Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
2.
World J Urol ; 42(1): 487, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39158747

RESUMO

OBJECTIVE: To evaluate the stone ablation rate and direct thermal damage from thulium fiber laser (TFL) lithotripsy using continuous (C) and burst (B) lasing techniques on an in vitro ureteral model. METHODS: The TFL Drive (Coloplast, Humlebaek, Denmark) was used in an in vitro saline-submerged ureteral model. Ten participants, including five junior and five experienced urologists, conducted the experimental setup with 7 different settings comparing two lasing techniques: steady-state lasing (0.5 J/10 Hz = 5W for 300 s and 0.5 J/20 Hz = 10W for 150 s) and burst, intermittent 5 s on/off lasing (0.5 J/20 Hz, 0.5 J/30 Hz, 0.5 J/60 Hz, 0.1 J/200 Hz, and 0.05 J/400 Hz) with a target cumulative energy of 1500 J using cubic 125 mm3 phantom BegoStonesTM. Ureteral damage was graded 1-3 based on the severity of burns and holes observed on the surface of the ureteral model. RESULTS: The were no significant differences in stone ablation mass neither between C and B lasing techniques, nor between expertise levels. At C lasing technique had only mild ureteral lesions with no significant differences between expertise levels (p: 0.97) or laser settings (p: 0.71). At B lasing technique, different types of thermal lesions were found with no expertise (p: 0.11) or setting (p: 0.83) differences. However, B laser setting had higher grade direct thermal lesions than C (p: 0.048). CONCLUSION: Regarding efficacy, C and B lasing techniques achieve comparable stone ablation rates. Safety-wise, B lasing mode showed higher grade of direct thermal lesions. These results should be further investigated to verify which of the lasing mode is the safest in vivo. Until then and unless proven otherwise, a C mode with low frequency should be recommended to avoid ureteral wall lesions.


Assuntos
Litotripsia a Laser , Túlio , Litotripsia a Laser/métodos , Litotripsia a Laser/instrumentação , Humanos , Ureter/cirurgia , Cálculos Ureterais/cirurgia , Técnicas In Vitro , Lasers de Estado Sólido/uso terapêutico
3.
Urologia ; : 3915603241273885, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39212156

RESUMO

Social media (SoMe) is now a core part of modern-day life with increased use among both patients and urologists. The interplay of SoMe between these two parties is complex. From a patient perspective, SoMe platforms can serve as educational tools as well as communication portals to support networks and patient communities. However, studies report the educational value of content online is often poor and may contain misinformation. For urologists, SoMe can lead to research collaborations, networking and educational content but areas of concern include the potential negative impact SoMe can have on mental health and sharing of patient images without appropriate consent. This review serves to provide an overview of the interaction between SoMe and urology practice and provide practical guidance to navigating it.

5.
World J Urol ; 42(1): 453, 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39073430

RESUMO

PURPOSE: To examine temporal-spatial distribution of heat generated upon laser activation in a bench model of renal calyx. To establish reference values for a safety distance between the laser fiber and healthy tissue during laser lithotripsy. METHODS: We developed an in-vitro experimental setup employing a glass pipette and laser activation under various intra-operative parameters, such as power and presence of irrigation. A thermal camera was used to monitor both temporal and spatial temperature changes during uninterrupted 60-second laser activation. We computed the thermal dose according to Sapareto and Dewey's formula at different distances from the laser fiber tip, in order to determine a safety distance. RESULTS: A positive correlation was observed between average power and the highest recorded temperature (Spearman's coefficient 0.94, p < 0.001). Irrigation was found to reduce the highest recorded temperature, with a maximum average reduction of 9.4 °C at 40 W (p = 0.002). A positive correlation existed between average power and safety distance values (Spearman's coefficient 0.86, p = 0.001). A thermal dose indicative of tissue damage was observed at 20 W without irrigation (safety distance 0.93±0.11 mm). While at 40 W, irrigation led to slight reduction in mean safety distance (4.47±0.85 vs. 5.22±0.09 mm, p = 0.08). CONCLUSIONS: Laser settings with an average power greater than 10 W deliver a thermal dose indicative of tissue damage, which increases with higher average power values. According to safety distance values from this study, a maximum of 10 W should be used in the ureter, and a maximum of 20 W should be used in kidney in presence of irrigation.


Assuntos
Litotripsia a Laser , Litotripsia a Laser/métodos , Litotripsia a Laser/instrumentação , Humanos , Temperatura Alta , Cálices Renais , Irrigação Terapêutica/métodos
6.
J Endourol ; 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39078335

RESUMO

Introduction: Kidney stones in pregnant is not a common emergency, but it is one that is extremely challenging to manage. There exists no previous survey, which maps the different practice patterns adopted. Our aim was to deliver a survey to evaluate the current status of practice patterns across different parts of the world regarding the management of stone disease in pregnancy. Methods: Through an iterative process, 19-item survey was devised. This contained the following five sections: (1) Demographics, (2) General items, (3) Diagnosis and Imaging, (4) Initial management, (5) Surgery. It was disseminated via social media and email chains. Results: A total of 355 responses were collected, and the majority (66.2%) reported no established hospital protocol for stones in pregnancy. Ultrasound was the most popular first line imaging choice (89.9%) but 8% would choose non-contrast CT. The latter was also chosen as second line choicer in 34.6% as opposed to magnetic resonance imaging. A large proportion (42.5%) had requested CT in pregnancy previously. With equivocal ultra sound results, only 19.4% would proceed to ureteroscopy (URS) but 40.9% would opt for CT. Twenty-four-48 hours were the most popular (37.6%) time period to observe before surgical intervention. Ureteral stent and nephrostomy were regarded as equally effective, and 6 weeks was most popular frequency for an exchange. Most do not use fetal heart rate monitoring intraoperatively. A total of 3.94% had previously performed percutaneous nephrolithotomy during pregnancy. Conclusion: Practice patterns vary widely for suspected kidney stones in pregnancy and use of CT appears increasingly popular. This includes when faced with equivocal ultrasound results and instead of proceeding to ureteroscopy. Most hospitals lack an established management protocol for this scenario.

7.
Eur Urol ; 86(3): 198-199, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38890068

RESUMO

There is a lack of consensus on definitions for the success of endourological stone treatments. The zero-fragment rate (residual fragments [RFs] <1 mm) is now considered more accurate than the stone-free rate (RFs ≤4 mm). As stone volume may be adopted as the recommended method for preoperative estimation of the stone burden, the volumetric stone-free rate may be superior to standard linear RF measurements in defining success.


Assuntos
Ureteroscopia , Humanos , Resultado do Tratamento , Cálculos Renais/cirurgia , Urologia , Litotripsia/métodos
8.
Urology ; 191: 144-152, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38878828

RESUMO

OBJECTIVE: To conduct a systematic review (SR) of literature to assess the existing evidence concerning the success and complications of endourological ex vivo stone surgeries. METHODS: Eligible studies for inclusion focused on investigating the success and/or complications related to endourological ex vivo surgeries in donors with nephrolithiasis. A SR was undertaken in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The search included databases of Web of Science, PubMed, and Scopus and only article in English were included. Studies published between 2002 and 2023 included in this SR. RESULTS: After screening 1726 abstracts, this SR included 16 studies with a total of 209 patients. The mean stone size was 5.6 mm and majority of kidneys contained single stones, located in the lower calyx. After ex vivo endourological stone surgeries, the average stone-free rate was found to be 95.4%. The mean duration of ex vivo surgery was 17.3 minutes. Regarding intraoperative complications, two patients (1%) experienced mucosal injuries during pneumatic lithotripsy. As for postoperative complications, two patients (1%) experienced vascular complications. In terms of urological complications, hematuria was observed in 24 patients (11.5%), while one patient (0.5%) experienced clot formation in renal pelvis. Seven patients (3.3%) had urinary tract infections, and three patients (1.4%) developed urolithiasis during the follow-up. Additionally, one patient (0.5%) experienced complete occlusion of ureteroneocystostomy and required revision. CONCLUSION: Given the advancements in current technology and techniques, endourological ex vivo stone surgeries are increasingly recognized as an effective and safe option for donors with nephrolithiasis. TRIAL REGISTRATION: This systematic review was registered under the protocol registration number CRD42024538384/PROSPERO.


Assuntos
Cálculos Renais , Transplante de Rim , Humanos , Transplante de Rim/efeitos adversos , Transplante de Rim/métodos , Cálculos Renais/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Litotripsia/métodos , Litotripsia/efeitos adversos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/epidemiologia , Resultado do Tratamento
9.
Int J Impot Res ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38877106

RESUMO

Social media is increasingly used as a platform for patients to explore health care information. Our objective was to study the content on TikTok® in order to gain insight into the perspectives shared by the public on vasectomy. A search was performed using the hashtag ´#vasectomy´ on 12.20.2023 and the top 100 video posts from persons self-identifying as patients were included. Using an adaptation of a previously published system, a framework was created for organising and categorising the data related to vasectomy. Domains covered included reason for vasectomy, complications, vasectomy as a controversial topic in society and reference to the 2022 Dobbs v. Jackson ruling. Most content originated from the United States (85.0%) and the median number of views per video was 261 200 (interquartile range (IQR) 8416-1 800 000). In 12.0% of posts, the individual clearly stated that they were under 30 years of age. Two of the commonest topics to be addressed in the videos were recovery (41.0%) and pain (40.0%). 30.0% discussed the reason for undergoing vasectomy. Reasons included women's rights (12%), safety over tubal ligation (5.0%) and desire to be childless (4.0%). 9.0% referred to the Dobbs v. Jackson ruling. Complications were discussed in 19.0% including vasectomy failure (12.0%). 23.0% contained factually incorrect medical information. 31.0% of videos included the user voicing that vasectomy was considered to be a controversial subject. More than half of the videos (61.0%) were positive regarding the vasectomy process. Our findings reveal that vasectomy receives very high engagement on social media. This study confirms that patients do use it to share their experiences, both positive and negative. Misconceptions regarding this contraception method are common among the public and the urological community should work to address this.

10.
World J Urol ; 42(1): 298, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38709327

RESUMO

PURPOSE: The aim of the study was to evaluate illumination properties in an in-vitro kidney calyx model in saline. DESIGN AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed closed pink kidney calyx model, submerged in saline. A spectrometer was used for illuminance and color temperature measurements at different openings located at center (direct light), 45° (direct and indirect light) and 90°(indirect light) to the axis of the scope. RESULTS: Maximum illuminance was at the center opening for all scopes (range: 284 to 12,058 lx at 50% brightness and 454 to 11,871 lx at 100% brightness settings). The scope with the highest center illuminance (Flex-Xc) was 26 times superior to the scope with the lowest illuminance (Pusen 7.5Fr) at 100% brightness setting. For each scope, there was a peripheral illuminance drop ranging from - 43 to - 92% at 50% brightness and - 43% to - 88% at 100% brightness settings, respectively (all p < 0.01). Highest drop was for the P7 and the Pusen 9.2F. All scopes had illuminance skew, except the V3. All scopes had a warm color temperature. CONCLUSION: Illumination properties vary between ureteroscopes in an enclosed cavity in saline, and differs at center vs 45° and 90° positions within scopes. Peripheral illuminance drop can be as high as - 92%, which is undesirable. This may affect the choice of ureteroscope and light brightness settings used in surgery by urologists.


Assuntos
Desenho de Equipamento , Rim , Iluminação , Ureteroscópios , Modelos Anatômicos , Humanos
11.
World J Urol ; 42(1): 294, 2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38704777

RESUMO

PURPOSE: To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout and whiteout occurrences in an in-vitro kidney calyx model. MATERIAL AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed enclosed pink in-vitro kidney calyx model submerged in saline. Endoscopic images were captured with ureteroscope tip placed at 5 mm,10 mm and 20 mm distances. The complete range of brightness settings and video capture modes were evaluated for each scope. Distribution of brightness on a grayscale histogram of images was analyzed (scale range 0 to 255). Blackout and whiteout were defined as median histogram ranges from 0 to 35 and 220 to 255, respectively (monitor image too dark or too bright for the human eye, respectively). RESULTS: Blackout occurred with the P7, Pusen 7.5F, 9.2F and WiScope at all distances, and V3 at 20 mm - with lowest brightness settings. Whiteout occurred with Flex-X2s, V3 and P7 at 5 mm and 10 mm, as well as with V3 and P7 at 20 mm - mostly with highest brightness settings. The Flex-Xc had neither blackout nor whiteout at all settings and distances. CONCLUSION: Blackout or whiteout of images is an undesirable property that was found for several scopes, possibly impacting diagnostic and therapeutic purposes during ureteroscopy. These observations form a guide to impact a urologist's choice of instruments and settings.


Assuntos
Ureteroscópios , Ureteroscopia , Humanos , Desenho de Equipamento , Iluminação , Maleabilidade , Cálices Renais
12.
World J Urol ; 42(1): 292, 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38704492

RESUMO

PURPOSE: During endoscopic stone surgery, Holmium:YAG (Ho:YAG) and Thulium Fiber Laser (TFL) technologies allow to pulverize urinary stones into fine particles, ie DUST. Yet, currently there is no consensus on the exact definition of DUST. This review aimed to define stone DUST and Clinically Insignificant Residual Fragments (CIRF). METHODS: Embase, MEDLINE (PubMed) and Cochrane databases were searched for both in vitro and in vivo articles relating to DUST and CIRF definitions, in November 2023, using keyword combinations: "dust", "stones", "urinary calculi", "urolithiasis", "residual fragments", "dusting", "fragments", "lasers" and "clinical insignificant residual fragments". RESULTS: DUST relates to the fine pulverization of urinary stones, defined in vitro as particles spontaneously floating with a sedimentation duration ≥ 2 sec and suited for aspiration through a 3.6Fr-working channel (WC) of a flexible ureteroscope (FURS). Generally, an upper size limit of 250 µm seems to agree with the definition of DUST. Ho:YAG with and without "Moses Technology", TFL and the recent pulsed-Thulium:YAG (pTm:YAG) can produce DUST, but no perioperative technology can currently measure DUST size. The TFL and pTm:YAG achieve better dusting compared to Ho:YAG. CIRF relates to residual fragments (RF) that are not associated with imminent stone-related events: loin pain, acute renal colic, medical or interventional retreatment. CIRF size definition has decreased from older studies based on Shock Wave Lithotripsy (SWL) (≤ 4 mm) to more recent studies based on FURS (≤ 2 mm) and Percutaneous Nephrolithotomy(PCNL) (≤ 4 mm). RF ≤ 2 mm are associated with lower stone recurrence, regrowth and clinical events rates. While CIRF should be evaluated postoperatively using Non-Contrast Computed Tomography(NCCT), there is no consensus on the best diagnostic modality to assess the presence and quantity of DUST. CONCLUSION: DUST and CIRF refer to independent entities. DUST is defined in vitro by a stone particle size criteria of 250 µm, translating clinically as particles able to be fully aspirated through a 3.6Fr-WC without blockage. CIRF relates to ≤ 2 RF on postoperative NCCT.


Assuntos
Ureteroscopia , Cálculos Urinários , Humanos , Cálculos Urinários/terapia , Litotripsia a Laser/métodos , Poeira , Tamanho da Partícula
13.
Turk J Med Sci ; 54(1): 185-193, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38812627

RESUMO

Background/aim: Management of asymptomatic kidney stones is an ongoing debate with follow-up and treatment guidelines based on low-level evidence. Our aim was to evaluate current management of asymptomatic urinary stones. Materials and methods: A 70-question survey was designed in collaboration with European Association of Urology, Young Academic Urologists, Section of Uro-Technology and Section of Urolithiasis groups and distributed. Responders filled out hypothetical scenarios from 2 perspectives, either as treating physicians, or as patients themselves. Results: A total of 212 (40.01%) responses were obtained. Median responder age was 39 years. 75% of responders were interested in "urolithiasis". 82.5% had never experienced a renal colic, 89.6% had never undergone urolithiasis treatment.Overall, as the kidney stone scenarios got more complicated, the invasiveness of the treatment preference increased. As "the physician", responders preferred the conservative option in all situations more than they would choose as "the patient". For ureteral stones, conservative approach was most preferred for small stones and ureteroscopy became more preferred as the stone size increased.For smaller kidney stones, the most preferred follow-up schedule was 4-6 monthly, whereas for larger and complicated stones it was 0-3 monthly from both perspectives respectively. For all ureteral stone scenarios, 0-4 weekly follow-up was mostly preferred.Interestingly, having had a renal colic was an independent predictor of an interventional approach, whereas having had an intervention was an independent predictor of a conservative approach. Conclusion: Current treatment and follow-up patterns of asymptomatic urinary stones are in agreement with international guidelines on symptomatic stones.In most of the urolithiasis situations urologists chose a conservative approach for their patients compared to what they would prefer for themselves. Conversely, urologists, in the scenarios as "the patient", would like to have a more frequent follow-up schedule for their stones compared to how they would follow-up their patients.


Assuntos
Urologistas , Humanos , Adulto , Inquéritos e Questionários , Masculino , Feminino , Urologia , Cálculos Renais/terapia , Ureteroscopia , Padrões de Prática Médica/estatística & dados numéricos , Urolitíase/terapia , Pessoa de Meia-Idade , Europa (Continente) , Atitude do Pessoal de Saúde , Doenças Assintomáticas/terapia
14.
World J Urol ; 42(1): 355, 2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38796790

RESUMO

PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.


Assuntos
Desenho de Equipamento , Iluminação , Ureteroscópios , Ureteroscopia , Luz , Humanos , Solução Salina , Cor
15.
World J Urol ; 42(1): 277, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38691160

RESUMO

PURPOSE: To prospectively evaluate the rate and associated risk factors of early infectious complications after ureterorenoscopy for urolithiasis. METHODS: After ethical committee approval, 400 therapeutic retrograde ureterorenoscopy procedures between August 3, 2020 and November 24, 2021 were included for analysis in a single-center study. Postoperative infection was defined as an afebrile urinary tract infection, fever (≥ 38 °C) with pyuria (≥ 300 WBC/µL) or proven urinary pathogen, and urosepsis. The primary outcome was the rate of infectious complications after ureterorenoscopy. Secondary outcomes were the perioperative factors that increased the risk of infectious complications within 30 days of surgery using univariate and multivariate logistic regression analysis. RESULTS: Twenty-nine of four hundred (7.3%) patients developed an infectious complication within 30 days after ureterorenoscopy. Ten (2.5%) patients developed an afebrile urinary tract infection, eight (2.0%) developed fever with pyuria, five (1.3%) febrile urinary tract infection, and six (1.5%) urosepsis. On univariate analysis, preoperative stent-type JFil® pigtail suture stent was significantly associated with the dependent variable (p < 0.001). On multivariate logistic regression analysis, older age (OR 1.035; 95% CI 1.006-1.070; p = 0.02) was found to be significantly associated with developing a postoperative infectious complication. CONCLUSIONS: A 7.3% rate of postoperative infectious complications and 1.5% urosepsis rate were observed after therapeutic ureterorenoscopy, without the need of intensive care admission. The only significant risk factors were preoperative stent type (JFil® pigtail suture stent) on univariate analysis, and older age on multivariate logistic regression analysis. Further multicentric prospective observational data are needed in this field.


Assuntos
Complicações Pós-Operatórias , Ureteroscopia , Infecções Urinárias , Humanos , Masculino , Feminino , Estudos Prospectivos , Fatores de Risco , Ureteroscopia/efeitos adversos , Pessoa de Meia-Idade , Infecções Urinárias/epidemiologia , Infecções Urinárias/etiologia , Adulto , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Idoso , Fatores de Tempo , Sepse/etiologia , Sepse/epidemiologia , Urolitíase/cirurgia
16.
World J Urol ; 42(1): 310, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38722553

RESUMO

INTRODUCTION: Ionizing radiation is used daily during endourological procedures. Despite the dangers of both deterministic and stochastic effects of radiation, there is a lack of knowledge and awareness among urologists. This study reviewed the literature to identify the radiation exposure (RE) of urologists during endourological procedures. METHODS: A literature search of the Medline, Web of Science, and Google Scholar databases was conducted to collect articles related to the radiation dose to urologists during endourological procedures. A total of 1966 articles were screened. 21 publications met the inclusion criteria using the PRIMA standards. RESULTS: Twenty-one studies were included, of which 14 were prospective. There was a large variation in the mean RE to the urologist between studies. PCNL had the highest RE to the urologist, especially in the prone position. RE to the eyes and hands was highest in prone PCNL, compared to supine PCNL. Wearing a thyroid shield and lead apron resulted in a reduction of RE ranging between 94.1 and 100%. Educational courses about the possible dangers of radiation decreased RE and increased awareness among endourologists. CONCLUSIONS: This is the first systematic review in the literature analyzing RE to urologists over a time period of more than four decades. Wearing protective garments such as lead glasses, a thyroid shield, and a lead apron are essential to protect the urologist from radiation. Educational courses on radiation should be encouraged to further reduce RE and increase awareness on the harmful effects of radiation, as the awareness of endourologists is currently very low.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Urologistas , Humanos , Urologia , Procedimentos Cirúrgicos Urológicos
17.
World J Urol ; 42(1): 266, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38676726

RESUMO

PURPOSE: Considering the existing gaps in the literature regarding patient radiation dose (RD) and its associated risks, a systematic review of the literature on RD was conducted, focusing on percutaneous nephrolithotomy (PCNL), extracorporeal shock wave lithotripsy (SWL), and ureteroscopy (URS). METHODS: Two authors conducted a literature search on PubMed, Web of Science, and Google Scholar to identify studies on RD during endourological procedures. Two thousand two hundred sixty-six articles were screened. Sixty-five publications met the inclusion criteria using the PRISMA standards. RESULTS: RD was generally highest for PCNL, reaching levels up to 33 mSv, 28,700 mGycm2, and 430.8 mGy. This was followed by SWL, with RD reaching up to 7.32 mSv, 13,082 mGycm2, and 142 mGy. URS demonstrated lower RD, reaching up to 6.07 mSv, 8920 mGycm2, and 46.99 mGy. Surgeon experience and case load were inversely associated with RD. Strategies such as optimizing fluoroscopy settings, implementing ultrasound (US), and following the ALARA (As Low As Reasonably Achievable) principle minimized RD. CONCLUSIONS: This is the first systematic review analyzing RD, which was generally highest during PCNL, followed by SWL and URS. There is no specific RD limit for these procedures. Implementation of strategies such as optimizing fluoroscopy settings, utilizing US, and adhering to the ALARA principle proved effective in reducing RD. However, further research is needed to explore the factors influencing RD, assess their impact on patient outcomes, and establish procedure-specific reference levels for RD.


Assuntos
Litotripsia , Nefrolitotomia Percutânea , Exposição à Radiação , Ureteroscopia , Humanos , Ureteroscopia/efeitos adversos , Nefrolitotomia Percutânea/efeitos adversos , Nefrolitotomia Percutânea/métodos , Litotripsia/efeitos adversos , Litotripsia/métodos , Doses de Radiação
18.
Eur Urol Open Sci ; 63: 4-12, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38558765

RESUMO

Background and objective: Prostate-specific antigen (PSA) remains a critical marker for prostate cancer (PCa) detection and monitoring. Recognising historical variability in PSA assays and the evolution of assay technology and calibration, this study aims to reassess interassay variability using the latest generation of five assays in a contemporary cohort of men undergoing prostate biopsy. Methods: Five different commercially available PSA assays were tested in a blood sample of 76 men before undergoing a prostate biopsy. Total PSA (tPSA) and free-to-total PSA ratio (%fPSA) were compared across assays, using Roche (Basel, Switzerland) as the benchmark, and correlated with biopsy outcome to analyse the impact on PCa diagnosis. The statistical analysis included Passing-Bablok regression and Bland-Altman plots, with a p value threshold of <0.05 for significance. Key findings and limitations: Among the 76 men, 28 (36.8%) were diagnosed with significant PCa (defined as International Society of Urological Pathology grade ≥2). A high correlation was observed between tPSA and %fPSA values among the different PSA assays tested (r2 ≥ 0.9). The Passing-Bablok analysis showed that tPSA results varied substantially among the assays, with slopes ranging between 0.78 and 1.04. Compared with the tPSA of Roche, tPSA values were on average 20.7% lower by Beckman (Oststeinbeck, Germany), 15.2% lower by Abbott (Chicago, IL, USA), 6.1% lower by Diasorin (Saluggia, Italy), and 9.6% higher by Brahms (Hennigsdorf, Germany; p < 0.001 for all). The %fPSA values by Abbott and Brahms were higher at 15.7% and 10.6%, respectively (p < 0.001), while the Beckman and Diasorin values had minimal differences of -0.3% and 2.3%, respectively (p > 0.05). The variability across assays would have resulted in discrepancies in both the sensitivity and the specificity for tPSA and %fPSA by at least 14%, depending on the cut-offs applied. Conclusions and clinical implications: Despite the use of the latest PSA assays, relevant variability of tPSA and %fPSA results can be observed among different assays. There is an urgent need for standardised calibration methods and greater awareness among practitioners concerning interassay variability. Clinicians should acknowledge that clinically relevant thresholds may depend on the specific PSA assay and that ideally the same assay is applied over time for better clinical decision-making. Patient summary: Prostate-specific antigen (PSA) is a critical marker for prostate cancer (PCa) detection and monitoring. However, significant variations were observed in the results of the latest PSA assays. Thus, standardised calibration methods and greater awareness among practitioners concerning interassay variability are needed.

19.
World J Urol ; 42(1): 240, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630158

RESUMO

PURPOSE: To evaluate the impact of ureteroscope position within renal cavities as well as different locations of the tip of the ureteral access sheath (UAS) on fluid dynamics during retrograde intrarenal surgery (RIRS). MATERIALS AND METHODS: A prospective observational clinical study was performed. Measurements with a flexible ureteroscope placed in the upper, middle and lower calyces were obtained with the tip of the UAS placed either 2 cm below the pyelo-ureteric junction (PUJ), or at the level of the iliac crest. RESULTS: 74 patients were included. The outflow rates from the middle and upper calyxes were statistically significantly higher compared to the lower calyx, both with the UAS close to the pyelo-ureteric junction and at the iliac crest. When the UAS was withdrawn and positioned at the level of the iliac crest, a significant decrease in outflow rates from the upper (40.1 ± 4.3 ml/min vs 35.8 ± 4.1 ml/min) and middle calyces (40.6 ± 4.0 ml/min vs 36.8 ± 4.6 ml/min) and an increase in the outflow from the lower calyx (28.5 ± 3.3 ml/min vs 33.7 ± 5.7 ml/min) were noted. CONCLUSIONS: Our study showed that higher fluid outflow rates are observed from upper and middle calyces compared to lower calyx. This was true when the UAS was positioned 2 cm below the PUJ and at the iliac crest. Significant worsening of fluid dynamics from upper and middle calyces was observed when the UAS was placed distally at the level of the iliac crest. While the difference was statistically significant, the absolute change was not significant. In contrast, for lower calyces, a statistically significant improvement was documented.


Assuntos
Ureter , Ureteroscópios , Humanos , Hidrodinâmica , Rim , Endoscopia , Ureter/cirurgia
20.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520528

RESUMO

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Assuntos
Iluminação , Ureteroscópios , Humanos , Desenho de Equipamento , Urologistas , Equipamentos Descartáveis , Ureteroscopia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA