Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
1.
ASAIO J ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38595112

RESUMO

Prior studies indicate donor age-recipient age (DA-RA) difference may be of prognostic value in adolescents, although not adults. We aim to analyze the relationship between DA-RA difference and long-term survival of young adult heart transplantation (HTx) recipients. First-time, single-organ HTx recipients aged 18-30 who underwent HTx between 2010 and 2020 were analyzed from the United Network for Organ Sharing (UNOS) registry. Four cohorts were created based on DA-RA difference. The primary outcome was 5 year post-HTx survival. Secondary outcome was post-HTx complications. One thousand eight hundred three donor-recipient pairs were divided into four groups: DA-RA < 0, 0 ≤ DA-RA < 10, 10 ≤ DA-RA < 20, and DA-RA ≥ 20 with 682 (37.8%), 651 (36.1%), 356 (19.7%), 114 (6.3%) pairs in each cohort, respectively. The estimated 5 year survival of the DA-RA ≥ 20 cohort was 66.5% compared to the other three groups at ~75%. After adjustment, DA-RA ≥ 20 was independently associated with worse survival compared to DA-RA < 0 (adjusted hazard ratio [HR] = 1.55; 95% confidence interval [CI] = 1.06-2.27; log-rank p = 0.008). There was no significant difference in complication incidence across cohorts. Among young adults, accepting a donor heart more than 20 years older than the recipient was associated with worse 5 year survival. We did not detect a significant difference up to 20 years. This information may help guide appropriate donor selection in the young adult population.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38503386

RESUMO

BACKGROUND: Severe primary graft dysfunction (PGD) is a major cause of early mortality after heart transplant, but the impact of donor organ preservation conditions on severity of PGD and survival has not been well characterized. METHODS: Data from US adult heart-transplant recipients in the Global Utilization and Registry Database for Improved Heart Preservation-Heart Registry (NCT04141605) were analyzed to quantify PGD severity, mortality, and associated risk factors. The independent contributions of organ preservation method (traditional ice storage vs controlled hypothermic preservation) and ischemic time were analyzed using propensity matching and logistic regression. RESULTS: Among 1,061 US adult heart transplants performed between October 2015 and December 2022, controlled hypothermic preservation was associated with a significant reduction in the incidence of severe PGD compared to ice (6.6% [37/559] vs 10.4% [47/452], p = 0.039). Following propensity matching, severe PGD was reduced by 50% (6.0% [17/281] vs 12.1% [34/281], respectively; p = 0.018). The Kaplan-Meier terminal probability of 1-year mortality was 4.2% for recipients without PGD, 7.2% for mild or moderate PGD, and 32.1%, for severe PGD (p < 0.001). The probability of severe PGD increased for both cohorts with longer ischemic time, but donor hearts stored on ice were more likely to develop severe PGD at all ischemic times compared to controlled hypothermic preservation. CONCLUSIONS: Severe PGD is the deadliest complication of heart transplantation and is associated with a 7.8-fold increase in probability of 1-year mortality. Controlled hypothermic preservation significantly attenuates the risk of severe PGD and is a simple yet highly effective tool for mitigating post-transplant morbidity.

3.
ASAIO J ; 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38446870

RESUMO

Prior studies reveal adverse effects of transfusion on cardiac surgery, but little is known of transfusion impact on heart transplantation. First-time, single-organ adult heart transplant recipients between January 1, 2010, and December 31, 2020, were included, stratified above or below a model for end-stage liver disease excluding international normalized ratio (MELD-XI) score of 9.4, and propensity score matched to their nearest neighbor. A 90 day landmark analysis within each cohort was also performed. Unadjusted analysis showed transfusion recipients, MELD-XI ≥9.4, were more likely to experience post-heart transplantation mortality (Hazard Ratio (HR), 1.352 [95% Confidence Interval (CI), 1.239-1.477], p < 0.001), persisting after adjustment for potential confounders (adjusted HR, 1.211 [95% CI, 1.100-1.335], p < 0.001) and after propensity-score matching (HR, 1.174 [95% CI, 1.045-1.319], p = 0.007). Post-transplant length of stay was longer (25.9 vs. 23.2 days, p < 0.001). Post-transplant dialysis was more common (18.7 vs. 15.9%, p = 0.009). There was no survival difference on 90 day landmarked analysis (p = 0.108). With MELD-XI <9.4, there was slight survival detriment among transfusion recipients on univariable analysis (HR, 1.111 [95% CI, 1.001-1.234], p = 0.049) but not on multivariable analysis (adjusted HR, 1.061 [95% CI, 0.952-1.181], p = 0.285). There was similar survival after propensity-score matching (HR, 1.032 [95% CI, 0.903-1.180], p = 0.642) and on landmark analysis (p = 0.581). Ultimately, transfusion was associated with worse post-heart transplantation outcomes among recipients with a MELD-XI ≥9.4.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38460099

RESUMO

OBJECTIVES: Transaxillary access is the most popular alternative to transfemoral transcatheter aortic valve replacement. Although left transaxillary access is generally preferred, right transaxillary transcatheter aortic valve replacement could be challenging because of the opposing axillary artery and aortic curvatures, which may warrant procedural modifications to improve alignment. Our aim is to compare our single center's outcomes for left and right transaxillary access groups and to evaluate procedural modifications for facilitating right transaxillary transcatheter aortic valve replacement. METHODS: Patient characteristics and outcomes were compared for consecutive left or right axillary TAVRs performed from 6/2016 to 6/2022 with SAPIEN 3. The effects of our previously reported "flip-n-flex" technique on procedural efficiency and new conduction disturbances were subanalyzed in the right axillary group. RESULTS: Right and left transaxillary transcatheter aortic valve replacement were performed in 25 (18 with the "flip-n-flex" technique) and 26 patients, respectively. There were no significant differences between patient characteristics or outcomes. Right axillary subanalysis showed the "flip-n-flex" technique group had significantly shorter fluoroscopy times (21.2 ± 6.2 vs 29.6 ± 12.4 min, p = 0.03) and a trend towards less permanent pacemaker implantation (6.3% vs. 42.9%, p = 0.07) compared to the group without "flip-n-flex". CONCLUSIONS: In our study, despite anatomical challenges, right transaxillary transcatheter aortic valve replacement is comparable to left access. The "flip-n-flex" technique advances right transaxillary as an appealing access for patients with few options.

5.
ASAIO J ; 70(5): 388-395, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38300893

RESUMO

The last several years have seen a rise in use of mechanical circulatory support (MCS) to bridge heart transplant recipients. A controlled hypothermic organ preservation system, the SherpaPak Cardiac Transport System (SCTS), was introduced in 2018 and has grown in utilization with reports of improved posttransplant outcomes. The Global Utilization And Registry Database for Improved heArt preservatioN (GUARDIAN)-Heart registry is an international, multicenter registry assessing outcomes after transplant using the SCTS. This analysis examines outcomes in recipients bridged with various MCS devices in the GUARDIAN-Heart Registry. A total of 422 recipients with donor hearts transported using SCTS were included and identified. Durable ventricular assist devices (VADs) were used exclusively in 179 recipients, temporary VADs or intra-aortic balloon pump (IABP) in 197, and extracorporeal membrane oxygenation (ECMO) in 14 recipients. Average ischemic times were over 3.5 hours in all cohorts. Severe primary graft dysfunction (PGD) posttransplant increased across groups (4.5% VAD, 5.1% temporary support, 21.4% ECMO), whereas intensive care unit (ICU) length of stay (18.2 days) and total hospital stay (39.4 days) was longer in the ECMO cohort than the VAD and IABP groups. A comparison of outcomes of MCS bridging in SCTS versus traditional ice revealed significantly lower rates of both moderate/severe right ventricular (RV) dysfunction and severe PGD in the SCTS cohort; however, upon propensity matching only the reductions in moderate/severe RV dysfunction were statistically significant. Use of SCTS in transplant recipients with various bridging strategies results in excellent outcomes.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Coração Auxiliar , Humanos , Transplante de Coração/métodos , Masculino , Pessoa de Meia-Idade , Feminino , Adulto , Oxigenação por Membrana Extracorpórea/métodos , Preservação de Órgãos/métodos , Resultado do Tratamento , Sistema de Registros/estatística & dados numéricos , Balão Intra-Aórtico/métodos , Balão Intra-Aórtico/estatística & dados numéricos , Idoso , Estudos Retrospectivos
6.
Circulation ; 149(17): 1341-1353, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38235580

RESUMO

BACKGROUND: Cardiolipin is a mitochondrial-specific phospholipid that maintains integrity of the electron transport chain (ETC) and plays a central role in myocardial ischemia/reperfusion injury. Tafazzin is an enzyme that is required for cardiolipin maturation. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) use to provide hemodynamic support for acute myocardial infarction has grown exponentially, is associated with poor outcomes, and is under active clinical investigation, yet the mechanistic effect of VA-ECMO on myocardial damage in acute myocardial infarction remains poorly understood. We hypothesized that VA-ECMO acutely depletes myocardial cardiolipin and exacerbates myocardial injury in acute myocardial infarction. METHODS: We examined cardiolipin and tafazzin levels in human subjects with heart failure and healthy swine exposed to VA-ECMO and used a swine model of closed-chest myocardial ischemia/reperfusion injury to evaluate the effect of VA-ECMO on cardiolipin expression, myocardial injury, and mitochondrial function. RESULTS: Cardiolipin and tafazzin levels are significantly reduced in the left ventricles of individuals requiring VA-ECMO compared with individuals without VA-ECMO before heart transplantation. Six hours of exposure to VA-ECMO also decreased left ventricular levels of cardiolipin and tafazzin in healthy swine compared with sham controls. To explore whether cardiolipin depletion by VA-ECMO increases infarct size, we performed left anterior descending artery occlusion for a total of 120 minutes followed by 180 minutes of reperfusion in adult swine in the presence and absence of MTP-131, an amphipathic molecule that interacts with cardiolipin to stabilize the inner mitochondrial membrane. Compared with reperfusion alone, VA-ECMO activation beginning after 90 minutes of left anterior descending artery occlusion increased infarct size (36±8% versus 48±7%; P<0.001). VA-ECMO also decreased cardiolipin and tafazzin levels, disrupted mitochondrial integrity, reduced electron transport chain function, and promoted oxidative stress. Compared with reperfusion alone or VA-ECMO before reperfusion, delivery of MTP-131 before VA-ECMO activation reduced infarct size (22±8%; P=0.03 versus reperfusion alone and P<0.001 versus VA-ECMO alone). MTP-131 restored cardiolipin and tafazzin levels, stabilized mitochondrial function, and reduced oxidative stress in the left ventricle. CONCLUSIONS: We identified a novel mechanism by which VA-ECMO promotes myocardial injury and further identify cardiolipin as an important target of therapy to reduce infarct size and to preserve mitochondrial function in the setting of VA-ECMO for acute myocardial infarction.

7.
J Heart Lung Transplant ; 43(4): 673-680, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38163452

RESUMO

BACKGROUND: The prevalence of end-stage heart failure and patients who could benefit from heart transplantation requires an expansion of the donor pool, relying on the transplant community to continually re-evaluate and expand the use of extended criteria donor organs. Introduction of new technologies such as the Paragonix SherpaPak Cardiac Transport System aids in this shift. We seek to analyze the impact of the SherpaPak system on recipient outcomes who receive extended criteria organs in the GUARDIAN-Heart Registry. METHODS: Between October 2015 and December 2022, 1,113 adults from 15 US centers receiving donor hearts utilizing either SherpaPak (n = 560) or conventional ice storage (ice, n = 453) were analyzed from the GUARDIAN-Heart Registry using summary statistics. A previously published set of criteria was used to identify extended criteria donors, which included 193 SherpaPak and 137 ice. RESULTS: There were a few baseline differences among recipients in the 2 cohorts; most notably, IMPACT scores, distance traveled, and total ischemic time were significantly greater in SherpaPak, and significantly more donor hearts in the SherpaPak cohort had >4 hours total ischemia time. Posttransplant mechanical circulatory support utilization (SherpaPak 22.3% vs ice 35.0%, p = 0.012) and new extracorporeal membrane oxygenation/ventricular assist device (SherpaPak 7.8% vs ice 15.3%, p = 0.033) was significantly reduced, and the rate of severe primary graft dysfunction (SherpaPak 6.2% vs ice 13.9%, p = 0.022) was significantly reduced by over 50% in hearts preserved using SherpaPak. One-year survival between cohorts was similar (SherpaPak 92.9% vs ice 89.6%, p = 0.27). CONCLUSIONS: This subgroup analysis demonstrates that SherpaPak can be safely used to utilize extended criteria donors with low severe PGD rates.


Assuntos
Transplante de Coração , Doadores de Tecidos , Adulto , Humanos , Gelo , Coração , Sistema de Registros , Estudos Retrospectivos
8.
J Thorac Cardiovasc Surg ; 167(1): 231-240.e7, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-36100474

RESUMO

OBJECTIVE: Prior studies have examined the effect of blood type on heart transplantation (HTx) waitlist outcomes in cohorts through 2015. We aim to analyze the effect of blood type on contemporary waitlist outcomes with a new allocation system focus. METHODS: Adults listed for HTx between April 2015 and December 2020 were included. Survival to HTx and waitlist death/deterioration was compared between type O and non-type O candidates using competing risks regression. Donor/recipient ABO compatibility trends were further investigated. RESULTS: Candidates with blood type O (n = 7509) underwent HTx less frequently than candidates with blood type other than type O (n = 9699) (subhazard ratio [sHR], 0.56; 95% CI, 0.53-0.58) with higher rates of waitlist death/deterioration (sHR, 1.18; 95% CI, 1.04-1.34). Subgroup analyses demonstrated persistence of this trend under the new donor heart allocation system (HTx: sHR, 0.58; 95% CI, 0.54-0.62; death/clinical deterioration: sHR, 1.27; 95% CI, 1.02-1.60), especially among those listed at high status (1, 2, or 3) (HTx: sHR, 0.69; 95% CI, 0.63-0.75; death/deterioration: sHR, 1.61; 95% CI, 1.16-2.22). Among those listed at status 3, waitlist death/deterioration was modified by presence of a durable left ventricular assist device (left ventricular assist device: sHR, 1.57; 95% CI, 0.58-4.29; no left ventricular assist device: sHR, 3.79; 95% CI, 1.28-11.2). Type O donor heart allocation to secondary ABO candidates increased in the new system (14.5% vs 12.0%; P < .01); post-HTx survival remained comparable between recipients with blood type O and non-type O (log-rank P = .07). CONCLUSIONS: Further logistical considerations are warranted to minimize allocation inequity regarding blood type under the new allocation system.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Adulto , Humanos , Transplante de Coração/efeitos adversos , Doadores de Tecidos , Listas de Espera , Insuficiência Cardíaca/cirurgia , Estudos Retrospectivos
9.
ASAIO J ; 69(11): 993-1000, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37678260

RESUMO

Traditional ice storage has been the historic standard for preserving donor's hearts. However, this approach provides variability in cooling, increasing risks of freezing injury. To date, no preservation technology has been reported to improve survival after transplantation. The Paragonix SherpaPak Cardiac Transport System (SCTS) is a controlled hypothermic technology clinically used since 2018. Real-world evidence on clinical benefits of SCTS compared to conventional ice cold storage (ICS) was evaluated. Between October 2015 and January 2022, 569 US adults receiving donor hearts preserved and transported either in SCTS (n = 255) or ICS (n = 314) were analyzed from the Global Utilization And Registry Database for Improved heArt preservatioN (GUARDIAN-Heart) registry. Propensity matching and a subgroup analysis of >240 minutes ischemic time were performed to evaluate comparative outcomes. Overall, the SCTS cohort had significantly lower rates of severe primary graft dysfunction (PGD) ( p = 0.03). When propensity matched, SCTS had improving 1-year survival ( p = 0.10), significantly lower rates of severe PGD ( p = 0.011), and lower overall post-transplant MCS utilization ( p = 0.098). For patients with ischemic times >4 hours, the SCTS cohort had reduced post-transplant MCS utilization ( p = 0.01), reduced incidence of severe PGD ( p = 0.005), and improved 30-day survival ( p = 0.02). A multivariate analysis of independent risk factors revealed that compared to SCTS, use of ice results in a 3.4-fold greater chance of severe PGD ( p = 0.014). Utilization of SCTS is associated with a trend toward increased post-transplant survival and significantly lower severe PGD and MCS utilization. These findings fundamentally challenge the decades-long status quo of transporting donor hearts using ice.


Assuntos
Transplante de Coração , Doadores de Tecidos , Adulto , Humanos , Transplante de Coração/efeitos adversos , Transplante de Coração/métodos , Gelo , Coração , Incidência , Estudos Retrospectivos
10.
ASAIO J ; 69(12): e520-e522, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37499690

RESUMO

Primary graft dysfunction is a feared complication and cause of mortality post-heart transplant. Primary graft dysfunction may require mechanical circulatory support, such as venoarterial extracorporeal membrane oxygenation, which carries its own risk for complications. We developed a new mechanical circulatory support method for patients who underwent heart transplant bridged with Impella 5.5, which was then placed into the donor heart. Among 12 heart transplants, four required Impella 5.5 support. The average age was 55.8 years. The mean duration for postoperative mechanical circulatory support was 3.8 days, ranging from 2 to 5 days. No patients developed severe right ventricular dysfunction. In our limited study, complications and mortality associated with the replanted Impella 5.5 were both 0%.


Assuntos
Transplante de Coração , Coração Auxiliar , Disfunção Primária do Enxerto , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Doadores de Tecidos , Hemodinâmica , Resultado do Tratamento , Choque Cardiogênico
11.
J Am Heart Assoc ; 12(13): e029086, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37382139

RESUMO

Background Severe cardiac cachexia or malnutrition are commonly considered relative contraindications to left ventricular assist device (LVAD) implantation, but post-LVAD prognosis for patients with cachexia is uncertain. Methods and Results Intermacs (Interagency Registry for Mechanically Assisted Circulatory Support) 2006 to 2017 was queried for the preimplantation variable cachexia/malnutrition. Cox proportional hazards modeling examined the relationship between cachexia and LVAD outcomes. Of 20 332 primary LVAD recipients with available data, 516 (2.54%) were reported to have baseline cachexia and had higher risk baseline characteristics. Cachexia was associated with higher mortality during LVAD support (unadjusted hazard ratio [HR], 1.36 [95% CI, 1.18-1.56]; P<0.0001), persisting after adjustment for baseline characteristics (adjusted HR, 1.23 [95% CI, 1.0-1.42]; P=0.005). Mean weight change at 12 months was +3.9±9.4 kg. Across the cohort, weight gain ≥5% during the first 3 months of LVAD support was associated with lower mortality (unadjusted HR, 0.90 [95% CI, 0.84-0.98]; P=0.012; adjusted HR, 0.89 [95% CI, 0.82-0.97]; P=0.006). Conclusions The proportion of LVAD recipients recognized to have cachexia preimplantation was low at 2.5%. Recognized cachexia was independently associated with higher mortality during LVAD support. Early weight gain ≥5% was independently associated with lower mortality during subsequent LVAD support.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Desnutrição , Humanos , Coração Auxiliar/efeitos adversos , Caquexia/etiologia , Sistema de Registros , Resultado do Tratamento , Estudos Retrospectivos
12.
ASAIO J ; 69(9): 863-870, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37159442

RESUMO

Although the transplant outcomes of centers are heavily monitored and compared, with a particular link between posttransplant outcomes and center volume demonstrated, little data exist comparing waitlist outcomes. Here, we explored waitlist outcomes by transplant center volume. We performed a retrospective analysis of adults listed for primary heart transplantation (HTx) from 2008 to 2018 using the United Network for Organ Sharing database. Transplant centers were split into low (<10 HTx/year), medium (10-30 HTx/year), and high (>30 HTx/year) volume, and waitlist outcomes were compared. Of the 35,190 patients included in our study, 23,726 (67.4%) underwent HTx, 4,915 (14.0%) died or deteriorated before receiving HTx, 1,356 (3.9%) were delisted due to recovery, and 1,336 (3.8%) underwent left ventricular assist device (LVAD) implantation. High-volume centers had higher rates of survival to transplant (71.3% vs. 60.6% for low-volume centers and 64.9% for medium-volume centers), and low rates of death or deterioration (12.6% vs. 14.6% for low-volume centers and 15.1% for medium-volume centers). Listing at a low-volume center was independently associated with death or delisting before HTx (HR 1.18, p = 0.007), whereas listing at a high-volume center (HR 0.86; p < 0.001) and prelisting LVAD (HR 0.67, p < 0.001) were protective. Death or delisting before HTx was lowest for patients listed in higher volume centers.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Adulto , Humanos , Estudos Retrospectivos , Listas de Espera , Bases de Dados Factuais , Insuficiência Cardíaca/cirurgia , Resultado do Tratamento
13.
J Cardiothorac Vasc Anesth ; 37(8): 1418-1423, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37173169

RESUMO

OBJECTIVES: To evaluate the association of pulmonary artery diameter and pulmonary artery- to-aorta diameter ratio (PA/Ao) with right ventricular failure and mortality within 1 year after left ventricular assist device implantation. DESIGN: This was a retrospective observational study between March 2013 and July 2019. SETTING: The study was conducted at a single, quaternary-care academic center. PARTICIPANTS: Adults (≥18 years old) receiving a durable left ventricular assist device (LVAD). Inclusion if (1) a chest computed tomography scan was performed within 30 days before the LVAD and (2) a right and left heart catheterization was completed within 30 days before the LVAD. INTERVENTIONS: A left ventricular assist device was used for intervention. MEASUREMENTS AND MAIN RESULTS: A total of 176 patients were included in this study. Median PA diameter and PA/Ao ratio were significantly greater in the severe right ventricular failure (RVF) group (p = 0.001, p < 0.001, respectively). Receiver operating characteristic analysis revealed PA/Ao and RVF as predictors for mortality (area under the curve = 0.725 and 0.933, respectively). Logistic regression analysis-predicted probability gave a PA/Ao ratio cutoff point of 1.04 (p < 0.001). Survival probability was significantly worse in patients with a PA/Ao ratio ≥1.04 (p = 0.005). CONCLUSIONS: The PA/Ao ratio is an easily measurable noninvasive indicator that can predict RVF and 1-year mortality after LVAD implantation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Adulto , Humanos , Adolescente , Artéria Pulmonar/diagnóstico por imagem , Fatores de Risco , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Estudos Retrospectivos , Aorta
14.
ASAIO J ; 69(7): 665-670, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37084326

RESUMO

To improve healthcare access, the US government implemented the Affordable Care Act (ACA) in 2014. Previous studies investigating its impact on healthcare inequities showed significant improvement in Black transplant recipient outcomes. Our objective is to determine the ACA's impact on Black heart transplant (HTx) recipients. Using the United Network for Organ Sharing database, we analyzed 3,462 Black HTx recipients pre- and post-ACA (January 2009 to December 2012, and January 2014 to December 2017). Black recipient numbers and rates of overall HTx, insurance effects on survival, geographic changes in HTx, and post-HTx survival were compared pre- and post-ACA. Black recipients increased from 1,046 (15.3%) to 2,056 (22.2%) post-ACA ( p < 0.001). Three year survival increased among Black recipients (85.8-91.9%, p = 0.01; 79.4-87.7%, p < 0.01; 78.3-84.6%, p < 0.01). Affordable Care Act implementation was protective for survival (hazard ratio [HR] = 0.64 [95% confidence interval [CI], 0.51-0.81], p < 0.01). Publicly insured patient survival increased post-ACA to match that of privately insured (87.3-91.8%, p = 0.001). United Network for Organ Sharing (UNOS) Regions 2, 8, and 11 experienced improved survival post-ACA ( p = 0.047, p = 0.02, and p < 0.01, respectively). The post-ACA era showed improved HTx access and survival in Black recipients, indicating that national medical policy may play a strong role in eliminating racial disparities. Further attention is required to improve inequities in medical care. http://links.lww.com/ASAIO/B2.


Assuntos
Transplante de Coração , Patient Protection and Affordable Care Act , Estados Unidos/epidemiologia , Humanos , Modelos de Riscos Proporcionais , Acessibilidade aos Serviços de Saúde
16.
J Vasc Surg Cases Innov Tech ; 9(2): 101121, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36970134

RESUMO

Objective: Extracorporeal membrane oxygenation (ECMO) support for patients with cardiac or respiratory failure has been increasingly used by advanced critical care practitioners. The thromboembolic complications of ECMO have been extensively discussed and researched; however, research and discussion on the development, risks, and management of cannulae-associated fibrin sheaths are lacking. Methods: Institutional review board approval was not required. We have presented three cases detailing the identification and individualized management of ECMO-associated fibrin sheaths at our institution. The three patients provided written informed consent for the report of their case details and imaging studies. Results: Of our three patients with ECMO-associated fibrin sheaths, two were managed successfully with anticoagulation alone. One could not receive anticoagulation therapy and underwent inferior vena cava filter placement. Conclusions: Fibrin sheath formation around indwelling ECMO cannulae is an unresearched complication of ECMO cannulation. We would recommend an individualized approach to the management of these fibrin sheaths and have provided three examples of successful management.

18.
ASAIO J ; 69(5): 475-482, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36724196

RESUMO

Transcatheter aortic valve replacement (TAVR) has become the preferred treatment for severe aortic stenosis. Previous studies compare clinical outcomes of leading TAVR valves, but there is no evidence of cost-utility comparison, leaving a clinical information gap when selecting valves. Here we share a cost-utility analysis comparing the Sapien 3 (S3) (Edwards Lifesciences, Irvine, CA) and CoreValve Evolut R (ER) (Medtronic, Dublin, IR) across five clinical endpoints. Utility scores from patient surveys and clinical outcomes from the literature were used to estimate quality-adjusted life years (QALYs) associated with successful procedure and postoperative complications for S3 and ER. A decision tree was constructed with rollback analysis to highlight the more cost-effective strategy. An incremental cost-utility ratio (ICUR) analysis was performed with a willingness to pay at $50,000. Deterministic and probabilistic sensitivity analyses were performed to validate robustness of results and account for uncertainty. S3 was found to be more costly ($68,377 vs. $66,072), but more effective (1.87 vs . 1.66) compared with ER. An ICUR of 11,288.12 favored S3, making it the more cost-effective option with a moderate confidence of 73.68% in Monte Carlo analysis. Cost-utility analysis can be used to aid in healthcare economics decision-making when selecting between comparable technologies used for TAVR procedures.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Valva Aórtica/cirurgia , Desenho de Prótese
19.
J Card Fail ; 29(3): 290-303, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36513273

RESUMO

INTRODUCTION: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is a prevailing option for the management of severe early graft dysfunction. This systematic review and individual patient data (IPD) meta-analysis aims to evaluate (1) mortality, (2) rates of major complications, (3) prognostic factors, and (4) the effect of different VA-ECMO strategies on outcomes in adult heart transplant (HT) recipients supported with VA-ECMO. METHODS AND RESULTS: We conducted a systematic search and included studies of adults (≥18 years) who received VA-ECMO during their index hospitalization after HT and reported on mortality at any timepoint. We pooled data using random effects models. To identify prognostic factors, we analysed IPD using mixed effects logistic regression. We assessed the certainty in the evidence using the GRADE framework. We included 49 observational studies of 1477 patients who received VA-ECMO after HT, of which 15 studies provided IPD for 448 patients. There were no differences in mortality estimates between IPD and non-IPD studies. The short-term (30-day/in-hospital) mortality estimate was 33% (moderate certainty, 95% confidence interval [CI] 28%-39%) and 1-year mortality estimate 50% (moderate certainty, 95% CI 43%-57%). Recipient age (odds ratio 1.02, 95% CI 1.01-1.04) and prior sternotomy (OR 1.57, 95% CI 0.99-2.49) are associated with increased short-term mortality. There is low certainty evidence that early intraoperative cannulation and peripheral cannulation reduce the risk of short-term death. CONCLUSIONS: One-third of patients who receive VA-ECMO for early graft dysfunction do not survive 30 days or to hospital discharge, and one-half do not survive to 1 year after HT. Improving outcomes will require ongoing research focused on optimizing VA-ECMO strategies and care in the first year after HT.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Transplante de Coração , Adulto , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Transplante de Coração/efeitos adversos , Mortalidade Hospitalar , Alta do Paciente , Estudos Retrospectivos
20.
J Crit Care ; 73: 154216, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36434833

RESUMO

One common but not well-understood phenomenon of temporary mechanical circulatory support (MCS) use is thrombocytopenia. This clinical issue increases the risk of bleeding and the need for platelet transfusion. Additionally, heparin-induced thrombocytopenia must be considered as part of the differential diagnosis, which complicates patient management. In what follows, we analyze the degree and relative rate of platelet count drop with various temporary MCS strategies - Impella 5.5; Veno-venous Extracorporeal Membrane Oxygenation (VV ECMO); Veno-arterial ECMO (VA ECMO); Intra-aortic Balloon Pump (IABP) and Centrimag Biventricular Assist Device (BIVAD). A total of 337 cohort was investigated. 77 was included for analysis after strict exclusion criteria were utilized (platelet transfusions, bleeding complications, etc.). Repeated measure mixed effect and linear regression models were used to assess the percent platelet drop on implantation of MCS and recovery after explantation of MCS. A statistically significant mean percent drop occurred in MCS types - VA ECMO(-69.6%, p < 0.001), VV ECMO(-40.9%, p < 0.001), Impella 5.5(-20.9%, p = 0.01) and IABP(-28.3%, p = 0.01), except Centrimag BIVAD(-6.5%, p = 0.61). Platelet recovery to or above baseline occurred in VA ECMO(+107.0%, p = 0.42), Impella 5.5(+117.2%, p = 0.28), IABP(+108.3%, p = 0.37), VV-ECMO(163.3%, p = 0.01*) and Centrimag BIVAD(+100.1%, p = 0.99). These results show that the degree of thrombocytopenia depends on MCS device type and is reversible.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Trombocitopenia , Humanos , Coração Auxiliar/efeitos adversos , Balão Intra-Aórtico/efeitos adversos , Balão Intra-Aórtico/métodos , Oxigenação por Membrana Extracorpórea/métodos , Trombocitopenia/terapia , Choque Cardiogênico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...