Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Exp Clin Cancer Res ; 21(3 Suppl): 47-54, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12585654

RESUMO

The development and growth of solid tumors rely on a process known as perfusion which allows for the delivery and clearance of nutrients through their vasculature. The classical approach of studying tumor vasculature by histologic staining of endothelial cells provides a measure of microvessel density in areas of high vascularization (so-called "hot spots"). More advanced high-resolution, parametric, contrast-enhanced MRI techniques enable quantitative assessment of the vascular distribution and function over the entire tumor. Hence, MRI overcomes the intratumoral variation of the histological method. Clinical testing of the MRI approach, that evaluates the permeability and surface area of the tumor vasculature, demonstrates improved accuracy of breast cancer diagnosis.


Assuntos
Neoplasias da Mama/irrigação sanguínea , Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética , Neovascularização Patológica/diagnóstico , Meios de Contraste , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos
2.
J Magn Reson Imaging ; 13(6): 862-7, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11382945

RESUMO

The spatial resolution of three-dimensional (3D) gradient-echo T1-weighted images, from 40 women with 25 malignant and 23 benign lesions, was purposely degraded to determine the role of spatial resolution in recording, analysis, and diagnosis of dynamic contrast-enhanced breast MRI. Images were recorded and analyzed at pixel resolution according to the 3TP method (Degani et al., Nat Med 1997;3:780-782). Reduction in spatial resolution degraded the appearance of foci with fast wash-in and fast washout dynamics. This resulted in an increase in false-negative diagnoses. The sensitivity for differentiating between malignant and benign lesions, using threshold criteria defined by the 3TP analysis, of 76% decreased to 60% and 24% for a 2- and 4-fold reduction in spatial resolution, respectively, without affecting significantly the high specificity (96-100%). In order to minimize false-negative diagnoses of contrast-enhanced breast MRI and maintain high specificity, it is essential to record and analyze the dynamic behavior at high spatial resolution. J. Magn. Reson. Imaging 2001;13:862-867.


Assuntos
Neoplasias da Mama/diagnóstico , Mama/patologia , Aumento da Imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Biópsia , Doenças Mamárias/diagnóstico , Doenças Mamárias/patologia , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Ductal de Mama/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico , Carcinoma Intraductal não Infiltrante/patologia , Diagnóstico Diferencial , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Mamografia , Sensibilidade e Especificidade , Ultrassonografia Mamária
3.
AJR Am J Roentgenol ; 175(3): 705-11, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10954454

RESUMO

OBJECTIVE: The objective of this study was to compare CT and sonography for monitoring radiofrequency (RF) lesions in porcine livers. SUBJECTS AND METHODS: RF lesions (n = 12) were created in three pig livers by applying 13 min of current to a multielectrode RF probe with a target temperature of 95 degrees C. Helical unenhanced CT and corresponding axial sonography were performed before ablation, at 2 min, 8 min, and immediately after ablation. Contrast-enhanced CT was performed after ablation. CT scans and sonograms were evaluated by blinded observers for conspicuity of the RF lesion, edge detection (visibility of liver-lesion interface), and artifacts. Hounsfield units were recorded at every time interval, and radiologic-pathologic correlation for lesion size and configuration was performed. RESULTS: Mean size of RF lesions was 3. 03 +/- 0.9 cm. On CT, RF lesions had consistently lower attenuation values than surrounding liver (22.2 H lower than liver at 8 min, p < 0.0001). Echogenicity was variable with sonography (hypoechoic = 59%, hyperechoic = 25%, isoechoic = 16%). Unenhanced CT significantly improved conspicuity, edge detection of RF lesions, and decreased artifacts compared with sonography (p < 0.05). Contrast-enhanced CT improved RF lesion detection, border discrimination, and artifacts compared with sonography (p < 0.05). Unenhanced CT had the best correlation to pathologic size (r = 0.74), followed by contrast-enhanced CT (r = 0.72) and sonography (r = 0.56). Contrast-enhanced CT best correlated with lesion shape, but slightly overestimated size because of areas of ischemia peripheral to the RF lesion. CONCLUSION: In this animal model, unenhanced CT was an effective way to monitor RF ablation compared with sonography because of increased lesion discrimination, reproducible decreased attenuation during ablation, and improved correlation to pathologic size.


Assuntos
Hepatectomia/métodos , Cuidados Intraoperatórios/métodos , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Animais , Ablação por Cateter , Fígado/cirurgia , Suínos , Ultrassonografia
4.
Magn Reson Med ; 42(4): 746-53, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10502764

RESUMO

A method is presented that converts dynamic T(1)-weighted spoiled gradient-recalled echo (SGRE) image intensities into estimates of T(1) without the errors associated with imperfections in the slice profile and transmitter coil magnetic field (B(1)). The method involves T(1) measurements performed before and after a series of dynamic SGRE images. These measurements serve to calibrate and correct the SGRE signal strength equation used to estimate T(1). Simulations and phantom experiments were performed to test the method for slice-selective (two-dimensional) and slab-selective (three-dimensional) imaging, as well as for imaging performed with optimized and un-optimized B(1). For nearly all test conditions, T(1) was estimated accurately (within 10%) over a range of T(1) values expected in vivo ( approximately 1200 --> 300 msec). This method should be useful for quantifying dynamic SGRE imaging for many different applications including breast MR imaging. Magn Reson Med 42:746-753, 1999.


Assuntos
Mama/patologia , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
5.
J Magn Reson Imaging ; 7(4): 716-23, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9243393

RESUMO

The effect of keyhole data acquisition on quantitative analysis of dynamic MRI was examined. Experiments were performed retrospectively on raw data obtained from clinical dynamic contrast-enhanced breast imaging procedures. The effects of keyhole phase-encoding acquisition and type of reconstruction algorithm on the accuracy of derived quantitative parameters was assessed. Results indicate that the minimum keyhole size used should be restricted by the approximate minimum size of the expected lesions. Furthermore, reconstruction algorithms that offer improved image resolution do not circumvent this restriction.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico , Mama/patologia , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Feminino , Gadolínio , Gadolínio DTPA , Humanos , Compostos Organometálicos , Ácido Pentético/análogos & derivados , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
J Magn Reson Imaging ; 6(5): 743-52, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8890012

RESUMO

Both benign and malignant breast lesions may exhibit intense contrast enhancement when imaged using gadolinium-enhanced MRI. We propose a quantitative approach for fitting dynamic signal intensity (SI) data that may distinguish benign from malignant lesions. We studied 78 lesions in 75 women (18 malignancies, 16 fibroadenomas, and 44 other benign breast lesions) to determine the potential of this model for decreasing false-positive MR results. Twenty-eight lesions showed no enhancement; all were benign. One lesion showed a complex pattern not amenable to region-of-interest analysis and was considered a false positive. SI versus time data for the remaining 49 lesions were fit to the proposed model. We found that one parameter, M, the normalized slope of the SI enhancement profile evaluated at half the maximal signal intensity, seemed to be highly correlated with malignancy and offered improved discrimination between malignant and benign lesions compared to a previously published two-point slope method.


Assuntos
Doenças Mamárias/diagnóstico , Neoplasias da Mama/diagnóstico , Gadolínio , Imageamento por Ressonância Magnética/métodos , Carcinoma/diagnóstico , Diagnóstico Diferencial , Reações Falso-Positivas , Feminino , Fibroadenoma/diagnóstico , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Modelos Teóricos , Sensibilidade e Especificidade
7.
Acad Radiol ; 3 Suppl 3: S500-6, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8883528

RESUMO

RATIONALE AND OBJECTIVES: We compared the safety and imaging efficacy of iodixanol-270 (270 mg I/ml), iodixanol-320 (320 mg I/ml), both of which are isosmolal to blood, and iohexol-300 (300 mg I/ml) for body computed tomography (CT) scanning. METHODS: One hundred twenty-six patients from the University of Wisconsin Hospital and Temple University Hospital scheduled to undergo body CT examinations were randomly assigned to receive either iodixanol-270, iodixanol-320, or iohexol-300. Patients were monitored with questioning and vital signs before injection, immediately after injection, and at 24 and 48 hr. Extensive laboratory evaluation also was performed. RESULTS: No serious reactions or deaths occurred in any group. The occurrence of overall minor adverse events (usually warmth, headache, taste distortion, rash) was similar for the different groups. Laboratory results showed no significant difference across groups. There was no significant difference in image quality detected among groups. CONCLUSION: There was no detectable difference in safety and imaging efficacy among the three contrast groups in this study. However, patients from the University of Wisconsin experienced significantly less injection discomfort with iodixanol-270 than with iohexol-300. Large clinical studies may more definitively determine the presence and nature of the relative advantages of iodixanol compared with currently available ionic and nonionic contrast agents.


Assuntos
Meios de Contraste , Iohexol , Tomografia Computadorizada por Raios X , Ácidos Tri-Iodobenzoicos , Meios de Contraste/efeitos adversos , Método Duplo-Cego , Feminino , Humanos , Iohexol/efeitos adversos , Masculino , Pessoa de Meia-Idade , Ácidos Tri-Iodobenzoicos/efeitos adversos
8.
Acad Radiol ; 3(6): 486-92, 1996 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8796706

RESUMO

RATIONALE AND OBJECTIVES: We assessed whether intestinal ischemia would result in transudation of orally administered gadopentetate dimeglumine into the peritoneal cavity. METHODS: Twenty-eight rats were anesthetized and midline laparotomy was performed. Animals were divided into four groups: control, ligation of a single mesenteric arcade, ligation of six consecutive arcades, and ligation of the anterior mesenteric artery (analogous to the superior mesenteric artery in humans). A 1.0-ml enteric bolus of gadopentetate dimeglumine diluted with sterile water (1:1) was given via gavage. Magnetic resonance imaging was performed 2 hr after laparotomy and reviewed for the presence of intraperitoneal gadopentetate dimeglumine by two experienced observers. Animals were sacrificed 24 hr after surgery for pathologic examination. RESULTS: Four animals died prior to sacrifice. The bladder had a grossly high signal in all cases, implying some degree of intravascular absorption of the contrast material. A correlation was found between increasing mean radiology scores and increasing numbers of ligated vessels. The intraperitoneal signal tended to be higher in experimental animals than in control animals. Histologic damage was more severe in experimental animals (ischemic changes extending deeper into the intestinal wall) than in control animals. CONCLUSION: Direct visualization of spilled gastrointestinal gadopentetate dimeglumine helped discriminate ischemic from control rats in this model.


Assuntos
Meios de Contraste/administração & dosagem , Extravasamento de Materiais Terapêuticos e Diagnósticos/diagnóstico , Intestinos/irrigação sanguínea , Isquemia/diagnóstico , Imageamento por Ressonância Magnética , Meglumina/administração & dosagem , Oclusão Vascular Mesentérica/diagnóstico , Compostos Organometálicos/administração & dosagem , Ácido Pentético/análogos & derivados , Administração Oral , Animais , Permeabilidade Capilar/fisiologia , Meios de Contraste/farmacocinética , Combinação de Medicamentos , Extravasamento de Materiais Terapêuticos e Diagnósticos/patologia , Feminino , Gadolínio DTPA , Isquemia/patologia , Masculino , Meglumina/farmacocinética , Artérias Mesentéricas/patologia , Oclusão Vascular Mesentérica/patologia , Compostos Organometálicos/farmacocinética , Ácido Pentético/administração & dosagem , Ácido Pentético/farmacocinética , Ratos , Ratos Sprague-Dawley
9.
J Magn Reson Imaging ; 6(2): 300-4, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-9132095

RESUMO

Our objective was to evaluate the efficacy of MR imaging as compared with conventional hysterosalpingography (HSG) for the detection of fallopian tube patency after uterine injection of contrast material. Rabbit uterine horns (n= 18) were catheterized transvaginally. Five fallopian tubes were ligated and 11 were left unaltered. T1-weighted gradient-echo MR images were obtained before, during, and after injection of 1.0-3.0 mL of a dilute gadolinium-containing contrast agent. Corresponding conventional studies were performed with an equivalent volume of iohexol. Images were evaluated by two blinded readers. Observers agreed in all cases on the presence (n = 11) or absence (n = 5) of peritoneal spill with conventional HSG. Interpretation of MR HSG concurred with conventional HSG in 14 of 16 cases for each observer (P > .05). Reasons for misdiagnosis included small amounts of spill (n = 2), artifact (n = 1), and subtle spill between bowel loops (n = 1). Sensitivity and specificity for MR HSG were 95.5% and 70%, respectively, for the diagnosis of tubal patency/occlusions. No statistical difference was found between MR HSG and conventional HSG for the diagnosis of fallopian tube patency/obstruction. Potential advantages of MR HSG include no ionizing radiation, potentially diminished local contrast toxicity, superior visualization of uterine fibroids and endometriosis, and visualization of ovaries. We conclude that this technique warrants further study, including the use of a primate model to better simulate human anatomy.


Assuntos
Meios de Contraste , Tubas Uterinas/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Meglumina , Compostos Organometálicos , Ácido Pentético/análogos & derivados , Animais , Artefatos , Combinação de Medicamentos , Extravasamento de Materiais Terapêuticos e Diagnósticos/diagnóstico , Doenças das Tubas Uterinas/diagnóstico , Testes de Obstrução das Tubas Uterinas , Feminino , Gadolínio DTPA , Histerossalpingografia , Iohexol , Coelhos , Sensibilidade e Especificidade
10.
J Magn Reson Imaging ; 6(1): 203-12, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8851429

RESUMO

The relative populations and transverse relaxation times of the solid-like hydrogen pool (PB and T2B) and the magnetization transfer (MT) rates between the solid-like and liquid-like hydrogen pools (kappa) have been determined for three different agar gel concentrations (2%, 4%, and 8% by weight) as well as excised fibroglandular breast tissue specimens. PB was determined to be .003(.001), .01(.002), .02(.01), and .06(.01); T2B was determined to be 13.0(.2), 14.0(.1), 14.5(.1) and 15.2(1.3) microseconds; and kappa was determined to be 0.78(.01), 1.15(.02), 2.00(.02), and 3.55(1.5) sec-1 for the 2%, 4%, and 8% agar gels and the fibroglandular tissue, respectively. The image signal intensities of a pulsed MTC-prepared gradient-echo imaging technique are predicted using these MT parameters and are shown to agree well with experimental data obtained from a clinical MR imaging system. This technique is shown to suppress signal intensity of fibroglandular breast tissue by 40%-50% without exceeding SAR limits (< or = 8 W/kg) and is helpful for visualizing lesions and silicone implants.


Assuntos
Mama/patologia , Implantes de Mama , Neoplasias da Mama/diagnóstico , Feminino , Fibroadenoma/diagnóstico , Humanos , Imageamento por Ressonância Magnética/métodos , Magnetismo , Silicones
11.
Acad Radiol ; 2(6): 484-91, 1995 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9419595

RESUMO

RATIONALE AND OBJECTIVES: We conducted a pilot study to determine the potential advantages of using liver-specific targeted computed tomography (CT) contrast agents for lesion detection. METHODS: Eight dogs had liver infarcts created by percutaneous injections of ethanol. Each dog underwent CT scans with four imaging techniques: unenhanced, intravenous contrast enhanced (IVCE), CT arterial portography (CTAP), and targeted liver enhancement with iodipamide ethylester (IDE) particles. Lesions were assessed quantitatively to determine liver-to-lesion density differences and the drop in density across liver edge as a quantitative measure of edge sharpness. Expert readers subjectively analyzed data to determine lesion visibility and edge sharpness. RESULTS: Liver-to-lesion density differences were greatest with CTAP (56.4 +/- 35.5 Hounsfield units [H]) followed by IDE (41.1 +/- 7.0 H), i.v. (22.7 +/- 6.0 H), and unenhanced scans (13.6 +/- 4.1 H; ps < .05 for CTAP versus unenhanced and IDE versus unenhanced). Edges were best defined both subjectively and quantitatively on IDE-enhanced scans. CONCLUSION: Targeted liver-specific contrast agents have potential to increase lesion visibility when compared with standard i.v. contrast enhancement of the liver by increasing lesion edge definition and liver-to-lesion attenuation differences. Further work in animal tumor models, and clinical trials as agents become available, appears justified.


Assuntos
Meios de Contraste/administração & dosagem , Infarto/diagnóstico por imagem , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X , Animais , Cães , Relação Dose-Resposta a Droga , Vias de Administração de Medicamentos , Artéria Hepática , Veias Hepáticas , Iodopamida/administração & dosagem , Iodopamida/análogos & derivados , Iohexol/administração & dosagem , Projetos Piloto , Portografia , Sensibilidade e Especificidade
12.
Radiol Clin North Am ; 33(3): 581-94, 1995 May.
Artigo em Inglês | MEDLINE | ID: mdl-7740112

RESUMO

The pancreas transplant is difficult to monitor both clinically and by imaging. Complications such as thrombosis, infection, pancreatitis, bleeding, anastomotic leak, or rejection may quickly progress to transplant failure. Ultrasound, CT, MR imaging, fluoroscopy, nuclear scintigraphy, and angiography may be used to help define the etiology of transplant compromise; however, all have marked limitations, and none has proved to be the study of choice. The surgeon and radiologist must carefully coordinate clinical suspicion with the strengths of the various modalities to optimize a timely diagnosis.


Assuntos
Transplante de Pâncreas , Complicações Pós-Operatórias/diagnóstico , Humanos , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Complicações Pós-Operatórias/diagnóstico por imagem , Radiografia , Cintilografia , Ultrassonografia
13.
Crit Rev Diagn Imaging ; 36(4): 287-338, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-8845065

RESUMO

The inherent overlap in the T1 and T2 relaxation of benign and malignant breast lesions has hindered progress in the application of MRI to evaluate this organ. Indeed, lesions in a glandular breast may completely blend in with normal breast tissues, a problem unenhanced MRI shares with mammography. However, infusion of intravenous Gd-DPTA accompanied by rapid MR imaging results in successful detection of most invasive breast malignancies. Inspection of the lesion morphology and enhancement profile shows that most malignancies have an irregular border, enhance very rapidly, and display a distinct early washout phase. On the other hand, fibroadenomas have a smooth or gently lobulated border and enhance in a continuous monotonic fashion. Some pitfalls exist such as the variable enhancement associated with DCIS and premenopausal breast tissue. This publication reviews the literature with respect to Gd-enhanced breast MRI, focusing on strengths and weaknesses, and suggests appropriate indications for employing this new approach to breast imaging. Patient preparation and discussion of technical parameters and tradeoffs is also addressed. The exact place of MRI in the work-up of the breast-problem patient has yet to be settled, but already MRI can help radiologists offer a more conclusive diagnosis in mammographically perplexing situations, particularly in patients with radiographically dense breasts.


Assuntos
Mama/patologia , Meios de Contraste , Imageamento por Ressonância Magnética , Compostos Organometálicos , Ácido Pentético/análogos & derivados , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/diagnóstico por imagem , Feminino , Gadolínio DTPA , Humanos , Imageamento por Ressonância Magnética/métodos , Mamografia
14.
Magn Reson Med ; 32(1): 43-51, 1994 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8084236

RESUMO

Off-resonance spin locking is investigated as a low power method for achieving low field spin-lattice relaxation contrast using high field clinical MR imaging systems (e.g., 1.5 tesla). Spin-lattice relaxation times and equilibrium magnetizations in the off-resonance rotating frame (T1 rho(off), beta) were measured for tissue-mimicking phantom materials as a function of the ratio of the amplitude to the resonance offset of the spin-locking pulse (f1/delta). The phantom materials consisted of vegetable oil to simulate fat and two different gels containing 2% and 4% agar to simulate nonfatty tissues with different macromolecular compositions. These measurements were used to verify a signal strength equation for a multislice off-resonance spin-locking technique implemented on a clinical MR imaging system operating at 1.5 tesla. Although the oil showed little change in image contrast with increasing f1/delta, the two gels demonstrated a strong variation which provided improved discrimination compared to T1-weighted imaging. Off-resonance spin locking is suggested as a method for improving delineation of breast lesions and a preliminary clinical example from a patient volunteer is presented.


Assuntos
Neoplasias da Mama/diagnóstico , Fibroadenoma/diagnóstico , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Feminino , Humanos , Modelos Estruturais , Óleos de Plantas
15.
AJR Am J Roentgenol ; 162(2): 271-8, 1994 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8310908

RESUMO

OBJECTIVE: We evaluated a single-exposure, phosphor-plate, dual-energy imaging device that produces, in addition to conventional chest radiographs, both tissue- and bone-selective images. Our purpose was to determine whether dual-energy radiography was more accurate than routine chest radiography for detection and characterization of pulmonary nodules. SUBJECTS AND METHODS: Two hundred patients undergoing chest CT were asked to volunteer to have dual-energy and conventional chest radiographs obtained immediately before or after their CT scan. Radiographs from a subset of 50 of these patients with 116 CT-detected nodules and 10 patients with normal findings on CT scans of the chest were presented to the observers for the nodule detection study. Similarly, radiographs from a subset of 29 patients with 20 calcified and 20 uncalcified nodules were presented to five observers to determine nodule calcification. Dual-energy images were produced by filtering the X-ray tube output with a gadolinium sheet while using a multiple phosphor plate receptor. A dual-energy triad of images consisting of a conventional image, a tissue-selective image, and a bone-selective image were produced. The conventional chest radiographs and dual-energy image sets were presented to observers in random order. Data from a free response receiver operating curve and a receiver operating curve were generated for nodule detection and characterization, respectively. RESULTS: By using the dual-energy images, all five observers improved their ability to diagnose pulmonary nodules (p = .0005) and to characterize nodules as calcified (p = .005). CONCLUSION: By eliminating rib shadows with tissue-selective images and enhancing calcified structures with bone-selective images, dual-energy chest radiography improved the ability of all observers, regardless of expertise, to detect and characterize pulmonary nodules.


Assuntos
Pulmão/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Reações Falso-Positivas , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Pessoa de Meia-Idade , Variações Dependentes do Observador , Curva ROC , Costelas/diagnóstico por imagem , Nódulo Pulmonar Solitário/epidemiologia
16.
Abdom Imaging ; 18(1): 95-6, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8431701

RESUMO

A case of lymphoma of the adrenal glands is presented. Both computed tomography (CT) and magnetic resonance imaging (MRI) demonstrated large bilateral adrenal masses with no other associated abdominal abnormalities. MR was better able to demonstrate inferior vena caval patency than CT, and effectively exclude pheochromocytoma as a differential diagnostic consideration due to signal characteristics of the masses.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico , Linfoma/diagnóstico , Imageamento por Ressonância Magnética , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Humanos , Linfoma/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
17.
Radiol Clin North Am ; 30(5): 1053-66, 1992 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1518928

RESUMO

Ultrasonography of the renal transplant is still a key screening examination for transplant dysfunction. The addition of Doppler technology has permitted screening for hemodynamic alterations. Ambitious researchers predicted that these hemodynamic profiles would permit the differentiation of rejection from other complicating factors; however, recent research and clinical experience has shown this to be ineffective. Imaging identification of a dilated collecting system identifies the patient population that should undergo a Whitaker procedure. Identification of large or increasing fluid collections helps focus attention to possible hemorrhage or urine leak. Similarly, the ultrasonographic identification of a lymphocele as the cause of leg edema or hydronephrosis rapidly focuses surgical treatment. Doppler evaluation of hemodynamics must be performed on all renal transplant recipients. Although the role of the resistive index in predicting rejection has been minimized lately, numerous vascular complications, if untreated, would result in loss of the kidney. Doppler sonography identifies those patients who would benefit most from renal arteriography. The evaluation of renal morphology on the basis of ultrasonography alone has little role in predicting the cause of transplant dysfunction. We continue to evaluate renal size and to correlate it with the clinical presentation as well as resistive index to defer patients from biopsy if a more obvious cause of dysfunction is identified.


Assuntos
Transplante de Rim/diagnóstico por imagem , Humanos , Hidronefrose/diagnóstico por imagem , Rim/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Obstrução da Artéria Renal/diagnóstico por imagem , Ultrassonografia
18.
AJR Am J Roentgenol ; 158(4): 791-7, 1992 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-1546594

RESUMO

Results of studies on the accuracy of the resistive index as a predictor of acute renal transplant rejection have varied widely. Clinical evaluations are limited by the inability to control the numerous coincidental factors that affect vascular resistance. We performed a controlled study in dogs to isolate the effects of acute tubular necrosis, cyclosporine toxicity, and acute rejection on the resistive index, and to compare them with a population of normal control subjects. By doing so, we hoped to identify the patterns of change in the resistive index over time and possibly explain the wide spectrum of resistive index data reported in the literature. Resistive index, a parameter calculated from relative systolic and diastolic velocity, indicates parenchymal resistance to perfusion. Since an increase in renal length also has been reported useful in predicting rejection, we studied changes in length in each of the isolated conditions. The normal control group (four dogs) had heterotopic autotransplantation with minimal cold ischemic time. The acute tubular necrosis group (six dogs) had heterotopic autotransplantation with 1 hr of warm ischemic time. The cyclosporine toxicity group (four dogs) was allowed approximately 3 months to heal from heterotopic autotransplantation. Very high (toxic) doses of cyclosporine were then administered. The acute rejection group (five dogs) had heterotopic allografting with minimal cold ischemic time. No medications were administered. In all groups, the abnormalities induced were confirmed by biopsy. Creatinine levels were also used to monitor cyclosporine toxicity. In the normal control and acute tubular necrosis groups, resistive index increased immediately after surgery, returning to baseline within 10 days. Renal length increased slightly in both groups, but the duration of increase was longer in the acute tubular necrosis group. No significant change in resistive index or renal length was seen in the cyclosporine toxicity group. In the acute rejection group, an initial decrease in resistive index during the mild to moderate phase was followed by a rapidly progressive increase with worsening rejection. Renal length increased progressively beginning immediately after surgery. Our study determined the patterns of change in resistance and renal length over time as caused by the isolated pathologic states. Our finding that vascular resistance decreased in mild to moderate acute rejection was unexpected, since almost all the literature reports resistive index elevation. This may explain some of the conflicting results obtained in Doppler investigations of rejection. Our results on renal length reinforce the positive clinical reports of its predictive value in rejection.


Assuntos
Ciclosporina/efeitos adversos , Rejeição de Enxerto , Transplante de Rim , Necrose Tubular Aguda/diagnóstico por imagem , Rim/diagnóstico por imagem , Animais , Cães , Rim/efeitos dos fármacos , Complicações Pós-Operatórias/diagnóstico por imagem , Circulação Renal , Ultrassonografia , Resistência Vascular
19.
Magn Reson Med ; 21(1): 30-8, 1991 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1943677

RESUMO

Twenty-five MRI scans were performed on 14 patients with cadaveric pancreatic transplants to determine the role of this modality in the evaluation of transplant dysfunction. Our population included 12 normal transplants and 13 recipients with pancreatic graft dysfunction (either rejection or pancreatitis). Six of the latter patients had two or more scans permitting reassessment of the same transplant in various states of health. T1-and T2-weighted MR images were evaluated qualitatively and quantitatively to see if certain patterns were associated with clinical status. We found that although MRI was capable of producing excellent images of the in situ pancreatic transplant, this modality was unable to reliably distinguish the normal from the abnormal transplant. This conclusion differs from prior assessments; possible reasons for this are discussed.


Assuntos
Rejeição de Enxerto , Imageamento por Ressonância Magnética , Transplante de Pâncreas/patologia , Pancreatite/diagnóstico , Humanos , Transplante de Rim , Complicações Pós-Operatórias/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...