1.
Anal Chem ; 94(35): 12008-12015, 2022 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-36001409

RESUMO

As a highly deployed field instrument for the detection of narcotics, explosives, and chemical warfare agents, drift tube ion mobility spectrometry relies heavily upon the performance of the ionization source and mechanism of ion beam modulation. For this instrumental platform, ion chemistry plays a critical role in the performance of the instrument from a sensitivity and selectivity perspective; however, a range of instrumental components also occupy pivotal roles. Most notably, the mechanism of ion modulation or ion gating is a primary contributor to peak width in a drift tube ion mobility experiment. Unfortunately, physical ion gates rarely perform perfectly, and in addition to serving as physical impediments to ion transmission, their modulation also has undesirable field effects. Using a recently developed modulated, non-radioactive X-ray source, we detail the performance of an ion mobility spectrometry (IMS) system that is free of a gating structure and utilizes the pulsed nature of the modulated X-ray source (MXS) for both ion generation and initiation of the IMS experiment. After investigating the influence of pulse duration and spatial X-ray beam width on the analytical performance of the instrument, the possibility of using multiplexing with a shutterless system is explored. By increasing ion throughput, the observed multiplexing gain compared to a signal-averaged spectrum approaches the theoretical maximum and illustrates the capability of the MXS-IMS system to realize significant signal to noise improvements.


Assuntos
Substâncias Explosivas , Espectrometria de Mobilidade Iônica , Substâncias Explosivas/análise , Espectrometria de Mobilidade Iônica/métodos , Raios X
2.
Sci Rep ; 8(1): 14195, 2018 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-30242169

RESUMO

Computed tomography (CT) is used to diagnose many emergent medical conditions, including stroke and traumatic brain injuries. Unfortunately, the size, weight, and expense of CT systems make them largely inaccessible for patients outside of major hospitals. We have designed a module containing multiple miniature x-ray sources that could allow for CT systems to be significantly lighter, smaller, and cheaper, and to operate without any moving parts. We have developed a novel photocathode-based x-ray source, created by depositing a thin film of magnesium on an electron multiplier. When illuminated by a UV LED, this photocathode emits a beam of electrons, with a beam current of up to 1 mA. The produced electrons are accelerated through a high voltage to a tungsten target. These sources are individually addressable and can be pulsed rapidly, through electronic control of the LEDs. Seven of these sources are housed together in a 17.5 degree arc within a custom vacuum manifold. A full ring of these modules could be used for CT imaging. By pulsing the sources in series, we are able to demonstrate x-ray tomosynthesis without any moving parts. With a clinical flat-panel detector, we demonstrate 3D acquisition and reconstructions of a cadaver swine lung.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Animais , Elétrons , Humanos , Imagens de Fantasmas , Suínos , Raios X