Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Spine Surg ; 10(2): 295-304, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38974485

RESUMO

Background and Objective: The concept of endoscopic surgery began in the 1930s and has since undergone numerous advancements in both technology and surgical indications. Its main benefit is providing the opportunity to perform surgery while minimizing disruption to surrounding structures. The purpose of this review is to summarize the history, uses, and future directions for spine endoscopic surgery. Methods: A review of national databases was performing using key terms "endoscopic", "spine" and "surgery" for literature from 1900 to 2023. Studies that aimed to describe the utilities of endoscopic surgeries, associated outcomes, limitations, and future directions were included. Studies that were not in English were excluded. Key Content and Findings: This review includes a brief overview of the history of endoscopic surgery and its current two main approaches, transforaminal and interlaminar approaches. It then summarizes the main indications and utilization of endoscopic surgery in the lumbar, cervical and thoracic spine, as well as expansion in managing spine tumors, infections, and outpatient surgical cases. Conclusions: There are many rising indications and uses for endoscopic spine surgery in nearly every aspect of the spine. Compared to conventional spine surgery, there is early evidence showing endoscopic surgery is associated with less post-operative pain, shorter hospital stays, and possibly quicker recovery times. As current trends in spine surgery move towards minimally invasive techniques, it is anticipated that the use of endoscopic surgery will continue to expand.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38887023

RESUMO

STUDY DESIGN: Retrospective study. OBJECTIVE: Evaluate differences in the minimal clinically important difference (MCID) threshold value based on various acceptable statistical methods, and how these differences may influence the interpretation of surgical benefit following elective 1 and 2 level lumbar fusion. SUMMARY OF BACKGROUND DATA: The MCID is a statistically determined threshold value to evaluate if a patient has received benefit from a medical procedure. In the era of value based medicine, the MCID has become increasingly important. However, there is substantial ambiguity surrounding the interpretation of this value given that it can be influenced by both demographic and methodological factors. METHODS: 371 patients that underwent one or two level elective lumbar fusion between June 2021 and June 2023 were included in this study. All patients completed both their preoperative and 6 month post-operative Oswestry Disability Index (ODI), as well as two anchor questions concerning satisfaction with their surgical procedure. The MCID values were calculated using 16 accepted statistical methods, and the resulting MCID values were applied to the cohort to determine how many patients reached MCID by 6 months post fusion. RESULTS: Results demonstrated significant variability in the MCID value. The average MCID value for all 16 methods was 10.5±7.0 points range (0.8 to 25). Distribution methods provided lower threshold MCID values but had greater variability while the Anchor methods resulted in higher threshold values but had lower variability. Depending on the method used 30 to 83% of the cohort reached MCID by 6 months. CONCLUSION: The statistical method used to calculate the MCID resulted in significantly different threshold values, and greatly affected the number of patients meeting MCID. The results demonstrates the complexity surrounding the interpretation of MCID values, and calls into question the utility of a single statistically determined value to assess surgical success.

3.
BMC Musculoskelet Disord ; 24(1): 171, 2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36882825

RESUMO

BACKGROUND: Elliptical shape humeral head prostheses have been recently proposed to reflect a more anatomic shoulder replacement. However, its effect on obligate glenohumeral translation during axial rotation compared to a standard spherical head is still not well understood. The purpose of the study was to compare obligate humeral translation during axial rotation using spherical and elliptical shaped humeral head prostheses. It was hypothesized that the spherical head design would show significantly more obligate translation when compared to the elliptical design. METHODS: Six fresh-frozen cadaveric shoulders were utilized for biomechanical testing of internal (IR) and external (ER) rotation at various levels of abduction (0°, 30°, 45°, 60°) with lines of pull along each of the rotator cuff muscles. Each specimen underwent the following three conditions: (1) native; total shoulder arthroplasty (TSA) using (2) an elliptical and (3) spherical humeral head implant. Obligate translation during IR and ER was quantified using a 3-dimensional digitizer. The radius of curvature of the superoinferior and anteroposterior dimensions of the implants was calculated across each condition. RESULTS: Posterior and inferior translation as well as compound motion of spherical and elliptical heads during ER was similar at all abduction angles (P > 0.05, respectively). Compared to the native humeral head, both implants demonstrated significantly decreased posterior translation at 45° (elliptical: P = 0.003; spherical: P = 0.004) and 60° of abduction (elliptical: P < 0.001; spherical: P < 0.001). During internal rotation at 0° abduction, the spherical head showed significantly more compound motion (P = 0.042) compared to the elliptical head. The spherical implant also demonstrated increased anterior translation and compound motion during internal rotation at 60° abduction (P < 0.001) compared to the resting state. This difference was not significant for the native or elliptical head design at this angle (P > 0.05). CONCLUSION: In the setting of TSA, elliptical and spherical head implants showed similar obligate translation and overall compound motion during axial rotation. A gained understanding of the consequences of implant head shape in TSA may guide future surgical implant choice for better recreation of native shoulder kinematics and potentially improved patient outcomes. LEVEL OF EVIDENCE: Controlled Laboratory Study.


Assuntos
Artroplastia do Ombro , Artroplastia de Substituição , Bursite , Humanos , Rotação , Extremidade Superior , Cabeça do Úmero/cirurgia
4.
Spine J ; 23(7): 945-953, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36963445

RESUMO

BACKGROUND CONTEXT: Low back pain (LBP) is common in children and adolescents, carrying substantial risk for recurrence and continuation into adulthood. Studies have linked obesity to the development of pediatric LBP; however, its association with lumbar spine degeneration, alignment parameters, and opioid use remains debated. PURPOSE: Considering the increasing prevalence of pediatric obesity and LBP and the inherent issues with opioid use, this study aimed to assess the association of obesity with lumbar spine degeneration, spinopelvic alignment, and opioid therapy among pediatric patients. STUDY DESIGN/SETTING: A retrospective study of pediatric patients presenting to a single institute with LBP and no history of spine deformity, tumor, or infection was performed. PATIENT SAMPLE: A totasl of 194 patients (mean age: 16.7±2.3 years, 45.3% male) were included, of which 30 (15.5%) were obese. OUTCOME MEASURES: Prevalence of imaging phenotypes and opioid use among obese to nonobese pediatric LBP patients. Magnetic resonance and plain radiographic imaging were evaluated for degenerative phenotypes (disc bulging, disc herniation, disc degeneration [DD], high-intensity zones [HIZ], disc narrowing, Schmorl's nodes, endplate phenotypes, Modic changes, spondylolisthesis, and osteophytes). Lumbopelvic parameters including lumbar lordosis, pelvic tilt, sacral slope, pelvic incidence and pelvic incidence-lumbar lordosis (PI-LL) mismatch were also examined. METHODS: Demographic and clinical information was recorded, including use of opioids. The associations between obesity and lumbar phenotypes or opiod use were assessed by multiple regression models. RESULTS: Based on multivariate analysis, obesity was significantly associated with the presence of HIZ (adjusted OR: 5.36, 95% CI: 1.30 to 22.09). Further analysis demonstrated obesity (adjusted OR: 3.92, 95% CI: 1.49 to 10.34) and disc herniation (OR: 4.10, 95% CI: 1.50 to 11.26) were associated with opioid use, independent of duration of symptoms, other potential demographic determinants, and spinopelvic alignment. CONCLUSIONS: In pediatric patients, obesity was found to be significantly associated with HIZs of the lumbar spine, while disc herniation and obesity were associated with opioid use. Spinopelvic alignment parameters did not mitigate any outcome. This study underscores that pediatric obesity increases the risk of developing specific degenerative spine changes and pain severity that may necessitate opioid use, emphasizing the importance of maintaining healthy body weight in promoting lumbar spine health in the young.


Assuntos
Degeneração do Disco Intervertebral , Deslocamento do Disco Intervertebral , Lordose , Dor Lombar , Transtornos Relacionados ao Uso de Opioides , Obesidade Infantil , Masculino , Feminino , Humanos , Dor Lombar/diagnóstico por imagem , Dor Lombar/epidemiologia , Dor Lombar/complicações , Deslocamento do Disco Intervertebral/complicações , Obesidade Infantil/complicações , Analgésicos Opioides/efeitos adversos , Lordose/complicações , Estudos Retrospectivos , Degeneração do Disco Intervertebral/epidemiologia , Vértebras Lombares/diagnóstico por imagem
6.
Arch Orthop Trauma Surg ; 143(1): 177-187, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34216260

RESUMO

INTRODUCTION: Elliptical-shaped humeral head prostheses have recently been proposed to reflect a more anatomic shoulder replacement. However, its subsequent effect on micro-motion of the glenoid component is still not understood. MATERIALS AND METHODS: Six fresh-frozen, cadaveric shoulders (mean age: 62.7 ± 9.2 years) were used for the study. Each specimen underwent total shoulder arthroplasty using an anatomic stemless implant. At 15°, 30°, 45° and 60° of glenohumeral abduction, 50° of internal and external rotations in the axial plane were alternatingly applied to the humerus with both an elliptical and spherical humeral head design. Glenohumeral translation was assessed by means of a 3-dimensional digitizer. Micro-motion of the glenoid component was evaluated using four high-resolution differential variable reluctance transducer strain gauges, placed at the anterior, posterior, superior, and inferior aspect of the glenoid component. RESULTS: The elliptical head design showed significantly more micro-motion in total and at the superior aspect of glenoid component during external rotation at 15° (total: P = 0.004; superior: P = 0.004) and 30° (total: P = 0.045; superior: P = 0.033) of abduction when compared to the spherical design. However, during internal rotation, elliptical and spherical heads showed similar amounts of micro-motion at the glenoid component at all tested abduction angles. When looking at glenohumeral translation, elliptical and spherical heads showed similar anteroposterior and superoinferior translation as well as compound motion during external rotation at all tested abduction angles. During internal rotation, the elliptical design resulted in significantly more anteroposterior translation and compound motion at all abduction angles when compared to the spherical design (P < 0.05). CONCLUSION: In the setting of total shoulder arthroplasty, the elliptical head design demonstrated greater glenohumeral translation and micro-motion at the glenoid component during axial rotation when compared to the spherical design, potentially increasing the risk for glenoid loosening in the long term. LEVEL OF EVIDENCE: Controlled Laboratory Study.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Pessoa de Meia-Idade , Idoso , Articulação do Ombro/cirurgia , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Cadáver , Cabeça do Úmero/cirurgia
7.
J Spine Surg ; 9(4): 444-453, 2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-38196727

RESUMO

Background: The role of preoperative patient expectation in spine surgery is not completely understood, but could be essential in predicting patient outcomes. The purpose of this study was to create a standard means to assess patient preoperative expectations and its effect on postoperative satisfaction in the midterm follow-up period. Methods: This is a prospective cohort study design. Forty-five patients undergoing elective cervical or lumbar spine surgery were asked to participate in the study. Using a 10 cm visual analog scale (VAS) score, patients were asked to rate their preoperative pain along with what they expect it to be after surgery. Pre- and postoperative Oswestry Disability Index (ODI) and Neck Disability Index (NDI) were recorded. Overall satisfaction with surgery was recorded along with if they would have surgery again. The patients' preoperative expectations were compared to their postoperative ODI/NDI scores at terminal follow-up around 1 year. Postoperative satisfaction was also correlated as to whether they would have surgery again. Results: Patients who would have surgery again had an average expected decrease in their disability by 37 (±23) compared to 26 (±19) in patients who would not (P=0.201). For patients who would have surgery again, their postoperative pain more closely matched their preoperative expectations. Conclusions: In conclusion, the authors found that patients who were satisfied with their spine surgery improved functionally to a much greater degree from baseline, tended to have higher expectations with regards to level of disability improvement, and had lower expectations with regards to improvement in neck/back pain.

8.
J Spine Surg ; 9(4): 454-462, 2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-38196733

RESUMO

Background: Lumbar spine surgery is an ever-increasing procedure with multiple analgesia techniques utilized for postoperative pain control. More recently, erector spinae plane (ESP) blocks have been used to limit the use of opioids after surgery. The authors aimed to review the current literature on ESP blocks and its potential use in the outpatient setting. Methods: Several randomized controlled trials were evaluated that compared erector spinae block to traditional anesthesia where the primary outcome of postoperative opioid use was assessed. Randomized control trials comparative studies were also evaluated to assess erector spinae block effect on outpatient procedures. Secondary outcomes include, postoperative pain, patient satisfaction, patient length of stay, and post-operative complications. Key Content and Findings: Erector spinae block was found in general to lower postoperative opioid use compared to traditional anesthesia. In addition, the authors found improved patient satisfaction and less postoperative pain in the erector spinae cohort. Post-operative complications were lower in the erector spinae block group compared to traditional anesthesia, especially in regards to vomiting and nausea. Conclusions: While these studies do possess their limitations due to the low number of randomized control studies on erector spinae block, early data does suggest that erector spinae block appears to be superior to that of traditional anesthesia for those undergoing spine surgery.

10.
Int J Spine Surg ; 2022 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-35835573

RESUMO

BACKGROUND: While national databases provide large datasets that can be used to understand trends over time, their correlation with prospectively collected data from local registries has not been established. The purpose of the study was to compare differences in patient demographics and adverse events for patients undergoing elective posterior spinal fusion (PSF) between a national database and institutional registry. METHODS: A retrospective chart review was performed. A total of 14,618 patients (13,678 patients from the National Surgical Quality Improvement Program [NSQIP] database and 940 patients from the institutional registry) who underwent elective 1- to 2-level PSF were included in the study. Preoperative patient demographics and comorbidities of each cohort were compared. In addition, postoperative 30-day complications and readmission were collected. A multivariate analysis was performed to examine for differences in risk factors for 30-day adverse events between the 2 cohorts. RESULTS: A total of 13,678 patients from the NSQIP database and 940 patients from the institutional cohort were included for analysis. Mean age was similar between patient cohorts (60.8 ± 13.1NSQIP vs 58.8 ± 12.9registry), with NSQIP having significantly more patients over the age of 65 (41.4% vs 33.2%, P < 0.001). Overall complication rate was similar between NSQIP (6.8%) and the institutional registry (8.4%). Both found age and female sex to be significant predictors of 30-day adverse events, while obesity, hypertension, and smoking were only found to be predictive in the NSQIP database. CONCLUSIONS: Age and female sex were found to be independent risk factors for 30-day adverse events between both cohorts, while only NSQIP found modifiable comorbidities to be significant predictors. Although large databases allow for trends in quality over time, subtleties in practice variation and data collection methods at the individual institution level need to be considered when generalizing findings, especially as it pertains to modifiable factors. CLINICAL RELEVANCE: Quality metrics and risk factors for patient outcomes are often derived from national databases. This study highlights the differences between study results when outcomes are derived from an institutional registry compared to a national database.

11.
J Clin Med ; 11(11)2022 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35683345

RESUMO

Complex rotator cuff tears provide a significant challenge for treating surgeons, given their high failure rate following repair and the associated morbidity. The purpose of this study is to evaluate the clinical outcomes of patients who underwent biologically enhanced demineralized bone matrix augmentation of rotator cuff repairs. Twenty patients with complex rotator cuff tears underwent arthroscopic rotator cuff repair by a single surgeon with demineralized bone matrix (DBM) augmentation that was biologically enhanced with platelet-rich plasma and concentrated bone marrow aspirate. Post-operative MRI was used to determine surgical success. Patient reported outcome measures and range of motion data were collected pre-operatively and at the final post-operative visit for each patient. Ten patients (50%) with DBM augmentation of their arthroscopic rotator cuff repair were deemed non-failures. The failure group had less improvement of visual analogue pain scale (p = 0.017), Simple Shoulder Test (p = 0.032), Single Assessment Numerical Evaluation (p = 0.006) and abduction (p = 0.046). There was no difference between the groups for change in American Shoulder and Elbow Society score (p = 0.096), Constant-Murley score (p = 0.086), forward elevation (p = 0.191) or external rotation (p = 0.333). The present study found that 50% of patients who underwent biologically enhanced DBM augmentation of their rotator cuff repair demonstrated MRI-determined failure of supraspinatus healing.

12.
J Shoulder Elbow Surg ; 31(11): 2392-2401, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35671930

RESUMO

BACKGROUND: In the setting of irreparable posterosuperior rotator cuff tears (PSRCTs), lower trapezius transfer (LTT) may be anatomically better positioned for restoring the muscular force couple compared with latissimus dorsi transfer (LDT). The purpose of the study was to evaluate the effect of LTT and LDT on glenohumeral kinematics using a dynamic shoulder model. METHODS: Ten fresh-frozen cadaveric shoulders (mean age: 56.5 ± 17.2 years) were tested using a dynamic shoulder simulator. The maximum abduction angle (MAA), superior humeral head migration (SHM), and cumulative deltoid forces (CDFs) were compared across 4 conditions: (1) native; (2) irreparable PSRCT; (3) LTT using an Achilles tendon allograft; and (4) LDT. MAA and SHM were measured using 3-dimensional motion tracking. CDF was recorded in real time throughout the dynamic abduction motion by load cells connected to actuators. RESULTS: Compared to the native state, the PSRCT resulted in a significant decrease (Δ-24.1°; P < .001) in MAA, with a subsequent significant increase after LTT (Δ13.1°; P < .001) and LDT (Δ8.9°; P < .001). LTT achieved a significantly greater MAA than LDT (Δ4.2°; P = .004). Regarding SHM, both LTT (Δ-9.4 mm; P < .001) and LDT (Δ-5.0 mm; P = .008) demonstrated a significant decrease compared with the PSRCT state. LTT also achieved significantly less SHM compared with the LDT (Δ-4.4 mm; P = .011). Further, only the LTT resulted in a significant decrease in CDF compared with the PSRCT state (Δ-21.3 N; P = .048), whereas LTT and LDT showed similar CDF (Δ-11.3 N; P = .346). However, no technique was able to restore the MAA, SHM, and CDF of the native shoulder (P < .001, respectively). CONCLUSION: LTT and LDT both achieved a significant increase in MAA along with significantly less SHM compared with the PSRCT state. Although LTT required significantly less compensatory deltoid forces compared with the PSRCT state, this was not observed for the LDT. Further, the LTT prevented loss of abduction motion and SHM more sufficiently. In the challenging treatment of irreparable PSRCTs, LTT may restore native glenohumeral kinematics more sufficiently, potentially leading to improved postoperative functional outcomes.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Músculos Superficiais do Dorso , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Lesões do Manguito Rotador/cirurgia , Músculos Superficiais do Dorso/cirurgia , Ombro , Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia , Amplitude de Movimento Articular , Fenômenos Biomecânicos , Transferência Tendinosa/métodos , Resultado do Tratamento
13.
Bioengineering (Basel) ; 9(5)2022 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-35621505

RESUMO

While spinal disc pathology has traditionally been treated using fusion-based procedures, recent interest in motion-preserving disc arthroplasties has grown. Traditional spinal fusion is associated with loss of motion, alteration of native spine kinematics, and increased risks of adjacent segment disease. The motion conferred by disc arthroplasty is believed to combat these complications. While the first implant designs resulted in poor patient outcomes, recent advances in implant design and technology have shown promising radiographic and clinical outcomes when compared with traditional fusion. These results have led to a rapid increase in the utilization of disc arthroplasty, with rates of cervical arthroplasty nearly tripling over the course of 7 years. The purpose of this review was to discuss the evolution of implant design, the current implant designs utilized, and their associated outcomes. Although disc arthroplasty shows significant promise in addressing some of the drawbacks associated with fusion, it is not without its own risks. Osteolysis, implant migration, and the development of heterotopic ossification have all been associated with disc arthroplasty. As interest in these procedures grows, so does the interest in developing improved implant designs aimed at decreasing these adverse outcomes. Though they are still relatively new, cervical and lumbar disc arthroplasty are likely to become foundational methodologies for the treatment of disc pathology.

14.
Bioengineering (Basel) ; 9(3)2022 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-35324797

RESUMO

The use of interbody implants for spinal fusion has been steadily increasing to avoid the risks of complications and donor site morbidity when using autologous bone. Understanding the pros and cons of various implant designs can assist the surgeon in choosing the ideal interbody for each individual patient. The goal of these interbody cages is to promote a surface area for bony ingrowth while having the biomechanical properties to support the axial skeleton. Currently, the majority of interbody implants consists of metal or polyether ether ketone (PEEK) cages with bone graft incorporated inside. Titanium alloy implants have been commonly used, however, the large difference in modulus of elasticity from bone has inherent issues. PEEK implants have a desirable surface area with the benefit of a modulus of elasticity closer to that of bone. Unfortunately, clinically, these devices have had increased risk of subsidence. More recently, 3D printed implants have come into the market, providing mechanical stability with increased surface design for bony ingrowth. While clinical outcomes studies are limited, early results have demonstrated more reliable and quicker fusion rates using 3D custom interbody devices. In this review, we discuss the biology of osseointegration, the use of surface coated implants, as well as the potential benefits of using 3D printed interbodies.

15.
JBJS Case Connect ; 12(1)2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-35081063

RESUMO

CASE: We report a 14-year-old girl with adolescent idiopathic scoliosis who experienced bilateral lower extremity paralysis related to postoperative hypotension 10 hours after posterior spinal fusion. She returned to the operating room for spinal cord decompression and hardware removal. Six weeks later, reinstrumentation was performed, and complete neurologic recovery was achieved. CONCLUSION: Delayed presentation of neurologic injury after scoliosis surgery is particularly uncommon. Close postoperative monitoring, with an emphasis on hypotensive etiologies and a low threshold to remove the instrumentation, is essential to rapidly diagnose and treat these catastrophic events.


Assuntos
Cifose , Escoliose , Traumatismos da Medula Espinal , Fusão Vertebral , Adolescente , Feminino , Humanos , Cifose/cirurgia , Paraplegia/etiologia , Paraplegia/cirurgia , Escoliose/complicações , Escoliose/cirurgia , Traumatismos da Medula Espinal/etiologia , Traumatismos da Medula Espinal/cirurgia , Fusão Vertebral/efeitos adversos
16.
Arch Orthop Trauma Surg ; 142(1): 67-76, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32865631

RESUMO

INTRODUCTION: Elliptical shape humeral head prostheses have been proposed to reflect a more anatomic shoulder replacement. Its effect on the rotational range of motion (ROM) compared to a standard spherical head is still not understood. The purpose was to investigate if there would be a difference in rotational ROM when comparing elliptical and spherical prosthetic heads in a dynamic shoulder model. The authors hypothesized that the use of elliptical heads would result in significantly more rotational ROM compared to the spherical head design. MATERIALS AND METHODS: Six fresh-frozen, cadaveric shoulders were evaluated using a dynamic shoulder model. After being tested in the native condition, each specimen underwent 6 conditions in the hemiarthroplasty state: (1) matched-fit spherical head, (2) oversized spherical head, (3) undersized spherical head, (4) matched-fit elliptical head, (5) oversized elliptical head, and (6) undersized elliptical head. Following conversion to total shoulder arthroplasty (TSA), the 6 prior conditions were rerun. Each condition was tested at 0°, 30° and 60° of glenohumeral abduction. Rotational ROM was quantified using 3-dimensional tracking, while dynamically applying alternating forces for internal and external rotation via the rotator cuff tendons. RESULTS: Elliptical and spherical prosthetic heads showed no significant difference in the degree of the total, internal, and external rotational ROM for both the hemiarthroplasty and TSA state. Conversion from hemiarthroplasty to TSA resulted in less degree of total rotational ROM for both head designs in all abduction positions, without reaching statistical significance. There was a significant decrease in total, internal, and external rotational ROM for both elliptical and spherical heads in every replacement condition, when comparing 0° to 30° and 60° of abduction (P < 0.05, respectively). CONCLUSION: In a dynamic shoulder model, elliptical and spherical prosthetic head designs showed no significant difference in the degree of the total, internal, and external rotational ROM in both the hemiarthroplasty and TSA state. LEVEL OF EVIDENCE: Controlled laboratory study.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Fenômenos Biomecânicos , Cadáver , Humanos , Amplitude de Movimento Articular , Articulação do Ombro/cirurgia
17.
Arch Orthop Trauma Surg ; 142(9): 2271-2277, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34673999

RESUMO

INTRODUCTION: Femoral nerve block (FNB) is a routinely used regional analgesic technique for anterior cruciate ligament (ACL) reconstruction. One method to balance the analgesic effect and functional impairment of FNBs may be to control the concentration of local anesthetics utilized for the block. MATERIALS AND METHODS: Retrospective chart review was performed on 390 consecutive patients who underwent ACL reconstruction between June 2014 and May 2017. Patients were divided into those who received a standard (0.5%-bupivacaine) or low (0.1-0.125%-bupivacaine) concentration single-shot FNB performed with ultrasound guidance. Maximum postoperative VAS, Post-Anaesthesia Care Unit (PACU) time prior to discharge, need for additional 'rescue' block, and intravenous postoperative narcotic requirements were recorded. RESULTS: A total of 268 patients (28.4 ± 11.9 years) were included for final analysis, with 72 patients in the low-concentration FNB group and 196 patients receiving the standard concentration. There were no differences in the maximum postoperative VAS between the low (6.4 ± 2.5) and standard (5.7 ± 2.9) concentration groups (P = 0.08). Similarly, the time from PACU arrival to discharge was not different between groups (P = 0.64). A sciatic rescue block was needed in 22% of patients with standard-dose FNB compared to 30% of patients receiving the low-concentration FNB (P = 0.20). Patients with a hamstring autograft harvest were more likely to undergo a postoperative sciatic rescue block compared to a bone-patellar tendon autograft (P = 0.005), regardless of preoperative block concentration. Quadriceps activation was preserved with low-concentration blocks. CONCLUSIONS: Using 1/5th to 1/4th the standard local anesthetic concentration for preoperative femoral nerve block in ACL reconstruction did not significantly differ in peri-operative outcomes, PACU time, need for rescue blockade, or additional immediate opioid requirements. LEVEL OF EVIDENCE: III.


Assuntos
Nervo Femoral , Bloqueio Nervoso , Analgésicos Opioides , Anestésicos Locais , Bupivacaína , Humanos , Bloqueio Nervoso/métodos , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos
18.
Arthrosc Sports Med Rehabil ; 3(3): e781-e789, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34195645

RESUMO

PURPOSE: To evaluate the effect of a one-time dose of insulin or insulin-like growth factor 1 (IGF-1) on cellular proliferation and migration of subacromial bursa tissue (SBT) over time. METHODS: SBT was harvested from over the rotator cuff tendon in 4 consecutive patients undergoing primary arthroscopic rotator cuff repair. SBT was cultured for 3 weeks in complete media until reaching confluence. The culture dishes were stored in a humidified, low oxygen tension (5% CO2) incubator at 37°C. SBT of each patient underwent treatment with a one-time dose of insulin or IGF-1, whereas nontreated SBT served as a negative control. Cellular proliferation and migration were evaluated after 24, 48, 72, and 96 hours of incubation. SBT-derived cells migrated in the detection field were visualized using fluorescent microscopy. RESULTS: Cellular proliferation at 24, 48, 72, and 96 hours was 1.40 ± 0.27, 1.00 ± 0.20, 1.47 ± 0.31, and 1.68 ± 0.28 for IGF-1; 1.44 ± 0.24, 1.15 ± 0.27, 1.60 ± 0.36, and 1.61 ± 0.32 for insulin; and 1.51 ± 0.35, 1.29 ± 0.33, 1.53 ± 0.35, and 1.57 ± 0.38 for nontreated SBT. Untreated SBT demonstrated a significantly greater proliferation when compared with IGF-1 and insulin within the first 48 hours, although this effect was found to subside by 96 hours. Cellular migration at 24, 48, 72, and 96 hours was 575.7 ± 45.0, 641.6 ± 77.7, 728.3 ± 122.9, and 752.3 ± 114.5 for IGF-1; 528.4 ± 31.3, 592.5 ± 69.8, 664.2 ± 115.2, and 695.6 ± 148.2 for insulin; and 524.4 ± 41.9, 564.4 ± 49.8, 653.2 ± 81.5, and 685.7 ± 115.5 for nontreated SBT. Insulin showed no difference in migration at each timepoint compared to nontreated SBT (P > .05, respectively). CONCLUSIONS: Insulin and IGF-1 initially inhibit cellular proliferation of human SBT, although this effect was found to subside by 96 hours. Further, neither insulin nor IGF-1 changed the slope of cellular migration over time. However, each treatment group demonstrated a significant increase in cellular proliferation and migration. CLINICAL RELEVANCE: In the setting of biologic augmentation of rotator cuff repair, the compatibility and synergistic effect of insulin on human SBT is highly limited.

19.
J Shoulder Elbow Surg ; 30(11): 2620-2628, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33964426

RESUMO

BACKGROUND: Posterior glenoid wear remains a challenge in anatomic and reverse total shoulder arthroplasty (rTSA) because of an asymmetric erosion with altered retroversion. The purpose of this study was to assess glenoid morphology and evaluate the influence of acromial orientation in posterior glenoid erosion patterns by using 3-dimensional (3D) models. MATERIAL AND METHODS: Computed tomographic (CT) shoulder scans from 3 study centers of patients awaiting rTSA between 2017 and 2018 were converted into 3D models and analyzed by 2 observers. Morphology, orientation and greatest depth of erosion, inclination, current retroversion and premorbid retroversion, surface areas of the glenoid, and external acromial orientation and posterior acromial slope were assessed. Measurements were compared between wear patterns, glenoid erosion entities, and genders. RESULTS: In the complete cohort of 68 patients (63.8 ± 10.0 years; 19 female, 49 male), a mean of 85.9° (±22.2°) was observed for the glenoid erosion orientation. Additionally, a further distinct classification of the glenoid erosion as posterior-central (PC, n = 39), posterior-inferior (PI, n = 12), and posterior-superior (PS, n = 17) wear patterns was possible. These wear patterns significantly (P < .001) distinguished by erosion orientation (PC = 86.9° ± 12.0°, PI = 116.3° ± 10.3°, PS = 62.3° ± 18.9°). The greatest depth of erosion found was 7.3 ± 2.7 mm in PC wear patterns (PC vs. PI: P = .03; PC vs. PS: n.s.; PI vs. PS: n.s.). Overall, the observed erosion divided the glenoid surface into a paleoglenoid proportion of 48% (±11%) and a neoglenoid proportion of 52% (±12%). For the complete cohort, glenoid inclination was 85.4° (±6.6°), premorbid glenoid retroversion was 80.7° (±8.1°), and current glenoid retroversion was 73.4° (±7.4°), with an estimated increase of 6.9° (±6.0°). The mean external acromial orientation was 118.2° (±8.9°), and the mean posterior acromial slope was 107.2° (±9.6°). There were no further significant differences if parameters were compared by wear patterns, entities, and gender. CONCLUSION: Three significantly differently oriented wear patterns (posterior-superior, posterior-central, and posterior-inferior) were distinguished in shoulders demonstrating posterior wear on axillary imaging. No significant differences between the observed erosion patterns or any relevant correlations were found regarding the orientation of the acromion.


Assuntos
Artroplastia do Ombro , Osteoartrite , Articulação do Ombro , Acrômio , Feminino , Humanos , Masculino , Osteoartrite/cirurgia , Escápula/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
20.
J Shoulder Elbow Surg ; 30(9): 2177-2183, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33529773

RESUMO

BACKGROUND AND HYPOTHESIS: The treatment of periprosthetic joint infection is complicated by the presence of residual biofilm, which resists eradication owing to bacterial adherence to orthopedic implants. The purpose of this study was to compare Bactisure (Zimmer Biomet, Warsaw, IN, USA), povidone-iodine (Betadine), and chlorhexidine gluconate solution (Irrisept; Irrimax, Gainesville, FL, USA) in reducing biofilm formation of Staphylococcus aureus, Staphylococcus epidermidis, and Cutibacterium acnes inoculated on cobalt-chrome, titanium, and stainless steel disks, representing metals commonly used for shoulder arthroplasty. The hypothesis was that there would be no significant difference in biofilm reduction among the 3 topical adjuvants. METHODS: Strains of S aureus (ATCC 35556), S epidermidis (ATCC 35984), and C acnes (LMG 16711) were grown on cobalt-chrome, titanium, and stainless steel disks. For each strain, the disks were divided into 4 groups: (1) control, (2) povidone-iodine (Betadine), (3) chlorhexidine gluconate (Irrisept), and (4) Bactisure. Bacteria were grown on 5% sheep blood agar plates. Biofilm eradication was quantified using adenosine triphosphate bioluminescence and compared with controls 48 and 72 hours after implementation of the topical adjuvant. RESULTS: At 72 hours after implementation of the topical adjuvant, a statistically significant reduction in colony-forming units was observed for all topical adjuvants across all tested metals, as compared with their respective control. With respect to the topical adjuvants themselves, Bactisure more consistently demonstrated the most significant reduction in colony-forming units across all bacteria when the tested medium was adjusted for, with the exception of S aureus, which showed similar results to Betadine at 72 hours. CONCLUSION: By use of commonly encountered topical adjuvants on S aureus-, S epidermidis-, and C acnes-inoculated disks of various implant metals, a significant reduction in biofilm production was observed. Bactisure, a recent Food and Drug Administration-approved topical adjuvant, demonstrated the overall greatest efficacy of the agents studied.


Assuntos
Infecções Relacionadas à Prótese , Animais , Biofilmes , Próteses e Implantes , Infecções Relacionadas à Prótese/prevenção & controle , Ovinos , Staphylococcus aureus , Staphylococcus epidermidis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...