Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 660, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36635481

RESUMO

The fall armyworm (FAW) Spodoptera frugiperda is thought to have undergone a rapid 'west-to-east' spread since 2016 when it was first identified in western Africa. Between 2018 and 2020, it was recorded from South Asia (SA), Southeast Asia (SEA), East Asia (EA), and Pacific/Australia (PA). Population genomic analyses enabled the understanding of pathways, population sources, and gene flow in this notorious agricultural pest species. Using neutral single nucleotide polymorphic (SNP) DNA markers, we detected genome introgression that suggested most populations in this study were overwhelmingly C- and R-strain hybrids (n = 252/262). SNP and mitochondrial DNA markers identified multiple introductions that were most parsimoniously explained by anthropogenic-assisted spread, i.e., associated with international trade of live/fresh plants and plant products, and involved 'bridgehead populations' in countries to enable successful pest establishment in neighbouring countries. Distinct population genomic signatures between Myanmar and China do not support the 'African origin spread' nor the 'Myanmar source population to China' hypotheses. Significant genetic differentiation between populations from different Australian states supported multiple pathways involving distinct SEA populations. Our study identified Asia as a biosecurity hotspot and a FAW genetic melting pot, and demonstrated the use of genome analysis to disentangle preventable human-assisted pest introductions from unpreventable natural pest spread.


Assuntos
Comércio , Spodoptera , Animais , Ásia , Austrália , Marcadores Genéticos , Spodoptera/genética , Genética Populacional , Fluxo Gênico , Polimorfismo de Nucleotídeo Único , Espécies Introduzidas
2.
Sci Rep ; 6: 39167, 2016 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-27991532

RESUMO

The white-backed planthopper, Sogatella furcifera (Horváth) (Hemiptera: Delphacidae), is a serious pest of rice in Asia. However, little is known regarding the migration of this pest insect from the Greater Mekong Subregion (GMS) including Cambodia, Laos, Myanmar (Burma), Thailand, and Vietnam, into China's Yunnan Province. To determine the migration patterns of S. furcifera in the GMS and putative secondary immigration inside China's Yunnan Province, we investigated the population genetic diversity, genetic structure, and gene flow of 42 S. furcifera populations across the six countries in the GMS by intensive sampling using mitochondrial genes. Our study revealed the potential emigration of S. furcifera from the GMS consists primarily of three major sources: 1) the S. furcifera from Laos and Vietnam migrate into south and southeast Yunnan, where they proceed to further migrate into northeast and central Yunnan; 2) the S. furcifera from Myanmar migrate into west Yunnan, and/or central Yunnan, and/or northeast Yunnan; 3) the S. furcifera from Cambodia migrate into southwest Yunnan, where the populations can migrate further into central Yunnan. The new data will not only be helpful in predicting population dynamics of the planthopper, but will also aid in regional control programs for this economically important pest insect.


Assuntos
DNA Mitocondrial/análise , Hemípteros/genética , Migração Animal , Animais , Sudeste Asiático , DNA Mitocondrial/genética , DNA Mitocondrial/isolamento & purificação , Complexo IV da Cadeia de Transporte de Elétrons/genética , Fluxo Gênico , Variação Genética , Haplótipos , Oryza/parasitologia , Análise de Sequência de DNA
3.
Biomed Chromatogr ; 25(1-2): 124-35, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20842699

RESUMO

2,4-D, dicamba and 4-CPA with auxin-like activity have been intensively used in agriculture, for the control of unwanted broadleaf weeds. An analytical method involving HPLC coupled with UVD was developed for the simultaneous analysis of these three analytes in Chinese cabbage, apple and pepper fruits (representative non-fatty samples) and brown rice and soybean (representative fatty samples) using liquid-liquid partitioning and column cleanup procedures. The residues were confirmed via tandem mass spectrometry (MS/MS) in ion electrospray ionization (ESI) mode. The standard curves were linear over the range of the tested concentrations (0.25-10 microg/mL), as shown by a marked linearity in excess of 0.9999 (r(2) ). The average recoveries (mean, n = 3) ranged from 94.30 to 102.63 in Chinese cabbage, from 94.76 to 108.47 in apple, from 97.52 to 102.27 in pepper, from 76.19 to 101.90 in brown rice, and from 74.60 to 107.39 in soybean. The relative standard deviations (RSDs) were <9% in all tested matrices. The limits of detection and quantitation were 0.006 and 0.02 mg/kg, respectively. Samples purchased from local markets were analyzed to evaluate the applicability of the methods developed herein. The concentration of the 2,4-D residue was measured at 0.102 mg/kg in the soybean sample; however, this level is exactly the same MRL set by the Korea Food and Drug Administration. This developed method deserves full and complete consideration, as it clearly displays the sensitivity, accuracy and precision required for residue analysis of 2,4-D, dicamba and 4-CPA in food crops.


Assuntos
Ácido 2,4-Diclorofenoxiacético/análise , Cromatografia Líquida de Alta Pressão/métodos , Dicamba/análise , Análise de Alimentos/métodos , Resíduos de Praguicidas/análise , Espectrometria de Massas em Tandem/métodos , Ácido 2,4-Diclorofenoxiacético/análogos & derivados , Ácido 2,4-Diclorofenoxiacético/química , Dicamba/química , Frutas/química , Modelos Lineares , Oryza/química , Resíduos de Praguicidas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Toxicol Res ; 26(2): 149-55, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24278518

RESUMO

The pesticide trichlorfon is readily degraded under experimental conditions to dichlorvos. A method has therefore been developed by which residues of trichlorfon in milk are determined as dichlorvos, using gas chromatography with µ-electron capture detection. The identification of dichlorvos was confirmed by mass spectrometry. Milk was extracted with acetonitrile followed by centrifugation, freezing lipid filtration, and partitioning into dichloromethane. The residue after partitioning of dichloromethane was dissolved in ethyl acetate for gas chromatography. Recovery concentration was determined at 0.5, 1.0, and 2.0 of times the maximum permitted residue limits (MRLs) for trichlorfon in milk. The average recoveries (n = 6) ranged from 92.4 to 103.6%. The repeatability of the measurements was expressed as relative standard deviations (RSDs) ranging from 3.6%, to 6.7%. Limit of detection (LOD) and limit of quantification (LOQ) were 3.7 and 11.1 µg/l, respectively. The accuracy and precision (expressed as RSD) were estimated at concentrations from 25 to 250 µg/l. The intra- and inter-day accuracy (n = 6) ranged from 89.2%to 91% and 91.3% to 96.3%, respectively. The intra- and inter-day precisions were lower than 8%. The developed method was applied to determine trichlorfon in real samples collected from the seven major cities in the Republic of Korea. No residual trichlorfon was detected in any samples.

5.
J Sep Sci ; 32(2): 244-51, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19107766

RESUMO

The principal goal of this work was to develop an efficient method for the simultaneous determination of four pyrethroid (PYR) insecticides, cyfluthrin, cyhalothrin, cypermethrin, and deltamethrin, in porcine muscle and pasteurized milk using liquid-liquid extraction (LLE). Sample extraction was carried out with and without additional column cleanup procedures, and the final determination was made using GC with electron-capture detector (ECD). The pesticide identity was confirmed using GC-MS in the SIM mode. Since there were minor differences between the extraction procedures, extraction without the additional cleanup procedure was used throughout the work. The method was validated by fortifying blank samples with half, two, and four times the maximum residue limit (MRL) of each PYR. The average recoveries (n = 6) ranged from 83.5 to 99.2% and 82.9 to 109% in porcine muscle and pasteurized milk, respectively. The repeatability of measurements expressed as RSDs, was in the range of 1.7-11.9 and 1.5-10.3% in porcine muscle and pasteurized milk, respectively. The LODs ranged from 3.3 to 9 and 3 to 8.1 ppm, whereas the LOQs ranged from 10 to 27.4 and 9 to 24.6 ppm, in porcine muscle and pasteurized milk, respectively. The applicability of the method was demonstrated by analyzing real samples collected from major cities in the Republic of Korea. No residues of the selected pesticides were detected in any of the samples.


Assuntos
Análise de Alimentos/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Leite/química , Músculos/química , Resíduos de Praguicidas/análise , Resíduos de Praguicidas/química , Piretrinas/análise , Piretrinas/química , Animais , Elétrons , Temperatura Alta , Carne/análise , Suínos
6.
Anal Chim Acta ; 631(1): 108-15, 2009 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-19046687

RESUMO

Since its extensive development in the early 1980s, SFE has attracted considerable attention as a sample-preparation procedure. However, other different sample preparation procedures, including precipitation, liquid- and/or solid-phase extraction in biological fluids, also remain in use. In this investigation, SFE was introduced to isolate and identify orbifloxacin from plasma and milk. Four parameters, including the temperature and the pressure of supercritical fluid, modifier ratios, and dynamic extraction time, were evaluated and optimized to obtain the best yield of the analyte from the biological fluids. Determinations of the orbifloxacin (OBFX) in the extracts were carried out using HPLC-FLD. The optimum conditions of the extraction process that yielded the maximum analyte extraction efficiencies were 150 degrees C vs. 60 degrees C, 250 kg cm(-2), 30% vs. 35% methanol, and 40 min vs. 20 min, for plasma and milk, respectively. The linearity of the calibration curves as well as the instrument LODs/LOQs were evaluated. Good linearity (at least r(2) > or = 0.999) of the calibration curves was obtained over the range from 0.2 to 0.01 microg mL(-1). The method showed a good recovery rate (74.2-127.73%) and precision (RSDs: 1.64-20%). The instrumental LOD and LOQ values were 0.004 microg mL(-1) vs. 0.01 microg mL(-1) or 0.006 microg mL(-1) vs. 0.02 microg mL(-1), for plasma and milk, respectively. The method was successfully applied to estimate the pharmacokinetic variables of orbifloxacin in lactating does. To the best of our knowledge, this is the first time that SFE has been applied to isolate an antimicrobial agent from biological fluids. This method is promising for clinical applications and for pharmacokinetic studies of various pharmaceuticals in biological fluids.


Assuntos
Métodos Analíticos de Preparação de Amostras/métodos , Anti-Infecciosos/análise , Anti-Infecciosos/farmacocinética , Ciprofloxacina/análogos & derivados , Leite/química , Animais , Anti-Infecciosos/sangue , Anti-Infecciosos/isolamento & purificação , Cromatografia Líquida de Alta Pressão , Cromatografia com Fluido Supercrítico , Ciprofloxacina/análise , Ciprofloxacina/sangue , Ciprofloxacina/isolamento & purificação , Ciprofloxacina/farmacocinética , Cervos , Feminino , Química Verde , Injeções Intramusculares , Injeções Intravenosas , Cinética , Lactação , Pressão , Reprodutibilidade dos Testes , Temperatura , Fatores de Tempo
7.
J Sep Sci ; 31(22): 3847-56, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18985668

RESUMO

The current study was undertaken to validate the performance for the determination of both TBA and beta-trenbolone (beta-TB) residues in porcine muscle at concentrations required to monitor compliance with the maximum residue limit (MRL). The method involves a one phase liquid-liquid extraction, cleanup with low-temperature fat precipitation, separation of the respective compounds by HPLC on a Capcell pak C(18) column, use of a methanol-water isocratic system as an eluent, and measurement by UV absorbance detection at 340 nm. Both compounds were confirmed using LC-MS/MS with electrospray interface (ESI) and a triple quadrupole (QqQ) analyzer. The method was found to be precise and accurate, with a linearity range of 1-10 microg/kg (r(2) >0.973). The intra- and interday precision showed good reproducibility with RSDs < or =13.25%. The LODs were 0.12 and 0.22 microg/kg, and the LOQs were 0.37 and 0.66 microg/kg, for TBA and beta-TB, respectively. The applicability of the method was demonstrated by analyzing real samples collected from major cities in the Republic of Korea. No residues of the selected compounds were detected in any of the samples. The advantages of our method are that it is: selective, sensitive, requires a short time for analysis (13 min), and performs simple sample extraction and clean-up procedure with low-temperature fat precipitation as compared to the previously published methods.


Assuntos
Anabolizantes/análise , Cromatografia Líquida de Alta Pressão/métodos , Resíduos de Drogas/análise , Músculo Esquelético/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrofotometria Ultravioleta/métodos , Espectrometria de Massas em Tandem/métodos , Acetato de Trembolona/análogos & derivados , Animais , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos , Acetato de Trembolona/análise
8.
Biomed Chromatogr ; 22(6): 581-9, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18205138

RESUMO

This study was undertaken to investigate whether an additional column clean-up procedure can affect the accuracy of an analytical method developed for the determination of imidacloprid residues in Chinese cabbage. Thereafter, the residue levels and the degradation rates of imidacloprid were investigated in experimental Chinese cabbage plots after treatment with two different commercial formulations: emulsifiable concentrate (EC) and wettable powder (WP). The analyte was determined using high-performance liquid chromatography-ultraviolet detection (HPLC-UVD) and confirmed by high-performance liquid chromatography-mass spectrometry (HPLC-MS) in the select ion-monitoring mode. The mean recoveries ranged from 75.34 to 98.00% and 96.95 to 100.97%, with relative standard deviations of 0.86-4.14 and 1.22-3.52%, in samples treated with and without additional column clean-up procedures, respectively. The minimum detectable amount of imidacloprid was 4 ng, while the limits of detection and quantitation were 0.2 and 0.5 ppm, respectively. The degradation of pesticide was monitored throughout a period of 13 days under greenhouse conditions. Although the behaviors of the EC and WP formulations appear to be similar, the absolute residue levels obtained with EC and WP treatments differed slightly. When imidacloprid formulations were applied (as foliar treatments) according to the recommended rate, the final residues (13 days post-treatment) in Chinese cabbage were much lower than the maximum residue limit (MRL = 3.5 ppm) established by the Korean Food and Drug Administration. Taken together, our study suggests that the analysis of imidacloprid can be performed without an additional column clean-up procedure, and the decline curve and the residue levels in Chinese cabbage could change if the same active ingredient is used in different formulations.


Assuntos
Brassica/química , Cromatografia Líquida de Alta Pressão/métodos , Imidazóis/análise , Inseticidas/análise , Nitrocompostos/análise , Resíduos de Praguicidas/análise , Extratos Vegetais/química , Neonicotinoides , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta
9.
Toxicol Res ; 24(1): 87-91, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32038781

RESUMO

The present study was conducted to monitor the level of triflumizole residues in fruits (apple and pear) and vegetable (cucumber) samples in order to assess risk posed by the presence of such residues to the consumer. Triflumizole was applied at a recommended dose rate to apple and pear pulps and to a cucumber sample. The samples were collected at harvesting time following several treatments (three and/or four treatments). Triflumizole was extracted with methanol and re-extracted into dichloromethane. The presence of triflumizole was determined by HPLC with UV detection at 238 nm following the cleanup of the extract by open preparative chromatographic column with Florisil. The versatility of this method was evidenced by its excellent linearity (> 0.999) in the concentration range between 0.2 and 4.0 mg/kg. The mean recoveries evaluated from the untreated samples spiked at two different fortification levels, 0.1 and 0.4 mg/kg, and ranged from 87.5 ± 0.0 to 93.3 ± 2.6 for the tested fruits and vegetable, respectively, and the repeatability (as relative standard deviation) from three repetitive determinations of recoveries were no larger than 6%. The calculated limit of detection was 0.02 mg/kg and the minimum detectable level of 4 ng for triflumizole was easily detected. When triflumizole was sprayed onto the apple trees three times at 50-40-30 and 40-30-21 days prior to harvesting and four times onto the pear trees at 40-30-21-14 days prior to harvesting, the mean residual amounts of 0.05 and 0.06 mg/kg for apples and pears, respectively, were not detected in all of the treatments. When the cucumber sample was fumigated four times at 7, 5, 3 and 1 day prior to harvesting, the mean residual amount was not detectable. Triflumizole can be used safely when sprayed (wettable powder, 30% active ingredient) and fumigated (10%) 4 times at 14 and 1 day prior to harvesting to protect the fruits and vegetable, respectively.

10.
Biomed Chromatogr ; 21(6): 602-9, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17385804

RESUMO

An analytical procedure using accelerated solvent extraction and gas chromatography with an electron capture detector has been optimized to simultaneously determine the residue of two insecticides (diazinon and EPN) and one fungicide (isoprothiolane) in polished rice and was confirmed by GC-mass spectrometry. Several parameters, including temperature, pressure, solvent ratio, cell size and cell cycle, were thoroughly investigated to find the optimal extraction conditions. The average recoveries of the three pesticides were between 82.7 and 126.4% at spiking levels of 0.1 and 0.5 ppm. The relative standard deviations were less than 7% for all of the recovery tests. The optimum accelerated solvent extraction operating conditions were 100 degrees C, 1500 atm, acetone-n-hexane (20:80 v/v) as the extraction solvent, two cycles, and a cell size of 33 ml. The total extraction time was approximately 20 min. The optimized procedure has also been applied to the determination of diazinon, isoprothiolane and EPN in real rice samples. In conclusion, accelerated solvent extraction was used for the first time for the analysis of diazinon, isoprothiolane and EPN in polished rice and offers the possibility of a fast and simple process for obtaining a quantitative extraction of the studied pesticides.


Assuntos
Contaminação de Alimentos/análise , Cromatografia Gasosa-Espectrometria de Massas , Oryza/química , Resíduos de Praguicidas/análise , Solventes/química , Cromatografia Líquida de Alta Pressão , Diazinon/química , Análise de Alimentos/métodos , Estrutura Molecular , Resíduos de Praguicidas/química , Resíduos de Praguicidas/isolamento & purificação , Ácido Fenilfosfonotioico, 2-Etil 2-(4-Nitrofenil) Éster/química , Extratos Vegetais/análise , Extratos Vegetais/química , Pressão , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura , Tiofenos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA