1.
J Vasc Access ; 16 Suppl 10: S50-2, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26349866

RESUMO

BACKGROUND: The number of dialysis patients in Japan has amounted to approximately 310,000. Most of the patients undergo hemodialysis. The reason why they can undergo hemodialysis is because maintaining and managing vascular access (VA) has improved. Recently, thanks to the progress of medical equipment, a variety of monitoring systems have been developed. It is important to make good use of these monitoring systems. RESULTS: In our hospital, we have been monitoring with an ultrasonic device and HD02. We measure blood flow of brachial artery with an ultrasonic device during nondialysis treatment. We examine real blood flow and blood recirculation with HD02 and evaluate the function of VA during dialysis. CONCLUSIONS: In order to provide good dialysis care, good use of monitoring devices of VA is significant.


Assuntos
Derivação Arteriovenosa Cirúrgica , Artéria Braquial/cirurgia , Hospitais , Técnicas de Diluição do Indicador , Monitorização Fisiológica , Diálise Renal , Grau de Desobstrução Vascular , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Velocidade do Fluxo Sanguíneo , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/fisiopatologia , Débito Cardíaco , Desenho de Equipamento , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Técnicas de Diluição do Indicador/instrumentação , Japão , Monitorização Fisiológica/instrumentação , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
2.
Contrib Nephrol ; 186: 13-20, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26283555

RESUMO

The two reasons that patients desire buttonhole cannulation are avoidance of puncture pain and extension of arteriovenous fistula life. Despite the desire to receive buttonhole cannulation by many patients, medical staff at most local hemodialysis facilities tend to hesitate to implement the cannulation method. This method is used on patients in the dialysis unit at Saitama Medical Center, but tends to be discontinued for those patients upon their transfer to local hemodialysis facilities. Medical staff members of one local hemodialysis facility report the percentage of patients on the buttonhole method was 53% in 2007, but that it sharply decreased to 17% in 2013. Hesitation by local hemodialysis facilities to adopt the buttonhole method is due to, but not limited to, several factors. These factors include the frequently occurring trampoline effect, the difficulty of removing scabs, formation of a false buttonhole track, and the pain from insertion of a dull needle. Perceived differences in the value of buttonhole cannulation may potentially affect communication between patients and staff in local hemodialysis facilities.


Assuntos
Instituições de Assistência Ambulatorial , Derivação Arteriovenosa Cirúrgica , Atitude do Pessoal de Saúde , Cateterismo Periférico/métodos , Conhecimentos, Atitudes e Prática em Saúde , Falência Renal Crônica/terapia , Satisfação do Paciente , Diálise Renal/métodos , Humanos