Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 289
Filtrar
1.
ESC Heart Fail ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38715187

RESUMO

AIMS: Patients with a reduced left ventricular ejection fraction (LVEF) following an acute myocardial infarction (MI) are at risk of progressive adverse cardiac remodelling that can lead to the development of heart failure and death. The early addition of a sodium-glucose cotransporter 2 (SGLT2) inhibitor to standard treatment may delay or prevent progressive adverse remodelling in these patients. METHODS AND RESULTS: EMpagliflozin to PREvent worSening of left ventricular volumes and Systolic function after Myocardial Infarction (EMPRESS-MI) is a randomized, double-blind, placebo-controlled, multi-centre trial designed to assess the effect of empagliflozin on cardiac remodelling evaluated using cardiovascular magnetic resonance (CMR) in 100 patients with left ventricular systolic dysfunction following MI. Eligible patients were those ≥12 h and ≤14 days following acute MI, with an LVEF <45% by CMR. Patients were randomized to empagliflozin 10 mg once a day or matching placebo. The primary outcome will be change in left ventricular end-systolic volume indexed to body surface area over 24 weeks from randomization. Secondary endpoints include measures of left ventricular and atrial volumes, left ventricular mass, LVEF, and circulating cardiac biomarkers. CONCLUSIONS: EMPRESS-MI will assess the effect of the SGLT2 inhibitor empagliflozin on cardiac remodelling in patients with left ventricular systolic dysfunction after an acute MI.

3.
Lancet ; 403(10436): 1543-1553, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38604209

RESUMO

BACKGROUND: The coronary sinus reducer (CSR) is proposed to reduce angina in patients with stable coronary artery disease by improving myocardial perfusion. We aimed to measure its efficacy, compared with placebo, on myocardial ischaemia reduction and symptom improvement. METHODS: ORBITA-COSMIC was a double-blind, randomised, placebo-controlled trial conducted at six UK hospitals. Patients aged 18 years or older with angina, stable coronary artery disease, ischaemia, and no further options for treatment were eligible. All patients completed a quantitative adenosine-stress perfusion cardiac magnetic resonance scan, symptom and quality-of-life questionnaires, and a treadmill exercise test before entering a 2-week symptom assessment phase, in which patients reported their angina symptoms using a smartphone application (ORBITA-app). Patients were randomly assigned (1:1) to receive either CSR or placebo. Both participants and investigators were masked to study assignment. After the CSR implantation or placebo procedure, patients entered a 6-month blinded follow-up phase in which they reported their daily symptoms in the ORBITA-app. At 6 months, all assessments were repeated. The primary outcome was myocardial blood flow in segments designated ischaemic at enrolment during the adenosine-stress perfusion cardiac magnetic resonance scan. The primary symptom outcome was the number of daily angina episodes. Analysis was done by intention-to-treat and followed Bayesian methodology. The study is registered with ClinicalTrials.gov, NCT04892537, and completed. FINDINGS: Between May 26, 2021, and June 28, 2023, 61 patients were enrolled, of whom 51 (44 [86%] male; seven [14%] female) were randomly assigned to either the CSR group (n=25) or the placebo group (n=26). Of these, 50 patients were included in the intention-to-treat analysis (24 in the CSR group and 26 in the placebo group). 454 (57%) of 800 imaged cardiac segments were ischaemic at enrolment, with a median stress myocardial blood flow of 1·08 mL/min per g (IQR 0·77-1·41). Myocardial blood flow in ischaemic segments did not improve with CSR compared with placebo (difference 0·06 mL/min per g [95% CrI -0·09 to 0·20]; Pr(Benefit)=78·8%). The number of daily angina episodes was reduced with CSR compared with placebo (OR 1·40 [95% CrI 1·08 to 1·83]; Pr(Benefit)=99·4%). There were two CSR embolisation events in the CSR group, and no acute coronary syndrome events or deaths in either group. INTERPRETATION: ORBITA-COSMIC found no evidence that the CSR improved transmural myocardial perfusion, but the CSR did improve angina compared with placebo. These findings provide evidence for the use of CSR as a further antianginal option for patients with stable coronary artery disease. FUNDING: Medical Research Council, Imperial College Healthcare Charity, National Institute for Health and Care Research Imperial Biomedical Research Centre, St Mary's Coronary Flow Trust, British Heart Foundation.


Assuntos
Angina Estável , Doença da Artéria Coronariana , Seio Coronário , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Doença da Artéria Coronariana/terapia , Angina Estável/tratamento farmacológico , Seio Coronário/diagnóstico por imagem , Teorema de Bayes , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Método Duplo-Cego , Isquemia , Adenosina
6.
J Am Coll Cardiol ; 83(11): 1042-1055, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38385929

RESUMO

BACKGROUND: Ventricular arrhythmia in hypertrophic cardiomyopathy (HCM) relates to adverse structural change and genetic status. Cardiovascular magnetic resonance (CMR)-guided electrocardiographic imaging (ECGI) noninvasively maps cardiac structural and electrophysiological (EP) properties. OBJECTIVES: The purpose of this study was to establish whether in subclinical HCM (genotype [G]+ left ventricular hypertrophy [LVH]-), ECGI detects early EP abnormality, and in overt HCM, whether the EP substrate relates to genetic status (G+/G-LVH+) and structural phenotype. METHODS: This was a prospective 211-participant CMR-ECGI multicenter study of 70 G+LVH-, 104 LVH+ (51 G+/53 G-), and 37 healthy volunteers (HVs). Local activation time (AT), corrected repolarization time, corrected activation-recovery interval, spatial gradients (GAT/GRTc), and signal fractionation were derived from 1,000 epicardial sites per participant. Maximal wall thickness and scar burden were derived from CMR. A support vector machine was built to discriminate G+LVH- from HV and low-risk HCM from those with intermediate/high-risk score or nonsustained ventricular tachycardia. RESULTS: Compared with HV, subclinical HCM showed mean AT prolongation (P = 0.008) even with normal 12-lead electrocardiograms (ECGs) (P = 0.009), and repolarization was more spatially heterogenous (GRTc: P = 0.005) (23% had normal ECGs). Corrected activation-recovery interval was prolonged in overt vs subclinical HCM (P < 0.001). Mean AT was associated with maximal wall thickness; spatial conduction heterogeneity (GAT) and fractionation were associated with scar (all P < 0.05), and G+LVH+ had more fractionation than G-LVH+ (P = 0.002). The support vector machine discriminated subclinical HCM from HV (10-fold cross-validation accuracy 80% [95% CI: 73%-85%]) and identified patients at higher risk of sudden cardiac death (accuracy 82% [95% CI: 78%-86%]). CONCLUSIONS: In the absence of LVH or 12-lead ECG abnormalities, HCM sarcomere gene mutation carriers express an aberrant EP phenotype detected by ECGI. In overt HCM, abnormalities occur more severely with adverse structural change and positive genetic status.


Assuntos
Cardiomiopatia Hipertrófica , Cicatriz , Humanos , Estudos Prospectivos , Cicatriz/patologia , Imagem Cinética por Ressonância Magnética , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/genética , Eletrocardiografia , Hipertrofia Ventricular Esquerda/diagnóstico , Imageamento por Ressonância Magnética
7.
medRxiv ; 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38410488

RESUMO

Background: Regadenoson is used to induce hyperemia in cardiac imaging, facilitating diagnosis of ischemia and assessment of coronary flow reserve (CFR). While the regadenoson package insert recommends administration of radionuclide tracer 10-20 seconds after injection, peak hyperemia has been observed at approximately 100 seconds after injection in healthy volunteers undergoing cardiovascular magnetic resonance imaging (CMR). It is unclear when peak hyperemia occurs in a patient population. Objectives: The goal of this study was to determine time to peak hyperemia after regadenoson injection in healthy volunteers and patients, and whether the recommended image timing in the package insert underestimates CFR. Methods: Healthy volunteers (n=15) and patients (n=25) underwent stress CMR, including phase-contrast imaging of the coronary sinus at rest and multiple timepoints after 0.4 mg regadenoson injection. Coronary sinus flow (ml/min) was divided by resting values to yield CFR. Smoothed, time-resolved curves for CFR were generated with pointwise 95% confidence intervals. Results: CFR between 60 and 120 seconds was significantly higher than CFR at 30 seconds after regadenoson injection (p < 0.05) as shown by non-overlapping 95% confidence intervals for both healthy volunteers (30 s, [2.8, 3.4]; 60 s, [3.8, 4.4]; 90 s, [4.1, 4.7]; 120 s, [3.6, 4.3]) and patients (30 s, [2.1, 2.5]; 60 s, [2.6, 3.1]; 90 s, [2.7, 3.2]; 120 s, [2.5, 3.1]). Conclusion: Imaging at 90 seconds following regadenoson injection is the optimal approach to capture peak hyperemia. Imaging at 30 seconds, which is more aligned with the package insert recommendation, would yield an underestimate of CFR and confound assessment of microvascular dysfunction.

8.
J Cardiovasc Magn Reson ; 26(1): 101007, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38316344

RESUMO

BACKGROUND: Quantitative cardiovascular magnetic resonance (CMR) first pass perfusion maps are conventionally acquired with 3 short-axis (SAX) views (basal, mid, and apical) in every heartbeat (3SAX/1RR). Thus, a significant part of the left ventricle (LV) myocardium, including the apex, is not covered. The aims of this study were 1) to investigate if perfusion maps acquired with 3 short-axis views sampled every other RR-interval (2RR) yield comparable quantitative measures of myocardial perfusion (MP) as 1RR and 2) to assess if acquiring 3 additional perfusion views (i.e., total of 6) every other RR-interval (2RR) increases diagnostic confidence. METHODS: In 287 patients with suspected ischemic heart disease stress and rest MP were performed on clinical indication on a 1.5T MR scanner. Eighty-three patients were examined by acquiring 3 short-axis perfusion maps with 1RR sampling (3SAX/1RR); for which also 2RR maps were reconstructed. Additionally, in 103 patients 3 short-axis and 3 long-axis (LAX; 2-, 3, and 4-chamber view) perfusion maps were acquired using 2RR sampling (3SAX + 3LAX/2RR) and in 101 patients 6 short-axis perfusion maps using 2RR sampling (6SAX/2RR) were acquired. The diagnostic confidence for ruling in or out stress-induced ischemia was scored according to a Likert scale (certain ischemia [2 points], probably ischemia [1 point], uncertain [0 points], probably no ischemia [1 point], certain no ischemia [2 points]). RESULTS: There was a strong correlation (R = 0.99) between 3SAX/1RR and 3SAX/2RR for global MP (mL/min/g). The diagnostic confidence score increased significantly when the number of perfusion views was increased from 3 to 6 (1.24 ± 0.68 vs 1.54 ± 0.64, p < 0.001 with similar increase for 3SAX+3LAX/2RR (1.29 ± 0.68 vs 1.55 ± 0.65, p < 0.001) and for 6SAX/2RR (1.19 ± 0.69 vs 1.53 ± 0.63, p < 0.001). CONCLUSION: Quantitative perfusion mapping with 2RR sampling of data yields comparable perfusion values as 1RR sampling, allowing for the acquisition of additional views within the same perfusion scan. The diagnostic confidence for stress-induced ischemia increases when adding 3 additional views, short- or long axes, to the conventional 3 short-axis views. Thus, future development and clinical implementation of quantitative CMR perfusion should aim at increasing the LV coverage from the current standard using 3 short-axis views.

9.
EuroIntervention ; 20(3): e216-e223, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38214677

RESUMO

The coronary sinus Reducer (CSR) is an hourglass-shaped device which creates an artificial stenosis in the coronary sinus. Whilst placebo-controlled data show an improvement in angina, these results are unreplicated and are the subject of further confirmatory research. The mechanism of action of this unintuitive therapy is unknown. The Coronary Sinus Reducer Objective Impact on Symptoms, MRI Ischaemia, and Microvascular Resistance (ORBITA-COSMIC) trial is a randomised, placebo-controlled, double-blind trial investigating the efficacy of the CSR. Patients with (i) established epicardial coronary artery disease, (ii) angina on maximally tolerated antianginal medication, (iii) evidence of myocardial ischaemia and (iv) no further options for percutaneous coronary intervention or coronary artery bypass grafting will be enrolled. Upon enrolment, angina and quality-of-life questionnaires, treadmill exercise testing and quantitative stress perfusion cardiac magnetic resonance (CMR) imaging will be performed. Participants will record their symptoms daily on a smartphone application throughout the trial. After a 2-week symptom assessment phase, participants will be randomised in the cardiac catheterisation laboratory to CSR or a placebo procedure. After 6 months of blinded follow-up, all prerandomisation tests will be repeated. A prespecified subgroup will undergo invasive coronary physiology assessment at prerandomisation and follow-up. The primary outcome is stress myocardial blood flow on CMR. Secondary outcomes include angina frequency, quality of life and treadmill exercise time. (ClinicalTrials.gov: NCT04892537).


Assuntos
Angina Estável , Doença da Artéria Coronariana , Seio Coronário , Intervenção Coronária Percutânea , Humanos , Angina Estável/diagnóstico , Qualidade de Vida , Seio Coronário/cirurgia , Resultado do Tratamento , Doença da Artéria Coronariana/terapia
10.
Eur J Heart Fail ; 2024 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-38247182

RESUMO

AIMS: Cardiac involvement is the main driver of clinical outcomes in systemic amyloidosis and preliminary studies support the hypothesis that myocardial ischaemia contributes to cellular damage. The aims of this study were to assess the presence and mechanisms of myocardial ischaemia using cardiovascular magnetic resonance (CMR) with multiparametric mapping and histopathological assessment. METHODS AND RESULTS: Ninety-three patients with cardiac amyloidosis (CA) (light-chain amyloidosis n = 42, transthyretin amyloidosis n = 51) and 97 without CA (three-vessel coronary disease [3VD] n = 47, unobstructed coronary arteries n = 26, healthy volunteers [HV] n = 24) underwent quantitative stress perfusion CMR with myocardial blood flow (MBF) mapping. Twenty-four myocardial biopsies and three explanted hearts with CA were analysed histopathologically. Stress MBF was severely reduced in patients with CA with lower values than patients with 3VD, unobstructed coronary arteries and HV (CA: 1.04 ± 0.51 ml/min/g, 3VD: 1.35 ± 0.50 ml/min/g, unobstructed coronary arteries: 2.92 ± 0.52 ml/min/g, HV: 2.91 ± 0.73 ml/min/g; CA vs. 3VD p = 0.011, CA vs. unobstructed coronary arteries p < 0.001, CA vs. HV p < 0.001). Myocardial perfusion abnormalities correlated with amyloid burden, systolic and diastolic function, structural parameters and blood biomarkers (p < 0.05). Biopsies demonstrated abnormal vascular endothelial growth factor staining in cardiomyocytes and endothelial cells, which may be related to hypoxia conditions. Amyloid infiltration in intramural arteries was associated with severe lumen reduction and severe reduction in capillary density. CONCLUSION: Cardiac amyloidosis is associated with severe inducible myocardial ischaemia demonstrable by histology and CMR stress perfusion mapping. Histological evaluation indicates a complex pathophysiology, where in addition to systolic and diastolic dysfunction, amyloid infiltration of the epicardial arteries and disruption and rarefaction of the capillaries play a role in contributing to myocardial ischaemia.

11.
Arthritis Rheumatol ; 76(1): 100-106, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37488949

RESUMO

OBJECTIVE: To describe a 41-year-old woman with a history of neonatal onset multisystem inflammatory disease, on treatment with daily subcutaneous injections of 600 mg of recombinant interleukin-1 receptor antagonist (IL-1Ra) protein, anakinra, since the age of 28, who presented with golf-ball size nodules at the anakinra injection sites, early satiety, new onset nephrotic syndrome in the context of normal markers of systemic inflammation. METHODS: Clinical history and histologic evaluation of biopsies of skin, gastric mucosa, and kidney with Congo-red staining and proteomic evaluation of microdissected Congo red-positive amyloid deposits by liquid chromatography-tandem mass spectrometry. RESULTS: The skin, stomach, and kidney biopsies all showed the presence of Congo red-positive amyloid deposits. Mass spectrometry-based proteomics demonstrated that the amyloid deposits in all sites were of AIL1RAP (IL-1Ra protein)-type. These were characterized by high spectral counts of the amyloid signature proteins (apolipoprotein AIV, apolipoprotein E, and serum amyloid P-component) and the amyloidogenic IL-1Ra protein, which were present in Congo red-positive areas and absent in Congo red-negative areas. The amino acid sequence identified by mass spectrometry confirmed that the amyloid precursor protein was recombinant IL-1Ra (anakinra) and not endogenous wild-type IL-1Ra. CONCLUSION: This is the first report of iatrogenic systemic amyloidosis due to an injectable protein drug, which was caused by recombinant IL1Ra (anakinra).


Assuntos
Amiloidose , Proteína Antagonista do Receptor de Interleucina 1 , Feminino , Recém-Nascido , Humanos , Adulto , Proteína Antagonista do Receptor de Interleucina 1/uso terapêutico , Placa Amiloide , Vermelho Congo/química , Proteômica , Amiloidose/metabolismo , Amiloidose/patologia
12.
Magn Reson Med ; 91(4): 1637-1644, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38041477

RESUMO

PURPOSE: Guidelines recommend measuring myocardial extracellular volume (ECV) using T1 -mapping before and 10-30 min after contrast agent administration. Data are then analyzed using a linear model (LM), which assumes fast water exchange (WX) between the ECV and cardiomyocytes. We investigated whether limited WX influences ECV measurements in patients with severe aortic stenosis (AS). METHODS: Twenty-five patients with severe AS and 5 healthy controls were recruited. T1 measurements were made on a 3 T Siemens system using a multiparametric saturation-recovery single-shot acquisition (a) before contrast; (b) 4 min post 0.05 mmol/kg gadobutrol; and (c) 4 min, (d) 10 min, and (e) 30 min after an additional gadobutrol dose (0.1 mmol/kg). Three LM-based ECV estimates, made using paired T1 measurements (a and b), (a and d), and (a and e), were compared to ECV estimates made using all 5 T1 measurements and a two-site exchange model (2SXM) accounting for WX. RESULTS: Median (range) ECV estimated using the 2SXM model was 25% (21%-39%) for patients and 26% (22%-29%) for controls. ECV estimated in patients using the LM at 10 min following a cumulative contrast dose of 0.15 mmol/kg was 21% (17%-32%) and increased significantly to 22% (19%-35%) at 30 min (p = 0.0001). ECV estimated using the LM was highest following low dose gadobutrol, 25% (19%-38%). CONCLUSION: Current guidelines on contrast agent dose for ECV measurements may lead to underestimated ECV in patients with severe AS because of limited WX. Use of a lower contrast agent dose may mitigate this effect.


Assuntos
Estenose da Valva Aórtica , Compostos Organometálicos , Humanos , Meios de Contraste , Miocárdio , Valor Preditivo dos Testes , Estenose da Valva Aórtica/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética
13.
Artigo em Inglês | MEDLINE | ID: mdl-38083374

RESUMO

Real-time cine cardiac MRI provides an ECG-free free-breathing alternative to clinical gold-standard ECG-gated breath-hold segmented cine MRI for evaluation of heart function. Real-time cine MRI data acquisition during free breathing snapshot imaging enables imaging of patient cohorts that cannot be imaged with segmented or breath-hold acquisitions, but requires rapid imaging to achieve sufficient spatial-temporal resolutions. However, at high acceleration rates, conventional reconstruction techniques suffer from residual aliasing and temporal blurring, including advanced methods such as compressed sensing with radial trajectories. Recently, deep learning (DL) reconstruction has emerged as a powerful tool in MRI. However, its utility for free-breathing real-time cine MRI has been limited, as database-learning of spatio-temporal correlations with varying breathing and cardiac motion patterns across subjects has been challenging. Zero-shot self-supervised physics-guided deep learning (PG-DL) reconstruction has been proposed to overcome such challenges of database training by enabling subject-specific training. In this work, we adapt zero-shot PG-DL for real-time cine MRI with a spatio-temporal regularization. We compare our method to TGRAPPA, locally low-rank (LLR) regularized reconstruction and database-trained PG-DL reconstruction, both for retrospectively and prospectively accelerated datasets. Results on highly accelerated real-time Cartesian cine MRI show that the proposed method outperforms other reconstruction methods, both visibly in terms of noise and aliasing, and quantitatively.


Assuntos
Aprendizado Profundo , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Estudos Retrospectivos , Interpretação de Imagem Assistida por Computador/métodos , Coração/diagnóstico por imagem
14.
J Cardiovasc Magn Reson ; 25(1): 73, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38044439

RESUMO

BACKGROUND: Electrocardiographic imaging (ECGI) generates electrophysiological (EP) biomarkers while cardiovascular magnetic resonance (CMR) imaging provides data about myocardial structure, function and tissue substrate. Combining this information in one examination is desirable but requires an affordable, reusable, and high-throughput solution. We therefore developed the CMR-ECGI vest and carried out this technical development study to assess its feasibility and repeatability in vivo. METHODS: CMR was prospectively performed at 3T on participants after collecting surface potentials using the locally designed and fabricated 256-lead ECGI vest. Epicardial maps were reconstructed to generate local EP parameters such as activation time (AT), repolarization time (RT) and activation recovery intervals (ARI). 20 intra- and inter-observer and 8 scan re-scan repeatability tests. RESULTS: 77 participants were recruited: 27 young healthy volunteers (HV, 38.9 ± 8.5 years, 35% male) and 50 older persons (77.0 ± 0.1 years, 52% male). CMR-ECGI was achieved in all participants using the same reusable, washable vest without complications. Intra- and inter-observer variability was low (correlation coefficients [rs] across unipolar electrograms = 0.99 and 0.98 respectively) and scan re-scan repeatability was high (rs between 0.81 and 0.93). Compared to young HV, older persons had significantly longer RT (296.8 vs 289.3 ms, p = 0.002), ARI (249.8 vs 235.1 ms, p = 0.002) and local gradients of AT, RT and ARI (0.40 vs 0.34 ms/mm, p = 0,01; 0.92 vs 0.77 ms/mm, p = 0.03; and 1.12 vs 0.92 ms/mm, p = 0.01 respectively). CONCLUSION: Our high-throughput CMR-ECGI solution is feasible and shows good reproducibility in younger and older participants. This new technology is now scalable for high throughput research to provide novel insights into arrhythmogenesis and potentially pave the way for more personalised risk stratification. CLINICAL TRIAL REGISTRATION: Title: Multimorbidity Life-Course Approach to Myocardial Health-A Cardiac Sub-Study of the MRC National Survey of Health and Development (NSHD) (MyoFit46). National Clinical Trials (NCT) number: NCT05455125. URL: https://clinicaltrials.gov/ct2/show/NCT05455125?term=MyoFit&draw=2&rank=1.


Assuntos
Coração , Imageamento por Ressonância Magnética , Idoso , Feminino , Humanos , Masculino , Estudos de Viabilidade , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Adulto , Pessoa de Meia-Idade
15.
Artigo em Inglês | MEDLINE | ID: mdl-37831014

RESUMO

BACKGROUND: There is no acceptable maximum wall thickness (MWT) threshold for diagnosing apical hypertrophic cardiomyopathy (ApHCM), with guidelines referring to ≥15 mm MWT for all hypertrophic cardiomyopathy subtypes. A normal myocardium naturally tapers apically; a fixed diagnostic threshold fails to account for this. Using cardiac magnetic resonance, "relative" ApHCM has been described with typical electrocardiographic features, loss of apical tapering, and cavity obliteration but also with MWT <15 mm. OBJECTIVES: The authors aimed to define normal apical wall thickness thresholds in healthy subjects and use these to accurately identify ApHCM. METHODS: The following healthy subjects were recruited: healthy UK Biobank imaging substudy subjects (n = 4,112) and an independent healthy volunteer group (n = 489). A clinically defined disease population of 104 ApHCM subjects was enrolled, with 72 overt (MWT ≥15 mm) and 32 relative (MWT <15 mm but typical electrocardiographic/imaging findings) ApHCM subjects. Cardiac magnetic resonance-derived MWT was measured in 16 segments using a published clinically validated machine learning algorithm. Segmental normal reference ranges were created and indexed (for age, sex, and body surface area), and diagnostic performance was assessed. RESULTS: In healthy cohorts, there was no clinically significant age-related difference for apical wall thickness. There were sex-related differences, but these were not clinically significant after indexing to body surface area. Therefore, segmental reference ranges for apical hypertrophy required indexing to body surface area only (not age or sex). The upper limit of normal (the largest of the 4 apical segments measured) corresponded to a maximum apical MWT in healthy subjects of 5.2 to 5.6 mm/m2 with an accuracy of 0.94 (the unindexed equivalent being 11 mm). This threshold was categorized as abnormal in 99% (71/72) of overt ApHCM patients, 78% (25/32) of relative ApHCM patients, 3% (122/4,112) of UK Biobank subjects, and 3% (13/489) of healthy volunteers. CONCLUSIONS: Per-segment indexed apical wall thickness thresholds are highly accurate for detecting apical hypertrophy, providing confidence to the reader to diagnose ApHCM in those not reaching current internationally recognized criteria.

16.
Circulation ; 148(15): 1138-1153, 2023 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-37746744

RESUMO

BACKGROUND: Type 2 diabetes (T2D) is associated with an increased risk of left ventricular dysfunction after aortic valve replacement (AVR) in patients with severe aortic stenosis (AS). Persistent impairments in myocardial energetics and myocardial blood flow (MBF) may underpin this observation. Using phosphorus magnetic resonance spectroscopy and cardiovascular magnetic resonance, this study tested the hypothesis that patients with severe AS and T2D (AS-T2D) would have impaired myocardial energetics as reflected by the phosphocreatine to ATP ratio (PCr/ATP) and vasodilator stress MBF compared with patients with AS without T2D (AS-noT2D), and that these differences would persist after AVR. METHODS: Ninety-five patients with severe AS without coronary artery disease awaiting AVR (30 AS-T2D and 65 AS-noT2D) were recruited (mean, 71 years of age [95% CI, 69, 73]; 34 [37%] women). Thirty demographically matched healthy volunteers (HVs) and 30 patients with T2D without AS (T2D controls) were controls. One month before and 6 months after AVR, cardiac PCr/ATP, adenosine stress MBF, global longitudinal strain, NT-proBNP (N-terminal pro-B-type natriuretic peptide), and 6-minute walk distance were assessed in patients with AS. T2D controls underwent identical assessments at baseline and 6-month follow-up. HVs were assessed once and did not undergo 6-minute walk testing. RESULTS: Compared with HVs, patients with AS (AS-T2D and AS-noT2D combined) showed impairment in PCr/ATP (mean [95% CI]; HVs, 2.15 [1.89, 2.34]; AS, 1.66 [1.56, 1.75]; P<0.0001) and vasodilator stress MBF (HVs, 2.11 mL min g [1.89, 2.34]; AS, 1.54 mL min g [1.41, 1.66]; P<0.0001) before AVR. Before AVR, within the AS group, patients with AS-T2D had worse PCr/ATP (AS-noT2D, 1.74 [1.62, 1.86]; AS-T2D, 1.44 [1.32, 1.56]; P=0.002) and vasodilator stress MBF (AS-noT2D, 1.67 mL min g [1.5, 1.84]; AS-T2D, 1.25 mL min g [1.22, 1.38]; P=0.001) compared with patients with AS-noT2D. Before AVR, patients with AS-T2D also had worse PCr/ATP (AS-T2D, 1.44 [1.30, 1.60]; T2D controls, 1.66 [1.56, 1.75]; P=0.04) and vasodilator stress MBF (AS-T2D, 1.25 mL min g [1.10, 1.41]; T2D controls, 1.54 mL min g [1.41, 1.66]; P=0.001) compared with T2D controls at baseline. After AVR, PCr/ATP normalized in patients with AS-noT2D, whereas patients with AS-T2D showed no improvements (AS-noT2D, 2.11 [1.79, 2.43]; AS-T2D, 1.30 [1.07, 1.53]; P=0.0006). Vasodilator stress MBF improved in both AS groups after AVR, but this remained lower in patients with AS-T2D (AS-noT2D, 1.80 mL min g [1.59, 2.0]; AS-T2D, 1.48 mL min g [1.29, 1.66]; P=0.03). There were no longer differences in PCr/ATP (AS-T2D, 1.44 [1.30, 1.60]; T2D controls, 1.51 [1.34, 1.53]; P=0.12) or vasodilator stress MBF (AS-T2D, 1.48 mL min g [1.29, 1.66]; T2D controls, 1.60 mL min g [1.34, 1.86]; P=0.82) between patients with AS-T2D after AVR and T2D controls at follow-up. Whereas global longitudinal strain, 6-minute walk distance, and NT-proBNP all improved after AVR in patients with AS-noT2D, no improvement in these assessments was observed in patients with AS-T2D. CONCLUSIONS: Among patients with severe AS, those with T2D demonstrate persistent abnormalities in myocardial PCr/ATP, vasodilator stress MBF, and cardiac contractile function after AVR; AVR effectively normalizes myocardial PCr/ATP, vasodilator stress MBF, and cardiac contractile function in patients without T2D.


Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus Tipo 2 , Implante de Prótese de Valva Cardíaca , Humanos , Feminino , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Diabetes Mellitus Tipo 2/complicações , Função Ventricular Esquerda/fisiologia , Vasodilatadores , Trifosfato de Adenosina , Implante de Prótese de Valva Cardíaca/efeitos adversos
17.
Sci Rep ; 13(1): 14640, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-37669972

RESUMO

Left ventricular fibrosis can be identified by late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) in some veteran athletes. We aimed to investigate prevalence of ventricular fibrosis in veteran athletes and associations with cardiac arrhythmia. 50 asymptomatic male endurance athletes were recruited. They underwent CMR imaging including volumetric analysis, bright blood (BB) and dark blood (DB) LGE, motion corrected (MOCO) quantitative stress and rest perfusion and T1/T2/extracellular volume mapping. Athletes underwent 12-lead electrocardiogram (ECG) and 24-h ECG. Myocardial fibrosis was identified in 24/50 (48%) athletes. All fibrosis was mid-myocardial in the basal-lateral left ventricular wall. Blood pressure was reduced in athletes without fibrosis compared to controls, but not athletes with fibrosis. Fibrotic areas had longer T2 time (44 ± 4 vs. 40 ± 2 ms, p < 0.0001) and lower rest myocardial blood flow (MBF, 0.5 ± 0.1 vs. 0.6 ± 0.1 ml/g/min, p < 0.0001). On 24-h ECG, athletes with fibrosis had greater burden of premature ventricular beats (0.3 ± 0.6 vs. 0.05 ± 0.2%, p = 0.03), with higher prevalence of ventricular couplets and triplets (33 vs. 8%, p = 0.02). In veteran endurance athletes, myocardial fibrosis is common and associated with an increased burden of ventricular ectopy. Possible mechanisms include inflammation and blood pressure. Further studies are needed to establish whether fibrosis increases risk of malignant arrhythmic events.


Assuntos
Complexos Ventriculares Prematuros , Veteranos , Humanos , Masculino , Meios de Contraste , Gadolínio , Doença do Sistema de Condução Cardíaco
18.
Am Heart J ; 265: 213-224, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37657593

RESUMO

BACKGROUND: Coronary microvascular dysfunction may cause myocardial ischemia with no obstructive coronary artery disease (INOCA). If functional testing is not performed INOCA may pass undetected. Stress perfusion cardiovascular MRI (CMR) quantifies myocardial blood flow (MBF) but the clinical utility of stress CMR in the management of patients with suspected angina with no obstructive coronary arteries (ANOCA) is uncertain. OBJECTIVES: First, to undertake a diagnostic study using stress CMR in patients with ANOCA following invasive coronary angiography and, second, in a nested, double-blind, randomized, controlled trial to assess the effect of disclosure on the final diagnosis and health status in the longer term. DESIGN: All-comers referred for clinically indicated coronary angiography for the investigation of suspected coronary artery disease will be screened in 3 regional centers in the United Kingdom. Following invasive coronary angiography, patients with ANOCA who provide informed consent will undergo noninvasive endotyping using stress CMR within 3 months of the angiogram. DIAGNOSTIC STUDY: Stress perfusion CMR imaging to assess the prevalence of coronary microvascular dysfunction and clinically significant incidental findings in patients with ANOCA. The primary outcome is the between-group difference in the reclassification rate of the initial diagnosis based on invasive angiography versus the final diagnosis after CMR imaging. RANDOMIZED, CONTROLLED TRIAL: Participants will be randomized to inclusion (intervention group) or exclusion (control group) of myocardial blood flow to inform the final diagnosis. The primary outcome of the clinical trial is the mean within-subject change in the Seattle Angina Questionnaire summary score (SAQSS) at 6 months. Secondary outcome assessments include the EUROQOL EQ-5D-5L questionnaire, the Brief Illness Perception Questionnaire (Brief-IPQ), the Treatment Satisfaction Questionnaire (TSQM-9), the Patient Health Questionnaire-4 (PHQ-4), the Duke Activity Status Index (DASI), the International Physical Activity Questionnaire- Short Form (IPAQ-SF), the Montreal Cognitive Assessment (MOCA) and the 8-item Productivity Cost Questionnaire (iPCQ). Health and economic outcomes will be assessed using electronic healthcare records. VALUE: To clarify if routine stress perfusion CMR imaging reclassifies the final diagnosis in patients with ANOCA and whether this strategy improves symptoms, health-related quality of life and health economic outcomes. CLINICALTRIALS: GOV: NCT04805814.

19.
Open Heart ; 10(2)2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37586847

RESUMO

OBJECTIVE: To characterise cardiac remodelling, exercise capacity and fibroinflammatory biomarkers in patients with aortic stenosis (AS) with and without diabetes, and assess the impact of diabetes on outcomes. METHODS: Patients with moderate or severe AS with and without diabetes underwent echocardiography, stress cardiovascular magnetic resonance (CMR), cardiopulmonary exercise testing and plasma biomarker analysis. Primary endpoint for survival analysis was a composite of cardiovascular mortality, myocardial infarction, hospitalisation with heart failure, syncope or arrhythmia. Secondary endpoint was all-cause death. RESULTS: Diabetes (n=56) and non-diabetes groups (n=198) were well matched for age, sex, ethnicity, blood pressure and severity of AS. The diabetes group had higher body mass index, lower estimated glomerular filtration rate and higher rates of hypertension, hyperlipidaemia and symptoms of AS. Biventricular volumes and systolic function were similar, but the diabetes group had higher extracellular volume fraction (25.9%±3.1% vs 24.8%±2.4%, p=0.020), lower myocardial perfusion reserve (2.02±0.75 vs 2.34±0.68, p=0.046) and lower percentage predicted peak oxygen consumption (68%±21% vs 77%±17%, p=0.002) compared with the non-diabetes group. Higher levels of renin (log10renin: 3.27±0.59 vs 2.82±0.69 pg/mL, p<0.001) were found in diabetes. Multivariable Cox regression analysis showed diabetes was not associated with cardiovascular outcomes, but was independently associated with all-cause mortality (HR 2.04, 95% CI 1.05 to 4.00; p=0.037). CONCLUSIONS: In patients with moderate-to-severe AS, diabetes is associated with reduced exercise capacity, increased diffuse myocardial fibrosis and microvascular dysfunction, but not cardiovascular events despite a small increase in mortality.


Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus , Humanos , Tolerância ao Exercício , Renina , Estenose da Valva Aórtica/diagnóstico por imagem , Coração
20.
Pacing Clin Electrophysiol ; 46(9): 1077-1084, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37594233

RESUMO

BACKGROUND: The use of left bundle branch area pacing (LBBAP) for bradycardia pacing and cardiac resynchronization is increasing, but implants are not always successful. We prospectively studied consecutive patients to determine whether septal scar contributes to implant failure. METHODS: Patients scheduled for bradycardia pacing or cardiac resynchronization therapy were prospectively enrolled. Recruited patients underwent preprocedural scar assessment by cardiac MRI with late gadolinium enhancement imaging. LBBAP was attempted using a lumenless lead (Medtronic 3830) via a transeptal approach. RESULTS: Thirty-five patients were recruited: 29 male, mean age 68 years, 10 ischemic, and 16 non-ischemic cardiomyopathy. Pacing indication was bradycardia in 26% and cardiac resynchronization in 74%. The lead was successfully deployed to the left ventricular septum in 30/35 (86%) and unsuccessful in the remaining 5/35 (14%). Septal late gadolinium enhancement was significantly less extensive in patients where left septal lead deployment was successful, compared those where it was unsuccessful (median 8%, IQR 2%-18% vs. median 54%, IQR 53%-57%, p < .001). CONCLUSIONS: The presence of septal scar appears to make it more challenging to deploy a lead to the left ventricular septum via the transeptal route. Additional implant tools or alternative approaches may be required in patients with extensive septal scar.


Assuntos
Septo Interventricular , Humanos , Masculino , Idoso , Septo Interventricular/diagnóstico por imagem , Bradicardia , Cicatriz , Meios de Contraste , Gadolínio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...