Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 424
Filtrar
2.
J Soc Cardiovasc Angiogr Interv ; 3(7): 102143, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39131994

RESUMO

Background: We aimed to perform a meta-analysis of randomized trials comparing long-term outcomes of patients undergoing transcatheter aortic valve replacement (TAVR) vs surgical aortic valve replacement (SAVR) for severe aortic stenosis. The short-term efficacy and safety of TAVR are proven, but long-term outcomes are unclear. Methods: We included randomized controlled trials comparing TAVR vs SAVR at the longest available follow-up. The primary end point was death or disabling stroke. Secondary end points were all-cause mortality, cardiac mortality, stroke, pacemaker implantation, valve thrombosis, valve gradients, and moderate-to-severe paravalvular leaks. The study is registered with PROSPERO (CRD42023481856). Results: Seven trials (N = 7785 patients) were included. Weighted mean trial follow-up was 5.76 ± 0.073 years. Overall, no significant difference in death or disabling stroke was observed with TAVR vs SAVR (HR, 1.02; 95% CI, 0.93-1.11; P = .70). Mortality risks were similar. TAVR resulted in higher pacemaker implantation and moderate-to-severe paravalvular leaks compared to SAVR. Results were consistent across different surgical risk profiles. As compared to SAVR, self-expanding TAVR had lower death or stroke risk (P interaction = .06), valve thrombosis (P interaction = .06), and valve gradients (P interaction < .01) but higher pacemaker implantation rates than balloon-expandable TAVR (P interaction < .01). Conclusions: In severe aortic stenosis, the long-term mortality or disabling stroke risk of TAVR is similar to SAVR, but with higher risk of pacemaker implantation, especially with self-expanding valves. As compared with SAVR, the relative reduction in death or stroke risk and valve thrombosis was greater with self-expanding than with balloon-expandable valves.

3.
Cardiovasc Revasc Med ; 65: 81-87, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38472025

RESUMO

Coronary artery calcification (CAC) severity is associated with increased vessel inflammation, atherosclerosis, stent failure, and risk of percutaneous coronary intervention-related complications. Current modalities for CAC modification include atherectomy techniques (rotational, orbital, and laser) and balloon modification (cutting and scoring). However, these methods are limited by their risk of slow flow/no reflow, coronary dissection, perforation, and myocardial infarction. Intravascular lithotripsy (IVL) emits high-energy sonic waves that induce calcium fractures within a target lesion to improve vessel compliance for stent placement. Low rates of major cardiac adverse events (MACE) and high rates of procedural and angiographic success were observed with IVL in the Disrupt CAD I-IV trials. Optical coherence tomography sub-studies identified calcium fracture as the likely etiology of improved vessel compliance and increased luminal diameter post-IVL. Rates of MACE, procedural, and angiographic success were consistent across the Disrupt CAD trials, suggesting IVL is less operator-dependent compared to other calcium-modifying techniques. Coronary IVL offers interventional cardiologists a safe and effective method of severe CAC modification, while providing reproducible outcomes.


Assuntos
Doença da Artéria Coronariana , Litotripsia , Índice de Gravidade de Doença , Calcificação Vascular , Humanos , Litotripsia/efeitos adversos , Calcificação Vascular/terapia , Calcificação Vascular/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Resultado do Tratamento , Fatores de Risco , Angiografia Coronária , Masculino , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia
4.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38552656

RESUMO

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Cardiovasc Revasc Med ; 64: 1-4, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38355340

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) faces anatomical challenges, currently limiting widespread adoption. OBJECTIVES: To describe the natural history and prognosis of patients ineligible for various TMVR devices. METHODS: During a 4-year period (2019-2023) 3 TMVR devices (SAPIEN M3, Intrepid and Alta Valve) became available at a single institution (The Christ Hospital, Cincinnati, OH) in the setting of pivotal clinical trials or early feasibility study. Consenting patients who were deemed ineligible ≥1 of these trials were prospectively studied to capture anatomical reasons for ineligibility, cross-over to alternative mitral valve therapies (surgery or high-risk mitral transcatheter edge to edge repair [M-TEER]), and clinical events. RESULTS: A total of 61 patients (out of 71 consenting patients or 85.9 %) were deemed ineligible for TMVR during the study period. The mean age was 79.2 ± 8.8 years, 65.6 % were female, with elevated surgical risk (median STS 4.3, IQR: 2.7-7.3). The 2 most common anatomical reasons for ineligibility were increased risk of left ventricular outflow tract obstruction (LVOTO) (n = 24, 39.3 %) and annular size (n = 29, 47.5 %). During follow-up (median 277 [162-555] days) there were 7 deaths (11.5 %) and 12 (19.7 %) hospitalizations for heart failure. Management strategies included high-risk M-TEER in 11 patients (1 death [9.0 %], 0 HF hospitalizations [0 %]), surgery in 9 patients (0 deaths, 1 HF hospitalizations [11.1 %]), and medical management in 41 patients (6 deaths [14.6 %], 11 HF hospitalizations [26.8 %]) (p = 0.715 for mortality and p = 0.093 for HF hospitalizations). Residual MR ≥ moderate was 0 %, 50 %, and 100 % for surgery, M-TEER and medical treatment, respectively (p < 0.001). CONCLUSIONS: One third of patients deemed ineligible for TMVR are candidates for high-risk M-TEER or surgery with acceptable morbidity and mortality. Our results have practical implications for patient management.


Assuntos
Cateterismo Cardíaco , Definição da Elegibilidade , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral , Seleção de Pacientes , Humanos , Feminino , Masculino , Idoso , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Idoso de 80 Anos ou mais , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Resultado do Tratamento , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Fatores de Tempo , Medição de Risco , Estudos Prospectivos , Recuperação de Função Fisiológica , Desenho de Prótese , Tomada de Decisão Clínica
6.
JACC Case Rep ; 29(4): 102214, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38379661

RESUMO

Migration or embolization of transcatheter aortic valve replacement (TAVR) prosthesis is an uncommon (usually acute) complication. Associated risk factors include malpositioning, pacing miscapture, undersizing, postdilation, and bicuspid anatomy. Delayed migration is exceedingly rare with little experience reported. The presentation can be catastrophic, requiring emergency surgery. Herein, we present a case of late TAVR migration managed with repeat transfemoral TAVR.

9.
J Am Heart Assoc ; 12(24): e031855, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38063187

RESUMO

Thrombocytopenia is a rare but serious complication of the intravenous glycoprotein IIb/IIIa (GPIIb/IIIa; integrin αIIbß3) receptor inhibitors (GPIs), abciximab, eptifibatide, and tirofiban. The thrombocytopenia ranges from mild (50 000-100 000 platelets/µL), to severe (20 000 to <50 000/µL), to profound (<20 000/µL). Profound thrombocytopenia appears to occur in <1% of patients receiving their first course of therapy. Thrombocytopenia can be either acute (<24 hours) or delayed (up to ~14 days). Both hemorrhagic and thrombotic complications have been reported in association with thrombocytopenia. Diagnosis requires exclusion of pseudothrombocytopenia and heparin-induced thrombocytopenia. Therapy based on the severity of thrombocytopenia and symptoms may include drug withdrawals and treatment with steroids, intravenous IgG, and platelet transfusions. Abciximab-associated thrombocytopenia is most common and due to either preformed antibodies or antibodies induced in response to abciximab (delayed). Readministration of abciximab is associated with increased risk of thrombocytopenia. Evidence also supports an immune basis for thrombocytopenia associated with the 2 small molecule GPIs. The latter bind αIIbß3 like the natural ligands and thus induce the receptor to undergo major conformational changes that potentially create neoepitopes. Thrombocytopenia associated with these drugs is also immune-mediated, with antibodies recognizing the αIIbß3 receptor only in the presence of the drug. It is unclear whether the antibody binding depends on the conformational change and whether the drug contributes directly to the epitope. Zalunfiban, a second-generation subcutaneous small molecule GPI, does not induce the conformational changes; therefore, data from studies of zalunfiban will provide information on the contribution of the conformational changes to the development of GPI-associated thrombocytopenia.


Assuntos
Inibidores da Agregação Plaquetária , Trombocitopenia , Humanos , Abciximab/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Complexo Glicoproteico GPIIb-IIIa de Plaquetas , Anticorpos Monoclonais/uso terapêutico , Fragmentos Fab das Imunoglobulinas/efeitos adversos , Tirosina , Trombocitopenia/induzido quimicamente
10.
Circ Cardiovasc Interv ; 16(10): e012898, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37847770

RESUMO

BACKGROUND: Coronary intravascular lithotripsy (IVL) safely facilitates successful stent implantation in severely calcified lesions. This analysis sought to determine the relative impact of lesion calcium eccentricity on the safety and effectiveness of IVL using high-resolution optical coherence tomography imaging. METHODS: Individual patient-level data (n=262) were pooled from 4 distinct international prospective studies (Disrupt CAD I, II, III, and IV) and analyzed by an independent optical coherence tomography core laboratory. IVL performance in eccentric versus concentric calcification was analyzed by dividing calcified lesions into quartiles (≤180° [most eccentric], 181°-270°, 271°-359°, and 360° [concentric]) by maximum continuous calcium arc. RESULTS: In the 230 patients with clear imaging field on optical coherence tomography, there were no differences in preprocedure minimum lumen area, diameter stenosis, or maximum calcium thickness. The calcium length and volume index increased progressively with increasing mean and maximum continuous calcium arc (ie, concentricity). Conversely, the minimum calcium thickness decreased progressively with increasing concentricity. Post-procedure, the number of calcium fractures, fracture depth, and fracture width increased with increasing concentricity, with a 4-fold increase in the number of fractures in lesions with 360° of calcium arc compared with ≤180°. This increase in IVL-induced calcium fracture with increasing calcium burden and concentricity facilitated stent expansion and luminal gain such that there were no significant differences across quartiles. CONCLUSIONS: IVL induced calcium fractures proportional to the magnitude of coronary artery calcium, including in eccentric calcium, leading to consistent improvements in stent expansion and luminal gain in both eccentric and concentric calcified coronary lesions.


Assuntos
Doença da Artéria Coronariana , Litotripsia , Calcificação Vascular , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Cálcio , Estudos Prospectivos , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Stents , Litotripsia/efeitos adversos
11.
Am J Cardiol ; 207: 370-379, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37778226

RESUMO

The EVOLVE Short DAPT study demonstrated the safety of truncated dual antiplatelet therapy (DAPT) in patients with a high bleeding risk (HBR) treated with SYNERGY stent(s) (Boston Scientific Company, Marlborough, Massachusetts). In this population, bleeding and ischemic risk prediction may further inform DAPT decisions. This post hoc analysis of the EVOLVE Short DAPT study identified predictors of ischemic and bleeding events up to 15 months using Cox proportional hazard models. The predicted probabilities of bleeding were calculated using the Breslow method. Of 2,009 enrolled patients, 96.9% of the patients met at least 1 HBR criteria. At 15 months, the cumulative incidences of bleeding and ischemic events were 6.3% and 6.0%, respectively. The risk of bleeding was increased in patients who received oral anticoagulants (hazard ratio [HR] 2.24, 95% confidence interval [CI] 1.50 to 3.36, p <0.001) or had peripheral vascular disease (HR 1.61, 95% CI 1.01 to 2.56, p = 0.045). The risk of ischemic events was increased in patients with diabetes (HR 1.86, 95% CI 1.24 to 2.78, p <0.01) or congestive heart failure (HR 2.06, 95% CI 1.39 to 3.04, p <0.001). Renal insufficiency/failure was associated with both endpoints. There was a strong positive correlation between the predicted probability of ischemic and bleeding events (R = 0.77, p <0.001). In 617 patients with a predicted bleeding risk <4%, ischemic events predominated, and the ischemic and bleeding rates were higher in patients with a predicted bleeding risk ≥4%. Within an HBR cohort, specific characteristics identify patients at a higher risk for ischemic and separately, bleeding events. Increased bleeding risk is tied to increased ischemic risk. In conclusion, standardized risk models are needed to inform DAPT decisions in patients with a higher risk. Clinical Trial Registration: NCT02605447.


Assuntos
Terapia Antiplaquetária Dupla , Hemorragia , Humanos , Quimioterapia Combinada , Terapia Antiplaquetária Dupla/efeitos adversos , Terapia Antiplaquetária Dupla/métodos , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Incidência , Inibidores da Agregação Plaquetária/uso terapêutico , Stents , Resultado do Tratamento
13.
JACC Cardiovasc Interv ; 16(17): 2137-2138, 2023 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-37704300
15.
JACC Cardiovasc Interv ; 16(16): 1953-1960, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37212431

RESUMO

BACKGROUND: Transcatheter treatment of patients with native aortic valve regurgitation (AR) has been limited by anatomical factors. No transcatheter device has received U.S. regulatory approval for the treatment of patients with AR. OBJECTIVES: The aim of this study was to describe the compassionate-use experience in North America with a dedicated transcatheter device (J-Valve). METHODS: A multicenter, observational registry was assembled of compassionate-use cases of J-Valve implantation for the treatment of patients with severe symptomatic AR and elevated surgical risk in North America. The J-Valve consists of a self-expanding Nitinol frame, bovine pericardial leaflets, and a valve-locating feature. The available size matrix (5 sizes) can treat a wide range of anatomies (minimum and maximum annular perimeters 57-104 mm). RESULTS: A total of 27 patients (median age 81 years [IQR: 72-85 years], 81% at high surgical risk, 96% in NYHA functional class III or IV) with native valve AR were treated with the J-Valve during the study period (2018-2022). Procedural success (J-Valve delivered to the intended location without the need for surgical conversion or a second transcatheter heart valve) was 81% (22 of 27 cases) in the overall experience and 100% in the last 15 cases. Two cases required conversion to surgery in the early experience, leading to changes in valve design. At 30 days, there was 1 death, 1 stroke, and 3 new pacemakers (13%), and 88% of patients were in NYHA functional class I or II. No patient had residual AR of moderate or greater degree at 30 days. CONCLUSIONS: The J-Valve appears to provide a safe and effective alternative to surgery in patients with pure AR and elevated or prohibitive surgical risk.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Animais , Bovinos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Desenho de Prótese , Estenose da Valva Aórtica/cirurgia , Fatores de Risco
16.
J Am Coll Cardiol ; 82(3): 183-195, 2023 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-37207924

RESUMO

BACKGROUND: Bioresorbable vascular scaffolds (BVS) were designed to improve late event-free survival compared with metallic drug-eluting stents. However, initial trials demonstrated worse early outcomes with BVS, in part due to suboptimal technique. In the large-scale, blinded ABSORB IV trial, polymeric everolimus-eluting BVS implanted with improved technique demonstrated noninferior 1-year outcomes compared with cobalt chromium everolimus-eluting stents (CoCr-EES). OBJECTIVES: This study sought to evaluate the long-term outcomes from the ABSORB IV trial. METHODS: We randomized 2,604 patients at 147 sites with stable or acute coronary syndromes to BVS with improved technique vs CoCr-EES. Patients, clinical assessors, and event adjudicators were blinded to randomization. Five-year follow-up was completed. RESULTS: Target lesion failure at 5 years occurred in 216 (17.5%) patients assigned to BVS and 180 (14.5%) patients assigned to CoCr-EES (P = 0.03). Device thrombosis within 5 years occurred in 21 (1.7%) BVS and 13 (1.1%) CoCr-EES patients (P = 0.15). Event rates were slightly greater with BVS than CoCr-EES through 3-year follow-up and were similar between 3 and 5 years. Angina, also centrally adjudicated, recurred within 5 years in 659 patients (cumulative rate 53.0%) assigned to BVS and 674 (53.3%) patients assigned to CoCr-EES (P = 0.63). CONCLUSIONS: In this large-scale, blinded randomized trial, despite the improved implantation technique, the absolute 5-year rate of target lesion failure was 3% greater after BVS compared with CoCr-EES. The risk period for increased events was limited to 3 years, the time point of complete scaffold bioresorption; event rates were similar thereafter. Angina recurrence after intervention was frequent during 5-year follow-up but was comparable with both devices.(Absorb IV Randomized Controlled Trial; NCT02173379).


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Implantes Absorvíveis , Everolimo , Desenho de Prótese , Stents , Alicerces Teciduais , Resultado do Tratamento
17.
JACC Cardiovasc Interv ; 16(10): 1144-1156, 2023 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-37225285

RESUMO

BACKGROUND: Uncertainty exists whether coronary revascularization plus medical therapy (MT) is associated with an increase in noncardiac mortality in chronic coronary syndrome (CCS) when compared with MT alone, particularly following recent data from the ISCHEMIA-EXTEND (International Study of Comparative Health Effectiveness with Medical and Invasive Approaches) trial. OBJECTIVES: This study conducted a large-scale meta-analysis of trials comparing elective coronary revascularization plus MT vs MT alone in patients with CCS to determine whether revascularization has a differential impact on noncardiac mortality at the longest follow-up. METHODS: We searched for randomized trials comparing revascularization plus MT vs MT alone in patients with CCS. Treatment effects were measured by rate ratios (RRs) with 95% CIs, using random-effects models. Noncardiac mortality was the prespecified endpoint. The study is registered with PROSPERO (CRD42022380664). RESULTS: Eighteen trials were included involving 16,908 patients randomized to either revascularization plus MT (n = 8,665) or to MT alone (n = 8,243). No significant differences were detected in noncardiac mortality between the assigned treatment groups (RR: 1.09; 95% CI: 0.94-1.26; P = 0.26), with absent heterogeneity (I2 = 0%). Results were consistent without the ISCHEMIA trial (RR: 1.00; 95% CI: 0.84-1.18; P = 0.97). By meta-regression, follow-up duration did not affect noncardiac death rates with revascularization plus MT vs MT alone (P = 0.52). Trial sequential analysis confirmed the reliability of meta-analysis, with the cumulative Z-curve of trial evidence within the nonsignificance area and reaching futility boundaries. Bayesian meta-analysis findings were consistent with the standard approach (RR: 1.08; 95% credible interval: 0.90-1.31). CONCLUSIONS: In patients with CCS, noncardiac mortality in late follow-up was similar for revascularization plus MT compared with MT alone.


Assuntos
Coração , Humanos , Teorema de Bayes , Reprodutibilidade dos Testes , Resultado do Tratamento , Síndrome , Ensaios Clínicos Controlados Aleatórios como Assunto
20.
J Card Fail ; 29(7): 1046-1055, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36958391

RESUMO

BACKGROUND: Left ventricular (LV) volume reshaping reduces myocardial wall stress and may induce reverse remodeling in patients with heart failure with reduced ejection fraction. The AccuCinch Transcatheter Left Ventricular Restoration system consists of a series of anchors connected by a cable implanted along the LV base that is cinched to the basal free wall radius. We evaluated the echocardiographic and clinical outcomes following transcatheter left ventricular restoration. METHODS AND RESULTS: We analyzed 51 heart failure patients with a left ventricular ejection fraction between 20% and 40%, with no more than 2+ mitral regurgitation treated with optimal medical therapy, who subsequently underwent transcatheter left ventricular restoration. Serial echocardiograms, Kansas City Cardiomyopathy Questionnaire scores, and 6-minute walk test distances were measured at baseline through 12 months. Primary analysis end point was change in end-diastolic volume at 12 months compared with baseline. Patients (n = 51) were predominantly male (86%) with a mean age of 56.3 ± 13.1 years. Fluoroscopy showed LV free wall radius decreased by a median of 9.2 mm amounting to a 29.6% decrease in the free wall arc length. At 12 months, the LV end-diastolic volume decreased by 33.6 ± 34.8 mL (P < .01), with comparable decreases in the LV end-systolic volume. These decreases were associated with significant improvements in the overall Kansas City Cardiomyopathy Questionnaire score (16.4 ± 18.7 points; P < .01) and 6-minute hall walk test distance (45.9 ± 83.9 m; P < .01). There were no periprocedural deaths; through the 1-year follow-up, 1 patient died (day 280) and 1 patient received a left ventricular assist device (day 13). CONCLUSIONS: In patients with heart failure with reduced ejection fraction without significant mitral regurgitation receiving optimal medical therapy, the AccuCinch System resulted in decreases of LV volume, as well as improved quality of life and exercise endurance. A randomized trial is ongoing (NCT04331769).


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA