Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 12644, 2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-37542129

RESUMO

The aim of this study was to evaluate the association between types of ventilator and the one-year survival rate of patients with acute respiratory distress syndrome (ARDS) due to SARS­CoV-2 infection. This multi-center, retrospective observational study was conducted on 1078 adult patients admitted to five university-affiliated hospitals in Iran who underwent mechanical ventilator (MV) due to ARDS. Of the 1078 patients, 781 (72.4%) were managed with ICU ventilators and 297 (27.6%) with transport ventilators. Overall mortality was significantly higher in patients supported with transport ventilator compared to patients supported with ICU ventilator (16.5% vs. 9.3% P = 0.001). Regression analysis revealed that the expected hazard overall increased with age (HR: 1.525, 95% CI 1.112-1.938, P = 0.001), opacity score (HR: 1.448, 95% CI 1.122-2.074, P = 0.001) and transport ventilator versus ICU ventilator (HR: 1.511, 95% CI 1.143-2.187, P = 0.029). The Kaplan-Meier curves of survival analysis showed that patients supported with ICU ventilator had a significantly higher 1-year survival rate (P = 0.001). In MV patients with ARDS due to COVID-19, management with non-ICU sophisticated ventilators was associated with a higher mortality rate compared to standard ICU ventilators. However, more studies are needed to determine the exact effect of ventilator types on the outcome of critically ill patients.


Assuntos
COVID-19 , Síndrome do Desconforto Respiratório , Adulto , Humanos , SARS-CoV-2 , COVID-19/terapia , Taxa de Sobrevida , Unidades de Terapia Intensiva , Síndrome do Desconforto Respiratório/terapia , Ventiladores Mecânicos , Respiração Artificial
2.
J Neurol Sci ; 446: 120563, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36701890

RESUMO

Blood-based biomarkers were recently proposed as predictors of traumatic brain injury (TBI) outcomes. This would be a critical step forward since the majority of TBI events are mild and structural brain damage in this group may be missed by current brain imaging methods. We sought to determine the performance of early measurement of interleukin-10 (IL-10) to distinguish computed tomography (CT)-positive from negative patients with mild TBI. We designed a single-center prospective observational study, which enrolled consecutive patients classed with mild TBI according to Glasgow Coma Scale [GCS] scores and appearance of at least one clinical symptom. Serum IL-10 levels were measured <3 h post hospital admission. The performance of IL-10 levels in correctly classifying patients was evaluated. IL-10 levels were significantly higher in the group with positive CT scans (p < 0.001). With sensitivity set at 100%, the specificity of IL-10 was only 38.1%. However, the specificities of IL-10 for prediction of negative and positive cases increased to 59% and 49%, respectively, when both parameters were assessed within 90 min of admission. For mild TBI patients between 36 and 66 years, classification performance increased significantly at the 100% sensitivity level with a specificity of 93%. Our results suggest that IL-10 may be an easily accessible clinically useful diagnostic biomarker that can distinguish between mild TBI patients with and without structural brain damage with higher effectiveness when lower times of blood sampling are employed and patients are between 36 and 66 years of age.


Assuntos
Concussão Encefálica , Lesões Encefálicas Traumáticas , Lesões Encefálicas , Humanos , Interleucina-10 , Biomarcadores , Encéfalo , Escala de Coma de Glasgow , Tomografia Computadorizada por Raios X
3.
Front Psychiatry ; 12: 791342, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34925113

RESUMO

Using physical devices such as eye masks and earplugs to improve to the quality of sleep in intensive care units (ICUs) is a very important issue. This study was conducted to assess the efficacy of eye masks and earplugs for sleep promotion in critically ill adult patients in the ICU based on various sleep quality assessment tools. PubMed, Scopus, Web of Science, and ProQuest were systematically retrieved until May 2021. Both randomized and non-randomized experimental and quasi-experimental studies were included if they evaluated the efficacy of eye masks and earplugs interventions on sleep outcomes in critically ill patients. The methodological quality was assessed by the Joanna Briggs Institute (JBI) critical appraisal tool. For the main outcome (sleep quality), a mean difference (MD) and confidence intervals (CIs) of 95% were determined. A total of 2,687 participants from 35 studies met the inclusion criteria. Twenty one studies were included in meta-analysis and 14 studies were included in the qualitative analysis. According to the results based on sleep quality assessment tools; overall scores of Pittsburgh Sleep Quality Index (PSQI) and Richards-Campbell Sleep Questionnaire (RCSQ), eye mask and/or earplug interventions have a positive effect on sleep quality. Based on Verran-Snyder-Halpern Sleep Scale (VSHSS), sleep disturbance was significantly lower in the intervention groups. In terms of polysomnography, the use of eye masks and/or earplugs resulted in a significant increase in total sleep time, sleep efficiency, rapid eye movement (REM) time, significant reduction of awaking, and sleep arousals index. The results of the present study suggest that the use of earplugs or eye masks, separately or combined affects sleep improvement in critically ill patients. Systematic Review Registration: https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=145830, PROSPERO: CRD42020145830.

4.
Biomed Res Int ; 2021: 5550653, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34447851

RESUMO

INTRODUCTION: The gastric residual volume (GRV) monitoring in patients with mechanical ventilation (MV) is a common and important challenge. The purpose of this study was to compare the effect of neostigmine and metoclopramide on GRV among MV patients in the intensive care unit (ICU). METHODS: In a double-blind randomized clinical trial, a total of 200 mechanically ventilated ICU patients with GRV > 120 ml (6 hours after the last gavage) were randomly assigned into two groups (A and B) with 100 patients in each group. Patients in groups A and B received intravenous infusion of neostigmine at a dose of 2.5 mg/100 ml normal saline and metoclopramide at a dose of 10 mg/100 ml normal saline, within 30 minutes, respectively. GRV was evaluated 5 times for each patient, once before the intervention and 4 times (at 3, 6, 9, and 12 hours) after the intervention. In addition, demographic characteristics including age and gender, as well as severity illness based on the sequential organ failure assessment score (SOFA), were initially recorded for all patients. RESULTS: After adjusting of demographic and clinical characteristics (age, gender, and SOFA score), the generalized estimating equation (GEE) model revealed that neostigmine treatment increased odds of GRV improvement compared to the metoclopramide group (OR = 2.45, 95% CI: 1.60-3.76, P < 0.001). However, there is a statistically significant time trend (within-subject differences or time effect) regardless of treatment groups (P < 0.001). CONCLUSION: According to the results, although neostigmine treatment significantly improved GRV in more patients in less time, within 12 hours of treatment, all patients in both groups had complete recovery. Considering that there was no significant difference between the two groups in terms of side effects, it seems that both drugs are effective in improving the GRV of ICU patients.


Assuntos
Esvaziamento Gástrico/efeitos dos fármacos , Metoclopramida/uso terapêutico , Neostigmina/uso terapêutico , Respiração Artificial/métodos , Antieméticos/uso terapêutico , Estado Terminal/terapia , Método Duplo-Cego , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Parassimpatomiméticos/uso terapêutico , Respiração Artificial/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...