1.
Neth Heart J ; 25(2): 106-115, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27921241

RESUMO

OBJECTIVES: We present our single-centre experience with the direct flow medical (DFM) trans-catheter aortic valve implantation (TAVI) prosthesis addressing the impact of learning curve upon outcomes. BACKGROUND: The DFM has been recently introduced for TAVI. The prosthesis presents original design and implantation features. METHODS: Patients were divided into three groups according to the chronological implantation sequence that reflected technical skills acquisition of the entire team. RESULTS: Group I included the first 20 patients (early learning phase), group II the second 20 patients (proctoring to other members of the team), and group III the following 93 patients (technique consolidation). Differences in baseline and procedural variables were analysed. Nonparametric correlation and linear regression were used to identify changes according to institutional cumulative experience. There was a significant correlation between catheterisation time and institutional experience (rho = -0.4; p < 0.0001) confirmed at linear regression (beta = -0.2; p = 0.001; CI: -0.3 - -0.08). Moreover, there was lower rate of valve retrieval in group III (15% vs. 20% vs. 10%; p = 0.5). No intra-procedural mortality was reported and improved early safety (at 30 days) was observed (80% vs. 85% vs. 87.1; p = 0.7). At hospital discharge, valve haemodynamic performance was satisfactory with only mild regurgitation in 10% (I), 20% (II), and 9.7% (III) (p = 0.8). CONCLUSIONS: DFM adequate sizing and implantation can be achieved after the early learning phases. A significant reduction in catheterisation time is reported after the first 20 patients. Results remain satisfactory during the proctoring and technical consolidation phase.

2.
Case Rep Crit Care ; 2016: 4893496, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27867668

RESUMO

Purpose. Pulmonary-renal syndrome (PRS) is characterized by diffuse alveolar hemorrhage and rapidly progressive glomerulonephritis mainly due to autoimmune etiologies. Seronegative PRS is a challenging entity to the clinician, since early diagnosis may be missed leading to delayed appropriate treatment. Materials and Methods. We present the clinical course of a 77-year-old patient who was admitted under the suspected diagnosis of pneumogenic sepsis and septic renal failure with fever, dyspnea, and elevated CRP levels. The diagnosis of pulmonary-renal syndrome was initially missed because of the absence of autoantibodies in all serological findings. Results. Despite delayed initiation of immunosuppressive therapy and a prolonged period of dialysis and extracorporeal membrane oxygenation the patient recovered well and was released to a rehabilitation center with nearly normalized creatinine levels. The diagnosis of PRS was established by renal biopsy. Conclusion. This case illustrates the important differential diagnosis of seronegative pulmonary-renal syndrome in patients with pulmonary and renal impairment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA