Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 310
Filtrar
1.
Appl Radiat Isot ; 109: 325-329, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26701660

RESUMO

A 4π(ß(+)+γ) integral counting method using 4πß-4πγ detector configuration composed of a large well type NaI(Tl) scintillation detector and stacked plastic scintillators positioned in the center of the well and coupled with a slender PMT was adopted for activity measurement of (68)Ge-(68)Ga. Several source preparation schemes were studied to reduce the activity loss due to volatility. The possible contribution of EC events were rejected with pulse-height discrimination. Owing to the high counting efficiencies in both channels and the multiplicity of photons and ß-particles emitted, the 4π(ß(+)+γ) integral counting system gives a count rate very nearly equal to the positron emission rate. The activity can be determined simply from this value divided by the positron emission branching ratio. The remaining overall inefficiency was evaluated by the EGS5 code.

2.
Appl Radiat Isot ; 109: 414-417, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26699676

RESUMO

We developed a 4πß-4πγ counter composed of a 4π plastic scintillation detector and a well-type Ge detector, employing digital coincidence counting and data storage in list-mode. In both of the ß- and γ-channels, the amplified pulses from a linear amplifier feed the input channel of the digitizer directly via delay circuits. A signal from the peak-hold of each channel is fed to a sliding scale ADC (14bits, 200MHz clock) after peak detection and converted into 13bit digital data, registered along with a time stamp and event channel allowing various data analysis to be implemented offline. When employing multiple gamma window settings, a weighted average of each apparent efficiency might be introduced to improve the efficiency functions. This idea was investigated along with reasonable estimates of the weighing factors, and activity measurements of (59)Fe using this system are presented.

3.
Appl Radiat Isot ; 87: 397-401, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24331856

RESUMO

In the use of photon detectors having sensitivity to ß-rays or internal conversion electrons (CEs), ß-γ and/or X-CE coincidence summing may arise. In particular, an n-type germanium detector has a thin dead layer and window, causing considerably higher sensitivity to ß-rays and/or CEs especially when sources are located at a small source-to-detector distance. In the present research, reduction of the photopeak area due to ß-γ or X-CE coincidence summing has been studied for three germanium detectors.

4.
Appl Radiat Isot ; 87: 183-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24373824

RESUMO

In order to clarify the γ-efficiency dependency of 4πß-γ efficiency functions, a series of 4πß-γ efficiency extrapolation measurements of a (134)Cs source were carried out for a wide variety of γ-geometries using a 4πß(PS)-4πγ detector configuration. As the source is situated in the plastic scintillator (PS) ß-detector, the γ-efficiency of the system can be readily changed by extracting the ß-detector from the well-hole in a series of stages. For data acquisition and analyses, a list-mode two-parameter data acquisition system was employed. The forms of the extrapolation curves were monitored with decreasing γ-geometry, eventually exhibiting a similar behavior to those obtained in a usual 4πß-γ coincidence counting system. The experimental results and considerations suggested that the γ-geometry dependency of the efficiency functions were due to summing effects in the γ-channel, and some qualitative remarks on the form of the extrapolation functions are given.

5.
Appl Radiat Isot ; 81: 261-7, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23660084

RESUMO

We measured 4π and 2π counting efficiencies for internal conversion electrons (ICEs), gross ß-particles and also ß-rays alone with various source conditions regarding absorber and backing foil thickness using e-X coincidence technique. Dominant differences regarding the penetration, attenuation and backscattering properties among ICEs and ß-rays were revealed. Although the abundance of internal conversion electrons of (137)Cs-(137)Ba is only 9.35%, 60% of gross counts may be attributed to ICEs in worse source conditions. This information will be useful for radionuclide metrology and for surface contamination monitoring.


Assuntos
Partículas beta , Radioisótopos de Césio/análise , Elétrons , Monitoramento de Radiação/instrumentação , Cinza Radioativa/análise , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
6.
Appl Radiat Isot ; 81: 353-5, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23562432

RESUMO

A simplified peak fitting technique for the analysis of the overlapped pulse-height spectra of (134)Cs and (137)Cs γ-rays obtained with a NaI(Tl) scintillation spectrometer was studied. In this analysis, nearly an upper half of 662 keV (137)Cs peak data was employed for fitting of the Gaussian peak using the least squares algorithm. Consistent results were obtained as compared with the reference value of test samples mixed with (134)Cs and (137)Cs standard solutions.


Assuntos
Radioisótopos de Césio/análise , Análise de Alimentos/instrumentação , Contaminação Radioativa de Alimentos/análise , Cinza Radioativa/análise , Contagem de Cintilação/instrumentação , Espectrometria gama/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Japão , Doses de Radiação , Iodeto de Sódio/efeitos da radiação
7.
Diabetologia ; 56(5): 1088-97, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23412604

RESUMO

AIMS/HYPOTHESIS: The small G-protein ras-related C3 botulinum toxin substrate 1 (RAC1) plays various roles in mammalian cells, such as in the regulation of cytoskeletal organisation, cell adhesion, migration and morphological changes. The present study examines the effects of RAC1 ablation on pancreatic beta cell function. METHODS: Isolated islets from pancreatic beta cell-specific Rac1-knockout (betaRac1(-/-)) mice and RAC1 knockdown INS-1 insulinoma cells treated with small interfering RNA were used to investigate insulin secretion and cytoskeletal organisation in pancreatic beta cells. RESULTS: BetaRac1(-/-) mice showed decreased glucose-stimulated insulin secretion, while there were no apparent differences in islet morphology. Isolated islets from the mice had blunted insulin secretion in response to high glucose levels. In RAC1 knockdown INS-1 cells, insulin secretion was also decreased in response to high glucose levels, consistent with the phenotype of betaRac1(-/-) mice. Even under high glucose levels, RAC1 knockdown INS-1 cells remained intact with F-actin, which inhibits the recruitment of the insulin granules, resulting in an inhibition of insulin secretion. CONCLUSIONS/INTERPRETATION: In RAC1-deficient pancreatic beta cells, F-actin acts as a barrier for insulin granules and reduces glucose-stimulated insulin secretion.


Assuntos
Citoesqueleto de Actina/metabolismo , Células Secretoras de Insulina/metabolismo , Insulina/metabolismo , Neuropeptídeos/metabolismo , Via Secretória , Proteínas rac1 de Ligação ao GTP/metabolismo , Animais , Linhagem Celular , Hiperglicemia/metabolismo , Secreção de Insulina , Células Secretoras de Insulina/citologia , Masculino , Camundongos , Camundongos Knockout , Neuropeptídeos/antagonistas & inibidores , Neuropeptídeos/genética , Pâncreas/citologia , Pâncreas/metabolismo , Perfusão , Interferência de RNA , RNA Mensageiro/metabolismo , RNA Interferente Pequeno , Ratos , Técnicas de Cultura de Tecidos , Proteínas rac1 de Ligação ao GTP/antagonistas & inibidores , Proteínas rac1 de Ligação ao GTP/genética
8.
Phys Rev Lett ; 109(2): 022501, 2012 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-23030155

RESUMO

The unbound excited states of the neutron drip-line isotope 24O have been investigated via the 24O(p,p')23O + n reaction in inverse kinematics at a beam energy of 62 MeV/nucleon. The decay energy spectrum of 24O* was reconstructed from the momenta of 23O and the neutron. The spin parity of the first excited state, observed at E(x) = 4.65±0.14 MeV, was determined to be J(π) = 2+ from the angular distribution of the cross section. Higher-lying states were also observed. The quadrupole transition parameter ß2 of the 2(1)+ state was deduced, for the first time, to be 0.15±0.04. The relatively high excitation energy and small ß2 value are indicative of the N = 16 shell closure in 24O.

9.
Appl Radiat Isot ; 70(9): 2031-6, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22429558

RESUMO

A simple but versatile data acquisition system for software coincidence experiments is described, in which any time stamping and live time controller are not provided. Signals from ß- and γ-channels are fed to separately two fast ADCs (16 bits, 25 MHz clock maximum) via variable delay circuits and pulse-height stretchers, and also to pulse-height discriminators. The discriminating level was set to just above the electronic noise. Two ADCs were controlled with a common clock signal, and triggered simultaneously by the logic OR pulses from both discriminators. Paired digital signals for each sampling were sent to buffer memories connected to main PC with a FIFO (First-In, First-Out) pipe via USB. After data acquisition in list mode, various processing including pulse-height analyses was performed using MS-Excel (version 2007 and later). The usefulness of this system was demonstrated for 4πß(PS)-4πγ coincidence measurements of (60)Co, (134)Cs and (152)Eu. Possibilities of other extended applications will be touched upon.


Assuntos
Algoritmos , Armazenamento e Recuperação da Informação/métodos , Linguagens de Programação , Radiometria/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Software , Desenho de Equipamento , Análise de Falha de Equipamento , Design de Software
10.
Phys Rev Lett ; 106(20): 202501, 2011 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-21668223

RESUMO

The low-lying states in ¹°6Zr and ¹°8Zr have been investigated by means of ß-γ and isomer spectroscopy at the radioactive isotope beam factory (RIBF), respectively. A new isomer with a half-life of 620 ± 150 ns has been identified in ¹°8Zr. For the sequence of even-even Zr isotopes, the excitation energies of the first 2⁺ states reach a minimum at N = 64 and gradually increase as the neutron number increases up to N = 68, suggesting a deformed subshell closure at N = 64. The deformed ground state of ¹°8Zr indicates that a spherical subshell gap predicted at N = 70 is not large enough to change the ground state of ¹°8Zr to the spherical shape. The possibility of a tetrahedral shape isomer in ¹°8Zr is also discussed.

11.
Phys Rev Lett ; 106(5): 052502, 2011 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-21405387

RESUMO

The ß-decay half-lives of 38 neutron-rich isotopes from (36)Kr to (43)Tc have been measured; the half-lives of (100)Kr, (103-105)Sr, (106-108)Y, (108-110)Zr, (111,112)Nb, (112-115)Mo, and (116,117)Tc are reported here. The results when compared with previous standard models indicate an overestimation in the predicted half-lives by a factor of 2 or more in the A≈110 region. A revised model based on the second generation gross theory of ß decay better predicts the measured half-lives and suggests a more rapid flow of the rapid neutron-capture process (r-matter flow) through this region than previously predicted.

12.
Rev Sci Instrum ; 81(2): 023304, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192489

RESUMO

A multichannel time-of-flight (TOF) system was constructed to observe the ions generated from relativistic laser plasma, where the ions have polychromatic energies and multiple species. The TOF system is composed of a ten-channel scintillation detector array and an electromagnet that generates a magnetic field of 0-1.24 T. The magnet field enables us to analyze protons, deuterons, and full-stripped carbon ions to 50, 25, and 150 MeV, respectively. The system experimentally identified protons of 0.27-1.6 MeV energy and ions of a half specific charge (deuterons of 0.3-0.8 MeV and full-stripped carbons of 1.8-4.8 MeV). The measured TOF values agree well with the calculated values within the designed accuracy; +/-2.5 ns for protons and +/-5 ns for the others (d or C(6+)) on each detector channel. Comparison of ion numbers detected by a track detector (CR-39) and the TOF system enabled us to obtain the number of ions detected on each scintillation counter with less than 16% error.

13.
Appl Radiat Isot ; 68(7-8): 1445-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20022513

RESUMO

This work demonstrates the possibility of a gain shift or a peak-shape-deterioration with changes in the temperature of a long connecting cable between a pre-amplifier and a main amplifier in a Ge gamma-ray spectrometry system. The tests were performed for 50m-long RG174/U and RG58C/U cables with and without the termination. Such a temperature effect may cause from the temperature dependence of the resistivity of a central copper wire. In order to minimize such temperature effects in a Ge gamma-ray spectrometry, use of a terminator should be avoided.

14.
Phys Rev Lett ; 103(3): 032501, 2009 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-19659270

RESUMO

We report on the first spectroscopic study of the N=22 nucleus 32Ne at the newly completed RIKEN Radioactive Ion Beam Factory. A single gamma-ray line with an energy of 722(9) keV was observed in both inelastic scattering of a 226 MeV/u 32Ne beam on a carbon target and proton removal from 33Na at 245 MeV/u. This transition is assigned to the deexcitation of the first Jpi=2+ state in 32Ne to the 0+ ground state. Interpreted through comparison with state-of-the-art shell-model calculations, the low excitation energy demonstrates that the "island of inversion" extends to at least N=22 for the Ne isotopes.

15.
Phys Rev Lett ; 103(26): 262501, 2009 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-20366309

RESUMO

The cross sections for single-neutron removal from the very neutron-rich nucleus 31Ne on Pb and C targets have been measured at 230 MeV/nucleon using the RIBF facility at RIKEN. The deduced large Coulomb breakup cross section of 540(70) mb is indicative of a soft E1 excitation. Comparison with direct-breakup model calculations suggests that the valence neutron of 31Ne occupies a low-l orbital (most probably 2p(3/2)) with a small separation energy (S(n) approximately < 0.8 MeV), instead of being predominantly in the 1f(7/2) orbital as expected from the conventional shell ordering. These findings suggest that 31Ne is the heaviest halo system known.

16.
NMR Biomed ; 21(10): 1066-75, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18816480

RESUMO

Citicoline supplementation has been used to ameliorate memory disturbances in older people and those with Alzheimer's disease. This study used MRS to characterize the effects of citicoline on high-energy phosphate metabolites and constituents of membrane synthesis in the frontal lobe. Phosphorus ((31)P) metabolite data were acquired using a three-dimensional chemical-shift imaging protocol at 4 T from 16 healthy men and women (mean +/- SD age 47.3 +/- 5.4 years) who orally self-administered 500 mg or 2000 mg Cognizin Citicoline (Kyowa Hakko Kogyo Co., Ltd, Ibaraki, Japan) for 6 weeks. Individual (31)P metabolites were quantified in the frontal lobe (anterior cingulate cortex) and a comparison region (parieto-occipital cortex). Significant increases in phosphocreatine (+7%), beta-nucleoside triphosphates (largely ATP in brain, +14%) and the ratio of phosphocreatine to inorganic phosphate (+32%), as well as significant changes in membrane phospholipids, were observed in the anterior cingulate cortex after 6 weeks of citicoline treatment. These treatment-related alterations in phosphorus metabolites were not only regionally specific, but tended to be of greater magnitude in subjects who received the lower dose. These data show that citicoline improves frontal lobe bioenergetics and alters phospholipid membrane turnover. Citicoline supplementation may therefore help to mitigate cognitive declines associated with aging by increasing energy reserves and utilization, as well as increasing the amount of essential phospholipid membrane components needed to synthesize and maintain cell membranes.


Assuntos
Citidina Difosfato Colina/administração & dosagem , Lobo Frontal/efeitos dos fármacos , Lobo Frontal/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Fósforo/análise , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nootrópicos/administração & dosagem
17.
Kyobu Geka ; 61(4): 303-9, 2008 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-18411694

RESUMO

We assessed the effect of reconstructing the pulmonary artery during arterial switch surgery for transposition of the great arteries on late pulmonary stenosis. Sixty-five patients who underwent Lecompte procedure between September 1991 and December 2006 were divided, by the procedure used chronologically to reconstruct the pulmonary artery, into group XP (single pantaloon patch with equine pericardium, n = 11), group P (direct reconstruction, n = 47), and group AP (single pantaloon patch with fresh autopericardium, n = 7). Outcome and pulmonary stenosis on the most recent ultrasound cardiography (UCG) were compared in the 3 groups. The median follow-up was 13, 7.5, and 1.3 years, respectively. Both early and late mortalities were 1.5% (1/65). Although percutaneous trans-pulmonary angioplasty was necessary in 1, 13, and 3 patients, there was 1, 1, and 0 reoperation for pulmonary stenosis in the 3 groups, respectively. Pulmonary stenosis (pulmonary arterial maximum flow velocity > 3 m/sec on UCG) was present in 4 (40%). 14 (30%). and 3 patients (43%). Although there was no significant difference among the 3 procedures in preventing pulmonary stenosis 10 years after arterial switch surgery, direct reconstruction of the pulmonary artery may show a superior outcome, in particular, over 10 years after arterial switch surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Artéria Pulmonar/cirurgia , Transposição dos Grandes Vasos/cirurgia , Seguimentos , Humanos , Lactente , Recém-Nascido , Estenose da Valva Pulmonar/prevenção & controle
18.
Appl Radiat Isot ; 66(6-7): 909-13, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18378155

RESUMO

Alpha 4pi(beta+gamma) integral counting technique using a 4pibeta-4pigamma detector configuration was adopted for the standardization of (18)F. In this technique, the beta-detector is composed of two thin plastic scintillators sandwiching the source, coupled with a slender photomultiplier tube. The beta-detector part with the source was inserted into a large well-type NaI(Tl) scintillation detector for gamma-ray detection, making a 4pibeta-4pigamma coincidence counting system. In this work, positron particles were detected with high efficiency in the beta-channel and annihilation quanta were also detected with high efficiency in the 4pigamma channel. The very small inefficiency of the 4pi(beta+gamma) integral counter for the beta-plus branch has been confirmed by EGS5 Monte Carlo simulation. The result using this technique agreed within the uncertainties with the result obtained by the conventional 4pibeta-gamma coincidence counting with the efficiency extrapolation technique using the same detector configuration and a conventional 4pibeta-gamma coincidence counter.

19.
Appl Radiat Isot ; 66(6-7): 819-22, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18387807

RESUMO

beta-Ray spectra after penetrating absorbing materials of various thicknesses were observed by the use of a scintillation-type beta-ray spectrometer equipped with a flat NE-102 plastic scintillator of 5mm thickness for sources of (60)Co, (90)Sr-(90)Y, (137)Cs, (147)Pm and (204)Tl. Although the spectra changed rapidly with increasing absorber thickness, the average beta-ray energy was kept nearly constant for a wider range. These results are consistent in that the beta-ray absorption curve becomes quasi-linear in a semi-logarithmic plot. Spectra including scattered beta-rays from several materials placed behind the source were also measured for (137)Cs and (204)Tl. It may be concluded that mean energy measurements by the use of beta-ray spectrometer of this kind is useful for the identification of nuclides in radiation protection purposes even in worse source-conditions.

20.
Arch Virol ; 153(5): 945-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18227965

RESUMO

To determine the influence of oseltamivir phosphate (Tamiflu) on the results of microneutralization and hemagglutinin-inhibition (HI) tests in human sera with H5N2 influenza virus, ten volunteers were administered Tamiflu and blood samples were collected. In the microneutralization test, no consistent effects were observed. However, in the HI test, specimens from all volunteers taken at 4 and 7 h after drug administration showed a higher titer as compared to 0 and 24 h after administration when mammalian cells (horse, guinea pig, and human) were used. These results suggest that the administration of Tamiflu may affect the results of HI tests for H5N2 virus.


Assuntos
Antivirais/sangue , Testes de Inibição da Hemaglutinação , Vírus da Influenza A Subtipo H5N2/efeitos dos fármacos , Vírus da Influenza A Subtipo H5N2/isolamento & purificação , Testes de Neutralização , Oseltamivir/sangue , Adulto , Animais , Anticorpos Antivirais/sangue , Feminino , Cobaias , Cavalos , Humanos , Vírus da Influenza A Subtipo H5N2/imunologia , Influenza Humana/diagnóstico , Influenza Humana/imunologia , Influenza Humana/virologia , Japão , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...