Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
1.
JCO Oncol Pract ; : OP2300816, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662969

RESUMO

This review critically analyzes the incidence of trastuzumab-induced left ventricular systolic dysfunction and congestive heart failure (CHF), distinguishing between cases with and without prior anthracycline exposure. It highlights the fact that the elevated risk of trastuzumab-induced cardiotoxicity is closely associated with prior anthracycline exposure. In the absence of prior anthracycline exposure, the incidence rates of trastuzumab-induced cardiotoxicity, particularly CHF (ranging from 0% to 0.5%), are largely comparable with those reported in the general population, especially when reversibility is taken into account. Current cardiac surveillance recommendations during trastuzumab treatment have not yet adapted to the increasing adoption of nonanthracycline treatment strategies and the associated low risk of cardiotoxicity. We propose a refined monitoring protocol to reduce the frequency of cardiac evaluations for low-risk to moderate-risk patients, especially those receiving nonanthracycline treatments. By focusing on patients at high risk or those with prior anthracycline exposure, this strategy seeks to optimize the cost-effectiveness of cardiac care in oncology.

2.
Catheter Cardiovasc Interv ; 103(6): 833-842, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38639137

RESUMO

BACKGROUND: Stent underexpansion, typically related to lesion calcification, is the strongest predictor of adverse events after percutaneous coronary intervention (PCI). Although uncommon, underexpansion may also occur in non-severely calcified lesions. AIM: We sought to identify the prevalence and anatomical characteristics of underexpansion in non-severely calcified lesions. METHODS: We included 993 patients who underwent optical coherence tomography-guided PCI of 1051 de novo lesions with maximum calcium arc <180°. Negative remodeling (NR) was the smallest lesion site external elastic lamina diameter that was also smaller than the distal reference. Stent expansion was evaluated using a linear regression model accounting for vessel tapering; underexpansion required both stent expansion <70% and stent area <4.5mm2. RESULTS: Underexpansion was observed in 3.6% of non-heavily calcified lesions (38/1051). Pre-stent maximum calcium arc and thickness were greater in lesions with versus without underexpansion (median 119° vs. 85°, p = 0.002; median 0.95 mm vs. 0.78 mm, p = 0.008). NR was also more common in lesions with underexpansion (44.7% vs. 24.5%, p = 0.007). In the multivariable logistic regression model, larger and thicker eccentric calcium, mid left anterior descending artery (LAD) location, and NR were associated with underexpansion in non-severely calcified lesions. The rate of underexpansion was especially high (30.7%) in lesions exhibiting all three morphologies. Two-year TLF tended to be higher in underexpanded versus non-underexpanded stents (9.7% vs. 3.7%, unadjusted hazard ratio [95% confidence interval] = 3.02 [0.92, 9.58], p = 0.06). CONCLUSION: Although underexpansion in the absence of severe calcium (<180°) is uncommon, mid-LAD lesions with NR and large and thick eccentric calcium were associated with underexpansion.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Intervenção Coronária Percutânea , Stents , Tomografia de Coerência Óptica , Calcificação Vascular , Humanos , Masculino , Feminino , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Prevalência , Fatores de Risco , Vasos Coronários/diagnóstico por imagem , Resultado do Tratamento , Estudos Retrospectivos , Índice de Gravidade de Doença , Desenho de Prótese , Valor Preditivo dos Testes , Fatores de Tempo , Angiografia Coronária , Remodelação Vascular
3.
Artigo em Inglês | MEDLINE | ID: mdl-38676848

RESUMO

Contrast enhanced pulmonary vein magnetic resonance angiography (PV CE-MRA) has value in atrial ablation pre-procedural planning. We aimed to provide high fidelity, ECG gated PV CE-MRA accelerated by variable density Cartesian sampling (VD-CASPR) with image navigator (iNAV) respiratory motion correction acquired in under 4 min. We describe its use in part during the global iodinated contrast shortage. VD-CASPR/iNAV framework was applied to ECG-gated inversion and saturation recovery gradient recalled echo PV CE-MRA in 65 patients (66 exams) using .15 mmol/kg Gadobutrol. Image quality was assessed by three physicians, and anatomical segmentation quality by two technologists. Left atrial SNR and left atrial/myocardial CNR were measured. 12 patients had CTA within 6 months of MRA. Two readers assessed PV ostial measurements versus CTA for intermodality/interobserver agreement. Inter-rater/intermodality reliability, reproducibility of ostial measurements, SNR/CNR, image, and anatomical segmentation quality was compared. The mean acquisition time was 3.58 ± 0.60 min. Of 35 PV pre-ablation datasets (34 patients), mean anatomical segmentation quality score was 3.66 ± 0.54 and 3.63 ± 0.55 as rated by technologists 1 and 2, respectively (p = 0.7113). Good/excellent anatomical segmentation quality (grade 3/4) was seen in 97% of exams. Each rated one exam as moderate quality (grade 2). 95% received a majority image quality score of good/excellent by three physicians. Ostial PV measurements correlated moderate to excellently with CTA (ICCs range 0.52-0.86). No difference in SNR was observed between IR and SR. High quality PV CE-MRA is possible in under 4 min using iNAV bolus timing/motion correction and VD-CASPR.

4.
Am J Cardiol ; 218: 102-112, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432332

RESUMO

There are various devices under clinical investigation for transcatheter mitral valve intervention and transcatheter tricuspid valve intervention (TTVI); however, the exclusion rates remain high. We aimed to investigate the exclusion rates for transcatheter mitral valve repair (TMVr), transcatheter mitral valve replacement (TMVR), transcatheter tricuspid valve repair (TTVr), and transcatheter tricuspid valve replacement (TTVR). There were 129 patients who were referred to St. Francis Hospital & Heart Center valve clinic and completed screening between January 2021 and July 2022. The causes for exclusion were classified into 4 categories: patient withdrawal, anatomic unsuitability, clinical criteria, and medical futility. In 129 patients, the exclusion rates for TMVr, TMVR, TTVr, and TTVR were 81%, 85%, 91%, and 87%, respectively. Patient withdrawal and medical futility were leading etiologies for exclusion, followed by anatomic unsuitability. TMVr had the highest rate of patient withdrawal (64%) and the lowest anatomic unsuitability (5%) because of short posterior leaflet length. Replacement interventions have a higher anatomic unsuitability (33%) than repair interventions (17%) (p = 0.04). Most exclusions of anatomic unsuitability were because of mitral stenosis or small annulus size for TMVR and large annulus size for TTVR. A total of 50% of exclusions from TTVr were because of the presence of pacemaker/defibrillator leads. In patients excluded from their respective trials, patients being referred for TMVr had the highest recurrent hospitalization and repair group had a higher mortality (p <0.01 and p = 0.01, respectively). In conclusion, the exclusion rates for transcatheter mitral valve intervention and TTVI trials remain high because of various reasons, limiting patient enrollment and treatment. This supports the need for further device improvement or exploring alternative means of therapy.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Tricúspide/cirurgia , Cateterismo Cardíaco , Resultado do Tratamento , Insuficiência da Valva Mitral/cirurgia , Hospitais
5.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38552656

RESUMO

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Ann Thorac Surg ; 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38316377

RESUMO

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.

9.
J Cardiovasc Comput Tomogr ; 18(1): 11-17, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37951725

RESUMO

BACKGROUND: In the last 15 years, large registries and several randomized clinical trials have demonstrated the diagnostic and prognostic value of coronary computed tomography angiography (CCTA). Advances in CT scanner technology and developments of analytic tools now enable accurate quantification of coronary artery disease (CAD), including total coronary plaque volume and low attenuation plaque volume. The primary aim of CONFIRM2, (Quantitative COroNary CT Angiography Evaluation For Evaluation of Clinical Outcomes: An InteRnational, Multicenter Registry) is to perform comprehensive quantification of CCTA findings, including coronary, non-coronary cardiac, non-cardiac vascular, non-cardiac findings, and relate them to clinical variables and cardiovascular clinical outcomes. DESIGN: CONFIRM2 is a multicenter, international observational cohort study designed to evaluate multidimensional associations between quantitative phenotype of cardiovascular disease and future adverse clinical outcomes in subjects undergoing clinically indicated CCTA. The targeted population is heterogenous and includes patients undergoing CCTA for atherosclerotic evaluation, valvular heart disease, congenital heart disease or pre-procedural evaluation. Automated software will be utilized for quantification of coronary plaque, stenosis, vascular morphology and cardiac structures for rapid and reproducible tissue characterization. Up to 30,000 patients will be included from up to 50 international multi-continental clinical CCTA sites and followed for 3-4 years. SUMMARY: CONFIRM2 is one of the largest CCTA studies to establish the clinical value of a multiparametric approach to quantify the phenotype of cardiovascular disease by CCTA using automated imaging solutions.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Placa Aterosclerótica , Humanos , Angiografia por Tomografia Computadorizada/métodos , Valor Preditivo dos Testes , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Prognóstico , Sistema de Registros
10.
Catheter Cardiovasc Interv ; 103(2): 367-375, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37890014

RESUMO

AIMS: Characterize the impact of residual tricuspid regurgitation (TR) on right ventricle (RV) remodeling and clinical outcomes after transcatheter tricuspid valve intervention. METHODS: We performed a single-center retrospective analysis of transcatheter tricuspid valve repair (TTVr) or replacement (TTVR) patients. The primary outcomes were longitudinal tricuspid annular plane systolic excursion (TAPSE), fractional area change (FAC), pulmonary artery systolic pressure (PASP), and RV dimensions (RVd). We used multivariable linear mixed models to evaluate association with replacement versus repair and degree of TR reduction with changes in these echo measures over time. Multivariable Cox regression was used to identify associations between changes in these echo measures and a composite clinical outcome of death, heart failure hospitalization, or re-do tricuspid valve intervention. RESULTS: We included a total of 61 patients; mean age was 77.5 ± 11.7 and 62% were female. TTVR was performed in 25 (41%) and TTVr in 36 (59%). Initially, 72% (n = 44) had ≤ severe TR and 28% (n = 17) had massive or torrential TR. The median number of follow up echos was 2: time to 1st follow-up was 50 days (interquartile range [IQR]: 20, 91) and last follow-up was 147 (IQR: 90, 327). Median TR reduction was 1 (IQR: 0, 2) versus 4 (IQR: 3, 6) grades in TTVr versus TTVR (p < 0.0001). In linear mixed modeling, TTVR was associated with decline in TAPSE and PASP, and TR reduction was associated with decreased RVd. In multivariable Cox regression, greater RVd was associated with the clinical outcome (hazard ratio: 9.27, 95% confidence interval: 1.23-69.88, p = 0.03). CONCLUSION: Greater TR reduction is achieved by TTVR versus TTVr, which is in turn associated with RV reverse remodeling. RV dimension in follow-up is associated with increased risk of a composite outcome of death, heart failure hospitalization, or re-do tricuspid valve intervention.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Estudos Retrospectivos , Remodelação Ventricular , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia
11.
Circ Cardiovasc Interv ; 16(11): e012966, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37988437

RESUMO

Transcatheter aortic valve replacement (TAVR) is increasingly being performed in younger and lower surgical risk patients. Reintervention for failed transcatheter heart valves will likely increase in the future as younger patients are expected to outlive the initial bioprosthesis. While redo-TAVR has emerged as an attractive and less invasive alternative to surgical explantation (TAVR-explant) to treat transcatheter heart valve failure, it may not be feasible in all patients due to the risk of coronary obstruction and impaired coronary access. Conversely, TAVR-explant can be offered to most patients who are surgical candidates, but the reported outcomes have shown high mortality and morbidity. This review provides the latest evidence, current challenges, and future directions on redo-TAVR and TAVR-explant for transcatheter heart valve failure, to guide aortic valve reintervention and facilitate patients' lifetime management of aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos
12.
Ann Thorac Surg ; 116(5): 908-932, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37804270

RESUMO

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/etiologia , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Comorbidade , Cateterismo Cardíaco/efeitos adversos , Índice de Gravidade de Doença
13.
J Am Coll Cardiol ; 82(17): 1711-1735, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37804294

RESUMO

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/etiologia , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Índice de Gravidade de Doença
15.
Eur Heart J ; 44(43): 4508-4532, 2023 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-37793121

RESUMO

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/etiologia , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Índice de Gravidade de Doença
16.
Am J Cardiol ; 205: 311-320, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37633066

RESUMO

In severe aortic stenosis (AS), there are conflicting data on the prognostic implications of left ventricular (LV) hypertrophy (LVH). We aimed to characterize the LV geometry, myocardial matrix structural changes, and prognostic stratification using cardiac magnetic resonance imaging (CMR) and echocardiography in subjects with severe AS with and without LVH. Consecutive patients who had severe isolated AS and sufficient quality echocardiography and CMR within 6 months of each other were evaluated for LVH, cardiac structure, morphology, and late gadolinium-enhancement imaging. Kaplan-Meier curves, linear models, and proportional hazards models were used for prognostic stratification. There were 93 patients enrolled (mean age 74 ± 11 years, 48% female), of whom 38 (41%) had a normal LV mass index (LVMI), 41 (44%) had LVH defined at CMR by LVMI >2 SD higher than normal, and 14 (15% of the total) with >4 SD higher than the reference LVMI (severely elevated). The Society of Thoracic Surgeons scores were similar among the LVMI groups. Compared with those with normal LVMI, patients with LVH had higher LV end-diastolic and end-systolic volumes, increased late gadolinium-enhancement burden, and lower LV ejection fraction. Most notably, CMR feature-tracking global radial strain, 2-dimensional speckle-tracking echocardiography global longitudinal strain, and left atrial reservoir function were significantly worse. On the survival analyses, LVMI was not associated with a composite of all-cause mortality and/or heart failure hospitalization. In conclusion, compared with normal LVMI, elevated LVMI was not associated with a higher risk of adverse outcomes.


Assuntos
Estenose da Valva Aórtica , Gadolínio , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Miocárdio , Ecocardiografia , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/diagnóstico por imagem
18.
Struct Heart ; 7(3): 100164, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37273856

RESUMO

Background: Cardiac computed tomography angiography was used to identify anatomical characteristics of the aortic root in patients with severe aortic regurgitation (AR) as compared to those with aortic stenosis (AS) to judge feasibility of transcatheter aortic valve replacement (TAVR) with the JenaValve Trilogy system. Methods: Cardiac computed tomography angiography was performed prior to planned TAVR for 107 patients with severe AR and 92 patients with severe AS. Measurements related to aortic root and coronary artery anatomy were obtained and compared between groups. Perimeter >90 mm and aortic annulus angle â€‹>70 degrees were defined as the theoretical exclusion criteria for TAVR. A combination of sinus of Valsalva diameter <30 mm and coronary height <12 mm was defined as high risk for coronary occlusion. Results: The mean age of patients in the AR group was 74.9 ± 11.2 years, 46% were women, and the mean Society of Thoracic Surgeons risk score for mortality was 3.6 ± 2.1. Comparatively, the mean age of patients in the AS group was 82.3 ± 5.53 years, 65% were women, and the mean Society of Thoracic Surgeonsrisk score was 5.5 ± 3.3. Annulus area, perimeter, diameter, and angle were larger in patients with severe AR. Sinus of Valsalva diameters and heights were larger in patients with severe AR. More AR patients were excluded based on perimeter (14 vs. 2%) and annulus angle (6 vs. 1%). More AS patients exhibited high-risk anatomy for left main coronary occlusion (21 vs. 7%) and right coronary occlusion (14 vs. 3%). The maximum dimension of the ascending aorta was larger in patients with severe AR (39 vs. 35 mm). The percentage of referred AR patients with significant aortopathy requiring surgical intervention was very low (only 1 AR patient with ascending aorta diameter >5.5 cm). Conclusions: A significantly larger proportion of patients with severe AR are excluded from TAVR as compared to AS due to large aortic annulus size and steep annulus angulation. By far the most prevalent excluding factor is aortic annulus size, with fewer patients excluded due to angulation. AR patients have lower-risk anatomy for coronary occlusion. Larger transcatheter valve sizes and further delivery system modifications are required to treat a larger proportion of AR patients.

19.
JACC Cardiovasc Interv ; 16(9): 1024-1035, 2023 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-37164599

RESUMO

BACKGROUND: Whether an eruptive or noneruptive target lesion calcified nodule (CN) portends worse acute and long-term clinical outcomes after stenting has not been established. OBJECTIVES: The authors sought to compare acute and long-term clinical outcomes in eruptive CN vs noneruptive CN morphology. METHODS: Using optical coherence tomography, an eruptive CN was defined as an accumulation of small calcium fragments protruding and disrupting the overlying fibrous cap, typically with small amount of thrombus. A noneruptive CN was defined as an accumulation of small calcium fragments with a smooth intact fibrous cap without an overlying thrombus. The primary endpoint was target lesion failure (TLF) including cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization in patients with ≥6-month follow-up. RESULTS: Among 3,231 patients with evaluable pre- and postintervention OCT, 236 patients had lesions with CNs (7.3%). After eliminating 4 secondary lesions and 6 patients without ≥6-month follow-up, 126 (54.8%) lesions with eruptive CNs and 104 (45.2%) lesions with noneruptive CNs formed the current report. Compared with noneruptive CNs, eruptive CNs were independently associated with greater stent expansion (89.2% ± 18.7% vs. 81.5% ± 18.9%; P = 0.003) after adjusting for morphologic and procedural factors. At 2 years, eruptive CNs trended toward more TLF compared with noneruptive CNs (Kaplan-Meier estimates, 19.8% vs 12.5%; P = 0.11) and significantly more target lesion revascularization (18.3% vs 9.6%; P = 0.04). In the adjusted model, eruptive CNs were independently associated with 2-year TLF (HR: 2.07; 95% CI: 1.01-4.50; P = 0.048). CONCLUSIONS: Compared with noneruptive CN morphology, lesions with an eruptive CN appearance on optical coherence tomography had a worse poststent long-term clinical outcome despite better acute stent expansion.


Assuntos
Doença da Artéria Coronariana , Exantema , Intervenção Coronária Percutânea , Trombose , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Cálcio , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Stents , Fibrose
20.
Echocardiography ; 40(2): 137-142, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36647761

RESUMO

In this case report, we illustrate the contemporary use of multi-modality cardiac imaging and three-dimensional (3D)-printing in the diagnosis and precise surgical planning of a large ventricular aneurysm with an extensive thrombus burden after myocardial infarction. We further discuss an integrated multimodality approach in the evaluation of ventricular outpouchings.


Assuntos
Falso Aneurisma , Aneurisma Cardíaco , Infarto do Miocárdio , Humanos , Falso Aneurisma/diagnóstico por imagem , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/etiologia , Infarto do Miocárdio/complicações , Imagem Multimodal , Impressão Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...