência Cardíaca , Autocuidado , Lista de Checagem , Insuficiência Cardíaca/terapia , Humanos , Psicometria , Reprodutibilidade dos Testes , Inquéritos e Questionários
16.
J Clin Med ; 10(4)2021 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-33670732

RESUMO

We aimed to predict keratoconus progression and the need for corneal crosslinking (CXL) using deep learning (DL). Two hundred and seventy-four corneal tomography images taken by Pentacam HR® (Oculus, Wetzlar, Germany) of 158 keratoconus patients were examined. All patients were examined two times or more, and divided into two groups; the progression group and the non-progression group. An axial map of the frontal corneal plane, a pachymetry map, and a combination of these two maps at the initial examination were assessed according to the patients' age. Training with a convolutional neural network on these learning data objects was conducted. Ninety eyes showed progression and 184 eyes showed no progression. The axial map, the pachymetry map, and their combination combined with patients' age showed mean AUC values of 0.783, 0.784, and 0.814 (95% confidence interval (0.721-0.845) (0.722-0.846), and (0.755-0.872), respectively), with sensitivities of 87.8%, 77.8%, and 77.8% ((79.2-93.7), (67.8-85.9), and (67.8-85.9)) and specificities of 59.8%, 65.8%, and 69.6% ((52.3-66.9), (58.4-72.6), and (62.4-76.1)), respectively. Using the proposed DL neural network model, keratoconus progression can be predicted on corneal tomography maps combined with patients' age.

17.
Cornea ; 40(6): 690-695, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33009090

RESUMO

PURPOSE: To evaluate changes in the anterior chamber of eyes that have undergone Descemet membrane endothelial keratoplasty (DMEK) and to identify factors that affect these changes. METHODS: This retrospective study included 25 pseudophakic eyes of 25 patients who underwent DMEK. We determined the preoperative and postoperative values of the best spectacle-corrected visual acuity, spherical equivalent (SE), anterior chamber volume (ACV), anterior chamber depth (ACD), central corneal thickness (CCT), and scleral spur angle (SSA) evaluated using anterior segment optical coherence tomography and iris damage score and iris posterior synechiae score. We defined ∆ as the average change rate from the preoperative to postoperative value for each factor at 1 month (SE at 6-12 months) postoperatively. We also analyzed correlations between ∆ACV, ∆SE, and other preexisting factors. RESULTS: Compared with the preoperative ACV value (128 ± 28 mm3), the postoperative value significantly increased to 155 ± 21 mm3 (P < 0.001); ∆SE was +1.01 ± 1.09 diopters. ∆ACV was negatively correlated with preoperative ACD (R = 0.643, P < 0.001) and SSA (R = 0.555, P = 0.001) and positively correlated with ∆ACD (R = 0.799, P < 0.001) and ∆SSA (R = 0.608, P < 0.001). ∆CCT, iris damage score, and iris posterior synechiae score were not significantly correlated with ∆ACV. ∆SE was positively correlated with ∆ACV, ∆ACD, and ∆SSA (R = 0.680, 0.455, and 0.478; P < 0.001, <0.05, and <0.05, respectively). CONCLUSIONS: An increase in the ACV and hyperopic change was noted after successful DMEK, especially in eyes with narrow-angled shallow anterior chambers.


Assuntos
Câmara Anterior/patologia , Vesícula/cirurgia , Doenças da Córnea/cirurgia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs/cirurgia , Refração Ocular , Idoso , Idoso de 80 Anos ou mais , Vesícula/fisiopatologia , Doenças da Córnea/fisiopatologia , Feminino , Distrofia Endotelial de Fuchs/fisiopatologia , Humanos , Hiperopia/fisiopatologia , Iris/fisiopatologia , Masculino , Refração Ocular/fisiologia , Estudos Retrospectivos , Acuidade Visual/fisiologia
18.
PLoS One ; 15(10): e0240458, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33052928

RESUMO

PURPOSE: To evaluate the corneal characteristics after Descemet membrane endothelial keratoplasty (DMEK) compared with normal corneas. METHODS: Patients who underwent DMEK at Yokohama Minami Kyosai Hospital were included and prospectively evaluated pre-operatively and at postoperative months 1, 3, 6, and 12, and compared to healthy controls. Corneal characteristics evaluated included corneal curvature (keratometric value [KV]; D), central corneal thickness (CCT), peripheral corneal thickness (PCT), and corneal higher-order aberrations [HOAs] at 6.0 mm diameter, calculated by anterior segment optical coherence tomography and logarithm of the minimal angle of resolution [logMAR]. RESULTS: A total of 30 eyes of 30 patients (6 men, 24 women, mean age 73.4 ± 7.4 years) were included and compared with 31 age-matched healthy control eyes (13 men, 18 women; mean age 73.0 ± 6.7 years). LogMAR after DMEK improved from 0.87 ± 0.07 preoperatively to 0.04 ± 0.07 at 12 months postoperatively (p<0.001). Although anterior KVs of DMEK eyes were similar to those of control eyes, posterior KVs were significantly larger (-6.4 ± 0.3 D vs. -6.3 ± 0.2 D; p = 0.02). Total HOAs after DMEK improved from 1.94 ± 1.05 µm preoperatively to 1.05 ± 0.16 µm at 12 months postoperatively (p<0.001), which was significantly higher than that in control eyes (0.63 ± 0.06) (p<0.001). Despite the similar CCTs in the two groups, the PCT was significantly larger in DMEK eyes (704 ± 41 µm vs 669 ± 38 µm, p = 0.002) at 12 months. CONCLUSION: Despite achieving good visual function and excellent corneal clarity, eyes that underwent DMEK showed a steeper posterior KV and higher corneal HOAs than normal eyes even at 12 months after surgery.


Assuntos
Córnea/diagnóstico por imagem , Córnea/fisiologia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Córnea/cirurgia , Feminino , Humanos , Masculino , Estudos Prospectivos , Tomografia de Coerência Óptica , Acuidade Visual
19.
PLoS One ; 15(6): e0234202, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32525919

RESUMO

PURPOSE: To investigate the factors associated with endothelial survival after Descemet's membrane endothelial keratoplasty (DMEK) in eyes of Asian patients with bullous keratopathy (BK). METHODS: In this retrospective, consecutive interventional case series, 72 eyes of 72 patients who underwent DMEK were evaluated. Best corrected visual acuity (BCVA) and corneal endothelial cell density (ECD) were assessed at 12 months postoperatively. Multiple regression analysis was performed to assess parameters such as age, sex, axial length, preoperative visual acuity, re-bubbling, the ratio of graft to cornea area, iris damage scores, types of filling gases, air or SF6 volume in the anterior chamber (AC) on postoperative day 1, and ECD loss rates at 12 months postoperatively. RESULTS: BCVA improved significantly at 12 months after DMEK (P < .001). The rate of ECD loss at 12 months after DMEK was 54.4 ± 16.1%. Multiple linear regression analysis showed that a larger ratio of graft to corneal area (P = 0.0061) and higher donor ECD (P = 0.042) were the primary factors for a lower ECD loss rate at 12 months after DMEK. CONCLUSION: A relatively larger graft size compared to the host cornea and more donor ECD might help endothelial survival in patients with BK. Moreover, for such patients, the surgeon should attempt to use a relatively larger graft size when performing DMEK, particularly in Asian eyes.


Assuntos
Doenças da Córnea/patologia , Lâmina Limitante Posterior/patologia , Células Endoteliais/patologia , Adulto , Idoso , Ásia , Contagem de Células , Sobrevivência Celular , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...