Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
J Arrhythm ; 40(3): 560-577, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38939795

RESUMO

Background: Remote monitoring (RM) of cardiac implantable electrical devices (CIEDs) can detect various events early. However, the diagnostic ability of CIEDs has not been sufficient, especially for lead failure. The first notification of lead failure was almost noise events, which were detected as arrhythmia by the CIED. A human must analyze the intracardiac electrogram to accurately detect lead failure. However, the number of arrhythmic events is too large for human analysis. Artificial intelligence (AI) seems to be helpful in the early and accurate detection of lead failure before human analysis. Objective: To test whether a neural network can be trained to precisely identify noise events in the intracardiac electrogram of RM data. Methods: We analyzed 21 918 RM data consisting of 12 925 and 1884 Medtronic and Boston Scientific data, respectively. Among these, 153 and 52 Medtronic and Boston Scientific data, respectively, were diagnosed as noise events by human analysis. In Medtronic, 306 events, including 153 noise events and randomly selected 153 out of 12 692 nonnoise events, were analyzed in a five-fold cross-validation with a convolutional neural network. The Boston Scientific data were analyzed similarly. Results: The precision rate, recall rate, F1 score, accuracy rate, and the area under the curve were 85.8 ± 4.0%, 91.6 ± 6.7%, 88.4 ± 2.0%, 88.0 ± 2.0%, and 0.958 ± 0.021 in Medtronic and 88.4 ± 12.8%, 81.0 ± 9.3%, 84.1 ± 8.3%, 84.2 ± 8.3% and 0.928 ± 0.041 in Boston Scientific. Five-fold cross-validation with a weighted loss function could increase the recall rate. Conclusions: AI can accurately detect noise events. AI analysis may be helpful for detecting lead failure events early and accurately.

2.
Heart Rhythm ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710349

RESUMO

BACKGROUND: Several signs of malignant early repolarizations have been proposed in patients with early repolarization syndrome (ERS). However, reports have challenged the efficacy of these signs in predicting future ventricular fibrillation (VF) in patients with ERS. OBJECTIVE: This study aimed to assess the predictive value of various electrocardiogram (ECG) markers for future VF events in patients with ERS. METHODS: We retrospectively evaluated the clinical characteristics of 44 patients with ERS to identify risk factors for VF during follow-up. RESULTS: After the initial event, 16 patients experienced VF (VF group), whereas 28 did not (non-VF group). The VF group had a longer QRS interval, more fragmented QRS (fQRS), and a higher T/R voltage ratio than the non-VF group. Wide J waves were more prevalent in the VF group; however, other J-wave markers did not differ between the groups. Positive late potentials recorded on signal-averaged ECGs were more frequent in the VF group. Whereas none of the patients showed spontaneous Brugada syndrome on ECG, the VF group frequently exhibited pilsicainide-induced ST-segment elevation. These ECG markers were significantly associated with the occurrence of VF during follow-up. Patients with multiple ECG factors, including QRS abnormalities (wide QRS or fQRS), wide J waves, and a high T/R ratio, had a worse prognosis than patients without multiple factors, effectively stratifying patient risk. CONCLUSION: The occurrence of VF in patients with ERS may be associated with conduction abnormalities such as QRS widening, fQRS, high T/R ratio, positive late potentials, and pilsicainide test results. Therefore, ECG factors could be useful in identifying high-risk patients.

4.
Heart Rhythm ; 21(5): 562-570, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38242221

RESUMO

BACKGROUND: Early repolarization syndrome (ERS) is an idiopathic ventricular fibrillation (VF) associated with inferolateral J waves. While electrical storm (ES) in ERS is not rare, their characteristics and risk factors are not fully understood. OBJECTIVE: This study aimed to clarify the significance of ES in ERS. METHODS: We evaluated 44 patients with ERS who experienced VF/sudden cardiac death or arrhythmic syncope. We assessed clinical characteristics to identify the risk factors for ES. RESULTS: In total, 13 patients (30%) experienced ES (ES group). Of these, 11 patients (85%) experienced ES during the acute phase of initial VF episodes and 2 patients (2%) experienced ES during follow-up. VF associated with ES occurred during therapeutic hypothermia in 6 of 13 patients (46%). The J-wave voltage during therapeutic hypothermia was higher in the ES group than that in the patients without ES. Isoproterenol was used in 5 patients (38%), which decreased J-wave voltage and relieved ES. Among the clinical markers, shorter QT and QTp intervals (the interval from QRS onset to the peak of T wave), pilsicainide-induced ST elevation, and high scores on the Shanghai Score System were associated with ES. Although pilsicainide induced ST elevation in 6 of 34 patients (18%), spontaneous Brugada electrocardiographic patterns did not appear to be associated with VF. Therapeutic hypothermia was also a risk factor for acute phase ES. CONCLUSION: Patients with ERS in the ES group frequently had short QT and QTp intervals, pilsicainide-induced ST elevations, and high Shanghai Score System scores. Therapeutic hypothermia was also associated with acute phase ES.


Assuntos
Eletrocardiografia , Fibrilação Ventricular , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia , Fatores de Risco , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Estudos Retrospectivos , Sistema de Condução Cardíaco/fisiopatologia , Seguimentos , Adulto , Idoso , Síndrome
5.
J Cardiovasc Electrophysiol ; 35(2): 307-316, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38105352

RESUMO

INTRODUCTION: Electrical storm (ES) of ventricular tachyarrhythmias (VTAs) is an important cause of sudden death in patients with cardiac sarcoidosis (CS). VTAs in CS are associated with myocardial scarring and inflammation. However, little is known about the risk factors of ES in patients with CS and VTAs. The objective of this study is to clarify the characteristics and risk factors for the development of ES in patients with CS. METHODS: The study population included consecutive 52 patients with CS and sustained VTA. Twenty-five out of 52 patients experienced ES. We evaluated clinical characteristics, imaging modalities, and electrocardiogram (ECG) parameters to determine the risk factors associated with ES. RESULTS: Half of the patients experienced VTAs as the initial symptom of sarcoidosis, and eight patients had ES as the initial VTA episode. There were no differences in cardiac imaging abnormalities between patients with and without ES. Among ECG markers, significant QRS fragmentation (odds ratio [OR]: 7.9, p = .01) and epsilon waves (OR: 12.24, p = .02) were associated with ES. Among the ventricular tachycardia (VT) characteristics, multiple morphologies of monomorphic VTs (OR: 10.9, p < .01), short VT cycle lengths (OR: 12.5, p < .01), and polymorphic VT (OR: 13.5, p < .01) were associated with ES. Bidirectional VTs were detected in 10 patients with ES and one patient without ES. Immunosuppressive therapy relieved ES in some patients. CONCLUSIONS: ES was common in patients with CS and VTAs. Significant depolarization abnormalities that appeared as QRS fragmentation, epsilon waves, and specific VT characteristics were associated with ES.


Assuntos
Miocardite , Sarcoidose , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Sarcoidose/complicações , Sarcoidose/diagnóstico , Fatores de Risco , Eletrocardiografia , Miocardite/complicações
6.
Heart Rhythm O2 ; 4(10): 641-649, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37936673

RESUMO

Background: Syncope is a significant prognostic factor in patients with Brugada syndrome (BrS). However, the risk of ventricular arrhythmia in patients with nonarrhythmic loss of consciousness (LOC) is similar to that in asymptomatic patients. LOC events after implantable cardioverter-defibrillator (ICD) implantation may provide insights into underlying causes of the initial LOC episode. Objective: The purpose of this study was to examine LOC characteristics following ICD implantation. Methods: We retrospectively analyzed 112 patients with BrS (mean age 47 years; 111 men) who were treated with an ICD. The patients were classified into 3 groups based on symptoms at implantation: asymptomatic (35 patients); LOC (46 patients); and ventricular tachyarrhythmia (VTA) (31 patients). We evaluated the incidence and cause of LOC during long-term follow-up after ICD implantation. Results: During mean follow-up of 12.2 years, 41 patients (37%) experienced LOC after ICD implantation. Arrhythmic LOC occurred in 5 asymptomatic patients, 14 LOC patients, and 16 patients with VTA. Nonarrhythmic LOC, similar to the initial episode, occurred after ICD implantation in 6 patients with prior LOC (2 with neurally mediated syncope and 4 with epilepsy). Most epileptic patients experienced LOC during rest or sleeping, and did not show an abnormal encephalogram during initial evaluation of the LOC episodes. Conclusion: After ICD implantation, 13% of patients had nonarrhythmic LOC similar to the initial episode. Accurate classification of LOC based on a detailed medical history is important for risk stratification, although distinguishing arrhythmic LOC from epilepsy-related LOC episodes can be challenging depending on the circumstances and characteristics of the LOC event.

8.
Heart Rhythm ; 20(12): 1729-1736, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37634559

RESUMO

BACKGROUND: J waves in the inferior or lateral leads are characteristic electrocardiographic (ECG) changes in patients with early repolarization syndrome (ERS). However, the presence of J waves in the left posterior region has not yet been evaluated. OBJECTIVE: The purpose of this study was to clarify the significance of J waves in the posterior left ventricle using leads V7-V9 and a body surface mapping (BSM) system. METHODS: Forty patients diagnosed with ERS were included. All patients exhibited J waves in either the contiguous inferior, lateral, or posterior leads. We evaluated the incidence of J waves in the inferolateral and posterior leads using a 15-lead ECG with synthesized V7-V9 and an 87-lead BSM. Additionally, we assessed the arrhythmogenicity of the posterior regions based on the morphology of the premature ventricular complexes (PVCs) associated with ventricular fibrillation (VF). RESULTS: J waves were observed in the lateral, inferior, and posterior leads of 26 (65%), 31 (78%), and 39 (97%) patients, respectively. J waves were found only in the posterior leads of 5 patients. BSM was evaluated in 9 patients, all of whom exhibited a positive area on the posterior region. PVCs associated with VF were recorded in 5 patients. Among patients with inferolateral and posterior J waves, all except 1 patient who displayed left bundle branch block morphology showed PVCs originating from the posterior left ventricular region. CONCLUSION: Posterior J waves are common in ERS patients. This abnormality can be detected using leads V7-V9 and the BSM system and may be associated with arrhythmogenesis.


Assuntos
Síndrome de Brugada , Complexos Ventriculares Prematuros , Humanos , Eletrocardiografia , Fibrilação Ventricular , Ventrículos do Coração/diagnóstico por imagem , Complexos Ventriculares Prematuros/complicações
9.
Circ Rep ; 5(7): 298-305, 2023 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-37431518

RESUMO

Background: Various types of arrhythmia are observed in patients with cardiac amyloidosis, but the prevalence of arrhythmia has not been fully investigated. This study investigated the prevalence and treatment of arrhythmias in patients with cardiac amyloidosis before the introduction of new agents for amyloidosis, such as tafamidis. Methods and Results: Of 53 patients who were histologically diagnosed with cardiac amyloidosis at 10 centers in western Japan between 2009 and 2021, 43 who were diagnosed on the basis of immunohistochemical staining were evaluated in this study. Of these 43 patients, 13 had immunoglobulin light-chain (AL) amyloidosis and 30 had transthyretin (ATTR) amyloidosis; further, 27 had atrial tachyarrhythmia, 13 had ventricular tachyarrhythmia, and 17 had bradyarrhythmia. Atrial fibrillation (AF) was the most common arrhythmia in patients with cardiac amyloidosis (n=24; 55.8%), especially among those with ATTR amyloidosis (70.0% of ATTR vs. 23.1% of AL). Eleven (25.6%) patients were treated with a cardiac implantable device. All 3 patients with pacemakers were alive at the last follow-up (median 76.7 months; interquartile range [IQR] 4.8-146.4 months). Of the 8 patients who underwent AF ablation, there was no recurrence in 6 (75%) after a median of 39.3 months (IQR 19.8-59.3 months). Conclusions: The prevalence of various arrhythmias was high in patients with cardiac amyloidosis. AF occurred most frequently in patients with cardiac amyloidosis, especially among patients with ATTR.

10.
J Cardiovasc Dev Dis ; 10(5)2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37233160

RESUMO

BACKGROUND: Patent foramen ovale (PFO) is associated with various diseases such as cryptogenic stroke, migraine, and platypnea-orthodeoxia syndrome. This study aimed to evaluate the diagnostic performance of cardiac computed tomography (CT) for PFO detection. MATERIALS AND METHODS: Consecutive patients diagnosed with atrial fibrillation and who underwent catheter ablation with pre-procedural cardiac CT and transesophageal echocardiography (TEE) were enrolled in this study. The presence of PFO was defined as (1) the confirmation of PFO using TEE and/or (2) the catheter crossing the interatrial septum (IAS) into the left atrium during ablation. CT findings indicative of PFO included (1) the presence of a channel-like appearance (CLA) on the IAS and (2) a CLA with a contrast jet flow from the left atrium to the right atrium. The diagnostic performance of both a CLA alone and a CLA with a jet flow was evaluated for PFO detection. RESULTS: Altogether, 151 patients were analyzed in the study (mean age, 68 years; men, 62%). Twenty-nine patients (19%) had PFO confirmed by TEE and/or catheterization. The diagnostic performance of a CLA alone was as follows: sensitivity, 72.4%; specificity, 79.5%; positive predictive value (PPV), 45.7%; negative predictive value (NPV), 92.4%. The diagnostic performance of a CLA with a jet flow was as follows: sensitivity, 65.5%; specificity, 98.4%; PPV, 90.5%; NPV, 92.3%. The diagnostic performance of a CLA with a jet flow was statistically superior to that of a CLA alone (p = 0.045), and the C-statistics were 0.76 and 0.82, respectively. CONCLUSION: A CLA with a contrast jet flow in cardiac CT has a high PPV for PFO detection, and its diagnostic performance is superior to that of a CLA alone.

11.
J Am Heart Assoc ; 12(10): e028706, 2023 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-37158059

RESUMO

Background The appearance of complete right bundle-branch block (CRBBB) in Brugada syndrome (BrS) is associated with an increased risk of ventricular fibrillation. The pathophysiological mechanism of CRBBB in patients with BrS has not been well established. We aimed to clarify the significance of a conduction delay zone associated with arrhythmias on CRBBB using body surface mapping in patients with BrS. Methods and Results Body surface mapping was recorded in 11 patients with BrS and 8 control patients both with CRBBB. CRBBB in control patients was transiently exhibited by unintentional catheter manipulation (proximal RBBB). Ventricular activation time maps were constructed for both of the groups. We divided the anterior chest into 4 areas (inferolateral right ventricle [RV], RV outflow tract [RVOT], intraventricular septum, and left ventricle) and compared activation patterns between the 2 groups. Excitation propagated to the RV from the left ventricle through the intraventricular septum with activation delay in the entire RV in the control group (proximal RBBB pattern). In 7 patients with BrS, excitation propagated from the inferolateral RV to the RVOT with significant regional activation delay. The remaining 4 patients with BrS showed a proximal RBBB pattern with the RVOT activation delay. The ventricular activation time in the inferolateral RV was significantly shorter in patients with BrS without a proximal RBBB pattern than in control patients. Conclusions The CRBBB morphology in patients with BrS consisted of 2 mechanisms: (1) significantly delayed conduction in the RVOT and (2) proximal RBBB with RVOT conduction delay. Significant RVOT conduction delay without proximal RBBB resulted in CRBBB morphology in patients with BrS.


Assuntos
Síndrome de Brugada , Humanos , Ventrículos do Coração/diagnóstico por imagem , Bloqueio de Ramo , Eletrocardiografia , Arritmias Cardíacas
12.
Can J Cardiol ; 39(7): 912-921, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36918097

RESUMO

BACKGROUND: Substrate mapping-based identification of all ventricular tachycardia (VT) circuits (diastolic activation), including partial and complete diastolic circuits in clinical and nonclinical VT, could be beneficial in guiding VT ablation to prevent VT recurrence. The utility of extrasystole induced late potentials has not been compared with late potentials in sinus rhythm (SR) and right ventricular pacing (RVp). METHODS: Intraoperative simultaneous panoramic endocardial mapping of 21 VTs in 16 ischemic heart disease patients was performed with the use of a 112-bipole endocardial balloon. The decrement of near-field electrogram later than surface QRS during extrasystole (eLP) was studied. RESULTS: Patients had a mean age of 52 ± 9 years and were predominantly (75%) male. The mean sensitivity of eLP (0.75 [95% confidence interval [CI] 0.72-0.78]) to detect VT circuits was better than SR (0.33 [0.30-0.36]; P < 0.001) and RVp (0.36 [0.33-0.39]; P < 0.001) without significant differences in specificity, eLP (0.77 [0.74-0.81], SR (0.82 [0.80-0.84]; P = 0.23), and RVp (0.81 [0.78-0.83]; P = 0.11). Both negative (NPV) and positivie (PPV) predictive values were significantly better for eLP mapping. The mean NPV was 0.77 (95% CI 0.74-0.81), 0.57 (0.55-0.59), and 0.58 (0.55-0.61) for eLP, SR, and RVp, respectively (P < 0.0001). PPV was 0.75 (95% CI 0.72-0.78), 0.63 (0.59-0.67), and 0.63 (0.59-0.67) for eLP, SR, and RVp, respectively (P < 0.001). Overall diagnostic performance (area under the receiver operating characteristic curve) was significantly better for eLP (0.85 [95% CI 0.80-0.90] compared with SR (0.63 [0.56-0.72]; P < 0.001) or RVp (0.61 [0.52-0.74]; P < 0.001). CONCLUSIONS: Evoked late potential mapping is a better tool to detect comprehensive diastolic circuits activated during VT, compared with eLP mapping in sinus rhythm or RV pacing.


Assuntos
Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Ventrículos do Coração , Isquemia Miocárdica/cirurgia , Complexos Cardíacos Prematuros/cirurgia , Ablação por Cateter/métodos
13.
Can J Cardiol ; 39(3): 236-245, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36565849

RESUMO

BACKGROUND: The implantable cardioverter-defibrillator (ICD) has been proven to improve survival in adults with congenital heart disease (ACHD), but it is associated with a high rate of complications. We aimed to quantify the incidence of early (≤ 3 months; ECs) and late (> 3 months; LCs) complications in ACHD patients implanted with an ICD and to identify their clinical predictors. METHODS: We retrospectively reviewed 207 patients who had ICD follow-up at Toronto General Hospital from 1996 to 2019. RESULTS: The most common diagnoses were tetralogy of Fallot (32.4%), dextro-transposition of the great arteries (17.9%), and congenital corrected transposition of the great arteries (13%). No intraprocedural complications were observed. Median follow-up was 3.4 years (IQR 0.1-23). 24 patients (12%) developed EC (4 hematomas, 20 lead dislodgements). A total of 56 LCs occurred (46% lead failure, 21% infection, 11% prophylactic lead extraction, 9% neurologic pain, 9% erosion, 4% other) with an incidence rate of LCs of 18% per 5 person-years. Anatomic complexity (odds ratio 2.9; P = 0.02) and cardiac resynchronization therapy defibrillator implant (odds ratio 2.5; P = 0.04) were associated with ECs. Survival rates free from LCs were 92%, 86%, and 65%, respectively, after 1, 5, and 10 years. Presence of legacy leads (hazard ratio 2.9; P = 0.006) and subpulmonary ejection fraction (5% increase, hazard ratio 1.35; P = 0.031) were associated with LCs. CONCLUSIONS: ACHD patients at risk of sudden cardiac death continue to benefit from newer device technology. However, these patients, particularly those with greater anatomic and device complexity, remain at increased risk of developing complications over their lifetime. Given the life expectancy of this population, careful consideration needs to be given when a device for primary prevention is being contemplated.


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Transposição dos Grandes Vasos , Humanos , Adulto , Desfibriladores Implantáveis/efeitos adversos , Incidência , Estudos Retrospectivos , Transposição dos Grandes Vasos/complicações , Cardiopatias Congênitas/cirurgia , Morte Súbita Cardíaca/prevenção & controle
15.
Circ J ; 86(8): 1312-1318, 2022 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-35768227

RESUMO

The 86thAnnual Scientific Meeting of the Japanese Circulation Society was held in a web-based format on March 11-13, 2022. In accordance with the internationalization policy of the JCS, the meeting was held with the Asian Pacific Society of Cardiology Congress 2022. The main theme was "Cardiology Spreading its Wings". The number of patients with heart failure and other cardiovascular diseases is increasing dramatically, and the fields dealt with by cardiovascular medicine are also greatly expanding. This conference was both intellectually satisfying and exciting for all participants, who numbered over 14,900. The meeting was completed with great success, and the enormous amount of cooperation and support from all involved was greatly appreciated.


Assuntos
Cardiologia , Doenças Cardiovasculares , Insuficiência Cardíaca , Animais , Humanos , Japão , Sociedades Médicas
17.
J Colloid Interface Sci ; 604: 61-79, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34265693

RESUMO

This study aimed to develop a highly selective extraction protocol for gold (AuIII) ions from electronic urban waste (EUW) using simple, low-cost Inorganic-organic mesoporous hybrid segregators. The unique features of mesoporous hybrid segregator architectures are of particular to ensure effective adsorption system in terms of selective and sensitive recovery of AuIII ions from EUW. The segregator platform featured 3D micrometric, mesocage double-serrated plant-leaf-like γ-Al2O3 sheets with hierarchy surfaces containing tri-modal mesopores interiorly and uniformly arranged toothed edges of ~20-40 and ~15 nm groove width and depth at the exterior surfaces, respectively. Rational incorporation of actively organic chelates into hierarchical γ-Al2O3 sheet platforms leads to the production of a couple of selective segregators 1 and 2 (namely, SC1 and SC2) for AuIII ions at specific conditions by applying batch and fixed-bed columnar techniques. The mesocage SC segregators offer a selective extraction approach of AuIII ions from mixed element contents released from a computer motherboard (CMB). Our finding indicated that the textural and hierarchal features of the mesocage SC segregators played key roles in the selective adsorption/recovery of AuIII ions at pH 2-2.5 with high capacity (136-141 mg/g range) and effective reusability ≫10 consecutive cycles. In general, the developed SCs could be utilized as a real extractor of AuIII recovery from spent CMBs.


Assuntos
Quelantes , Ouro , Adsorção , Membrana Celular
18.
CJC Open ; 3(5): 619-626, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34027366

RESUMO

BACKGROUND: Implantable cardioverter defibrillators (ICDs) are effective in preventing arrhythmic sudden cardiac death in patients with tetralogy of Fallot (TOF). Although ICD therapies for malignant ventricular arrhythmias can be life-saving, shocks could have deleterious consequences. Substrate-based ablation therapy has become the standard of care to prevent recurrent ICD shocks in patients with ischemic cardiomyopathy. However, the efficacy and safety of this invasive therapy in the prevention of recurrent ICD shocks in patients with TOF has not been well evaluated. METHODS: Records of a total of 47 consecutive TOF patients (mean age: 43.1 ± 13.2 years, male sex: n = 34 [72.3%]) who underwent ICD implantation for secondary prevention between 2000 and 2018 were reviewed. RESULTS: Twenty (42.6%) patients underwent invasive therapy (radiofrequency catheter ablation, n = 8; surgical ablation with pulmonary valve replacement, n = 12) before ICD implantation. Twenty-seven patients (57.4%) were managed noninvasively. During follow-up (median 80.5 [interquartile range, 28.5-131.0] months), 2 (10.0%) patients in the invasive group and 10 (37.0%) patients in the noninvasive group received appropriate ICD shocks (P = 0.036). Logistic regression analysis showed that invasive therapy was associated with a decreased risk of ICD shocks by 81.1% (odds ratio, 0.189; 95% confidence interval, 0.036-0.990; P = 0.049). Furthermore, invasive therapy was associated with decreased risk of the composite outcomes of ICD shock, death, cardiac transplantation, and hospital admission (odds ratio, 0.090; 95% confidence interval, 0.025-0.365; P = 0.013) compared with noninvasive therapy. CONCLUSIONS: Invasive substrate modification therapy was associated with a lower likelihood of ICD shocks and improvement of long-term outcomes in TOF patients.


CONTEXTE: Les défibrillateurs cardioverteurs implantables (DCI) sont efficaces pour prévenir la mort cardiaque subite provoquée par une arythmie chez les patients présentant une tétralogie de Fallot (TF). Bien que le traitement des arythmies ventriculaires malignes par DCI puisse sauver des vies, les chocs administrés peuvent avoir des conséquences délétères. L'ablation du substrat est devenue le traitement de référence pour prévenir l'administration à répétition de chocs par DCI chez les patients atteints d'une cardiomyopathie ischémique. L'efficacité et l'innocuité de ce traitement invasif pour prévenir l'administration de chocs répétés chez les patients présentant une TF n'ont toutefois pas été bien évaluées. MÉTHODOLOGIE: Nous avons examiné les cas consécutifs de 47 patients présentant une TF (âge moyen : 43,1 ± 13,2 ans; hommes : n = 34 [72,3 %]) ayant reçu un DCI en prévention secondaire entre 2000 et 2018. RÉSULTATS: Au total, 20 (42,6 %) patients ont subi un traitement invasif (ablation par cathéter par radiofréquence, n = 8; ablation chirurgicale et remplacement de la valve pulmonaire, n = 12) avant l'implantation d'un DCI. Vingt-sept patients (57,4 %) ont été pris en charge de façon non invasive. Au cours de la période de suivi (durée médiane de 80,5 [intervalle interquartile : 28,5 à 131,0] mois), 2 (10,0 %) patients du groupe ayant subi une intervention invasive et 10 (37,0 %) patients du groupe ayant subi une intervention non invasive ont reçu un choc approprié par DCI (p = 0,036). Les résultats de l'analyse par régression logistique montrent que le traitement invasif est associé à une réduction du risque de choc par DCI de 81,1 % (rapport des cotes : 0,189; intervalle de confiance à 95 % : de 0,036 à 0,990; p = 0,049). En outre, le traitement invasif est associé à une réduction du risque de survenue d'un des événements du paramètre d'évaluation composé, soit un choc administré par DCI, le décès, une transplantation cardiaque ou une hospitalisation (rapport des cotes : 0,090; intervalle de confiance à 95 % : de 0,025 à 0,365; p = 0,013) par rapport au traitement non invasif. CONCLUSIONS: La modification invasive du substrat a été associée à une probabilité plus faible de choc administré par DCI et à une amélioration des résultats à long terme chez les patients présentant une TF.

19.
Heart Rhythm ; 18(6): 962-969, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33516947

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) is necessary because of system infection, lead malfunction, or system upgrade. Patients with severe left ventricular dysfunction (SLVD) undergoing TLE may be at a higher risk because hemodynamic parameters may change unfavorably during or after TLE; however, this has not yet been clarified. OBJECTIVE: The purpose of this study was to examine whether patients with SLVD undergoing TLE have higher mortality. METHODS: All patients who underwent TLE were stratified as follows: patients with ejection fraction ≤ 35% (SLVD group) and those with ejection fraction > 35% (non-SLVD group). RESULTS: We assessed the data of 200 patients [SLVD group, 36 (18%); non-SLVD group, 164 (82%)]). Brain natriuretic peptide level and cardiac resynchronization therapy rate were higher in the SLVD group than in the non-SLVD group. There were no significant between-group differences in major complications and clinical success rates. Patients with SLVD were more likely to require additional hemodynamic support, such as catecholamine infusion, temporary atrium-ventricle sequential pacing, and temporary cardiac resynchronization therapy pacing (27.8% vs 1.2%; P < .001). The survival rate was not significantly different between the groups at 30 days and 1 year after TLE (SLVD vs non-SLVD: 30 days: 97.2% vs 99.4%; P = .215; 1 year: 80.6% vs 91.5%; P = .053). Multivariate Cox regression analysis revealed log brain natriuretic peptide and serum hemoglobin levels as predictors for 1-year mortality. CONCLUSION: The prognosis after TLE was comparable between patients with and without SLVD. However, additional hemodynamic support was often necessary for patients with SLVD.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Catecolaminas/administração & dosagem , Remoção de Dispositivo/efeitos adversos , Hemodinâmica/fisiologia , Complicações Pós-Operatórias/etiologia , Disfunção Ventricular Esquerda/etiologia , Idoso , Feminino , Seguimentos , Ventrículos do Coração , Humanos , Infusões Intravenosas , Japão/epidemiologia , Masculino , Complicações Pós-Operatórias/tratamento farmacológico , Complicações Pós-Operatórias/mortalidade , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento , Disfunção Ventricular Esquerda/tratamento farmacológico , Disfunção Ventricular Esquerda/fisiopatologia
20.
Can J Cardiol ; 37(3): 407-416, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32522524

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) have been proven to prevent sudden cardiac death in adult congenital heart disease (ACHD) patients. Although the left side is chosen by default, implantation from the right side is often required. However, little is known about the efficacy and safety of right-sided ICDs in ACHD patients. METHODS: In this study we reviewed a total of 191 ACHD patients undergoing ICD/cardioverter resynchronisation therapy-defibrillator (CRT-D) implantation at our hospital between 2001 and 2019 (134 men and 57 women; age [mean ± standard deviation], 41.5 ± 14.8 years). RESULTS: Twenty-seven patients (14.1%) had right-sided devices. The most common causes of right-sided implantation were persistent left superior vena cava and vein occlusion (37.0%). Although procedure time (202.8 ± 60.5 minutes vs 143.8 ± 69.1 minutes, P = 0.008) was longer and the procedural success was lower (92.6% vs 99.4%, P = 0.008) for right-sided devices, no difference in R-wave and pacing threshold were noted. Among the 47 patients (24.6%) who underwent defibrillation threshold testing (DFT), no difference in DFT was observed (25.2 ± 5.3 J vs 23.8 ± 4.1 J, P = 0.460). During the median follow-up of 42.4 months, appropriate ICD therapy was observed in 5 (18.5%) and 30 (18.3%) patients for right- and left-sided ICDs/CRTDs, respectively (P = 0.978). No significant difference was seen in complications between them. CONCLUSIONS: Implantation of an ICD on the right side is technically challenging, but it is feasible as an alternative approach for ACHD patients with contraindications to left-sided device implantation.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Terapia de Ressincronização Cardíaca , Morte Súbita Cardíaca , Desfibriladores Implantáveis/estatística & dados numéricos , Cardiopatias Congênitas , Ventrículos do Coração/cirurgia , Implantação de Prótese , Adulto , Canadá/epidemiologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Feminino , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Implantação de Prótese/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...