Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Nucl Med ; 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38331457

RESUMO

There is a clinical need for 18F-labeled somatostatin analogs for the imaging of neuroendocrine tumors (NET), given the limitations of using [68Ga]Ga-DOTA-peptides, particularly with regard to widespread accessibility. We have shown that [18F]fluoroethyl-triazole-[Tyr3]-octreotate ([18F]FET-ßAG-TOCA) has favorable dosimetry and biodistribution. As a step toward clinical implementation, we conducted a prospective, noninferiority study of [18F]FET-ßAG-TOCA PET/CT compared with [68Ga]Ga-DOTA- peptide PET/CT in patients with NET. Methods: Forty-five patients with histologically confirmed NET, grades 1 and 2, underwent PET/CT imaging with both [18F]FET-ßAG-TOCA and [68Ga]Ga-peptide performed within a 6-mo window (median, 77 d; range, 6-180 d). Whole-body PET/CT was conducted 50 min after injection of 165 MBq of [18F]FET-ßAG-TOCA. Tracer uptake was evaluated by comparing SUVmax and tumor-to-background ratios at both lesion and regional levels by 2 unblinded, experienced readers. A randomized, blinded reading of both scans was also then undertaken by 3 experienced readers, and consensus was assessed at a regional level. The ability of both tracers to visualize liver metastases was also assessed. Results: A total of 285 lesions were detected on both imaging modalities. An additional 13 tumor deposits were seen in 8 patients on [18F]FET-ßAG-TOCA PET/CT, and [68Ga]Ga-DOTA-peptide PET/CT detected an additional 7 lesions in 5 patients. Excellent correlation in SUVmax was observed between both tracers (r = 0.91; P < 0.001). No difference was observed between median SUVmax across regions, except in the liver, where the median tumor-to-background ratio of [18F]FET-ßAG-TOCA was significantly lower than that of [68Ga]Ga-DOTA-peptide (2.5 ± 1.9 vs. 3.5 ± 2.3; P < 0.001). Conclusion: [18F]FET-ßAG-TOCA was not inferior to [68Ga]Ga-DOTA-peptide in visualizing NET and may be considered in routine clinical practice given the longer half-life and availability of the cyclotron-produced fluorine radioisotope.

2.
Methods ; 185: 110-119, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32006678

RESUMO

This work demonstrates how computational and physical modelling of the positron emission tomography (PET) image acquisition process for a state-of-the-art integrated PET and magnetic resonance imaging (PET-MR) system can produce images comparable to the manufacturer. The GE SIGNA PET/MR scanner is manufactured by General Electric and has time-of-flight (TOF) capabilities of about 390 ps. All software development took place in the Software for Tomographic Image Reconstruction (STIR: http://stir.sf.net) library, which is a widely used open source software to reconstruct data as exported from emission tomography scanners. The new software developments will be integrated into STIR, providing the opportunity for researchers worldwide to establish and expand their image reconstruction methods. Furthermore, this work is of particular significance as it provides the first validation of TOF PET image reconstruction for real scanner datasets using the STIR library. This paper presents the methodology, analysis, and critical issues encountered in implementing an independent reconstruction software package. Acquired PET data were processed via several appropriate algorithms which are necessary to produce an accurate and precise quantitative image. This included mathematical, physical and anatomical modelling of the patient and simulation of various aspects of the acquisition. These included modelling of random coincidences using 'singles' rates per crystals, detector efficiencies and geometric effects. Attenuation effects were calculated by using the STIR's attenuation correction model. Modelling all these effects within the system matrix allowed the reconstruction of PET images which demonstrates the metabolic uptake of the administered radiopharmaceutical. These implementations were validated using measured phantom and clinical datasets. The developments are tested using the ordered subset expectation maximisation (OSEM) and the more recently proposed kernelised expectation maximisation (KEM) algorithm which incorporates anatomical information from MR images into PET reconstruction.


Assuntos
Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Software , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador , Modelos Biológicos , Modelos Teóricos , Fibrose Pulmonar/diagnóstico por imagem
3.
Eur J Nucl Med Mol Imaging ; 47(11): 2549-2561, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32123971

RESUMO

BACKGROUND: Fatty acids derived de novo or taken up from the extracellular space are an essential source of nutrient for cell growth and proliferation. Radiopharmaceuticals including 11C-acetate, and 18F-FAC (2-18F-fluoroacetate), have previously been used to study short-chain fatty acid (SCFA) metabolism. We developed 18F-fluoropivalate (18F-FPIA; 3-18F-fluoro-2,2-dimethylpropionic acid) bearing a gem-dimethyl substituent to assert metabolic stability for studying SCFA metabolism. We report the safety, biodistribution, and internal radiation dosimetry profile of 18F-FPIA in 24 healthy volunteers and the effect of dietary conditions. MATERIALS AND METHODS: Healthy volunteer male and female subjects were enrolled (n = 24), and grouped into 12 fed and 12 fasted. Non-esterified fatty acids (NEFA) and carnitine blood measurements were assessed. Subjects received 159.48 MBq (range, 47.31-164.66 MBq) of 18F-FPIA. Radiochemical purity was > 99%. Safety data were obtained during and 24 h after radiotracer administration. Subjects underwent detailed multiple whole-body PET/CT scanning with sampling of venous bloods for radioactivity and radioactive metabolite quantification. Regions of interest were defined to derive individual and mean organ residence times; effective dose was calculated using OLINDA 1.1. RESULTS: All subjects tolerated 18F-FPIA with no adverse events. Over 90% of radiotracer was present in plasma at 60 min post-injection. The organs receiving highest absorbed dose (in mGy/MBq) were the liver (0.070 ± 0.023), kidneys (0.043 ± 0.013), gallbladder wall (0.026 ± 0.003), and urinary bladder (0.021 ± 0.004); otherwise there was low tissue uptake. The calculated effective dose using mean organ residence times over all 24 subjects was 0.0154 mSv/MBq (SD ± 0.0010). No differences in biodistribution or dosimetry were seen in fed and fasted subjects, though systemic NEFA and carnitine levels reflected fasted and fed states. CONCLUSION: The favourable safety, imaging, and dosimetric profile makes 18F-FPIA a promising candidate radiotracer for tracing SCFA metabolism.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Ácidos Graxos Voláteis , Feminino , Voluntários Saudáveis , Humanos , Masculino , Radiometria , Compostos Radiofarmacêuticos , Distribuição Tecidual
4.
Eur J Nucl Med Mol Imaging ; 47(4): 958-966, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31897589

RESUMO

PURPOSE: Integrin αvß6 belongs to the RGD subset of the integrin family, and its expression levels are a prognostic and theranostic factor in some types of cancer and pulmonary fibrosis. This paper describes the GMP radiolabelling of the synthetic 20 amino acid peptide A20FMDV2 (NAVPNLRGDLQVLAQKVART), derived from the foot-and-mouth disease virus, and characterises the use of [18F]FB-A20FMDV2 as a high affinity, specific and selective PET radioligand for the quantitation and visualisation of αvß6 in rodent lung to support human translational studies. METHODS: The synthesis of [18F]FB-A20FMDV2 was performed using a fully automated and GMP-compliant process. Sprague-Dawley rats were used to perform homologous (unlabelled FB-A20FMDV2) and heterologous (anti-αvß6 antibody 8G6) blocking studies. In order to generate a dosimetry estimate, tissue residence times were generated, and associated tissue exposure and effective dose were calculated using the Organ Level Internal Dose Assessment/Exponential Modelling (OLINDA/EXM) software. RESULTS: [18F]FB-A20FMDV2 synthesis was accomplished in 180 min providing ~800 MBq of [18F]FB-A20FMDV2 with a molar activity of up to 150 GBq/µmol and high radiochemical purity (> 97%). Following i.v. administration to rats, [18F]FB-A20FMDV2 was rapidly metabolised with intact radiotracer representing 5% of the total radioactivity present in rat plasma at 30 min. For the homologous and heterologous block in rats, lung-to-heart SUV ratios at 30-60 min post-administration of [18F]FB-A20FMDV2 were reduced by 38.9 ± 6.9% and 56 ± 19.2% for homologous and heterologous block, respectively. Rodent biodistribution and dosimetry calculations using OLINDA/EXM provided a whole body effective dose in humans 33.5 µSv/MBq. CONCLUSION: [18F]FB-A20FMDV2 represents a specific and selective PET ligand to measure drug-associated αvß6 integrin occupancy in lung. The effective dose, extrapolated from rodent data, is in line with typical values for compounds labelled with fluorine-18 and combined with the novel fully automated and GMP-compliant synthesis and allows for clinical use in translational studies.


Assuntos
Integrinas , Roedores , Animais , Antígenos de Neoplasias , Cadeias beta de Integrinas , Integrinas/metabolismo , Pulmão/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Ratos , Ratos Sprague-Dawley , Roedores/metabolismo , Distribuição Tecidual
5.
EJNMMI Res ; 8(1): 71, 2018 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-30062395

RESUMO

BACKGROUND: We measured whole body distribution of 11C-BU99008, a new PET biomarker for non-invasive identification of the imidazoline2 binding site. The purpose of this phase I study was to evaluate the biodistribution and radiation dosimetry of 11C-BU99008 in healthy human subjects. METHODS: A single bolus injection of 11C-BU99008 (296 ± 10.5 MBq) was administered to four healthy subjects who underwent whole-body PET/CT over 120 min from the cranial vertex to the mid-thigh. Volumes of interest were drawn around visually identifiable source organs to generate time-activity curves (TAC). Residence times were determined from time-activity curves. Absorbed doses to individual organs and the whole body effective dose were calculated using OLINDA/EXM 1.1 for each subject. RESULTS: The highest measured activity concentration was in the kidney and spleen. The longest residence time was in the muscle at 0.100 ± 0.023 h, followed by the liver at 0.067 ± 0.015 h and lungs at 0.052 ± 0.010 h. The highest mean organ absorbed dose was within the heart wall (0.028 ± 0.002 mGy/MBq), followed by the kidneys (0.026 ± 0.005 mGy/MBq). The critical organ was the heart wall. The total mean effective dose averaged over subjects was estimated to be 0.0056 ± 0.0004 mSv/MBq for an injection of 11C-BU99008. CONCLUSIONS: The biodistribution of 11C-BU99008 has been shown here for the first time in humans. Our dosimetry data showed the total mean effective dose over all subjects was 0.0056 ± 0.0004 mSv/MBq, which would result in a total effective dose of 1.96 mSv for a typical injection of 350 MBq of 11C-BU99008. The effective dose is not appreciably different from those obtained with other 11C tracers.

6.
J Nucl Med Technol ; 46(2): 136-143, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29438002

RESUMO

The αvß6 integrin is involved in the pathogenesis of cancer and fibrosis. A radiolabeled 20-amino-acid αvß6-binding peptide, derived from the foot and mouth virus (NAVPNLRGDLQVLAQKVART [A20FMDV2]), has been developed to image αvß6 levels preclinically. This study was designed to translate these findings into a clinical PET imaging protocol to measure the expression of αvß6 in humans. Methods: Preclinical toxicology was undertaken, and a direct immunoassay was developed for 4-fluorobenzamide (FB)-A20FMDV2. Four healthy human subjects (2 male and 2 female) received a single microdose of 18F-FB-A20FMDV2 followed by a multibed PET scan of the whole body over more than 3 h. Results: There were no findings in the preclinical toxicology assessments, and no anti-A20FMDV2 antibodies were detected before or after dosing with the PET ligand. The mean and SD of the administered mass of 18F-FB-A20FMDV2 was 8.7 ± 4.4 µg (range, 2.7-13.0 µg). The mean administered activity was 124 ± 20 MBq (range, 98-145 MBq). There were no adverse or clinically detectable pharmacologic effects in any of the subjects. No significant changes in vital signs, laboratory study results, or electrocardiography results were observed. Uptake of radioactivity was observed in the thyroid, salivary glands, liver, stomach wall, spleen, kidneys, ureters, and bladder. Time-activity curves indicated that the highest activity was in the bladder content, followed by the kidneys, small intestine, stomach, liver, spleen, thyroid, and gallbladder. The largest component of the residence times was the voided urine, followed by muscle, bladder, and liver. Using the mean residence time over all subjects as input to OLINDA/EXM, the effective dose was determined to be 0.0217 mSv/MBq; using residence times from single subjects gave an SD of 0.0020 mSv/MBq from the mean. The critical organ was the urinary bladder, with an absorbed dose of 0.18 mGy/MBq. Conclusion:18F-FB-A20FMDV2 successfully passed toxicology criteria, showed no adverse effects in this first-in-humans study, and has an effective dose that enables multiple scans in a single subject.


Assuntos
Antígenos de Neoplasias/metabolismo , Radioisótopos de Flúor , Integrinas/metabolismo , Fragmentos de Peptídeos/imunologia , Fragmentos de Peptídeos/farmacocinética , Tomografia por Emissão de Pósitrons/métodos , Doses de Radiação , Segurança , Idoso , Sequência de Aminoácidos , Feminino , Vírus da Febre Aftosa , Humanos , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/efeitos adversos , Fragmentos de Peptídeos/química , Radiometria , Distribuição Tecidual , Proteínas Virais/química
7.
J Nucl Med ; 57(8): 1207-13, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27173162

RESUMO

UNLABELLED: We conducted the first-in-human study of (18)F-fluoroethyl triazole [Tyr(3)] octreotate ((18)F-FET-ßAG-TOCA) in patients with neuroendocrine tumors (NETs) to evaluate biodistribution, dosimetry, and safety. Despite advances in clinical imaging, detection and quantification of NET activity remains a challenge, with no universally accepted imaging standard. METHODS: Nine patients were enrolled. Eight patients had sporadic NETs, and 1 had multiple endocrine neoplasia type 1 syndrome. Patients received 137-163 MBq (mean ± SD, 155.7 ± 8 MBq) of (18)F-FET-ßAG-TOCA. Safety data were obtained during and 24 h after radioligand administration. Patients underwent detailed whole-body PET/CT multibed scanning over 4 h with sampling of venous bloods for radioactivity and radioactive metabolite quantification. Regions of interest were defined to derive individual and mean organ residence times; effective dose was calculated with OLINDA 1.1. RESULTS: All patients tolerated (18)F-FET-ßAG-TOCA with no adverse events. Over 60% parent radioligand was present in plasma at 60 min. High tumor (primary and metastases)-to-background contrast images were observed. Physiologic distribution was seen in the pituitary, salivary glands, thyroid, and spleen, with low background distribution in the liver, an organ in which metastases commonly occur. The organs receiving highest absorbed dose were the gallbladder, spleen, stomach, liver, kidneys, and bladder. The calculated effective dose over all subjects (mean ± SD) was 0.029 ± 0.004 mSv/MBq. CONCLUSION: The favorable safety, imaging, and dosimetric profile makes (18)F-FET-ßAG-TOCA a promising candidate radioligand for staging and management of NETs. Clinical studies in an expanded cohort are ongoing to clinically qualify this agent.


Assuntos
Radioisótopos de Flúor/química , Marcação por Isótopo/métodos , Octreotida , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos/síntese química , Adulto , Idoso , Química Click/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tumores Neuroendócrinos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Mol Imaging Biol ; 14(4): 517-21, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22076076

RESUMO

PURPOSE: We measured the whole-body distribution of IV-injected [¹¹C]GSK215083, a new 5-HT6 antagonist PET tracer, as a function of time in adult subjects, in order to determine the radiation exposure. PROCEDURES: After injection with a single bolus of [¹¹C]GSK215083 (range 330-367 MBq; mean 346 MBq), PET emission data were acquired for approximately 120 min in six subjects (three males and three females). Five organs were identified as exhibiting uptake above background. For these, regions of interest were delineated on emission images, and time-activity curves (TAC) generated. Residence times were calculated as the area under the curve of the TAC, normalized to injected activities and standard values of organ volumes. Dosimetry calculations were then performed using the computer program OLINDA/EXM 1.0. RESULTS: The mean effective dose averaged over both males and females (deviation) was estimated to be 7.7 ± 1.0 µSv/MBq (male 7.0 ± 0.4; female 8.5 ± 0.6). For the effective dose equivalent, the corresponding values are 7.8 ± 1.2 µSv/MBq (male 6.8 ± 0.5; female 8.9 ± 0.1). The organ receiving the highest dose was the lung, with an average equivalent dose of 25.6 ± 6.9 µSv/MBq (male 20.8 ± 5.6; female 30.4 ± 4.4). CONCLUSION: The estimated radiation dose for [¹¹C]GSK215083 is consistent with those for other neuroreceptor ligands labeled with carbon-11. The somewhat higher dose estimate for females compared to males may reflect the difference in observed residence times and representative differences in the male and female phantoms used for dosimetry calculations. Based on conventionally accepted dose limits, [¹¹C]GSK215083 may be used for multiple PET scans in the same subject.


Assuntos
Tomografia por Emissão de Pósitrons/métodos , Quinolinas/farmacocinética , Radiometria/métodos , Receptores de Serotonina/metabolismo , Sulfonas/farmacocinética , Imagem Corporal Total/métodos , Adolescente , Adulto , Radioisótopos de Carbono , Relação Dose-Resposta à Radiação , Feminino , Humanos , Injeções Intravenosas , Ligantes , Masculino , Especificidade de Órgãos/efeitos dos fármacos , Quinolinas/administração & dosagem , Quinolinas/farmacologia , Sulfonas/administração & dosagem , Sulfonas/farmacologia , Fatores de Tempo , Distribuição Tecidual/efeitos dos fármacos , Adulto Jovem
9.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 63(5): 534-45, 2007 May 20.
Artigo em Japonês | MEDLINE | ID: mdl-17538218

RESUMO

Although many current CT scanners incorporate CT-AEC, performance evaluation is not standardized. This study evaluates the performance of the latest CT-AEC of each manufacturer with the aim of establishing a standard CT-AEC performance evaluation method. The design of the phantoms was based upon the operation characteristics of different CT-AECs. A cone, an ellipse, a variable-shaped ellipse, stepped phantoms, and their analysis software were devised and carried out the field test. The targets were LightSpeed VCT 64 with 2D and 3D Auto mA(GE), Aquilion 64M with Real-EC and Volume-EC(Toshiba), Sensation 64 with CARE Dose and CARE Dose 4D(Siemens), and Bulliance 16P with Dose Right(Philips). Data was acquired while varying the typical abdominal CT(with CT-AEC)scanning conditions (120 kV, 5 mm slice, standard function for abdomen, scanning range 200 mm). The acquired images were converted to the DICOM format and image noise(SD) was calculated using dedicated software. All 4 CT-AECs reduced exposure dose. For GE and Toshiba, image noise was constant and met the target. For Siemens, noise was independent of phantom shape but varied uniformly with phantom size. For Philips, noise varied with phantom size and shape, and variation degree depended on phantom thickness in scanogram direction. The results reflect the basic concept and performance characteristics of the methods. Standardization of CT-AEC performance evaluation is possible using these phantoms.


Assuntos
Tomografia Computadorizada por Raios X/instrumentação , Imagens de Fantasmas , Radiografia Abdominal/instrumentação , Tomografia Computadorizada por Raios X/normas
10.
Radiographics ; 24(6): 1679-91, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15537976

RESUMO

Artifacts can seriously degrade the quality of computed tomographic (CT) images, sometimes to the point of making them diagnostically unusable. To optimize image quality, it is necessary to understand why artifacts occur and how they can be prevented or suppressed. CT artifacts originate from a range of sources. Physics-based artifacts result from the physical processes involved in the acquisition of CT data. Patient-based artifacts are caused by such factors as patient movement or the presence of metallic materials in or on the patient. Scanner-based artifacts result from imperfections in scanner function. Helical and multisection technique artifacts are produced by the image reconstruction process. Design features incorporated into modern CT scanners minimize some types of artifacts, and some can be partially corrected by the scanner software. However, in many instances, careful patient positioning and optimum selection of scanning parameters are the most important factors in avoiding CT artifacts.


Assuntos
Artefatos , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...