Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Public Health ; 11: 1073612, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36860397

RESUMO

Introduction: Domestic violence against a woman, inflicted by her husband/partner, disrupts the socially recognized model of partnership and family life and endangers the health and life of the victim. The aim of the study was to assess the level of satisfaction with the life of Polish women experiencing domestic violence and compare it to results of women not experiencing domestic violence. Methods: A cross-sectional study was conducted on a convenience sample of 610 Polish women divided in two groups: victims of domestic violence (Group 1, n = 305) and women not experiencing domestic violence (Group 2, n = 305). Results and Conclusions: Most Polish women experiencing domestic violence are characterized by low life satisfaction. The mean value of life satisfaction in Group 1 was 13.78, SD = 4.88, significantly lower when compared to Group 2 (M = 21.04, SD = 5.61). Their satisfaction with life is related, among other things, to the form of violence inflicted upon them by their husband/partner. Abused women with low life satisfaction are most often victims of psychological violence. The most common cause is the perpetrator's addiction to alcohol and/or drugs. Assessment of their life satisfaction is unrelated to help-seeking and to the occurrence of violence in their family home in the past.


Assuntos
Comportamento Aditivo , Violência Doméstica , Humanos , Feminino , Estudos Transversais , Polônia , Satisfação Pessoal
2.
Xenotransplantation ; 26(3): e12496, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30767329

RESUMO

The infection of a vascular prosthesis is potentially fatal, and its effective treatment still remains the greatest challenge for vascular surgeons. We present our initial experience using bovine pericardial vascular prostheses to replace infected aortoiliac vascular grafts. Six consecutive patients with infection of the graft were prospectively included in this study. Infection of the vascular graft was confirmed by clinical symptoms, laboratory tests and the results of computed tomography and positron emission tomography/computed tomography. In all cases, the infected aortoiliac graft was surgically removed and replaced by the bovine-pericardial BioIntegral aortic-bifemoral prosthesis. Technical success was achieved in every case with no in-hospital or 30 days mortality. One patient required revision of distal anastomosis due to recurrent bleeding at day four after surgery. One patient presented with upper gastrointestinal tract bleeding during the postoperative period, which was managed endoscopically. The mean hospital stay was 14 days (range 9-19). The control CT scan performed 2 months after surgery showed significant regression of abscesses and periprosthetic inflammation. Two patients died within 32 months of follow-up: one due to heart attack, the other due to generalized sepsis, which was correlated with the previous infection. Four patients are still in follow-up. The BioIntegral prosthesis is patent in all four cases, with no clinical or ultrasonographic signs of infection. Our brief investigation shows that a bovine pericardial prosthesis may be a valuable option in the treatment of vascular grafts infections.


Assuntos
Aorta/cirurgia , Prótese Vascular , Xenoenxertos/cirurgia , Idoso , Animais , Bovinos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transplante Heterólogo/métodos , Resultado do Tratamento
3.
Pol Przegl Chir ; 86(8): 359-63, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25294704

RESUMO

UNLABELLED: Common use of venipuncture on upper and lower limbs for diagnostic purposes (such as coronarography or arteriography), and also during the course of treatment (angioplasty), very often bares a complication in the form of pseudoaneurysms. According to various reports, the incidence of pseudoaneurysms ranges from 0.005% to 0.5% of all vascular procedures requiring arterial cannulation (Common Femoral Artery, Brachial Artery, Radial Artery). The use of Bio Trombina® 400 in the embolization of pseudoaneurysms allows minimally invasive and effective treatment. The aim of the study was to evaluate the efficacy of pseudoaneurysm embolization with the use of Trombina 400, authors' own experience. MATERIAL AND METHODS: In the years 2011 - 2013, the authors of this study performed 38 vascular interventional procedures involving pseudoaneurysms as complications of venipuncture in upper and lower limbs for diagnostic and treatment purposes. All procedures involved the direct injection of thrombin into the chamber of the pseudoaneurysm under the guidance of USG Doppler (6.2 MHz linear head). 34 cases presented single chamber pseudoaneurysms while 4 cases involved multi- chamber pseudoaneurysms, which required several thrombin reinjections (Bio Trombina® 400) into each of the chambers. Pseudoaneurysm maximum size of 4 cm was set as an inclusion criterion for the embolization procedure. Furthermore, all pseudoaneurysms with a significantly wide tract in transverse dimensions were treated as an exclusion criterion because of high risk of the peripheral arteries embolization. RESULTS: Initial success was observed in 36 patients (94.73%) in the first day after the procedure, 1 patient (2.63%) underwent thrombin reinjection procedure in the second day after the first embolization. Another patient (2.63%) underwent an open procedure in which the Common Femoral Artery was accessed, the clot evacuated, and CFA was sutured with continuous suture Prolene 6-0. CONCLUSIONS: 1. Embolization of pseudoaneurysms with USG Doppler-guided thrombin injection is an effective course of treatment for complications of cannulation. 2. The safety of pseudoaneurysm embolization depends on a surgeon's experience. It is also crucial to keep in mind the inclusion and exclusion criteria for this type of procedure (the size of a pseudoaneurysm, the width of its base). 3. Furthermore, its cost effectiveness and short hospitalization period make pseudoaneurysm embolization an effective and valuable alternative to the classic approach.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/tratamento farmacológico , Cateterismo Periférico/efeitos adversos , Hemostáticos/administração & dosagem , Trombina/administração & dosagem , Falso Aneurisma/etiologia , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/efeitos dos fármacos , Humanos , Masculino , Ultrassonografia Doppler Dupla , Ultrassonografia de Intervenção
4.
Pol Przegl Chir ; 85(11): 638-43, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24413202

RESUMO

UNLABELLED: In patients with severe lower limb ischemia the coagulation and fibrinolytic systems have been found to be activated preoperatively. The aim of the study was to evaluate the changes of TAT level as a selected coagulation factor, before, during and after surgical revascularization and the analysis of the impact of coexisting diseases on the coagulation during the procedure. MATERIAL AND METHODS: 50 patients with PAOD, in Fontaine stages IIb to IV (29 men and 21 women; median age 65.8 years, ASA II/III) undergoing elective surgical revascularization were studied. Two groups of patients were compared: 20 undergoing reconstruction on aorto-femoral and 30 on femoropopliteal level. Blood samples were collected 5 times: 24 hours before the operation; intraoperatively after artery exposure; after heparin administration and clamping; after reperfusion and -24 hours postoperatively. RESULTS: Elevated values of TAT (10.5 g/l ±7.1) were found before the operation. The elevated value of TAT increased intraoperatively (25.1 g/l ±44.58; p<0.001) (norm 1-4.1 g/l) and maintaining higher levels after the surgery. The significant correlations between plasma level of TAT and ischemia degree were found. Also the correlation between intraoperative increase of TAT and the duration of surgery was noticed. No significant differences between two analysed groups were observed. CONCLUSIONS: The results indicate the activation of coagulation and prothrombotic state in the patients with advanced arteriosclerosis. During the surgical revascularisation permanent increase of activation of blood coagulation was observed. This activation depends on duration of the procedure and maintains increased one-day after the operation. Our findings may explain the unexpected occurrence of early thrombotic complications after technically successful vascular reconstructions.


Assuntos
Fatores de Coagulação Sanguínea/metabolismo , Artéria Femoral/cirurgia , Peptídeo Hidrolases/sangue , Doença Arterial Periférica/enzimologia , Doença Arterial Periférica/cirurgia , Idoso , Antitrombina III , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA