Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
JAMA ; 327(19): 1875-1887, 2022 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-35579641

RESUMO

Importance: Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical aortic valve replacement and is the treatment of choice for patients at high operative risk. The role of TAVI in patients at lower risk is unclear. Objective: To determine whether TAVI is noninferior to surgery in patients at moderately increased operative risk. Design, Setting, and Participants: In this randomized clinical trial conducted at 34 UK centers, 913 patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk due to age or comorbidity were enrolled between April 2014 and April 2018 and followed up through April 2019. Interventions: TAVI using any valve with a CE mark (indicating conformity of the valve with all legal and safety requirements for sale throughout the European Economic Area) and any access route (n = 458) or surgical aortic valve replacement (surgery; n = 455). Main Outcomes and Measures: The primary outcome was all-cause mortality at 1 year. The primary hypothesis was that TAVI was noninferior to surgery, with a noninferiority margin of 5% for the upper limit of the 1-sided 97.5% CI for the absolute between-group difference in mortality. There were 36 secondary outcomes (30 reported herein), including duration of hospital stay, major bleeding events, vascular complications, conduction disturbance requiring pacemaker implantation, and aortic regurgitation. Results: Among 913 patients randomized (median age, 81 years [IQR, 78 to 84 years]; 424 [46%] were female; median Society of Thoracic Surgeons mortality risk score, 2.6% [IQR, 2.0% to 3.4%]), 912 (99.9%) completed follow-up and were included in the noninferiority analysis. At 1 year, there were 21 deaths (4.6%) in the TAVI group and 30 deaths (6.6%) in the surgery group, with an adjusted absolute risk difference of -2.0% (1-sided 97.5% CI, -∞ to 1.2%; P < .001 for noninferiority). Of 30 prespecified secondary outcomes reported herein, 24 showed no significant difference at 1 year. TAVI was associated with significantly shorter postprocedural hospitalization (median of 3 days [IQR, 2 to 5 days] vs 8 days [IQR, 6 to 13 days] in the surgery group). At 1 year, there were significantly fewer major bleeding events after TAVI compared with surgery (7.2% vs 20.2%, respectively; adjusted hazard ratio [HR], 0.33 [95% CI, 0.24 to 0.45]) but significantly more vascular complications (10.3% vs 2.4%; adjusted HR, 4.42 [95% CI, 2.54 to 7.71]), conduction disturbances requiring pacemaker implantation (14.2% vs 7.3%; adjusted HR, 2.05 [95% CI, 1.43 to 2.94]), and mild (38.3% vs 11.7%) or moderate (2.3% vs 0.6%) aortic regurgitation (adjusted odds ratio for mild, moderate, or severe [no instance of severe reported] aortic regurgitation combined vs none, 4.89 [95% CI, 3.08 to 7.75]). Conclusions and Relevance: Among patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk, TAVI was noninferior to surgery with respect to all-cause mortality at 1 year. Trial Registration: isrctn.com Identifier: ISRCTN57819173.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
2.
J Invasive Cardiol ; 33(10): E761-E768, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34521771

RESUMO

OBJECTIVES: To assess the impact of balloon use for predilation, valve implantation, or postdilation on in-hospital mortality among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR utilizes self-expanding, mechanically expanding, or balloon-expandable valves. Balloon inflation is inherent to deployment of balloon-expandable valves. Balloons may additionally be used with all valve types for pre- and postdilation. The relationships between valve mechanism, balloon use, and in-hospital mortality are not fully characterized. METHODS: Prospective data were collected on 4063 patients undergoing TAVR for aortic stenosis at 4 high-volume centers in the United Kingdom. In-hospital mortality was analyzed according to valve expansion mechanism, use of balloons for pre- and postdilation, and specific cause of death. RESULTS: Mean patient age was 83 ± 8 years. Implanted valves were self expanding (n = 2241; 55%), mechanically expanding (n = 1092; 27%), or balloon expandable (n = 727; 18%). In-hospital death occurred in 66 cases (1.6%). Thirty-six deaths (54.5%) were classified as implantation-related mortalities, with rates of 0.8%, 0.5%, and 1.7% (P=.04) among self-expanding, mechanically expanding, and balloon-expandable technologies, respectively. Patients who underwent balloon inflation at any stage of their procedure (n = 2556; 63%) had significantly higher implantation-related mortality than those who did not (1.3% vs 0.3%, respectively; P<.01). Balloon-expandable valve procedures were associated with significantly higher all-cause mortality (2.6% vs 1.4%; P=.02) and implantation-related mortality (1.7% vs 0.7%; P=.02) than non-balloon-expandable valve procedures. Balloon-related complications accounted for 18 cases (26%) of total in-hospital mortality, including all 12 cases (17.4%) of annular rupture and 5 cases (7.2%) of coronary occlusion. CONCLUSIONS: Balloon use for predilation, valve implantation, or postdilation was associated with an increased mortality risk. Balloon-related complications were the largest contributor to in-hospital mortality, comprising all cases of annular rupture and the majority of coronary occlusion cases.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Mortalidade Hospitalar , Humanos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Thromb Haemost ; 119(7): 1171-1181, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31129911

RESUMO

BACKGROUND: Oral P2Y12 inhibitors take more than 2 hours to achieve full effect in healthy subjects and this action is further delayed in patients with acute myocardial infarction. Intravenous P2Y12 inhibition might lead to more timely and potent anti-platelet effect in the context of emergency primary angioplasty, improving myocardial recovery. OBJECTIVES: This article compares the efficacy of intravenous cangrelor versus ticagrelor in a ST-elevation myocardial infarction (STEMI) population treated with primary percutaneous coronary intervention (PPCI). MATERIALS AND METHODS: In an open-label, prospective, randomized controlled trial, 100 subjects with STEMI were assigned 1:1 to intravenous cangrelor or oral ticagrelor. The co-primary endpoints were platelet P2Y12 inhibition at infarct vessel balloon inflation time, 4 and 24 hours. Secondary endpoints included indices of coronary microcirculatory function: index of microvascular resistance (IMR), initial infarct size (troponin at 24 hours) and final infarct size at 12 weeks (cardiac magnetic resonance). Secondary endpoints included indices of coronary microcirculatory function (index of microvascular resistance [IMR]), initial infarct size (troponin at 24 hours), final infarct size at 12 weeks (cardiac magnetic resonance), corrected thrombolysis in myocardial infarction (TIMI) frame count, TIMI flow grade, myocardial perfusion grade, and ST-segment resolution (ClinicalTrials.gov NCT02733341). RESULTS: P2Y12 inhibition at first balloon inflation time was significantly greater in cangrelor-treated patients (cangrelor P2Y12 reaction unit [PRU] 145.2 ± 50.6 vs. ticagrelor 248.3 ± 55.1). There was no difference in mean PRU at 4 and 24 to 36 hours post-dosing. IMR, final infarct size, angiographic and electrocardiographic measures of reperfusion were all similar between groups. CONCLUSION: Cangrelor produces more potent P2Y12 inhibition at the time of first coronary balloon inflation time compared with ticagrelor. Despite this enhanced P2Y12 inhibition, coronary microvascular function and final infarct size did not differ between groups.


Assuntos
Monofosfato de Adenosina/análogos & derivados , Plaquetas/fisiologia , Vasos Sanguíneos/patologia , Infarto do Miocárdio/tratamento farmacológico , Miocárdio/metabolismo , Ticagrelor/uso terapêutico , Monofosfato de Adenosina/uso terapêutico , Idoso , Plaquetas/efeitos dos fármacos , Vasos Sanguíneos/efeitos dos fármacos , Células Cultivadas , Feminino , Humanos , Masculino , Microcirculação/efeitos dos fármacos , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Infarto do Miocárdio/cirurgia , Miocárdio/patologia , Intervenção Coronária Percutânea , Ativação Plaquetária , Testes de Função Plaquetária , Receptores Purinérgicos P2Y12/metabolismo , Fluxo Sanguíneo Regional/efeitos dos fármacos
4.
Catheter Cardiovasc Interv ; 93(6): 1116-1123, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30773838

RESUMO

AIMS: Patients with bicuspid valves represent a challenging anatomical subgroup for transcatheter aortic valve implantation (TAVI). This analysis evaluated the clinical outcomes of the fully repositionable and retrievable Lotus Valve System in patients with bicuspid aortic valves enrolled in the RESPOND post-market registry. METHODS AND RESULTS: The prospective, open-label RESPOND study enrolled 1,014 patients at 41 centers in Europe, New Zealand, and Latin America, 31 (3.1%) of whom had bicuspid aortic valves. The mean age in the bicuspid patient cohort was 76.4 years, 64.5% were male, and the baseline STS score was 6.0 ± 10.2. Procedural success was 100%, with no cases of malpositioning, valve migration, embolization, or valve-in-valve. Repositioning was attempted in 10 cases (32.3%). There was one death (3.2%) and one stroke (3.2%) at 30-day follow-up. Mean AV gradient was reduced from 48.7 ± 17.0 mmHg at baseline to 11.8 ± 5.1 mmHg at hospital discharge (P < 0.001); mean effective orifice area (EOA) was increased from 0.6 ± 0.2 cm2 to 1.7 ± 0.4 cm2 (P < 0.001). There were no cases of moderate or severe paravalvular leak (PVL) adjudicated by the core laboratory; four subjects (13.8%) had mild PVL, 5 (17.2%) had trace PVL. The rate of pacemaker (PM) implantation for PM-naïve patients was 22.2% (6/27). CONCLUSIONS: Data from the RESPOND registry demonstrate good clinical and echocardiographic outcomes up to 1 year postimplantation in patients with bicuspid aortic valves using the repositionable Lotus Valve.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/complicações , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Europa (Continente) , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , América Latina , Masculino , Nova Zelândia , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
5.
Heart ; 104(24): 2058-2066, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30030336

RESUMO

OBJECTIVES: To investigate the association of the CharlsonComorbidity Index (CCI) with clinical outcomes after transcatheter aortic valve implantation (TAVI). BACKGROUND: Patients undergoing TAVI have high comorbid burden; however, there is limited evidence of its impact on clinical outcomes. METHODS: Data from 1887 patients from the UK, Canada, Spain, Switzerland and Italy were collected between 2007 and 2016. The association of CCI with 30-day mortality, Valve Academic Research Consortium-2 (VARC-2) composite early safety, long-term survival and length of stay (LoS) was calculated using logistic regression and Cox proportional hazard models, as a whole cohort and at a country level, through a two-stage individual participant data (IPD) random effect meta-analysis. RESULTS: Most (60%) of patients had a CCI ≥3. A weak correlation was found between the total CCI and four different preoperative risks scores (ρ=0.16 to 0.29), and approximately 50% of patients classed as low risk from four risk prediction models still presented with a CCI ≥3. Per-unit increases in total CCI were not associated with increased odds of 30-day mortality (OR 1.09, 95% CI 0.96 to 1.24) or VARC-2 early safety (OR 1.04, 95% CI 0.96 to 1.14) but were associated with increased hazard of long-term mortality (HR 1.10, 95% CI 1.05 to 1.16). The two-stage IPD meta-analysis indicated that CCI was not associated with LoS (HR 0.97, 95% CI 0.93 to 1.02). CONCLUSION: In this multicentre international study, patients undergoing TAVI had significant comorbid burden. We found a weak correlation between the CCI and well-established preoperative risks scores. The CCI had a moderate association with long-term mortality up to 5 years post-TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter , Adulto , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/epidemiologia , Canadá/epidemiologia , Comorbidade/tendências , Feminino , Seguimentos , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Espanha/epidemiologia , Suíça/epidemiologia , Fatores de Tempo , Adulto Jovem
6.
J Am Heart Assoc ; 6(6)2017 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-28655733

RESUMO

BACKGROUND: Recent recommendations suggest that in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation and coexistent significant coronary artery disease, the latter should be treated before the index procedure; however, the evidence basis for such an approach remains limited. We performed a systematic review and meta-analysis to study the clinical outcomes of patients with coronary artery disease who did or did not undergo revascularization prior to transcatheter aortic valve implantation. METHODS AND RESULTS: We conducted a search of Medline and Embase to identify studies evaluating patients who underwent transcatheter aortic valve implantation with or without percutaneous coronary intervention. Random-effects meta-analyses with the inverse variance method were used to estimate the rate and risk of adverse outcomes. Nine studies involving 3858 participants were included in the meta-analysis. Patients who underwent revascularization with percutaneous coronary intervention had a higher rate of major vascular complications (odd ratio [OR]: 1.86; 95% confidence interval [CI], 1.33-2.60; P=0.0003) and higher 30-day mortality (OR: 1.42; 95% CI, 1.08-1.87; P=0.01). There were no differences in effect estimates for 30-day cardiovascular mortality (OR: 1.03; 95% CI, 0.35-2.99), myocardial infarction (OR: 0.86; 95% CI, 0.14-5.28), acute kidney injury (OR: 0.89; 95% CI, 0.42-1.88), stroke (OR: 1.07; 95% CI, 0.38-2.97), or 1-year mortality (OR: 1.05; 95% CI, 0.71-1.56). The timing of percutaneous coronary intervention (same setting versus a priori) did not negatively influence outcomes. CONCLUSIONS: Our analysis suggests that revascularization before transcatheter aortic valve implantation confers no clinical advantage with respect to several patient-important clinical outcomes and may be associated with an increased risk of major vascular complications and 30-day mortality. In the absence of definitive evidence, careful evaluation of patients on an individual basis is of paramount importance to identify patients who might benefit from elective revascularization.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Estenose Coronária/complicações , Estenose Coronária/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Seleção de Pacientes , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Complicações Pós-Operatórias/etiologia , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
7.
JACC Cardiovasc Interv ; 10(3): 276-282, 2017 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-28183467

RESUMO

OBJECTIVES: The authors present the UK and Irish real-world learning curve experience of the Evolut R transcatheter heart valve. BACKGROUND: The Evolut R is a self-expanding, repositionable, and fully recapturable second-generation transcatheter heart valve with several novel design features to improve outcomes and reduce complications. METHODS: Clinical, procedural, and 30-day outcome data were prospectively collected for the first 264 patients to receive the Evolut R valve in the United Kingdom and Ireland. RESULTS: A total of 264 consecutive Evolut R implantations were performed across 9 centers. The mean age was 81.1 ± 7.8 years, and the mean logistic European System for Cardiac Operative Risk Evaluation score was 19.9 ± 13.7%. Procedural indications included aortic stenosis (72.0%), mixed aortic valve disease (17.4%), and failing aortic valve bioprostheses (10.6%). Conscious sedation was used in 39.8% of patients and transfemoral access in 93.6%. The procedural success rate was 91.3%, and paravalvular leak immediately after implantation was mild or less in 92.3%. Major complications were rare: cardiac tamponade in 0.4%, conversion to sternotomy in 0.8%, annular rupture in 0.0%, coronary occlusion in 0.8%, major vascular in 5.3%, acute kidney injury in 6.1%, new permanent pacemaker implantation in 14.7%, and procedure-related death in 0.0%. At 30-day follow-up, survival was 97.7%, paravalvular leak was mild or less in 92.3%, and the stroke rate was 3.8%. CONCLUSIONS: This registry represents the largest published real-world experience of the Evolut R valve. The procedural success rate was high and safety was excellent, comparable with previous studies of the Evolut R valve and other second-generation devices. The low rate of complications represents an improvement on first-generation devices.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Competência Clínica , Feminino , Humanos , Irlanda , Curva de Aprendizado , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...