Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Biosensors (Basel) ; 13(11)2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37998132

RESUMO

Recycling and revalorization of waste are currently essential for sustainable growth. Mill scale, a waste product from steel production industries, which contains high levels of iron and minimal impurities, is proposed in this study as the source to synthesize magnetite nanoparticles (Fe3O4) for an enhancement of a lactate biosensor range. The synthesized Fe3O4 nanoparticles were coated with polydopamine (PDA) to prevent aggregation and degradation, creating a stable platform for immobilizing lactate oxidase enzyme (LOx) on their surfaces. The characterization of the Fe3O4@PDA material was carried out using transmission electron microscopy (TEM), dynamic light scattering (DLS), and measurement of the polydispersity index (PdI). The Fe3O4@PDA-LOx material was then deposited on a screen-printed carbon electrode modified with Prussian blue (SPCE-PB) for lactate detection. The biosensor exhibited a broad, dual linear concentration-response range, one from 0.1 to 4.62 mM with a limit of detection of 0.32 mM and sensitivity of 1.54 µAmM-1cm-2, and another one from 4.62 to 149.21 mM with a limit of detection of 6.31 mM and sensitivity of 0.08 µAmM-1cm-2. The dual-range concentration response of the biosensor makes it an ideal tool for lactate determination in various applications, including sports medicine, clinical diagnosis, and industrial bioprocessing.


Assuntos
Técnicas Biossensoriais , Nanopartículas de Magnetita , Nanopartículas de Magnetita/química , Oxigenases de Função Mista , Ácido Láctico , Eletrodos
2.
Membranes (Basel) ; 12(11)2022 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-36363629

RESUMO

Microfluidic paper-based analytical devices (µPADs) are leading the field of low-cost, quantitative in-situ assays. However, understanding the flow behavior in cellulose-based membranes to achieve an accurate and rapid response has remained a challenge. Previous studies focused on commercial filter papers, and one of their problems was the time required to perform the test. This work studies the effect of different cellulose substrates on diffusion-based sensor performance. A diffusion-based sensor was laser cut on different cellulose fibers (Whatman and lab-made Sisal papers) with different structure characteristics, such as basis weight, density, pore size, fiber diameter, and length. Better sensitivity and faster response are found in papers with bigger pore sizes and lower basis weights. The designed sensor has been successfully used to quantify the ionic concentration of commercial wines with a 13.6 mM limit of detection in 30 s. The developed µPAD can be used in quantitative assays for agri-food applications without the need for any external equipment or trained personnel.

3.
Am J Physiol Cell Physiol ; 323(5): C1496-C1511, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36036447

RESUMO

Adenosine deaminases acting on RNAs convert adenosines (A) to inosines (I) in structured or double-stranded RNAs. In mammals, this process is widespread. In the human transcriptome, more than a million different sites have been identified that undergo an ADAR-mediated A-to-I exchange Inosines have an altered base pairing potential due to the missing amino group when compared to the original adenosine. Consequently, inosines prefer to base pair with cytosines but can also base pair with uracil or adenine. This altered base pairing potential not only affects protein decoding at the ribosome but also influences the folding of RNAs and the proteins that can associate with it. Consequently, an A to I exchange can also affect RNA processing and turnover (Nishikura K. Annu Rev Biochem 79: 321-349, 2010; Brümmer A, Yang Y, Chan TW, Xiao X. Nat Commun 8: 1255, 2017). All of these events will interfere with gene expression and therefore, can also affect cellular and organismic physiology. As double-stranded RNAs are a hallmark of viral pathogens RNA-editing not only affects RNA-processing, coding, and gene expression but also controls the antiviral response to double-stranded RNAs. Most interestingly, recent advances in our understanding of ADAR enzymes reveal multiple layers of regulation by which ADARs can control antiviral programs. In this review, we focus on the recoding of mRNAs where the altered translation products lead to physiological changes. We also address recent advances in our understanding of the multiple layers of antiviral responses and innate immune modulations mediated by ADAR1.


Assuntos
Edição de RNA , Proteínas de Ligação a RNA , Animais , Humanos , Edição de RNA/genética , Proteínas de Ligação a RNA/genética , Proteínas de Ligação a RNA/metabolismo , Inosina/genética , Inosina/metabolismo , RNA de Cadeia Dupla , Adenosina/genética , Adenosina/metabolismo , RNA Viral , Mamíferos/genética , Mamíferos/metabolismo , Antivirais
4.
RNA Biol ; 18(sup1): 41-50, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34569891

RESUMO

RNA editing by cytosine and adenosine deaminases changes the identity of the edited bases. While cytosines are converted to uracils, adenines are converted to inosines. If coding regions of mRNAs are affected, the coding potential of the RNA can be changed, depending on the codon affected. The recoding potential of nucleotide deaminases has recently gained attention for their ability to correct genetic mutations by either reverting the mutation itself or by manipulating processing steps such as RNA splicing. In contrast to CRISPR-based DNA-editing approaches, RNA editing events are transient in nature, therefore reducing the risk of long-lasting inadvertent side-effects. Moreover, some RNA-based therapeutics are already FDA approved and their use in targeting multiple cells or organs to restore genetic function has already been shown. In this review, we provide an overview on the current status and technical differences of site-directed RNA-editing approaches. We also discuss advantages and challenges of individual approaches.


Assuntos
Sistemas CRISPR-Cas , Engenharia Genética/métodos , Mutação , Edição de RNA , Animais , Humanos
5.
Sensors (Basel) ; 21(10)2021 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-34064828

RESUMO

Microfluidic paper-based analytical devices (µPADs) are a promising technology to enable accurate and quantitative in situ assays. Paper's inherent hydrophilicity drives the fluids without the need for external pressure sources. However, controlling the flow in the porous medium has remained a challenge. This study addresses this problem from the nature of the paper substrate and its design. A computational fluid dynamic model has been developed, which couples the characteristics of the porous media (fiber length, fiber diameter and porosity) to the fluidic performance of the diffusion-based µPAD sensor. The numerical results showed that for a given porous membrane, the diffusion, and therefore the sensor performance is affected not only by the substrate nature but also by the inlets' orientation. Given a porous substrate, the optimum performance is achieved by the lowest inlets' angle. A diffusion-based self-referencing colorimetric sensor was built and validated according to the design. The device is able to quantify the hydronium concentration in wines by comparison to 0.1-1.0 M tartaric acid solutions with a 41.3 mM limit of detection. This research showed that by proper adjustments even the simplest µPADs can be used in quantitative assays for agri-food applications.

6.
J Bronchology Interv Pulmonol ; 28(4): 248-254, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34085805

RESUMO

BACKGROUND: There is a paucity of real-time imaging modalities available for the bronchoscopic biopsy of peripheral lung nodules. We aim to demonstrate the feasibility of the O-arm imaging system to guide real-time biopsies of peripheral lung nodules during electromagnetic navigation bronchoscopy. METHODS: A retrospective review was performed at 2 academic medical centers utilizing O-arm guidance. RESULTS: The average nodule size was 2.1×2.0 cm and were mostly solid (66%) with a positive bronchus sign (83%). O-arm imaging confirmed tool-in-lesion in all cases. The diagnostic yield was 33%. Four cases were nondiagnostic of the 6 cases performed. In these cases, necrotic tissue was the most common (75%) and showed resolution following subsequent imaging. The average 3-dimensional (3D) spin time was 23.5 seconds. The average number of 3D spins performed per case was 4.33. The average effective dose per 3D spin was 3.73 mSv. CONCLUSION: We have demonstrated the O-arm's feasibility with electromagnetic navigation bronchoscopy for peripheral lung nodules. The O-arm was able to confirm tool-in-lesion in all cases which added confidence to the biopsy. Four high-resolution 3D spins per case may limit the total computed tomography effective dose. We also noted that both metal and radiation scatter were minimal when appropriate radiation safety standards were met. Although additional experience and data will be required to verify the O-arm approach for routine use, our initial experience is promising.


Assuntos
Neoplasias Pulmonares , Cirurgia Assistida por Computador , Biópsia , Brônquios , Broncoscopia , Fenômenos Eletromagnéticos , Estudos de Viabilidade , Humanos , Imageamento Tridimensional , Neoplasias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
7.
J Med Phys ; 38(2): 74-81, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23776310

RESUMO

Dose calculation algorithm is one of the main sources of uncertainty in the radiotherapy sequences. The aim of this study was to compare the accuracy of different inhomogeneity correction algorithms for external photon beam dose calculations. The methodology was based on International Atomic Energy Agency TEC-DOC 1583. The phantom was scanned in every center, using computed tomography and seven tests were planned on three-dimensional treatment planning systems (TPSs). The doses were measured with ion chambers and the deviation between measured and TPS calculated dose was reported. This methodology was tested in five different hospitals which were using six different algorithms/inhomogeneity correction methods implemented in different TPSs. The algorithms in this study were divided into two groups: Measurement-based algorithms (type (a)) and model-based algorithms (type (b)). In type (a) algorithms, we saw 7.6% and 11.3% deviations out of agreement criteria for low- and high-energy photons, respectively. While in type (b) algorithms, these values were 4.3% and 5.1%, respectively. As a general trend, the numbers of measurements with results outside the agreement criteria increase with the beam energy and decrease with advancement of TPS algorithms. More advanced algorithm would be preferable and therefore should be implanted in clinical practice, especially for calculation in inhomogeneous medias like lung and bone and for high-energy beams calculation at low depth points.

8.
Eur Radiol ; 23(3): 623-31, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22940731

RESUMO

OBJECTIVE: To survey procedures and protocols in paediatric computed tomography (CT) in 40 less resourced countries. METHODS: Under a project of the International Atomic Energy Agency, 146 CT facilities in 40 countries of Africa, Asia, Europe and Latin America responded to an electronic survey of CT technology, exposure parameters, CT protocols and doses. RESULTS: Modern MDCT systems are available in 77 % of the facilities surveyed with dedicated paediatric CT protocols available in 94 %. However, protocols for some age groups were unavailable in around 50 % of the facilities surveyed. Indication-based protocols were used in 57 % of facilities. Estimates of radiation dose using CTDI or DLP from standard CT protocols demonstrated wide variation up to a factor of 100. CTDI(vol) values for the head and chest were between two and five times those for an adult at some sites. Sedation and use of shielding were frequently reported; immobilisation was not. Records of exposure factors were kept at 49 % of sites. CONCLUSION: There is significant potential for improvement in CT practice and protocol use for children in less resourced countries. Dose estimates for young children varied widely. This survey provides critical baseline data for ongoing quality improvement efforts by the IAEA.


Assuntos
Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Pediatria/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Proteção Radiológica/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , África/epidemiologia , Ásia/epidemiologia , Europa (Continente)/epidemiologia , Pesquisas sobre Atenção à Saúde , Humanos , América Latina/epidemiologia , Doses de Radiação
9.
Eur J Radiol ; 81(10): e982-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22835877

RESUMO

Recognizing the lack of information on image quality and patient doses in most countries in Asia, the International Atomic Energy Agency (IAEA) initiated a project to assess the status of imaging technology, practice in conventional radiography, mammography, computed tomography (CT) and interventional procedures, and to implement optimisation actions. A total of 20 countries participated. Obsolete practices of use of fluoroscopy for positioning, photofluorography, chest fluoroscopy and conventional tomography were reported by 4 out of 7 countries that provided this information. Low-kV technique for chest radiography is in use in participating countries for 20-85% of cases, and manual processing is in 5-85% of facilities in 5 countries. Instances of the use of adult CT protocol for children in three participating countries were observed in 10-40% of hospitals surveyed. After implementation of a Quality Control programme, the image quality in conventional radiography improved by zero to 13 percentage points in certain countries and dose reduction was from 10% to 85%. In mammography, poor quality, ranging from 10 to 29% of images in different countries was observed. The project increased attention to dose quantities and dose levels in computed tomography, although doses in most cases were not higher than reference levels. In this study 16-19% of patients in interventional cardiology received doses that have potential for either stochastic risk or tissue reaction. This multi-national study is the first of its kind in the Asia, and it provided insight into the situation and opportunities for improvement.


Assuntos
Carga Corporal (Radioterapia) , Diagnóstico por Imagem/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Lesões por Radiação/epidemiologia , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/estatística & dados numéricos , Proteção Radiológica/estatística & dados numéricos , Adulto , Ásia/epidemiologia , Criança , Coleta de Dados , Humanos , Vigilância da População
10.
Radiat Prot Dosimetry ; 152(4): 438-43, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22570508

RESUMO

The general population, everywhere in the world is exposed to a small dose of ionising radiation from natural sources. Stochastic effects such as cancer and genetic disorders are caused when living creatures are exposed to low doses. In Iran, it is measured in some cities, especially in high-background areas such as Ramsar, but so far there is no measurement in the Hamadan province. Hamadan is located in the west of Iran. Measurements were performed using a RDS-110 survey meter, CaSO(4):Dy thermoluminecense dosimetries (TLDs) and a Harshaw 4000 TLD reader. To estimate the dose rate  outdoors, four stations along the main directions (north, south, west and east) and one in the town centre were selected. Mean annual X and gamma equivalent dose in Hamadan province are 1.12±0.22  and 1.66±0.07 mSv, which related to RDS-110 survey meter and TLDs measurements, respectively. The TLDs and RDS-110 results are representative of the external photon radiation doses for the selected monitoring locations and for those locations for the hours during which the measurements were taken, respectively. Maximum and minimum of external photon radiation doses are related to Hamadan and Kaboudar-Ahang towns, respectively. According to the results of the study, it seems that the annual X and gamma equivalent dose in Hamadan province exceeded the global mean external exposure amounts by the UNSCEAR, and further studies are needed to measure internal exposures to determine the total environmental radiation level in  Hamadan province.


Assuntos
Radiação de Fundo , Raios gama , Monitoramento de Radiação/métodos , Irã (Geográfico) , Doses de Radiação
11.
AJR Am J Roentgenol ; 198(5): 1021-31, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22528891

RESUMO

OBJECTIVE: The purpose of this study was to assess the frequency of pediatric CT in 40 less-resourced countries and to determine the level of appropriateness in CT use. MATERIALS AND METHODS: Data on the increase in the number of CT examinations during 2007 and 2009 and appropriate use of CT examinations were collected, using standard forms, from 146 CT facilities at 126 hospitals. RESULTS: The lowest frequency of pediatric CT examinations in 2009 was in European facilities (4.3%), and frequencies in Asia (12.2%) and Africa (7.8%) were twice as high. Head CT is the most common CT examination in children, amounting to nearly 75% of all pediatric CT examinations. Although regulations in many countries assign radiologists with the main responsibility of deciding whether a radiologic examination should be performed, in fact, radiologists alone were responsible for only 6.3% of situations. Written referral guidelines for imaging were not available in almost one half of the CT facilities. Appropriateness criteria for CT examinations in children did not always follow guidelines set by agencies, in particular, for patients with accidental head trauma, infants with congenital torticollis, children with possible ventriculoperitoneal shunt malfunction, and young children (< 5 years old) with acute sinusitis. In about one third of situations, nonavailability of previous images and records on previously received patient doses have the potential to lead to unnecessary examinations and radiation doses. CONCLUSION: With increasing use of CT in children and a lack of use of appropriateness criteria, there is a strong need to implement guidelines to avoid unnecessary radiation doses to children.


Assuntos
Padrões de Prática Médica/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , África , Ásia , Criança , Pré-Escolar , Europa (Continente) , Humanos , Lactente , Recém-Nascido , Agências Internacionais , América Latina , Doses de Radiação , Proteção Radiológica , Inquéritos e Questionários
12.
Jpn J Radiol ; 30(2): 162-6, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22180187

RESUMO

PURPOSE: Different types of concretes are used for bunker construction for radiation therapy. As neutron production occurs in high-energy photon beams, the purpose of this study was to investigate the effect of different concretes on photoneutron doses at an isocenter and maze entrance door. MATERIALS AND METHODS: The 18-MV photon beam of a Varian 2100 C/D linear accelerator and a radiation therapy bunker were simulated using the MCNPX Monte Carlo code. Different commercially available concretes were used in photoneutron calculations for the simulated bunker. RESULTS: Higher neutron doses of the water phantom were seen for barytes and galena concretes, while there was no significant (less than 1%) difference between the neutron dose of the phantom for all other concretes. Also, the neutron fluence at the inner and outer maze entrance varied up to 36% depending on the concretes' atomic compositions. CONCLUSION: It can be concluded that application of high-density concretes in order to use limited space or for other purposes may cause higher neutron doses in the maze entrance door and consequently may impose stricter requirements for neutron shielding of maze entrance doors.


Assuntos
Materiais de Construção , Instalações de Saúde , Nêutrons , Aceleradores de Partículas , Fótons , Radioterapia de Alta Energia , Simulação por Computador , Método de Monte Carlo , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA