Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Acta Paediatr ; 107(12): 2066-2070, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30192405

RESUMO

AIM: Corrective ventilation strategies (CVS) during neonatal resuscitation and stabilisation (R&S) are taught through the MRSOPA mnemonic: Mask adjustment, Repositioning airway, Suctioning, Opening the mouth, Increasing inspiratory Pressure, and Alternative airway. The aim was to examine the use of CVS and to investigate the relationship between MRSOPA strategies and intubation of very preterm infants <32 weeks' gestation in the delivery room. METHODS: Retrospective review of video recordings of R&S of preterm infants born in Cork University Maternity Hospital, Ireland. RESULTS: In 46 resuscitation recordings, mask adjustment was observed in almost all (95.6%), followed by suctioning, (23.9%), opening the mouth (100%), increasing inspiratory pressure (81.0%) and intubation (32.6%). The most frequently used mask holds were: one-handed (95.6%), two-handed (63.0%), stem hold (23.8%), and modified spider hold (6.5%). There were no significant associations between individual mask holds and intubation. The more CVS employed the greater the need for intubation. CONCLUSION: The greater the number of MRSOPA strategies used in the delivery room, the more likely intubation occurred. Further studies may identify the effect of these CVS on short- and long-term outcomes, in order to enhance R&S training and clinical practice.


Assuntos
Recém-Nascido Prematuro , Respiração Artificial/métodos , Algoritmos , Salas de Parto , Feminino , Humanos , Recém-Nascido , Masculino , Estudos Retrospectivos
2.
J Pediatr ; 182: 74-78.e2, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27939108

RESUMO

OBJECTIVE: To compare the ability of qualitative versus quantitative methods of end-tidal carbon dioxide (EtCO2) detection to maintain normocarbia during face mask ventilation (FMV) of preterm infants (<32 weeks) in the delivery room. STUDY DESIGN: Preterm infants <32 weeks were randomly assigned to the use of a disposable PediCap EtCO2 detector (Covidien, Dublin, Ireland) (qualitative) or a Microstream side stream capnography device (Covidien) (quantitative) for FMV in the delivery room, via a NeoPuff T-piece resuscitator (Fisher and Paykel, Auckland, New Zealand). The primary outcome was the presence of normocarbia, based on partial pressure of CO2 (PaCO2) readings obtained in the neonatal intensive care unit within an hour of birth. Normocarbia was defined as a PaCO2 measure between 37.5 and 60 mm Hg (5-8 kPa). RESULTS: Of the 59 infants included, 59% (35/59) were within the PaCO2 target range within an hour of birth. There was no difference in the primary outcome; 64% (21/33) of infants in the quantitative group were within the PaCO2 range compared with 54% (14/26) in the qualitative group (P = .594); and 93% of participants <28 weeks' gestation were within the PaCO2 normocarbic range (90% [9/10] in quantitative group and 100% [5/5] in the qualitative group [P = 1]). There was no difference in the intubation rate, days of ventilation, or bronchopulmonary dysplasia rates between the 2 groups. CONCLUSIONS: Quantitative or qualitative EtCO2 detection methods are both feasible for FMV in the delivery room. Although there was no difference in the incidence of normocarbia, the use of either form of EtCO2 monitoring should be considered during newborn stabilization, especially in infants less than 28 weeks' gestation. TRIAL REGISTRATION: ISRCTN: ISRCTN10934870.


Assuntos
Capnografia/métodos , Dióxido de Carbono/análise , Respiração Artificial/métodos , Salas de Parto , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Irlanda , Masculino , Máscaras , Estudos Prospectivos
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 3614-3617, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28324991

RESUMO

Babies born prematurely can develop brain injury within days after birth. Early identification of high-risk infants enables appropriate clinical care to mitigate potential lifelong disabilities. Near infra-red spectroscopy is an established technology that can provide continuous measurements of cerebral oxygen saturation (rcSO2) over this critical period. We develop a feature set of the rcSO2 signal for the purpose of detecting brain injury. Our feature set contains amplitude, spectral, and fractal dimension features within 5 frequency bands. Features are combined in a support vector machine (SVM) and performance is assessed within a cross-validation procedure. Using a cohort of 47 infants of <;32 weeks of gestation, we find significant (p <; 0.05) features of amplitude in the frequency band 0.9-3.6 mHz and a fractal dimension measure in the frequency band 1.8-3.6 mHz. The SVM has an area-under the receiver operator characteristic (AUC) of 0.75 with sensitivity-specificity values of 67-77%. These moderate results highlight the potential for quantitative analysis of rcSO2 to detect brain injury and thus enable early identification of high-risk infants.


Assuntos
Lesões Encefálicas/diagnóstico , Doenças do Prematuro/diagnóstico , Recém-Nascido Prematuro , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Estudos de Coortes , Idade Gestacional , Humanos , Recém-Nascido , Oxigênio/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Máquina de Vetores de Suporte
4.
Arch Dis Child Fetal Neonatal Ed ; 101(1): F62-5, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26304459

RESUMO

OBJECTIVES: To determine the feasibility of end tidal (EtCO2) monitoring of preterm infants in the delivery room, to determine EtCO2 levels during delivery room stabilisation, and to examine the incidence of normocapnia (5-8 kPa) on admission to the neonatal intensive care unit in the EtCO2 monitored group compared with a historical cohort without EtCO2 monitoring. PATIENTS AND METHODS: Preterm infants (<32 weeks) were eligible for inclusion in this observational study. The evolution of EtCO2 values immediately after delivery was assessed and linear least-squares methods were used to fit a line to EtCO2 recordings. The partial pressure of CO2 in blood (PCO2) from the infants who received EtCO2 monitoring was compared with a historical cohort without EtCO2 monitoring. RESULTS: EtCO2 monitoring was feasible in the delivery room. EtCO2 values were successfully obtained in 39 (88.7%) of the 44 infants included in the study. EtCO2 gradually increased over the first 4 min. Intubated infants had higher EtCO2 values compared with infants who were not intubated, with median (IQR) values of 4.7 (3.3-8.4) kPa versus 3.2 (2.6-4.2) kPa (p=0.05). No difference was found between the proportions of PCO2 values within the range of normocapnia among infants who received EtCO2 monitoring compared with those who did not (56.8% vs 47.9%, p=0.396). CONCLUSIONS: Delivery room EtCO2 monitoring is feasible and safe. EtCO2 values obtained after birth reflect the establishment of functional residual capacity and effective ventilation. The potential short-term and long-term consequences of EtCO2 monitoring should be established in randomised controlled trials.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/métodos , Dióxido de Carbono/sangue , Salas de Parto , Estudos de Viabilidade , Feminino , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Masculino
5.
J Pediatr ; 167(5): 1007-12.e1, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26387011

RESUMO

OBJECTIVES: To explore regional cerebral oxygen saturations (rcSO2) in preterm neonates initially stabilized with 0.3 fractionated inspired oxygen (FiO2) concentrations. We hypothesized that those infants who received >0.3 FiO2 during stabilization following delivery would have relatively higher rcSO2 postdelivery compared with those stabilized with a lower FiO2. STUDY DESIGN: A single center prospective observational study of 47 infants born before 32 weeks. Using near infrared spectroscopy, rcSO2 values were recorded immediately after birth. All preterm infants were initially given 0.3 FiO2 and were divided into 2 groups according to subsequent FiO2 requirements of either ≤0.3 or >0.3 FiO2. Using a mixed-effects model, we compared the difference between the groups over time. Also, the area measures below 55% (hypoxia) and above 85% (hyperoxia) were compared between the groups. RESULTS: The mean (SD) gestation was 29.4 (1.6) weeks and the mean (SD) weight was 1.3 (0.4) kg. Less than one-half of the infants (20/45; 43%) required ≤0.3 FiO2. In the delivery suite, the median (IQR) rcSO2 in the low and high FiO2 groups were 81% (66%-86%) and 72% (62%-86%), respectively. Patients in the high FiO2 group had a larger rcSO2 area below 55% (P = .01). There was a significant difference in rcSO2 between the groups (P < .05), with the low group having higher rcSO2 values initially, but this difference changed over time. In the neonatal intensive care unit (NICU), rcSO2 values were lower by 7.1% (CI 12.13 to 2.06%) P = .008 in the high FiO2 group. CONCLUSIONS: Infants given >0.3 FiO2 had more cerebral hypoxia than infants requiring ≤0.3 FiO2 but no difference in the degree of cerebral hyperoxia, both in the delivery suite and the NICU. This suggests that a more rapid increase in oxygen titration maybe be required initially for preterm infants.


Assuntos
Circulação Cerebrovascular , Oxigênio/uso terapêutico , Respiração Artificial/efeitos adversos , Peso ao Nascer , Encéfalo/patologia , Feminino , Idade Gestacional , Humanos , Hiperóxia , Hipóxia , Recém-Nascido , Recém-Nascido Prematuro , Terapia Intensiva Neonatal , Masculino , Oximetria/métodos , Estudos Prospectivos , Espectroscopia de Luz Próxima ao Infravermelho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA