Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cureus ; 15(8): e43103, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37692606

RESUMO

Background Animal models of distributive hypotension and resuscitation allow the assessment of hemodynamic monitoring modalities and resuscitation strategies. The fluid-first paradigm for resuscitation is currently being challenged with clinical trials. In this investigation, venous return and perfusion are assessed, and full hemodynamics are characterized, in a porcine model of endotoxemic hypotension with and without fluid pre-loading. Methods Two groups of six pigs had the induction of standardized endotoxemic hypotension ("critical hypotension"). Group 1 underwent four 10 cc/kg crystalloid boluses, and Group 2 was not fluid pre-resuscitated. Both groups underwent progressive norepinephrine (NE) up-titration to 0.25 mcg/kg/minute over 30 minutes. Vital signs, central parameters, and laboratory values were obtained at baseline, "critical hypotension," after each bolus and during NE administration. Results Endotoxemia decreased the systemic vascular resistance (SVR) in Group 1 (1031±106 dyn/s/cm-5 versus 738±258 dyn/s/cm-5; P=0.03) and Group 2 (1121±196 dyn/s/cm-5 versus 759±342 dyn/s/cm-5; P=0.003). In Group 1, the four fluid boluses decreased heart rate (HR), pulmonary capillary wedge pressure (PCWP), and central venous pressure (CVP) (P<0.05). No changes were observed in blood pressure, cardiac output (CO), or lactate. NE up-titration increased HR in Group 1 and decreased CVP in both groups. Higher final CVP (11 {3} versus 4 {4} mmHg; P=0.01) and PCWP (5 {1} versus 2 {2} mmHg; P=0.005) values were observed in Group 1 relative to Group 2, reflecting increased venous return. Conclusions Porcine endotoxemic hypotension and resuscitation were robustly characterized. In this model, fluid loading improved venous return with NE, though perfusion (CO) was preserved by increased NE-induced chronotropy.

2.
J Am Coll Surg ; 236(2): 294-304, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36648257

RESUMO

BACKGROUND: Cardiac output (CO) is a valuable proxy for perfusion, and governs volume responsiveness during resuscitation from distributive shock. The underappreciated venous system has nuanced physiology that confers valuable hemodynamic information. In this investigation, deconvolution of the central venous waveform by the fast Fourier transformation (FFT) algorithm is performed to assess its ability to constitute a CO surrogate in a porcine model of endotoxemia-induced distributive hypotension and resuscitation. STUDY DESIGN: Ten pigs were anesthetized, catheterized, and intubated. A lipopolysaccharides infusion protocol was used to precipitate low systemic vascular resistance hypotension. Four crystalloid boluses (10 cc/kg) were then given in succession, after which heart rate, mean arterial pressure, thermodilution-derived CO, central venous pressure (CVP), and the central venous waveform were collected, the last undergoing fast Fourier transformation analysis. The amplitude of the fundamental frequency of the central venous waveform's cardiac wave (f0-CVP) was obtained. Heart rate, mean arterial pressure, CVP, f0-CVP, and CO were plotted over the course of the boluses to determine whether f0-CVP tracked with CO better than the vital signs, or than CVP itself. RESULTS: Distributive hypotension to a 25% mean arterial pressure decrement was achieved, with decreased systemic vascular resistance (mean 918 ± 227 [SD] dyne/s/cm-5 vs 685 ± 180 dyne/s/cm-5; p = 0.038). Full hemodynamic parameters characterizing this model were reported. Slopes of linear regression lines of heart rate, mean arterial pressure, CVP, f0-CVP, and CO were -2.8, 1.7, 1.8, 0.40, and 0.35, respectively, demonstrating that f0-CVP values closely track with CO over the 4-bolus range. CONCLUSIONS: Fast Fourier transformation analysis of the central venous waveform may allow real-time assessment of CO during resuscitation from distributive hypotension, possibly offering a venous-based approach to clinical estimation of volume responsiveness.


Assuntos
Endotoxemia , Hipotensão , Suínos , Animais , Débito Cardíaco/fisiologia , Hemodinâmica , Hipotensão/etiologia , Hipotensão/terapia , Ressuscitação/métodos
3.
Anesthesiology ; 134(4): 607-616, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33635950

RESUMO

BACKGROUND: Measuring fluid status during intraoperative hemorrhage is challenging, but detection and quantification of fluid overload is far more difficult. Using a porcine model of hemorrhage and over-resuscitation, it is hypothesized that centrally obtained hemodynamic parameters will predict volume status more accurately than peripherally obtained vital signs. METHODS: Eight anesthetized female pigs were hemorrhaged at 30 ml/min to a blood loss of 400 ml. After each 100 ml of hemorrhage, vital signs (heart rate, systolic blood pressure, mean arterial pressure, diastolic blood pressure, pulse pressure, pulse pressure variation) and centrally obtained hemodynamic parameters (mean pulmonary artery pressure, pulmonary capillary wedge pressure, central venous pressure, cardiac output) were obtained. Blood volume was restored, and the pigs were over-resuscitated with 2,500 ml of crystalloid, collecting parameters after each 500-ml bolus. Hemorrhage and resuscitation phases were analyzed separately to determine differences among parameters over the range of volume. Conformity of parameters during hemorrhage or over-resuscitation was assessed. RESULTS: During the course of hemorrhage, changes from baseline euvolemia were observed in vital signs (systolic blood pressure, diastolic blood pressure, and mean arterial pressure) after 100 ml of blood loss. Central hemodynamic parameters (mean pulmonary artery pressure and pulmonary capillary wedge pressure) were changed after 200 ml of blood loss, and central venous pressure after 300 ml of blood loss. During the course of resuscitative volume overload, changes were observed from baseline euvolemia in mean pulmonary artery pressure and central venous pressure after 500-ml resuscitation, in pulmonary capillary wedge pressure after 1,000-ml resuscitation, and cardiac output after 2,500-ml resuscitation. In contrast to hemorrhage, vital sign parameters did not change during over-resuscitation. The strongest linear correlation was observed with pulmonary capillary wedge pressure in both hemorrhage (r2 = 0.99) and volume overload (r2 = 0.98). CONCLUSIONS: Pulmonary capillary wedge pressure is the most accurate parameter to track both hemorrhage and over-resuscitation, demonstrating the unmet clinical need for a less invasive pulmonary capillary wedge pressure equivalent.


Assuntos
Soluções Cristaloides/administração & dosagem , Hidratação/efeitos adversos , Hemodinâmica , Hemorragia/fisiopatologia , Animais , Volume Sanguíneo , Modelos Animais de Doenças , Feminino , Ressuscitação , Suínos , Sinais Vitais
4.
Anesth Analg ; 126(1): 120-126, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29135593

RESUMO

BACKGROUND: Radial arterial cannulation is most commonly done using palpation, but the use of ultrasound has increased the cannulation success rate. This improvement, albeit significant, has not led to a very high success rate especially in trainees. A modified ultrasound technique for vascular cannulation (dynamic needle tip positioning) has been described for peripheral venous cannulation. We therefore assessed the success rate of this technique compared to the palpation technique for radial artery cannulation in adult surgical patients. METHODS: We enrolled patients who were having nonemergent operations that required a radial arterial catheter for intraoperative monitoring. Patients were randomized to either palpation or dynamic needle tip positioning technique. Arterial cannulation was performed by anesthesia residents or faculty members. The primary end point was successful cannulation on the first pass. Secondary end points were overall 5-minute success rate and number of attempts within 5 minutes. RESULTS: Two hundred sixty patients were evaluated. The first-pass success rate was 83% in the dynamic needle tip positioning technique group (n = 132) and 48% in the palpation group (n = 128; P < .001); relative risk was 2.5; 95% confidence interval, 1.7-3.6. The overall 5-minute success rate was 89% in the dynamic needle tip positioning technique group compared to 65% in the palpation group (P < .001), relative risk was 2.4; 95% confidence interval, 1.2-1.6. The number of skin puncture attempts was significantly more in the palpation group (P < .001). The median cannulation times and interquartile ranges were 81.5 (61-122) seconds in the dynamic needle tip positioning and 76 (48-175) seconds (P = .7) in the palpation group. CONCLUSIONS: The use of the ultrasound-guided dynamic needle tip positioning technique increased the first and overall success rates compared to palpation in anesthesia residents and faculty members.


Assuntos
Cateterismo Periférico/métodos , Agulhas , Palpação/métodos , Artéria Radial/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Cateterismo Periférico/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Palpação/instrumentação , Estudos Prospectivos , Artéria Radial/cirurgia , Ultrassonografia de Intervenção/instrumentação
5.
J Clin Anesth ; 27(2): 164-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25573265

RESUMO

A 35-year-old man had symptomatic hyperammonemia and normal liver function after repeat kidney transplantation. He presented with gastrointestinal symptoms, which quickly progressed to altered mental status. Therapy was instituted to clear the ammonia, but the ammonia level continued to rise. Eventually, the patient became unresponsive, and an emergent computed tomographic scan showed cerebral herniation. Urine acids and serum organic acids were not diagnostic of any urea cycle disorder. Histology did not reveal a clear etiology for the hyperammonemia.


Assuntos
Hiperamonemia/etiologia , Transplante de Rim/efeitos adversos , Adulto , Edema Encefálico/diagnóstico por imagem , Edema Encefálico/etiologia , Encefalocele/diagnóstico por imagem , Encefalocele/etiologia , Evolução Fatal , Humanos , Rim/anormalidades , Masculino , Reoperação/efeitos adversos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...