Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Med Phys ; 47(1): 73-78, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35548029

RESUMO

Purpose: To evaluate the image quality of semi-anatomical chest radiographs acquired using low radiation doses from seven different flat-panel detector (FPD) systems. Materials and Methods: Radiographs of a semi-anatomical chest phantom were acquired at 70 and 110 kVp using 7 different FPDs from 5 vendors. Radiation doses were measured using a dose-area-product (DAP) meter. To standardize measurements across all FPDs, DAP value of 51.05 µGym2 obtained at 70 kVp and 9.43 µGym2 at 110 kVp was used as reference in this study. Radiation doses were reduced by manually adjusting mAs for both tube potentials in all FPD systems to achieve acceptable image quality. Contrast-to-noise ratio, signal-to-noise ratio and figure of merit (FOM) in lung, heart, and diaphragm for all images were analyzed. Results: In comparison with set standard protocol, radiation dose reduction of 20%, 21%, 21.6%, 59.5%, 60.7%, 62.2%, and 67.6% with optimal image quality was observed in Prognosys Prorad, GE Definium 8000, Siemens Fusion, Fujifilm FGX, Fujifilm FGXR, Philips Digital Diagnost and Siemens Aristos at 70 kVp. At 110 kVp, dose reduction of 15.7% and 34.8% was possible only for Philips Digital Diagnost and Siemens Aristos. FOM was high at 110 kVp even when radiation doses were reduced by a factor 2 when compared to 70 kVp in all digital radiography systems. Conclusion: This study demonstrates the feasibility of using a semi-anatomical chest phantom in the optimization of radiation dose and image quality. The FOM was a good indicator in assessing image quality between different detectors.

2.
J Indian Assoc Pediatr Surg ; 27(1): 60-64, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35261515

RESUMO

Introduction: Core needle biopsies of solid masses in children are a minimally invasive technique. It guides to a definitive diagnosis and facilitates management. Aims and Objectives: To determine the accuracy, sensitivity, and specificity of core needle biopsies in diagnosing pediatric solid masses. Materials and Methods: A retrospective analysis of 430 children, who underwent core needle biopsy for solid masses between January 2007 and December 2016 at CMC Vellore, was done. Results: Retroperitoneal and intra-abdominal masses constituted 66% of cases. Real-time image guidance was used in 44% of cases. An accurate diagnosis was obtained in 93.6% of cases, while results did not correlate with the final diagnosis in 3.4%. Three percent had inadequate or necrotic tissue. None of the children had postprocedure complications. Conclusion: Core needle biopsies serve as good diagnostic modality, with minimal risks, in making a conclusive diagnosis and deciding on the line of management.

3.
Ann Indian Acad Neurol ; 23(4): 522-527, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33223671

RESUMO

BACKGROUND AND PURPOSE: Studies looking at seasonal variation on cerebral venous thrombosis (CVT) are few with conflicting conclusions. In this region-specific study, we looked for climatic influence and seasonal trends on the incidence of CVT. METHODS: Imaging proven adult CVT cases treated over a period of 18 years from a specific geographical location with similar seasons and climatic conditions were studied. Metrological parameters prepared using 30 years of data was used. Quantum geographical information system (QGIS software) and SPSS v 22 were used for patient plotting and analysis. RESULTS: Total of 970 cases were studied. The incidence was significantly higher in summer 411 (42.3%) compared with autumn 317 (32.7%) and winter 242 (25.05); P = 0.038. This trend was consistent across all the 18 years in time series analysis. Mean age was 33.5 years (range 18-88 years). A significant majority 673 (69.4%) were below 40 years of age; P = 0.012. Females constituted 394 (40.6%) of cases. Postpartum CVT cases constituted 237 (30%). Interaction analysis showed younger age (<40 years) were more vulnerable for CVT in summer; P = 0.009. There was no seasonal influence on postpartum CVT. Apart for a weak positive correlation between rain fall (r = 0.18, P < 0.01); humidity and cloud cover was not influencing the incidence. CONCLUSIONS: Higher ambient temperatures were consistently associated with higher incidence of CVT. This is the largest region-specific study on CVT in the world. These results may be applicable to other regions with similar climatic conditions.

5.
J Clin Exp Hepatol ; 9(5): 625-651, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31695253

RESUMO

Hepatocellular carcinoma (HCC) is the 6th most common cancer and the second most common cause of cancer-related mortality worldwide. There are currently no universally accepted practice guidelines for the diagnosis of HCC on imaging owing to the regional differences in epidemiology, target population, diagnostic imaging modalities, and staging and transplant eligibility. Currently available regional and national guidelines include those from the American Association for the Study of Liver Disease (AASLD), the European Association for the Study of the Liver (EASL), the Asian Pacific Association for the Study of the Liver, the Japan Society of Hepatology, the Korean Liver Cancer Study Group, Hong Kong, and the National Comprehensive Cancer Network in the United States. India with its large population and a diverse health infrastructure faces challenges unique to its population in diagnosing HCC. Recently, American Association have introduced a Liver Imaging Reporting and Data System (LIRADS, version 2017, 2018) as an attempt to standardize the acquisition, interpretation, and reporting of liver lesions on imaging and hence improve the coherence between radiologists and clinicians and provide guidance for the management of HCC. The aim of the present consensus was to find a common ground in reporting and interpreting liver lesions pertaining to HCC on imaging keeping LIRADSv2018 in mind.

7.
J Med Case Rep ; 5: 115, 2011 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-21435206

RESUMO

INTRODUCTION: We present a case report highlighting the unusual location and atypical imaging characteristics of an osteoid osteoma in the juxta-articular region of the femoral head, and treatment of the condition with radiofrequency ablation. This treatment option is low in both risk and morbidity and is therefore the best option in lesions that are difficult to access surgically because of the risks involved. CASE PRESENTATION: A 40-year-old Indian man from West Bengal presented to our facility with a history of progressively severe left hip pain of insidious onset, requiring analgesics. Imaging with plain radiographs, computed tomography and magnetic resonance imaging confirmed findings of osteoid osteoma in a subarticular location in the femoral head, although imaging features were atypical due to the intra-articular subchondral location. CONCLUSION: Radiofrequency ablation is a newer treatment modality for osteoid osteoma that, being minimally invasive, offers comparable results to surgery with a significantly lower morbidity. To the best of our knowledge, treatment of osteoid osteoma in the foveal region of the femoral head with radiofrequency ablation has not been reported to date. We wish to highlight the successful outcome in our index case using this technique.

8.
Indian J Urol ; 25(1): 56-61, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19468430

RESUMO

PURPOSE: To assess the effects of transplant renal artery stenosis (TRAS) on blood pressure, renal function, and graft survival. To assess the usefulness of Doppler in predicting the clinical significance of TRAS and also to identify the predictive factors in Doppler that correlated with clinical features of TRAS. MATERIALS AND METHODS: A prospective study was done on consecutive renal allograft recipients at Christian Medical College, over a period of 66 months from January 2002. All recipients underwent Doppler ultrasound (DUS) evaluation on the fifth post-operative day. Subsequent evaluation was done if the patients had any clinical or biochemical suspicion of TRAS. Angiogram was done in case of a high index of suspicion of significant stenosis or before angioplasty and stenting. The clinical and radiological outcomes of the patients with symptomatic or asymptomatic TRAS were analyzed. RESULTS: Five hundred and forty three consecutive renal allograft recipients were analyzed, of whom, 43 were found to have TRAS. Nine recipients (21%) were detected to have TRAS on first evaluation. All had a high peak systolic velocities (PSV) recorded while 25 of them had other associated features. Patients with only high PSV required no further intervention and were followed up. They had a pretransplant mean arterial pressure (MAP) of 107.83 mmHg (SD = 13.32), ranging from 90 to 133 mm Hg and a posttransplant MAP of 106.56 mmHg (SD =16.51), ranging from 83 to 150 mm Hg. Their mean nadir serum creatinine was 1.16 mg% (SD = 0.24), at detection was 1.6 mg% (SD = 1.84) and at 6 months follow-up was 1.26 mg% (SD=0.52). Of the remaining 25 patients with other associated Doppler abnormalities, 11 required further intervention in the form of re-exploration in 2, angioplasty in 3 and stenting in 6 patients. One patient in the group of patients intervened, expired in the immediate post-operative period due to overwhelming urosepsis and consumption coagulopathy. The mean creatinine clearance (Cockroft-Gault method) in this group of remaining 10 patients, before and after intervention was 44.75 ml/min (SD=17.85) and 68.96 ml/min (SD = 10.56), respectively, with a mean increase by 24.21 ml/min (P=0.000). The mean arterial pressure before and after intervention in this group were 132.80 mm Hg (SD = 13.22) and 102 mm Hg (SD = 10.55), with a decline in the MAP by 30.80 mmHg (P=0.017). The haemoglobin levels also increased from 11.72 (SD=2.13) to 12.48 gm% (SD = 1.75), with a mean increase by 0.76 gm% (P=0.05). CONCLUSIONS: Patients with isolated high PSV do not have a significant alteration of blood pressure or allograft function and required no intervention. Although high PSV with associated Doppler anomalies are more suggestive of significant TRAS, the decision regarding surgical intervention is largely based on clinical assessment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...