Physiol Meas ; 34(10): 1281-92, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24021865

RESUMO

Public concern for the compatibility of electromagnetic (EM) sources with active implantable medical devices (AIMD) has prompted the development of new systems that can perform accurate exposure studies. EM field interference with active cardiac implants (e.g. implantable cardioverter-defibrillators (ICDs)) can be critical. This paper describes a magnetic field (MF) exposure system and the method developed for testing the immunity of ICD to continuous-wave MFs. The MFs were created by Helmholtz coils, housed in a Faraday cage. The coils were able to produce highly uniform MFs up to 4000 µT at 50 Hz and 3900 µT at 60 Hz, within the test space. Four ICDs were tested. No dysfunctions were found in the generated MFs. These results confirm that the tested ICDs were immune to low frequency MFs.


Assuntos
Desfibriladores Implantáveis , Campos Magnéticos , Teste de Materiais/métodos , Meio Ambiente , Desenho de Equipamento , Teste de Materiais/instrumentação
2.
Physiol Meas ; 34(4): 391-405, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23481406

RESUMO

This paper presents the design of a four electrode impedance measurement circuit dedicated to bioimpedance embedded applications. It extends the use of the AD5933 measurement chip to allow it to operate in a four electrode configuration in order to limit the effects of the parasitic impedances between the medium under test and the electrodes. The circuit has shown a good measurement accuracy on various test circuits. In association with a four microband electrode system it has been successfully used to characterize small physiological samples (50 µl) with conductivities ranging from 0.14 to 1.2 S m(-1). It can be used as an alternative bioimpedance measurement approach for embedded applications operating in the four electrode configuration.


Assuntos
Espectroscopia Dielétrica/métodos , Eletrônica/instrumentação , Calibragem , Eletricidade , Eletrodos , Íons , Soluções
7.
Rev. cuba. med. trop ; 35(3): 303-16, 1983.
Artigo em Espanhol | LILACS | ID: lil-19456

RESUMO

Se exponen los hallazgos clinicos y epidemiologicos obtenidos de un brote de 26 casos de larva migrans cutanea en cuatro circulos infantiles de la antigua regional de salud San Jose-Camilo Cienfuegos.Se senalan los resultados obtenidos con diferentes metodos terapeuticos que se utilizaron en los pacientes afectados. Se recomiendan medidas para la prevención de futuros brotes


Assuntos
Surtos de Doenças , Larva Migrans , Cuba
10.
Rev. cuba. med ; 18(2): 149-57, mar.-abr. 1979. ilus
Artigo em Espanhol | CUMED | ID: cum-12066

RESUMO

Se presenta un caso de síndrome de Rothmund-Thomson, el cual resulta de interés por lo florido del cuadro clínico en este paciente y por la rareza de esta afección, ya que hasta el presente sólo existen informes de más o menos 25 casos en la literatura médica mundial. Se revisa la bibliografía al respecto y se expone el cuadro clínico característico, así como la frecuencia con que se presentan las alteraciones fundamentales(AU)


Assuntos
INFORME DE CASO , Humanos , Masculino , Adolescente , Síndrome de Rothmund-Thomson
13.
Rev. cuba. med ; 7(4-5-6): 429-438, 1968. ilus
Artigo em Espanhol | CUMED | ID: cum-27242

RESUMO

Se presentan siete pacientes afectados de amiloidosis cutánea primitiva localizada, con breve revisión de la bibliografía actual. Se recomienda la radioterapia superficial para el alivio rápido de la sintomatología, debiendo continuarse con el empleo de ungüento corticoesteroideos. Se recomienda frente a una lesión pruriginosa, pigmentada de alguna evolución pensar en el amiloidosis cutánea localizada. Se piensa que esta dermatosis no es tan rara en el consultorio Dermatológico y sí a veces olvidada(AU)