Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Circulation ; 146(21): 1581-1590, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-36121700

RESUMO

BACKGROUND: Long-term comparative outcomes after percutaneous coronary intervention (PCI) with everolimus-eluting stents and coronary artery bypass grafting (CABG) are limited in patients with multivessel coronary artery disease. METHODS: This prospective, multicenter, randomized controlled trial was conducted in 27 international heart centers and was designed to randomly assign 1776 patients with angiographic multivessel coronary artery disease to receive PCI with everolimus-eluting stents or CABG. After inclusion of 880 patients (438 in the PCI group and 442 in the CABG group) between July 2008 and September 2013, the study was terminated early because of slow enrollment. The primary end point was the composite of death from any cause, myocardial infarction, or target vessel revascularization. RESULTS: During a median follow-up of 11.8 years (interquartile range, 10.6-12.5 years; maximum, 13.7 years), the primary end point occurred in 151 patients (34.5%) in the PCI group and 134 patients (30.3%) in the CABG group (hazard ratio [HR], 1.18 [95% CI, 0.88-1.56]; P=0.26). No significant differences were seen in the occurrence of a safety composite of death, myocardial infarction, or stroke between groups (28.8% and 27.1%; HR, 1.07 [95% CI, 0.75-1.53]; P=0.70), as well as the occurrence of death from any cause (20.5% and 19.9%; HR, 1.04 [95% CI, 0.65-1.67]; P=0.86). However, spontaneous myocardial infarction (7.1% and 3.8%; HR, 1.86 [95% CI, 1.06-3.27]; P=0.031) and any repeat revascularization (22.6% and 12.7%; HR, 1.92 [95% CI, 1.58-2.32]; P<0.001) were more frequent after PCI than after CABG. CONCLUSIONS: In patients with multivessel coronary artery disease, there were no significant differences between PCI and CABG in the incidence of major adverse cardiac events, the safety composite end point, and all-cause mortality during the extended follow-up. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifiers: NCT05125367 and NCT00997828.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Everolimo/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Stents Farmacológicos/efeitos adversos , Seguimentos , Estudos Prospectivos , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Resultado do Tratamento
2.
Cardiol J ; 28(1): 136-149, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-31565793

RESUMO

Coronary artery disease (CAD) is currently the leading cause of death globally, and the prevalence of this disease is growing more rapidly in the Asia-Pacific region than in Western countries. Although the use of metal coronary stents has rapidly increased thanks to the advancement of safety and efficacy of newer generation drug eluting stent (DES), patients are still negatively affected by some the inherent limitations of this type of treatment, such as stent thrombosis or restenosis, including neoatherosclerosis, and the obligatory use of dual antiplatelet therapy (DAPT) with unknown optimal duration. Drug-coated balloon (DCB) treatment is based on a leave-nothing-behind concept and therefore it is not limited by stent thrombosis and long-term DAPT; it directly delivers an anti-proliferative drug which is coated on a balloon after improving coronary blood flow. At present, DCB treatment is recommended as the first-line treatment option in metal stent-related restenosis linked to DES and bare metal stent. For de novo coronary lesions, the application of DCB treatment is extended further, for conditions such as small vessel disease, bifurcation lesions, and chronic total occlusion lesions, and others. Recently, several reports have suggested that fractional flow reserve guided DCB application was safe for larger coronary artery lesions and showed good long-term outcomes. Therefore, the aim of these recommendations of the consensus group was to provide adequate guidelines for patients with CAD based on objective evidence, and to extend the application of DCB to a wider variety of coronary diseases and guide their most effective and correct use in actual clinical practice.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Reserva Fracionada de Fluxo Miocárdico , Preparações Farmacêuticas , Angioplastia Coronária com Balão/instrumentação , Ásia , Materiais Revestidos Biocompatíveis , Consenso , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Humanos , Resultado do Tratamento
3.
Int J Cardiol Heart Vasc ; 31: 100605, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32953969

RESUMO

BACKGROUND: The COMBO stent is a biodegradable-polymer sirolimus-eluting stent with endothelial progenitor cell capture technology for faster endothelialization. OBJECTIVE: We analyzed COMBO stent outcomes in relation to bleeding risk using the PARIS bleeding score. METHODS: MASCOT was an international registry of all-comers undergoing attempted COMBO stent implantation. We stratified patients as low bleeding-risk (LBR) for PARIS score ≤ 3 and intermediate-to-high (IHBR) for score > 3 based on baseline age, body mass index, anemia, current smoking, chronic kidney disease and need for triple therapy. Primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, myocardial infarction (MI) not clearly attributed to a non-target vessel or clinically-driven target lesion revascularization (TLR). Bleeding was adjudicated using the Bleeding Academic Research Consortium (BARC) definition. Dual antiplatelet therapy (DAPT) cessation was independently adjudicated. RESULTS: The study included 56% (n = 1270) LBR and 44% (n = 1009) IHBR patients. Incidence of 1-year TLF was higher in IHBR patients (4.1% vs. 2.6%, p = 0.047) driven by cardiac death (1.7% vs. 0.7%, p = 0.029) with similar rates of MI (1.8% vs. 1.1%, p = 0.17), TLR (1.5% vs. 1.6%, p = 0.89) and definite/ probable stent thrombosis (1.2% vs. 0.6%, p = 0.16). Incidence of 1-year major BARC 3 or 5 bleeding was significantly higher in IHBR patients (2.3% vs. 0.9%, p = 0.0094), as was the incidence of DAPT cessation (29.3% vs. 22.8%, p < 0.01), driven by physician-guided discontinuation. CONCLUSIONS: Patients with intermediate-to-high PARIS bleeding risk in the MASCOT registry experienced greater incidence of 1-year TLF, major bleeding and DAPT cessation than LBR patients, without significant differences in stent thrombosis.

4.
ASEAN Heart J ; 24: 10, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28042584

RESUMO

ST-elevation myocardial infarction (STEMI) in situs inversus dextrocardia is a rare combination and poses many challenges in terms of diagnosis and management. These include the early detection of dextrocardia as well as the interpretation of the ECG. In addition, percutaneous coronary intervention could be challenging in the setting of dextrocardia because of diffi culty in cannulating the coronary arteries, selection of catheters, catheter manipulation, image acquisition and interpretation.

5.
Cardiovasc Intervent Radiol ; 29(2): 230-4, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16252078

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) is a trusted method of sizing atrial septal defect (ASD) prior to percutaneous closure but is invasive, uncomfortable, and may carry a small risk of morbidity and mortality. Magnetic resonance imaging (MRI) may be useful non-invasive alternative in such patients who refuse or are unable to tolerate TEE and may provide additional information on the shape of the A0SD. PURPOSE: To validate the accuracy of ASD sizing by MRI compared with TEE. METHOD: Twelve patients (mean age 30 years; range 11-60 years) scheduled for ASD closure underwent TEE, cine balanced fast field echo MRI (bFFE-MRI) in four-chamber and sagittal views and phase-contrast MRI (PC-MRI) with reconstruction using the two orthogonal planes of T2-weighted images as planning. The average of the three longest measurements for all imaging modalities was calculated for each patient. RESULTS: Mean maximum ASD length on TEE was 18.8 +/- 4.6 mm, mean length by bFFE-MRI was 20.0 +/- 5.0 mm, and mean length by PC-MRI was 18.3 +/- 3.6 mm. The TEE measurement was significantly correlated with the bFFE-MRI and PC-MRI measurements (Pearson r = 0.69, p = 0.02 and r = 0.59, p = 0.04, respectively). The mean difference between TEE and bFFE-MRI measurements was -1.2mm (95% CI: -3.7, 1.3) and between TEE and PC-MRI was 0.5 mm (95% CI: -1.9, 2.9). Bland-Altman analysis also determined general agreement between both MRI methods and TEE. The ASDs were egg-shaped in two cases, circular in 1 patient and oval in the remaining patients. CONCLUSION: ASD sizing by MRI using bFFE and phase-contrast protocols correlated well with TEE estimations. PC-MRI provided additional information on ASD shapes and proximity to adjacent structures.


Assuntos
Comunicação Interatrial/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Criança , Ecocardiografia Transesofagiana , Feminino , Comunicação Interatrial/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos