Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 59(2-3): 137-43, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12941503

RESUMO

A non-destructive technique to determine the time since last purification of weapons grade plutonium based on the 241Pu decay series has been developed and demonstrated to provide results that are consistent with our historical and process knowledge. This method is based on the use of the Bateman equations and the decay chain 241Pu-->237U & 241Am-->237Np-->233Pa. Secular equilibrium is assumed between the (2.1 x 10(6) year) 237Np and the (27 day) 233Pa. The proposed method is dependent upon the efficiency of the plutonium separation process but makes no assumption about the relative abundance of 241Pu in 239Pu. Even though the technique was developed for weapons grade plutonium, it is expected to apply to almost any material that contains plutonium.


Assuntos
Algoritmos , Modelos Químicos , Plutônio/análise , Plutônio/isolamento & purificação , Resíduos Radioativos/análise , Radiometria/métodos , Espectrometria gama/métodos , Meia-Vida , Plutônio/química , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Radiat Meas ; 26(1): 17-34, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11539199

RESUMO

A joint investigation between the United States and Russia to study the radiation environment inside the Space Shuttle flight STS-60 was carried out as part of the Shuttle-Mir Science Program (Phase 1). This is the first direct comparison of a number of different dosimetric measurement techniques between the two countries. STS-60 was launched on 3 February 1994 in a nearly circular 57 degrees x 353 km orbit with five U.S. astronauts and one Russian cosmonaut for 8.3 days. A variety of instruments provided crew radiation exposure, absorbed doses at fixed locations, neutron fluence and dose equivalent, linear energy transfer (LET) spectra of trapped and galactic cosmic radiation, and energy spectra and angular distribution of trapped protons. In general, there is good agreement between the U.S. and Russian measurements. The AP8 Min trapped proton model predicts an average of 1.8 times the measured absorbed dose. The average quality factor determined from measured lineal energy, y, spectra using a tissue equivalent proportional counter (TEPC), is in good agreement with that derived from the high temperature peak in the 6LiF thermoluminescent detectors (TLDs). The radiation exposure in the mid-deck locker from neutrons below 1 MeV was 2.53 +/- 1.33 microSv/day. The absorbed dose rates measured using a tissue equivalent proportional counter, were 171.1 +/- 0.4 and 127.4 +/- 0.4 microGy/day for trapped particles and galactic cosmic rays, respectively. The combined dose rate of 298.5 +/- 0.82 microGy/day is about a factor of 1.4 higher than that measured using TLDs. The westward longitude drift of the South Atlantic Anomaly (SAA) is estimated to be 0.22 +/- 0.02 degrees/y. We evaluated the effects of spacecraft attitudes on TEPC dose rates due to the highly anisotropic low-earth orbit proton environment. Changes in spacecraft attitude resulted in dose-rate variations by factors of up to 2 at the location of the TEPC.


Assuntos
Nêutrons , Prótons , Monitoramento de Radiação/instrumentação , Voo Espacial/instrumentação , Dosimetria Termoluminescente/instrumentação , Oceano Atlântico , Humanos , Cooperação Internacional , Transferência Linear de Energia , Doses de Radiação , Radiometria , Federação Russa , Atividade Solar , Estados Unidos
3.
Radiat Meas ; 24(3): 283-9, 1995 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11539130

RESUMO

A joint NASA-Russian study of the radiation environment inside a SPACEHAB 2 locker on Space Shuttle flight STS-57 was conducted. The Shuttle flew in a nearly circular orbit of 28.5 degrees inclination and 462 km altitude. The locker carried a charged particle spectrometer, a tissue equivalent proportional counter (TEPC), and two area passive detectors consisting of combined NASA plastic nuclear track detectors (PNTDs) and thermoluminescent detectors (TLDs), and Russian nuclear emulsions, PNTDs and TLDs. All the detector systems were shielded by the same Shuttle mass distribution. This makes possible a direct comparison of the various dose measurement techniques. In addition, measurements of the neutron energy spectrum were made using the proton recoil technique. The results show good agreement between the integral LET spectrum of the combined galactic and trapped particles using the tissue equivalent proportional counter and track detectors between about 15 keV/micrometers and 200 keV/micrometers. The LET spectrum determined from nuclear emulsions was systematically lower by about 50%, possibly due to emulsion fading. The results show that the TEPC measured an absorbed dose 20% higher than the TLDs, due primarily to an increased TEPC response to neutrons and a low sensitivity of TLDs to high LET particles under normal processing techniques. There is a significant flux of high energy neutrons that is currently not taken into consideration in dose equivalent calculations. The results of the analysis of the spectrometer data will be reported separately.


Assuntos
Radiação Cósmica , Transferência Linear de Energia , Nêutrons , Monitoramento de Radiação/métodos , Voo Espacial/instrumentação , Dosimetria Termoluminescente , Doses de Radiação , Monitoramento de Radiação/instrumentação , Proteção Radiológica , Radiometria , Astronave/instrumentação
4.
J Clin Pathol ; 43(4): 337-41, 1990 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-2341569

RESUMO

The findings of recent surveys indicate a need for standardisation in lymphocyte subset analysis by flow cytometry. Major areas of concern are the methods used for labelling subsets and the choice of appropriate monoclonal antibodies. A standard dual colour manual whole blood lysis technique for flow cytometry was compared with the recently available Coulter Q-Prep EPICS technique. Overall, there was no significant difference (Student's t test) between the use of anticoagulated blood treated with heparin or EDTA. When normal subjects were examined there was a decrease in the absolute number of CD3+ and Leu-7+/CD8- cells and an increase in CD19+ and CD20+ cells. When human immunodeficiency virus (HIV) antibody positive subjects were examined there was a significant decrease in the absolute number of CD2+, CD3+, CD4+ and Leu 7+/CD8- cells and an absolute increase in CD19+ and CD20+ cells. CD8+ cells were decreased only with the Cyto-Stat reagents. Occasionally, the Q-Prep did not lyse the red cells efficiently. While the Q-Prep EPICS system has the potential to standardise and automate the labelling procedures used in lymphocyte subset analysis, further refinement, such as the choice of monoclonal antibodies or alternative preparative reagents, may be required to resolve the cause of the discordant findings between the two approaches.


Assuntos
Linfócitos/citologia , Anticorpos Monoclonais , Anticoagulantes , Autoanálise , Citometria de Fluxo , Soropositividade para HIV/sangue , Humanos , Contagem de Leucócitos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...