Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 8(1): 4241, 2018 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-29523796

RESUMO

Pharmacological administration of FGF21 analogues has shown robust body weight reduction and lipid profile improvement in both dysmetabolic animal models and metabolic disease patients. Here we report the design, optimization, and characterization of a long acting glyco-variant of FGF21. Using a combination of N-glycan engineering for enhanced protease resistance and improved solubility, Fc fusion for further half-life extension, and a single point mutation for improving manufacturability in Chinese Hamster Ovary cells, we created a novel FGF21 analogue, Fc-FGF21[R19V][N171] or PF-06645849, with substantially improved solubility and stability profile that is compatible with subcutaneous (SC) administration. In particular, it showed a low systemic clearance (0.243 mL/hr/kg) and long terminal half-life (~200 hours for intact protein) in cynomolgus monkeys that approaches those of monoclonal antibodies. Furthermore, the superior PK properties translated into robust improvement in glucose tolerance and the effects lasted 14 days post single SC dose in ob/ob mice. PF-06645849 also caused greater body weight loss in DIO mice at lower and less frequent SC doses, compared to previous FGF21 analogue PF-05231023. In summary, the overall PK/PD and pharmaceutical profile of PF-06645849 offers great potential for development as weekly to twice-monthly SC administered therapeutic for chronic treatment of metabolic diseases.


Assuntos
Fatores de Crescimento de Fibroblastos/farmacocinética , Animais , Células CHO , Cricetinae , Cricetulus , Fatores de Crescimento de Fibroblastos/administração & dosagem , Fatores de Crescimento de Fibroblastos/química , Glicosilação , Células HEK293 , Humanos , Injeções Subcutâneas , Macaca fascicularis , Taxa de Depuração Metabólica , Camundongos , Estabilidade Proteica , Proteólise , Distribuição Tecidual
2.
MAbs ; 10(1): 81-94, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28991504

RESUMO

A large body of data exists demonstrating that neonatal Fc receptor (FcRn) binding of an IgG via its Fc CH2-CH3 interface trends with the pharmacokinetics (PK) of IgG. We have observed that PK of IgG molecules vary widely, even when they share identical Fc domains. This led us to hypothesize that domains distal from the Fc could contribute to FcRn binding and affect PK. In this study, we explored the role of these IgG domains in altering the affinity between IgG and FcRn. Using a surface plasmon resonance-based assay developed to examine the steady-state binding affinity (KD) of IgG molecules to FcRn, we dissected the contributions of IgG domains in modulating the affinity between FcRn and IgG. Through analysis of a broad collection of therapeutic antibodies containing more than 50 unique IgG molecules, we demonstrated that variable domains, and in particular complementarity-determining regions (CDRs), significantly alter binding affinity to FcRn in vitro. Furthermore, a panel of IgG molecules differing only by 1-5 mutations in CDRs altered binding affinity to FcRn in vitro, by up to 79-fold, and the affinity values correlated with calculated isoelectric point values of both variable domains and CDR-L3. In addition, tighter affinity values trend with faster in vivo clearance of a set of IgG molecules differing only by 1-3 mutations in human FcRn transgenic mice. Understanding the role of CDRs in modulation of IgG affinity to FcRn in vitro and their effect on PK of IgG may have far-reaching implications in the optimization of IgG therapeutics.


Assuntos
Anticorpos Monoclonais/farmacocinética , Regiões Determinantes de Complementaridade/metabolismo , Antígenos de Histocompatibilidade Classe I/metabolismo , Imunoglobulina G/metabolismo , Receptores Fc/metabolismo , Animais , Anticorpos Monoclonais/genética , Anticorpos Monoclonais/imunologia , Especificidade de Anticorpos , Sítios de Ligação de Anticorpos , Células CHO , Regiões Determinantes de Complementaridade/genética , Regiões Determinantes de Complementaridade/imunologia , Cricetulus , Antígenos de Histocompatibilidade Classe I/genética , Antígenos de Histocompatibilidade Classe I/imunologia , Humanos , Imunoglobulina G/genética , Imunoglobulina G/imunologia , Masculino , Camundongos Transgênicos , Mutação , Variantes Farmacogenômicos , Ligação Proteica , Domínios e Motivos de Interação entre Proteínas , Receptores Fc/genética , Receptores Fc/imunologia
3.
MAbs ; 10(2): 244-255, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29271699

RESUMO

Implementation of in vitro assays that correlate with in vivo human pharmacokinetics (PK) would provide desirable preclinical tools for the early selection of therapeutic monoclonal antibody (mAb) candidates with minimal non-target-related PK risk. Use of these tools minimizes the likelihood that mAbs with unfavorable PK would be advanced into costly preclinical and clinical development. In total, 42 mAbs varying in isotype and soluble versus membrane targets were tested in in vitro and in vivo studies. MAb physicochemical properties were assessed by measuring non-specific interactions (DNA- and insulin-binding ELISA), self-association (affinity-capture self-interaction nanoparticle spectroscopy) and binding to matrix-immobilized human FcRn (surface plasmon resonance and column chromatography). The range of scores obtained from each in vitro assay trended well with in vivo clearance (CL) using both human FcRn transgenic (Tg32) mouse allometrically projected human CL and observed human CL, where mAbs with high in vitro scores resulted in rapid CL in vivo. Establishing a threshold value for mAb CL in human of 0.32 mL/hr/kg enabled refinement of thresholds for each in vitro assay parameter, and using a combinatorial triage approach enabled the successful differentiation of mAbs at high risk for rapid CL (unfavorable PK) from those with low risk (favorable PK), which allowed mAbs requiring further characterization to be identified. Correlating in vitro parameters with in vivo human CL resulted in a set of in vitro tools for use in early testing that would enable selection of mAbs with the greatest likelihood of success in the clinic, allowing costly late-stage failures related to an inadequate exposure profile, toxicity or lack of efficacy to be avoided.


Assuntos
Anticorpos Monoclonais/farmacocinética , Descoberta de Drogas/métodos , Técnicas In Vitro , Modelos Animais , Animais , Humanos , Camundongos , Camundongos Transgênicos
4.
MAbs ; 8(6): 1064-78, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27232760

RESUMO

Therapeutic antibodies continue to develop as an emerging drug class, with a need for preclinical tools to better predict in vivo characteristics. Transgenic mice expressing human neonatal Fc receptor (hFcRn) have potential as a preclinical pharmacokinetic (PK) model to project human PK of monoclonal antibodies (mAbs). Using a panel of 27 mAbs with a broad PK range, we sought to characterize and establish utility of this preclinical animal model and provide guidance for its application in drug development of mAbs. This set of mAbs was administered to both hemizygous and homozygous hFcRn transgenic mice (Tg32) at a single intravenous dose, and PK parameters were derived. Higher hFcRn protein tissue expression was confirmed by liquid chromatography-high resolution tandem mass spectrometry in Tg32 homozygous versus hemizygous mice. Clearance (CL) was calculated using non-compartmental analysis and correlations were assessed to historical data in wild-type mouse, non-human primate (NHP), and human. Results show that mAb CL in hFcRn Tg32 homozygous mouse correlate with human (r(2) = 0.83, r = 0.91, p < 0.01) better than NHP (r(2) = 0.67, r = 0.82, p < 0.01) for this dataset. Applying simple allometric scaling using an empirically derived best-fit exponent of 0.93 enabled the prediction of human CL from the Tg32 homozygous mouse within 2-fold error for 100% of mAbs tested. Implementing the Tg32 homozygous mouse model in discovery and preclinical drug development to predict human CL may result in an overall decreased usage of monkeys for PK studies, enhancement of the early selection of lead molecules, and ultimately a decrease in the time for a drug candidate to reach the clinic.


Assuntos
Anticorpos Monoclonais/farmacocinética , Descoberta de Drogas/métodos , Antígenos de Histocompatibilidade Classe I/genética , Receptores Fc/genética , Animais , Anticorpos Monoclonais/administração & dosagem , Anticorpos Monoclonais/análise , Cromatografia Líquida , Hemizigoto , Homozigoto , Humanos , Macaca fascicularis , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Modelos Animais , Valor Preditivo dos Testes , Espectrometria de Massas em Tandem
5.
Pharm Res ; 31(10): 2810-21, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24844406

RESUMO

PURPOSE: To assess the application of succinimidyl iodobenzoate (SIB) iodination method in labeling biotherapeutics to study their pharmacokinetics (PK) and biodistribution. METHOD: An IgG molecule (protein-01) and a 40 KDa protein (protein-02) were evaluated. Pharmacokinetics (PK) and biodistribution of the radiolabeled IgG ((125)I-protein-01) in mice compared parameters from SIB and Iodogen protein iodination labeling methods. In addition, PK of radiolabeled 40 KDa protein ((125)I-protein-02) using SIB was compared with non-labeled protein-02 analyzed by ligand binding assay (LBA). RESULTS: Up to 72 h following a single IP injection to mice, the percentage of "free-label" determined by the soluble counts after TCA precipitation to total radioactivity in serum samples was 2.8-49.4% vs. <1.0% for (125)I-protein-01 iodinated via Iodogen or SIB methods, respectively, suggesting a higher in vivo stability of (125)I-protein-01 labeled via the SIB method. The serum exposure of (125)I-protein-01 was two-fold higher, and correspondingly, the tissue exposure was also higher (averaging 3.6 fold at 168 h) when using SIB protein labeling method than when using the Iodogen method. In addition, following subcutaneous (SC) administration to mice, the serum exposure of (125)I-protein-02 labeled via SIB method was similar to protein-02 measure by LBA. CONCLUSION: In this study, iodination of proteins using SIB methodology has overcome the dehalogenation problem in vivo which is inherent in Iodogen method, and PK parameters of a protein iodinated via SIB were comparable to the un-labeled protein measured by LBA. The SIB iodination method is an improved labeling approach for biotherapeutics used in studying PK and biodistribution characteristics.


Assuntos
Anticorpos Monoclonais/farmacocinética , Monitoramento de Medicamentos/métodos , Iodobenzoatos/química , Ureia/análogos & derivados , Absorção Fisiológica , Animais , Anticorpos Monoclonais/sangue , Área Sob a Curva , Benzoatos/química , Eletroforese em Gel de Poliacrilamida , Radioisótopos do Iodo , Marcação por Isótopo/métodos , Taxa de Depuração Metabólica , Camundongos , Distribuição Tecidual , Compostos de Trialquitina/química , Ureia/química
6.
J Immunol Methods ; 397(1-2): 28-36, 2013 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-23994108

RESUMO

A comparison of four different ligand-binding assay technology platforms (ELISA, Meso Scale Discovery®, Gyros® and AlphaLISA®) was conducted using quantitative assays for the measurement of a human IgG1 monoclonal antibody (MAb) in rat serum. The assays used common reagents for Fc-specific measurement to determine total levels of a human IgG MAb drug analyte, and all were fully optimized for use on each platform. Mock MAb study samples were prepared and analyzed using all platforms to assess assay performance. Assay parameters such as sensitivity, dynamic range, minimum required dilution and sample volume as well as other considerations such as per-run cost, technology availability, requisite equipment and necessary reagent modifications were evaluated toward the determination of a default go-to assay platform for monoclonal antibody biotherapeutics in this laboratory. Based primarily on superior assay performance, Meso Scale Discovery and Gyros were selected from the four technologies evaluated as our default platforms for non-regulated (discovery) study support. As an adjunct, immunoaffinity LC-MS/MS was explored as an alternate platform for generic Fc quantitation and was found to perform similarly to the ligand-binding assays.


Assuntos
Anticorpos Monoclonais/farmacocinética , Ensaio de Imunoadsorção Enzimática , Imunoglobulina G/sangue , Animais , Anticorpos Monoclonais/sangue , Anticorpos Monoclonais/imunologia , Cromatografia Líquida , Humanos , Imunoglobulina G/imunologia , Ratos , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...