Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Europace ; 25(3): 940-947, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36638366

RESUMO

AIMS: There is little evidence of the impact of syncope in implantable cardioverter-defibrillator (ICD) patients in routine community hospital care. This single-centre retrospective study sought to evaluate the incidence and prognostic significance of syncope in consecutive ICD patients. METHODS AND RESULTS: Data were collected on consecutive patients undergoing first ICD implantation between January 2009 and December 2019. The primary endpoints were the first occurrence of all-cause syncope, all-cause mortality, and all-cause hospitalization. Multivariate Cox proportional hazard models were used to identify risk factors associated with syncope and to analyse the subsequent risk of mortality and hospitalization. 1003 patients (58% primary prevention) were included in the final analysis. During a mean follow-up of 1519 ± 1055 days, 106 (10.6%) experienced syncope, 304 died (30.3%), and 477 (47.5%) were hospitalized for any cause. In an analysis adjusted for baseline variables, the first occurrence of syncope was associated with a significantly increased risk of mortality (HR 2.82, P < 0.001) and the first occurrence of hospitalization (HR 2.46, P = 0.002). CONCLUSION: Syncope in ICD recipients is common and associated with a poor prognosis irrespective of baseline variables and ICD programming. The occurrence of syncope is associated with a significant increase in the risk of mortality and hospitalization.


Assuntos
Desfibriladores Implantáveis , Humanos , Estudos Retrospectivos , Desfibriladores Implantáveis/efeitos adversos , Prognóstico , Fatores de Risco , Síncope/diagnóstico , Síncope/epidemiologia , Síncope/etiologia
3.
Pacing Clin Electrophysiol ; 44(12): 1995-2004, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34672370

RESUMO

INTRODUCTION: Generic ICD programming, where shock-reduction programming is extrapolated from trials of one manufacturer to another, may reduce non-essential ICD therapies beyond that seen in randomized trials. However, the benefits and risks are unknown. The purpose of this retrospective cohort study was to evaluate the impact of a standardized programming protocol, based on generic programming, across manufacturers. METHODS: We included all new ICDs in a single center (2009-2019). In 2013 a standardized programming protocol based on generic programming was introduced, incorporating high detection rates (200 bpm for primary prevention) and long detection (30/40 or equivalent in VF zone) for all patients. Patients were classified into three groups based on implant programming: pre-guideline (PS), post-guideline and guideline compliant (GC) and post-guideline but not guideline compliant (NGC). The end-points were the first occurrence of any device therapy (ATP or shock), ICD shock, syncope and all-cause mortality. Survival analysis was used to evaluate outcomes. RESULTS: 1003 patients were included (mean follow-up 1519 ± 1005 days). In primary prevention patients (n = 583) freedom from ICD therapy (91.5% vs. 73.6%, p < .001) or shock (94.7% vs 84.8%, p = .02) were significantly higher in GC compared to PS patients, without significant increase in syncope or mortality. In secondary prevention patients (n = 420) freedom from any ICD therapy or any shock were non-significantly higher in GC compared to PS patients, without an increase in syncope or mortality. CONCLUSIONS: In primary prevention patients a standardized programming protocol, incorporating generic programming, reduced the burden of ICD therapy without an increase in adverse outcomes.


Assuntos
Algoritmos , Desfibriladores Implantáveis/normas , Desenho de Prótese , Idoso , Feminino , Fidelidade a Diretrizes , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária , Estudos Retrospectivos , Prevenção Secundária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...