Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pak Med Assoc ; 70(5): 930-934, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32400757

RESUMO

Whipple's pancreatoduodenectomy is a complex surgical procedure and any aberrant arterial anatomy may have serious surgical implications. The objective of our study was to analyse the frequency of aberrant hepatic artery and compare the outcomes in patients with normal anatomy. Clinical data and computed tomography scans of 45 consecutive patients who underwent Whipple's procedure from 2007 to 2016 were reviewed. Group 'A' included patients with aberrant hepatic artery while group 'B' with normal anatomy. Aberrant hepatic artery was present in 11 (24%) patients and type V was the most common variant (n=5, 45%). Morbidity rate in group A was 82% and group B was 62% (p= 0.288), while 30-day mortality rate was 18% and 9% respectively (p=0.582). There was no difference in the oncological clearance in both the groups. Aberrant hepatic artery does not seem to influence the morbidity, mortality and tumour resection margins in patients undergoing Whipple's procedure.


Assuntos
Artéria Hepática , Complicações Intraoperatórias , Neoplasias Pancreáticas , Pancreaticoduodenectomia , Complicações Pós-Operatórias , Variação Anatômica , Feminino , Artéria Hepática/anatomia & histologia , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/lesões , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/cirurgia , Pancreaticoduodenectomia/efeitos adversos , Pancreaticoduodenectomia/métodos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Fluxo Sanguíneo Regional , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos
2.
J Coll Physicians Surg Pak ; 30(3): 327-329, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32169147

RESUMO

A 78-year female presented with the complain of per rectal fresh bleeding for 4 days. She was known to have diabetes and hypertension, 3 weeks back. She had an episode of left middle cerebral artery (MCA) stroke. After stroke, she suffered from upper limb weakness and aphasia. At the time of presentation, her vitals showed blood pressure of 118/52 mmHg, O2 saturation of 98%, temperature: 37°C, respiratory rate (RR) of 20/min, and heart rate (HR) of 90 bpm. After achieving hemodynamic stability, she was transferred to radiology department. Her presenting complain of active rectal bleeding was managed by interventional radiologist using angiographic embolisation. In this patient, it was found pooling of blood in a retrograde fashion in the sigmoid colon. Bleeding was initially believed to be coming from sigmoid arteries seen on images of CT scan and colonoscopy. However, arteriography showed that source of bleeding was from middle and inferior rectal arteries that originated from left internal iliac artery. The intervention radiology (IR) team had to put in extensive effort to locate and perform therapeutic embolisation.


Assuntos
Embolização Terapêutica , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/terapia , Artéria Ilíaca/anormalidades , Artéria Ilíaca/diagnóstico por imagem , Reto/irrigação sanguínea , Idoso , Angiografia , Feminino , Hemorragia Gastrointestinal/etiologia , Humanos , Reto/diagnóstico por imagem
3.
Abdom Radiol (NY) ; 43(5): 1254-1261, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28828512

RESUMO

PURPOSE: To ascertain the accuracy and reliability of tablet as an imaging console for detection of radiological signs of acute appendicitis [on focused appendiceal computed tomography (FACT)] using Picture Archiving and Communication System (PACS) workstation as reference standard. METHODS: From January, 2014 to June, 2015, 225 patients underwent FACT at our institution. These scans were blindly re-interpreted by an independent consultant radiologist, first on PACS workstation and, two weeks later, on tablet. Scans were interpreted for the presence of radiological signs of acute appendicitis. Accuracy of tablet was calculated using PACS as reference standard. Kappa (κ) statistics were calculated as a measure of reliability. RESULTS: Of 225 patients, 99 had radiological evidence of acute appendicitis on PACS workstation. Tablet was 100% accurate in detecting radiological signs of acute appendicitis. Appendicoliths, free fluid, lymphadenopathy, phlegmon/abscess, and perforation were identified on PACS in 90, 43, 39, 10, and 12 scans, respectively. There was excellent agreement between tablet and PACS for detection of appendicolith (к = 0.924), phlegmon/abscess (к = 0.904), free fluid (к = 0.863), lymphadenopathy (к = 0.879), and perforation (к = 0.904). CONCLUSIONS: Tablet computer, as an imaging console, was highly reliable and was as accurate as PACS workstation for the radiological diagnosis of acute appendicitis.


Assuntos
Apendicite/diagnóstico por imagem , Computadores de Mão/normas , Sistemas de Informação em Radiologia , Doença Aguda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Apêndice/diagnóstico por imagem , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
4.
J Pak Med Assoc ; 67(6): 923-925, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28585594

RESUMO

Severe pancreatitis occurs in approximately 15-25% of patients with acute pancreatitis. The objective of our study was to compare the CT Severity Index (CTSI) with a clinical score (BISAP score) to predict severity of acute pancreatitis. Forty-eight consecutive patients with acute pancreatitis who underwent contrast enhanced CT scan within 72 hours of presentation were included. Results of our study showed that both CTSI and BISAP score were reliable predictors of mortality (p value = 0.019 and <0.001 respectively) and need for mechanical ventilation (p value = .002 and .006 respectively). Positive predictive value of CTSI to predict recovery without intervention was 91.4% as compared to 78% for that of BISAP score. Receiver Operating Characteristics (ROC) Curves showed CT scan was superior to BISAP Score in predicting need of percutaneous or surgical intervention. Early CT scan may be utilized for prediction of clinical course of patients with acute pancreatitis.


Assuntos
Pancreatite/diagnóstico por imagem , Doença Aguda , Adulto , Cardiotônicos/uso terapêutico , Meios de Contraste , Procedimentos Cirúrgicos do Sistema Digestório , Diagnóstico Precoce , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pancreatite/mortalidade , Pancreatite/terapia , Valor Preditivo dos Testes , Prognóstico , Curva ROC , Respiração Artificial , Índice de Gravidade de Doença , Síndrome de Resposta Inflamatória Sistêmica , Tomografia Computadorizada por Raios X
5.
J Coll Physicians Surg Pak ; 14(10): 601-4, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15456549

RESUMO

OBJECTIVE: To evaluate the value of ultrasound in the diagnosis and management strategies of intrauterine growth retardation. DESIGN: A descriptive study. PLACE AND DURATION OF STUDY: Radiology Department, Aga Khan University Hospital, Karachi, from April 1998 to August 1999. PATIENTS AND METHODS: The study population comprised of 206 subjects evaluated for suspected intrauterine growth retardation. Grey scale as well as Doppler ultrasound findings were evaluated and compared against post-natal outcome. RESULTS: One hundred and eight out of 206 subjects showed positive imaging results with 40 false positive and 20 false negative subjects. The sensitivity, specificity, positive predictive and negative predictive values were 77.8%, 66.1%, 55.6%, and 45.1% respectively. Forty subjects showed false positive results on imaging (low biophysical profile score and Grey scale biometry discrepancy) while 20 of the subjects showed false negative results (normal on US imaging) when compared with postnatal neonatal body weight criteria. Twenty-two subjects had oligohydramnios with amniotic fluid index below 5 percentile for their respective gestational ages (20%) out of 108. CONCLUSION: Obstetric and Doppler ultrasound is an accurate method for diagnosis and management of fetal growth retardation.


Assuntos
Retardo do Crescimento Fetal/diagnóstico por imagem , Retardo do Crescimento Fetal/terapia , Ultrassonografia Pré-Natal , Adolescente , Adulto , Aorta/diagnóstico por imagem , Aorta/embriologia , Fenômenos Biofísicos , Biofísica , Feminino , Humanos , Gravidez , Sensibilidade e Especificidade , Ultrassonografia Doppler , Artérias Umbilicais/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...