Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artif Organs ; 42(6): 597-604, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29508418

RESUMO

Circulatory failure following cardiac arrest (CA) requires catecholamine support and occasionally veno-arterial extracorporeal membrane oxygenation (vaECMO). VaECMO-generated blood flow is continuous and retrograde, increasing ventricular stroke work. Our aim was to assess the benefit of a device generating a pulsatile vaECMO flow synchronized with the heart rhythm lowering systolic vaECMO output on the left ventricular ejection fraction (LVEF) and pulmonary capillary pressure (Pcap) after CA. This experimental randomized study in pigs compared standard nonpulsatile vaECMO (control) with pulsatile synchronized vaECMO (study) group using a pulsatility-generating device. After sedation and intubation, ventricular fibrillation was induced by pacing. After 10-min ventricular fibrillation, cardiopulmonary resuscitation was performed for 20 min then vaECMO, defibrillation and 0.15 µg/kg/min intravenous epinephrine infusion were initiated. Hemodynamics, Pcap, LVEF by echocardiography and angiography were measured at baseline and every 30 min after the vaECMO start until vaECMO and epinephrine were stopped (at 120 min), and 30 min later. Baseline hemodynamics did not differ between groups; 120 min after vaECMO initiation, LVEF by echocardiography and angiography was significantly higher in the study than control group 55 ± 19% versus 34 ± 13% (P = 0.042), 50 ± 16% versus 33 ± 12% (P = 0.043), respectively. Pcap decreased from baseline by 4.2 ± 8.6 mm Hg in the study group but increased by 5.6 ± 5.9 mm Hg in the control group (P = 0.043). Thirty minutes later, LVEF remained higher in the study group 44 ± 7% versus 26 ± 11% (P = 0.008) while Pcap did not differ. A synchronized pulsatile device decreasing systolic output from vaECMO improved LVEF and Pcap in a pig model of CA and resuscitation.


Assuntos
Oxigenação por Membrana Extracorpórea/instrumentação , Parada Cardíaca/terapia , Coração/fisiopatologia , Animais , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Parada Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Fluxo Pulsátil , Suínos
2.
Acute Card Care ; 18(2): 42-44, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28328285

RESUMO

AIM: To examine whether pulmonary artery balloon pulsation (PABP) could improve circulatory function in acute myocardial infarction (AMI) in pigs. METHODS/RESULTS: Ten downsize pigs were sedated and ventilated. AMI was induced by inserting a plug into the left anterior descending artery. A pulsation balloon was placed in the pulmonary artery in all animals. In the treatment group (TG), pulsations began when life-threatening arrhythmia or > 30% drop in mean blood pressure (MBP) or > 40% decrease in cardiac output compared to baseline occurred. Pulsation rate was 120/min, independent of the heartbeat, maintained for 10 min. The control group (CG) received no pulsation. In the TG (n = 5), mean BP after the AMI improved by 7 ± 12 mmHg after 150 min while in the CG, MBP decreased by 17 ± 25 mmHg, P < 0.05; coronary perfusion pressure improved by 8 ± 7 mmHg in the TG but decreased by 15 ± 12 in the CG (P < 0.05). In the CG, cardiac output did not change but in the TG it improved from 3.5 ± 0.9 after the AMI to 4.2 ± 1.1 l/min 150 min after AMI (P < 0.05). The TG required 1.8 ± 0.4 electric shocks for ventricular fibrillation versus 0.8 ± 0.4 in the pulsation group (P < 0.05). CONCLUSION: PABP could be useful in the management of AMI due to improved mean arterial BP, coronary perfusion pressure, cardiac output and electrical stability. The mechanism of this effect remains to be determined.


Assuntos
Arritmias Cardíacas/prevenção & controle , Circulação Assistida , Insuficiência Cardíaca/prevenção & controle , Infarto do Miocárdio/terapia , Artéria Pulmonar/fisiologia , Animais , Arritmias Cardíacas/fisiopatologia , Pressão Arterial , Circulação Assistida/instrumentação , Circulação Assistida/métodos , Modelos Animais de Doenças , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar , Infarto do Miocárdio/fisiopatologia , Suínos , Resultado do Tratamento
3.
Acta Ophthalmol ; 92(5): e382-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25043792

RESUMO

PURPOSE: Determine the effect of repeated intravitreal injections of ranibizumab (0.5 mg; 0.05 ml) on retrobulbar blood flow velocities (BFVs) using ultrasound imaging quantification in twenty patients with exudative age-related macular degeneration treated for 6 months. METHODS: Visual acuity (ETDRS), central macular thickness (OCT), peak-systolic, end-diastolic and mean-BFVs in central retinal (CRA), temporal posterior ciliary (TPCA) and ophthalmic (OA) arteries were measured before, 2 days, 3 weeks and 6 months after the first injection. Patients were examined monthly and received 1-5 additional injections depending on ophthalmologic examination results. RESULTS: Six months after the first injection, a significant increase in visual acuity 50.9 ± 25.9 versus 44.4 ± 21.7 (p < 0.01) and decrease in mean central macular thickness 267 ± 74 versus 377 ± 115 µm (p < 0.001) were observed compared to baseline. Although mean-BFVs decreased by 16%±3% in CRA and 20%±5% in TPCA (p < 0.001) 2 days after the first injection, no significant change was seen thereafter. Mean-BFVs in OA decreased by 19%±5% at week 3 (p < 0.001). However, the smallest number of injections (two injections) was associated with the longest time interval between the last injection and month 6 (20 weeks) and with the best return to baseline levels for mean-BFVs in CRA, suggesting that ranibizumab had reversible effects on native retinal vascular supply after its discontinuation. Moreover, a significant correlation between the number of injections and percentage of changes in mean-BFVs in CRA was observed at month 6 (R = 0.74, p < 0.001) unlike TPCA or OA. CONCLUSION: Ranibizumab could impair the native choroidal and retinal vascular networks, but its effect seems reversible after its discontinuation.


Assuntos
Inibidores da Angiogênese/uso terapêutico , Anticorpos Monoclonais Humanizados/uso terapêutico , Artérias Ciliares/fisiologia , Artéria Oftálmica/fisiologia , Artéria Retiniana/fisiologia , Degeneração Macular Exsudativa/tratamento farmacológico , Degeneração Macular Exsudativa/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Feminino , Humanos , Pressão Intraocular , Injeções Intravítreas , Masculino , Estudos Prospectivos , Ranibizumab , Fluxo Sanguíneo Regional , Retratamento , Ultrassonografia Doppler em Cores , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...