Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 281
Filtrar
1.
J Dermatol ; 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605448

RESUMO

Drug causality assessment in severe cutaneous adverse reactions (SCARs) remains challenging. We investigated the usefulness of in-vivo drug patch tests (PT), ex-vivo interferon (IFN)-γ enzyme-linked immunospot (ELISpot) assay, and lymphocyte transformation test (LTT) in 30 SCARs patients within the past 36 months. Drug PT yielded a 20% positivity rate (n = 6), while IFN-γ ELISpot and LTT showed positive rates of 56.67% (n = 17) and 41.38% (n = 12), respectively. Combining the three tests resulted in an overall positive rate of 66.67% (n = 20) of cases. IFN-γ ELISpot offered additional positivity, especially with oxypurinol. Employing a combined diagnostic approach may enhance the chances of obtaining a positive result.

2.
Phys Rev E ; 109(2-2): 025203, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38491694

RESUMO

An indirect-drive inertial fusion experiment on the National Ignition Facility was driven using 2.05 MJ of laser light at a wavelength of 351 nm and produced 3.1±0.16 MJ of total fusion yield, producing a target gain G=1.5±0.1 exceeding unity for the first time in a laboratory experiment [Phys. Rev. E 109, 025204 (2024)10.1103/PhysRevE.109.025204]. Herein we describe the experimental evidence for the increased drive on the capsule using additional laser energy and control over known degradation mechanisms, which are critical to achieving high performance. Improved fuel compression relative to previous megajoule-yield experiments is observed. Novel signatures of the ignition and burn propagation to high yield can now be studied in the laboratory for the first time.

3.
Rev Sci Instrum ; 94(6)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37862497

RESUMO

Neutrons generated in Inertial Confinement Fusion (ICF) experiments provide valuable information to interpret the conditions reached in the plasma. The neutron time-of-flight (nToF) technique is well suited for measuring the neutron energy spectrum due to the short time (100 ps) over which neutrons are typically emitted in ICF experiments. By locating detectors 10s of meters from the source, the neutron energy spectrum can be measured to high precision. We present a contextual review of the current state of the art in nToF detectors at ICF facilities in the United States, outlining the physics that can be measured, the detector technologies currently deployed and analysis techniques used.

4.
Phys Rev Lett ; 131(6): 065101, 2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37625041

RESUMO

The change in the power balance, temporal dynamics, emission weighted size, temperature, mass, and areal density of inertially confined fusion plasmas have been quantified for experiments that reach target gains up to 0.72. It is observed that as the target gain rises, increased rates of self-heating initially overcome expansion power losses. This leads to reacting plasmas that reach peak fusion production at later times with increased size, temperature, mass and with lower emission weighted areal densities. Analytic models are consistent with the observations and inferences for how these quantities evolve as the rate of fusion self-heating, fusion yield, and target gain increase. At peak fusion production, it is found that as temperatures and target gains rise, the expansion power loss increases to a near constant ratio of the fusion self-heating power. This is consistent with models that indicate that the expansion losses dominate the dynamics in this regime.

5.
Rev Sci Instrum ; 93(11): 113528, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461449

RESUMO

In the dynamic environment of burning, thermonuclear deuterium-tritium plasmas, diagnosing the time-resolved neutron energy spectrum is of critical importance. Strategies exist for this diagnosis in magnetic confinement fusion plasmas, which presently have a lifetime of ∼1012 longer than inertial confinement fusion (ICF) plasmas. Here, we present a novel concept for a simple, precise, and scale-able diagnostic to measure time-resolved neutron spectra in ICF plasmas. The concept leverages general tomographic reconstruction techniques adapted to time-of-flight parameter space, and then employs an updated Monte Carlo algorithm and National Ignition Facility-relevant constraints to reconstruct the time-evolving neutron energy spectrum. Reconstructed spectra of the primary 14.028 MeV nDT peak are in good agreement with the exact synthetic spectra. The technique is also used to reconstruct the time-evolving downscattered spectrum, although the present implementation shows significantly more error.

6.
Rev Sci Instrum ; 93(11): 113550, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461502

RESUMO

The analysis of the National Ignition Facility (NIF) neutron time-of-flight (nToF) detectors uses a forward-fit routine that depends critically on the instrument response functions (IRFs) of the diagnostics. The details of the IRFs used can have large impacts on measurements such as ion temperature and down-scattered ratio (DSR). Here, we report on the recent steps taken to construct and validate nToF IRFs at the NIF to an increased degree of accuracy, as well as remove the need for fixed DSR baseline offsets. The IRF is treated in two parts: a "core," measured experimentally with an x-ray impulse source, and a "tail" that occurs later in time and has limited experimental data. The tail region is calibrated with the data from indirect drive exploding pusher shots, which have little neutron scattering and are traditionally assumed to have zero DSR. Using analytic modeling estimates, the non-zero DSR for these shots is estimated. The impact of varying IRF tail components on DSR is investigated with a systematic parameter study, and good agreement is found with the non-zero DSR estimates. These approaches will be used to improve the precision and uncertainty of NIF nToF DSR measurements.

7.
Rev Sci Instrum ; 93(11): 113536, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461534

RESUMO

A concept for using an intermediate distance (0.3-3.0 m) neutron time-of-flight (nToF) to provide a constraint on the measurement of the time-dependence of ion temperature in inertial confinement fusion implosions is presented. Simulated nToF signals at different distances are generated and, with a priori knowledge of the burn-averaged quantities and burn history, analyzed to determine requirements for a future detector. Results indicate a signal-to-noise ratio >50 and time resolution <20 ps to constrain the ion temperature gradient to ∼±25% (0.5 keV/100 ps).

8.
Rev Sci Instrum ; 93(10): 103510, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36319336

RESUMO

In support of future radiation-effects testing, a combined environment source has been developed for the National Ignition Facility (NIF), utilizing both NIF's long-pulse beams, and the Advanced Radiographic Capability (ARC) short pulse lasers. First, ARC was used to illuminate a gold foil at high-intensity, generating a significant x-ray signal >1 MeV. This was followed by NIF 10 ns later to implode an exploding pusher target filled with fusionable gas for neutron generation. The neutron and x-ray bursts were incident onto a retrievable, close-standoff diagnostic snout. With separate control over both neutron and x-ray emission, the platform allows for tailored photon and neutron fluences and timing on a recoverable test sample. The platform exceeded its initial fluence goals, demonstrating a neutron fluence of 2.3 ×1013 n/cm2 and an x-ray dose of 7 krad.

9.
Phys Rev E ; 106(2-2): 025202, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36109932

RESUMO

An inertial fusion implosion on the National Ignition Facility, conducted on August 8, 2021 (N210808), recently produced more than a megajoule of fusion yield and passed Lawson's criterion for ignition [Phys. Rev. Lett. 129, 075001 (2022)10.1103/PhysRevLett.129.075001]. We describe the experimental improvements that enabled N210808 and present the first experimental measurements from an igniting plasma in the laboratory. Ignition metrics like the product of hot-spot energy and pressure squared, in the absence of self-heating, increased by ∼35%, leading to record values and an enhancement from previous experiments in the hot-spot energy (∼3×), pressure (∼2×), and mass (∼2×). These results are consistent with self-heating dominating other power balance terms. The burn rate increases by an order of magnitude after peak compression, and the hot-spot conditions show clear evidence for burn propagation into the dense fuel surrounding the hot spot. These novel dynamics and thermodynamic properties have never been observed on prior inertial fusion experiments.

10.
Phys Rev E ; 106(2-2): 025201, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36110025

RESUMO

We present the design of the first igniting fusion plasma in the laboratory by Lawson's criterion that produced 1.37 MJ of fusion energy, Hybrid-E experiment N210808 (August 8, 2021) [Phys. Rev. Lett. 129, 075001 (2022)10.1103/PhysRevLett.129.075001]. This design uses the indirect drive inertial confinement fusion approach to heat and compress a central "hot spot" of deuterium-tritium (DT) fuel using a surrounding dense DT fuel piston. Ignition occurs when the heating from absorption of α particles created in the fusion process overcomes the loss mechanisms in the system for a duration of time. This letter describes key design changes which enabled a ∼3-6× increase in an ignition figure of merit (generalized Lawson criterion) [Phys. Plasmas 28, 022704 (2021)1070-664X10.1063/5.0035583, Phys. Plasmas 25, 122704 (2018)1070-664X10.1063/1.5049595]) and an eightfold increase in fusion energy output compared to predecessor experiments. We present simulations of the hot-spot conditions for experiment N210808 that show fundamentally different behavior compared to predecessor experiments and simulated metrics that are consistent with N210808 reaching for the first time in the laboratory "ignition."

12.
Int J Tuberc Lung Dis ; 25(11): 933-938, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34686236

RESUMO

BACKGROUND: Diagnostic tools to identify incipient or subclinical TB stages will be helpful for preventive intervention. A simple biomarker to predict TB may be the monocytes to lymphocytes ratio (ML ratio) in peripheral blood.METHODS: We assessed the relationship between multiple time-updated ML ratio measurements and incidence of TB in people living with HIV (PLWH) after antiretroviral therapy (ART) was initiated. The ML ratio was updated at least every 6 months. TB incidence with corresponding 95% confidence intervals stratified according to time-updated ML ratio was calculated using ML ratio in quartiles.RESULTS: A total of 1305 PLWH were included in the analyses: 46 had incident TB and 1259 remained TB-free. The TB incidence rate was 10.3 (95% CI 7.1-14.9) cases/1000 patient-years (PYR) among participants with ML ratio ≥0.25 compared with 1.1/1000 PYR (95% CI 0.4-2.9) among those with ML ratio <0.15. At cut-point 0.23, the ML ratio provided a diagnostic area under the receiver operating characteristics curve (AROC) of 0.849 (95% CI 0.784-0.914) and a sensitivity of 85% and specificity of 71%.CONCLUSION: Increased ML ratio was predictive of incident TB among PLWH on or after ART. The ML ratio can be a simple tool to stratify the risk of TB in PLWH.


Assuntos
Infecções por HIV , Tuberculose , Contagem de Linfócito CD4 , Testes Diagnósticos de Rotina , Infecções por HIV/complicações , Infecções por HIV/tratamento farmacológico , Infecções por HIV/epidemiologia , Humanos , Incidência , Linfócitos , Monócitos , Tuberculose/diagnóstico , Tuberculose/epidemiologia
13.
Sci Robot ; 6(57)2021 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-34380755

RESUMO

Fish maintain high swimming efficiencies over a wide range of speeds. A key to this achievement is their flexibility, yet even flexible robotic fish trail real fish in terms of performance. Here, we explore how fish leverage tunable flexibility by using their muscles to modulate the stiffness of their tails to achieve efficient swimming. We derived a model that explains how and why tuning stiffness affects performance. We show that to maximize efficiency, muscle tension should scale with swimming speed squared, offering a simple tuning strategy for fish-like robots. Tuning stiffness can double swimming efficiency at tuna-like frequencies and speeds (0 to 6 hertz; 0 to 2 body lengths per second). Energy savings increase with frequency, suggesting that high-frequency fish-like robots have the most to gain from tuning stiffness.

14.
Rev Sci Instrum ; 92(4): 043512, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243456

RESUMO

Nuclear diagnostics provide measurements of inertial confinement fusion implosions used as metrics of performance for the shot. The interpretation of these measurements for shots with low mode asymmetries requires a way of combining the data to produce a "sky map" where the individual line-of-sight values are used to interpolate to other positions in the sky. These interpolations can provide information regarding the orientation of the low mode asymmetries. We describe the interpolation method, associated uncertainties, and correlations between different metrics, e.g., Tion, down scatter ratio, and hot-spot velocity direction. This work is also related to recently reported studies [H. G. Rinderknecht et al., Phys. Rev. Lett. 124, 145002 (2020) and K. M. Woo et al., Phys. Plasmas 27, 062702 (2020)] of low mode asymmetries. We report an analysis that makes use of a newly commissioned line of sight, a scheme for incorporating multiple neutron spectrum measurement types, and recent work on the sources of implosion asymmetry to provide a more complete picture of implosion performance.

15.
Rev Sci Instrum ; 92(5): 053543, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243308

RESUMO

Neutron-yield diagnostics at the NIF have been upgraded to include 48 detectors placed around the NIF target chamber to assess the DT-neutron-yield isotropy for inertial confinement fusion experiments. Real-time neutron-activation detectors are used to understand yield asymmetries due to Doppler shifts in the neutron energy attributed to hotspot motion, variations in the fuel and ablator areal densities, and other physics effects. In order to isolate target physics effects, we must understand the contribution due to neutron scattering associated with the different hardware configurations used for each experiment. We present results from several calibration experiments that demonstrate the ability to achieve our goal of 1% or better precision in determining the yield isotropy.

16.
Rev Sci Instrum ; 92(5): 053526, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243327

RESUMO

Recent inertial confinement fusion measurements have highlighted the importance of 3D asymmetry effects on implosion performance. One prominent example is the bulk drift velocity of the deuterium-tritium plasma undergoing fusion ("hotspot"), vHS. Upgrades to the National Ignition Facility neutron time-of-flight diagnostics now provide vHS to better than 1 part in 104 and enable cross correlations with other measurements. This work presents the impact of vHS on the neutron yield, downscatter ratio, apparent ion temperature, electron temperature, and 2D x-ray emission. The necessary improvements to diagnostic suites to take these measurements are also detailed. The benefits of using cross-diagnostic analysis to test hotspot models and theory are discussed, and cross-shot trends are shown.

17.
Rev Sci Instrum ; 92(4): 043555, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243390

RESUMO

The time-resolved measurement of neutrons emitted from nuclear implosions at inertial confinement fusion facilities is used to characterize the fusing plasma. Several significant quantities are routinely measured by neutron time-of-flight (nToF) detectors in these experiments. Current nToF detectors use scintillators as well as solid-state Cherenkov radiators. The latter has an inherently faster time response and can provide a co-registered γ-ray measurement as well as improved precision in the bulk hot-spot velocity. This work discusses a nToF ellipsoidal detector that also utilizes a solid-state Cherenkov radiator. The detector has the potential to achieve a fast instrument response function allowing for characterization of the γ-ray burn history as well as the ability to field the detector closer to the fusion source. Proof-of-concept testing of the nToF ellipsoidal detector has been conducted at the National Ignition Facility using commercial optics. A time-resolved neutron signal has been measured from the diagnostic. Preliminary simulations corroborate the results.

18.
Phys Rev E ; 103(5-1): 053207, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34134339

RESUMO

We report on the increase in the accelerated electron number and energy using compound parabolic concentrator (CPC) targets from a short-pulse (∼150 fs), high-intensity (>10^{18} W/cm^{2}), and high-contrast (∼10^{8}) laser-solid interaction. We report on experimental measurements using CPC targets where the hot-electron temperature is enhanced up to ∼9 times when compared to planar targets. The temperature measured from the CPC target is 〈T_{e}〉=4.4±1.3 MeV. Using hydrodynamic and particle in cell simulations, we identify the primary source of this temperature enhancement is the intensity increase caused by the CPC geometry that focuses the laser, reducing the focal spot and therefore increasing the intensity of the laser-solid interaction, which is also consistent with analytic expectations for the geometrical focusing.

19.
Nat Med ; 27(7): 1290-1297, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34108714

RESUMO

Reports of ChAdOx1 vaccine-associated thrombocytopenia and vascular adverse events have led to some countries restricting its use. Using a national prospective cohort, we estimated associations between exposure to first-dose ChAdOx1 or BNT162b2 vaccination and hematological and vascular adverse events using a nested incident-matched case-control study and a confirmatory self-controlled case series (SCCS) analysis. An association was found between ChAdOx1 vaccination and idiopathic thrombocytopenic purpura (ITP) (0-27 d after vaccination; adjusted rate ratio (aRR) = 5.77, 95% confidence interval (CI), 2.41-13.83), with an estimated incidence of 1.13 (0.62-1.63) cases per 100,000 doses. An SCCS analysis confirmed that this was unlikely due to bias (RR = 1.98 (1.29-3.02)). There was also an increased risk for arterial thromboembolic events (aRR = 1.22, 1.12-1.34) 0-27 d after vaccination, with an SCCS RR of 0.97 (0.93-1.02). For hemorrhagic events 0-27 d after vaccination, the aRR was 1.48 (1.12-1.96), with an SCCS RR of 0.95 (0.82-1.11). A first dose of ChAdOx1 was found to be associated with small increased risks of ITP, with suggestive evidence of an increased risk of arterial thromboembolic and hemorrhagic events. The attenuation of effect found in the SCCS analysis means that there is the potential for overestimation of the reported results, which might indicate the presence of some residual confounding or confounding by indication. Public health authorities should inform their jurisdictions of these relatively small increased risks associated with ChAdOx1. No positive associations were seen between BNT162b2 and thrombocytopenic, thromboembolic and hemorrhagic events.


Assuntos
Vacinas contra COVID-19/uso terapêutico , COVID-19/prevenção & controle , Hemorragia/epidemiologia , Púrpura Trombocitopênica Idiopática/epidemiologia , Trombocitopenia/epidemiologia , Tromboembolia/epidemiologia , Tromboembolia Venosa/epidemiologia , Adolescente , Adulto , Idoso , Vacina BNT162 , Estudos de Casos e Controles , ChAdOx1 nCoV-19 , Estudos de Coortes , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , SARS-CoV-2 , Escócia/epidemiologia , Trombose dos Seios Intracranianos/epidemiologia , Adulto Jovem
20.
Rhinology ; 59(3): 284-291, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33821291

RESUMO

BACKGROUND: Low-dose macrolides (LDM) are anti-inflammatory agents with antineutrophilic activity, but patient selection for LDM therapy in treating chronic rhinosinusitis (CRS) is controversial. This study aimed to assess factors which predict LDM responders. METHODOLOGY: A prospective cohort study was performed. Patients with CRS received roxithromycin (150 mg) once daily for 12 weeks. Nasal secretions and serology were collected. Nine predictors for LDM response were assessed: nasal secretion IgE, nasal secretion IL-5, serum IgE, serum eosinophils, serum neutrophils, nasal polyps, asthma, allergy, and aspirin hypersensitivity, using receiver-operating curve analysis and multivariable logistic regression. Macrolide responders were those with sino-nasal outcome test-22 improvement, symptoms visual analogue scale decreased to ≤ ≤ ≤5, and no rescue medication. RESULTS: One hundred CRS patients (mean age 47.4 +- 14.1 years, 45% male) were enrolled. Univariable logistic regression showed local total IgE less than 5.21; and serum eosinophils less than 2.2% associated with macrolide response. Multivariate models showed local total IgE maintained an independent association with macrolide response, with an ability to discriminate between responders and non-responders of 63%. Serum total IgE, nasal secretion IL-5, serum neutrophil, nasal polyp, asthma, allergy, and aspirin hypersensitivity showed no association with LDM response. CONCLUSIONS: Low total IgE level in the nasal secretion but not in the serum, predict LDM response.


Assuntos
Pólipos Nasais , Rinite , Sinusite , Adulto , Doença Crônica , Feminino , Humanos , Macrolídeos , Masculino , Pessoa de Meia-Idade , Pólipos Nasais/tratamento farmacológico , Estudos Prospectivos , Rinite/tratamento farmacológico , Sinusite/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...