Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 9(1): 5103, 2019 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-30911104

RESUMO

A novel method to drive and manipulate fluid in a contactless way in a microelectrode-microfluidic system is demonstrated by combining the Lorentz and magnetic field gradient forces. The method is based on the redox-reaction [Fe(CN)6]3-/[Fe(CN)6]4- performed in a magnetic field oriented perpendicular to the ionic current that crosses the gap between two arrays of oppositely polarized microelectrodes, generating a magnetohydrodynamic flow. Additionally, a movable magnetized CoFe micro-strip is placed at different positions beneath the gap. In this region, the magnetic flux density is changed locally and a strong magnetic field gradient is formed. The redox-reaction changes the magnetic susceptibility of the electrolyte near the electrodes, and the resulting magnetic field gradient exerts a force on the fluid, which leads to a deflection of the Lorentz force-driven main flow. Particle Image Velocity measurements and numerical simulations demonstrate that by combining the two magnetic forces, the flow is not only redirected, but also a local change of concentration of paramagnetic species is realized.

2.
Anal Chem ; 90(13): 7862-7870, 2018 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-29873231

RESUMO

We present the merging of two technologies to perform continuous high-resolution fluorescence imaging of cellular suspensions in a deep microfluidics chamber with no moving parts. An epitaxial light sheet confocal microscope (e-LSCM) was used to image suspensions enabled by fluid transport via redox-magnetohydrodynamics (R-MHD). The e-LSCM features a linear solid state sensor, oriented perpendicular to the direction of flow, that can bin the emission across different numbers of pixels, yielding electronically adjustable optical sectioning. This, in addition to intensity thresholding, defines the axial resolution, which was validated with an optical phantom of polystyrene microspheres suspended in agarose. The linear fluid speed within the microfluidics chamber was uniform (0.16-2.9%) across the 0.5-1.0 mm lateral field of view (dependent upon the chosen magnification) with continuous acquisition. Also, the camera's linear exposure periods were controlled to ensure an accurate image aspect ratio across this span. Poly(3,4-ethylenedioxythiophene) (PEDOT) was electrodeposited as an immobilized redox film on electrodes of a chip for R-MHD, and the fluid flow was calibrated to specific linear speeds as a function of applied current. Images of leukocytes stained with acridine orange, a fluorescent, amphipathic vital dye that intercalates DNA, were acquired in the R-MHD microfluidics chamber with the e-LSCM to demonstrate imaging of biological samples. The combination of these technologies provides a miniaturizable platform for large sample volumes and high-throughput, image-based analysis without the requirement of moving parts, enabling development of robust, point-of-care image cytometry.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes/química , Hidrodinâmica , Citometria por Imagem/métodos , Luz , Fenômenos Magnéticos , Microscopia Confocal/métodos , Polímeros/química , Eletroquímica , Humanos , Processamento de Imagem Assistida por Computador , Leucócitos/citologia , Oxirredução
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...