Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Oral Implantol ; 2023 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-37025055

RESUMO

Introduction This study aimed to assess the effect of slice thickness of 3D printer in fabrication of surgical guide (SG) on the accuracy of dental implant placement. Materials and Methods After preparation of two dry human mandibles, Cone-beam computed tomography (CBCT) scans were obtained, and the location and direction of implants in the edentulous ridge of the mandible were identified using Romexis software. Data in STL format were transferred to a 3D printer and two SGs with 50 µm and 100 µm thicknesses were fabricated for each mandible. Drilling was performed using two SGs. The pre- and post-intervention CBCT scans were superimposed to measure the magnitude of differences. The two groups were compared using the Mann-Whitney U test. Results No significant difference was noted in SGs with 50 and 100 µm thicknesses in the coronal and apical regions of the implants or the depth of drilling. However, the difference in angular deviation was statistically significant. Conclusion Considering the higher accuracy of SGs with 50 µm thickness (despite the presence of a significant difference in AD between the SGs with different thicknesses), it is recommended to use a SG with 50 µm thickness in cases where anatomical limitations exist.

2.
Front Dent ; 19: 27, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36458277

RESUMO

Congenital diffuse infiltrating lipomatosis of the face (CDIL-F) is a rare clinicopathological entity with an unknown etiology, in which mature adipose tissue infiltrates the soft tissue structures in one side, and causes considerable asymmetry. Herein, we report a case of CDIL-F who underwent many surgical procedures without definite diagnosis during 12 years. CDIL-F presents symptoms with various severity levels due to infiltration of adipose tissue that makes removal difficult. Thus, it is recommended to inform patients about the high rate of recurrence.

3.
Int Orthod ; 16(1): 73-81, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29459155

RESUMO

PURPOSE: The aim of the present study was to evaluate the effect of the carbamazepine and valproic acid on orthodontic tooth movement in male Wistar rats. METHODS: Evaluation of tooth movement after 21 days of drugs infusion was carried out by feeler gauge. Bone densitometry on lateral cephalograms was conducted on days 1 and 21. After dissection of the maxillae, histologic parameters were evaluated. RESULTS: Orthodontic tooth movement was accelerated in experimental groups rather than controls. Optical density was significantly increased in these groups. In histologic sections, mesioapical portion of the PDL (Periodontal Ligament) was wider in experimental groups. Also, distoapical portion of the PDL was wider only in valproic acid group. CONCLUSION: Valproic acid and carbamazepine can decrease the bone density which may induce the accelerated orthodontic tooth movement in rats.


Assuntos
Anticonvulsivantes/farmacologia , Densidade Óssea/efeitos dos fármacos , Carbamazepina/farmacologia , Técnicas de Movimentação Dentária , Ácido Valproico/farmacologia , Animais , Masculino , Ratos Wistar
5.
J Dent (Shiraz) ; 18(3): 201-206, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29034275

RESUMO

STATEMENT OF THE PROBLEM: Considering the high diagnostic accuracy and wide dynamic range of photostimulable phosphor plates (PSPs), they can be a good alternative for radiographic films. PURPOSE: This study was aimed to assess the effects of delay in scanning PSPs on the diagnostic accuracy of detection of approximal caries. MATERIALS AND METHOD: Radiographs from fifty-two extracted molar and premolar teeth were radiographed using DIGORA PSP (Soredex Corporation, Helsinki, Finland). The teeth were either intact or with non-cavitated approximal caries. The plates were scanned immediately (time zero) and at 10 min, 30 min, 60 min and 120 min after exposure. Sixty-five images were obtained and evaluated for presence or absence of approximal caries by two oral and maxillofacial radiologists and 2 restorative specialists. The diagnostic accuracy of approximal caries detection was measured using a 5-point rating scale. Definite presence of caries was confirmed using a stereomicroscope. Analysis of caries detection data was performed by calculating sensitivity and specificity using repeated measures with ANOVA. RESULTS: Significant differences were found in complete negative predictive value, absolute negative predictive value and complete dentine sensitivity value between different scan times (p< 0.05). These values were significantly different at 10 min, 60 min and 120 min (p< 0.05). However, immediate scan and 30 min delay were not significantly different (p> 0.05). The accuracy of approximal caries detection at 120 min was less than at 60 min and at 60 min was less than at 30 min. CONCLUSION: In order to detect approximal caries more accurately, DIGORA PSPs should be scanned within 30 min after exposure.

6.
J Dent (Tehran) ; 14(5): 282-291, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29296114

RESUMO

OBJECTIVES: This study aimed to assess the relation between dimensional changes and object location in the field of view (FOV) using cone beam computed tomography (CBCT). MATERIALS AND METHODS: A custom-made phantom was fabricated from base plate wax. To analyze the accuracy of measurements in horizontal and longitudinal dimensions, aluminum squares (0.5 mm thickness, 10×10 mm dimensions) were constructed and placed in three levels (upper, middle, and lower) and five positions (central, right, left, anterior and posterior). This phantom was scanned using Asahi, Planmeca and NewTom CBCT systems. CBCT scans were measured three times by use of their corresponding software. Statistical analysis was performed using one-way ANOVA, post-hoc test and two-way ANOVA (P<0.05). RESULTS: The differences between the mean horizontal dimensions of different systems were not significant (P=0.296). However, the differences between the mean longitudinal dimensions of different systems were significant (P=0.039). The differences between the different positions and the mean horizontal and longitudinal dimensions were significant (P<0.001, and P<0.001, respectively). The differences between the mean horizontal dimensions and different levels were not significant (P=0.51), but the differences between the mean longitudinal dimensions and different levels were significant (P<0.001). The interaction effect of level and position on the accuracy of horizontal and longitudinal measurements was significant (P<0.0001). CONCLUSIONS: We found statistically significant differences in most of our comparisons; however, these differences were not clinically significant. Therefore, CBCT could be an accurate device for measurement of dimensions of objects placed in different positions in the FOV.

7.
Histol Histopathol ; 32(7): 743-749, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27782295

RESUMO

Metabolic bone disease is a major issue in chronic liver disease. Increased production of nitric oxide (NO) and elevation of endogenous opioids have been suggested to occur during cholestasis/cirrhosis. We aimed to investigate the involvement of nitrergic and opioidergic systems in bone loss after bile-duct-ligation (BDL) in rats using optical density (OD) evaluation and histomorphometric analysis. BDL- and sham-operated (SO) rats received injections of 3 mg/kg Nω-Nitro-L-arginine methyl-ester-hydrochloride (L-NAME) as an NO-synthase inhibitor, 10 mg/kg naltrexone (NTX) as an opioid-receptors antagonist or saline once daily for 28 days. Lateral cephalometric radiographs were taken on days 0 and 28 and histomorphometric and biochemical indices were measured. Plasma levels of total bilirubin and alkaline-phosphate were markedly increased in BDL compared with SO rats (p≤0.05). Among the studied variables, osteoclast number/mm trabecular surface showed significant increase in BDL animals compared to controls, which was significantly reduced following NO-synthase inhibition (p≤0.05). Similarly, cortical area slightly decreased in BDL animals in comparison to controls, whereas both L-NAME and NTX significantly increased this variable. Following BDL, optical density increased in the skulls of cirrhotic animals and showed a significant decrease after blocking opioid-receptors (p≤0.05). Inhibition of NO-synthase and/or opioid receptors caused significant changes in OD and histomorphometric parameters in BDL rats, both in favor of reducing bone loss. If confirmed by further studies, it seems that manipulation of these systems might be able to improve bone problems in subjects with cholestasis/cirrhosis.


Assuntos
Ductos Biliares , Cirrose Hepática Biliar/diagnóstico por imagem , Cirrose Hepática Biliar/patologia , Óxido Nítrico Sintase/antagonistas & inibidores , Receptores Opioides/efeitos dos fármacos , Animais , Bilirrubina/sangue , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/patologia , Colestase/patologia , Inibidores Enzimáticos/farmacologia , Ligadura , Fígado/diagnóstico por imagem , Fígado/patologia , Masculino , NG-Nitroarginina Metil Éster/farmacologia , Naltrexona/farmacologia , Antagonistas de Entorpecentes/farmacologia , Ratos , Ratos Sprague-Dawley , Crânio/diagnóstico por imagem
8.
J Dent (Tehran) ; 13(2): 126-132, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27928241

RESUMO

OBJECTIVES: This study aimed to evaluate the location and characteristics of mental foramen, anterior loop and mandibular incisive canal using cone beam computed tomography (CBCT). MATERIALS AND METHODS: This retrospective cross-sectional study evaluated 200 mandibular CBCT scans for the location of mental foramen, anterior loop prevalence and mandibular incisive canal visibility, its mean length and distance to buccal and lingual plates and inferior border of the mandible. The effect of age and gender on these variables was also analyzed (P<0.05). RESULTS: Anterior loop and mandibular incisive canal were seen in 59.5% and 97.5% of the cases, respectively. The mean length of the mandibular incisive canal was 10.48±4.53mm in the right and 10.40±4.52mm in the left side. The mean distance from the endpoints of the canal to buccal plate was 3.63±1.73mm in the right and 3.66±1.45mm in the left side. These distances were 3.89±1.53mm in the right and 4.13±1.48mm in the left side to lingual plate and 9.98±2.07mm in the right and 8.62±1.97mm in the left side to the inferior border of the mandible. The distance from the endpoints of the canal to lingual plate was significantly different in the right and left sides. The distance from the endpoint of the canal to the buccal plate and inferior border of the mandible was significantly shorter in females (P=0.016), and had a weak, significant correlation with age (rsp=0.215, P=0.003). CONCLUSIONS: Due to variability in mandibular incisive canal length and high prevalence of anterior loop, CBCT is recommended before surgical manipulation of interforaminal region.

9.
J Dent (Tehran) ; 13(4): 287-294, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28127321

RESUMO

OBJECTIVES: Precise radiographic assessment of the nasopalatine canal is required to prevent implant failure. The purpose of the current study was to determine the three dimensional (3D) morphology, as well as the dimensions of the nasopalatine canal using cone beam computed tomography (CBCT). MATERIALS AND METHODS: In this descriptive cross-sectional study, maxillary CBCT images from 300 patients (150 men, 150 women) were retrospectively evaluated. Sagittal and coronal views were reviewed to determine the nasopalatine canal morphology and dimensions. The difference in canal dimensions between men and women was evaluated using the Student's t-test while the difference in canal morphology between the two sexes was assessed using Chi-square test. RESULTS: A total of 199 (66.3%) patients had type A canal (cylindrical without a branch), 69 (23%) had type B canal (a canal with a branch in the upper part), and 32 (10.7 %) had type C canal (a canal with a branch in the middle part). Incisive foramen diameter was 4.7±1.11mm on the sagittal section. Alveolar bone width in the anterior part of the canal was 12.3±1.7mm in the upper one third, 10.7±1.7mm in the middle one third, and 9.8±1.4mm in the lower one third. The angle of canal with palate was 109.5±5.7°. On the coronal sections, canal length was 14.1±3.0mm, incisive foramen diameter was 4.6±1.0mm, and canal diameter in the nasal floor was 5.1±1.0mm. CONCLUSIONS: Significant differences in canal morphology were observed among the patients and CBCT was useful in determining nasopalatine canal morphology and its dimensions before implant placement.

10.
J Dent (Tehran) ; 13(3): 143-150, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28392810

RESUMO

OBJECTIVES: The aim of this study was to assess the effect of tube current, kilovoltage peak (kVp), metal type, and the position of metal objects on metal artifacts in cone-beam computed tomography (CBCT) images. MATERIALS AND METHODS: Titanium and cobalt-chromium rods were fabricated and placed in a dry human mandible. Samples were scanned using a Promax 3D CBCT unit with different milli-amperages and kVp. The artifacts induced by metal objects were evaluated using the Image J software in four regions of interest (ROIs) on each image. RESULTS: A higher kVp decreased artifacts of the buccal surface of the rods in 97% of the cases (P=0.046) but did not affect the severity of artifacts between the two metal objects (P>0.05). Increasing the tube current had no effect on metal artifacts in 93% of the cases (P>0.05). Artifacts induced by a cobalt-chromium alloy were more severe than those with titanium (P<0.001). Artifacts were more intense in the buccal surface of anterior rods compared to the posterior rods (P<0.003). CONCLUSIONS: Tube voltage, metal type and the position of metal objects affected the severity of metal artifacts on CBCT images. The metal type had the greatest effect on metal artifact intensity in this study.

11.
J Dent (Tehran) ; 12(12): 882-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27559347

RESUMO

OBJECTIVES: Fluoxetine is a selective serotonin re-uptake inhibitor (SSRI) widely used for depression, bipolar disorder, anxiety and obsessive-compulsive disorder. The aim of this study was to assess the effect of fluoxetine on orthodontic tooth movement (OTM) in rats. MATERIALS AND METHODS: Forty-five male Wistar rats were randomly divided into three groups namely the control group (no medication), saline and fluoxetine dissolved in saline. In all groups, nickel titanium closed-coil spring was used between the left maxillary central incisor and first molar to exert 60g force at 2mm activation. Radiographs were taken at one and 21 days. After 21 days, the rats were sacrificed. The distance between the first and second molar teeth, optical density of bone, periodontal ligament (PDL) width, lacuna length and depth and number of osteoclasts were measured and compared among the groups. RESULTS: Tooth movement significantly increased in the fluoxetine group (P=0.005). No significant differences were found in osteoclast count (P=0.069). The PDL width in the mesioapical region of root was significantly different among the groups (P=0.015). Statistical analysis did not show significant differences in depth or length of lacunae in any examined part of the root (P>0.05). Bone densitometry results showed that in fluoxetine group, density of bone in all four areas (alveolar bone, hard palate, skull and mandibular bone) significantly decreased from day one to day 21 (P< 0.05). CONCLUSION: This study indicated that fluoxetine decreased bone density, which resulted in subsequently greater tooth movement in rats; however, further studies are needed on humans.

12.
Iran J Basic Med Sci ; 17(6): 448-53, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25140207

RESUMO

OBJECTIVES: Pantoprazole, is a proton pump inhibitor (PPI) prescribed for the treatment of upper gastrointestinal disorders, which in high doses has been suggested to decrease calcium absorption leading to hypocalcaemia and therefore osteoporosis. The aim of this study was to assess whether pantoprazol, could alter the rate of orthodontic tooth movement (OTM) in rats. MATERIALS AND METHODS: A time course study was established using 72 rats which were divided into six groups of 12 samples each (four: vehicle; eight: pantoprazole + vehicle). Pantoprazole at a dose of 200 mg/kg suspended in carboxymethyl cellulose (0.25 percent) was administered by a gastric tube. The upper incisors and first molars were ligated by a 5 mm nickel-titanium closed-coil spring to deliver an initial force of 60 g. Animals were euthanized two weeks after orthodontic treatment followed by assessment of tooth movement and histomorphometric evaluation of the detached maxillae. Lateral skull radiographs were obtained once a week, starting from the first day to the 6(th) week of the study. OTM and bone density data were analyzed using independent sample t-test and repeated measures ANOVA. RESULTS: No significant changes in OTM measurements and optical density were observed in vehicle-receiving animals during the study (P=0.994). OTM was significantly increased after six weeks pantoprazole therapy which continued until the 7(th) week of the experiment (P=0.007). Optical density significantly increased in the pantoprazole-treated rats after six weeks. CONCLUSION: Long term PPI therapy at high doses could lead to osteoporosis and enhanced OTM.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA