Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 10(1): 11491, 2020 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-32661264

RESUMO

Early detection of compromised circulation is essential for postoperative monitoring of free flap. Hourly clinical check-ups such as inspection and palpation still result in a delay in detection. Conversely, optical reflection and temperature measurement are useful alternatives for detecting blood circulation. However, conventional methods that verify ischemia and congestion within a short period have not been reported. In this study, we measured short-term changes in optical reflection and temperature in a rat flap using a wearable flexible sensor probe previously developed in our laboratory. Five ischemia and five congestion groin flap models were measured using a sensor probe and reference devices. Curve fitting was performed on transition signals to evaluate changes in signals and their time constants. The optical reflection signal decreased after venous ligation and increased after arterial ligation. The parameters of the fitted curves indicate a significant difference between congestion and ischemia at p < 0.01 (probability value), which was detected within a few minutes after ligation. However, insufficient significance was observed in the temperature signal. Our method gives supporting information to verify ischemia and congestion, and has the potential to rapidly detect compromised circulation.


Assuntos
Isquemia/diagnóstico , Monitorização Fisiológica/métodos , Doenças Vasculares/diagnóstico , Dispositivos Eletrônicos Vestíveis , Animais , Retalhos de Tecido Biológico/patologia , Retalhos de Tecido Biológico/fisiologia , Humanos , Isquemia/sangue , Isquemia/fisiopatologia , Microcirurgia/efeitos adversos , Período Pós-Operatório , Ratos , Fluxo Sanguíneo Regional/fisiologia , Temperatura , Doenças Vasculares/sangue , Doenças Vasculares/fisiopatologia
2.
Dent Mater J ; 36(4): 408-414, 2017 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-28302944

RESUMO

The aim of this study was to investigate properties of atelocollagen/gelatin complexes (AC/Gel) and their characteristics of sustained statin release, to assess the utility of AC/Gel. AC/Gel were prepared by changing the mixing ratio of AC (0 to 40% of AC). Analysis of spectra of fluvastatin (Flu), gelatin (Gel), and Flu with Gel complex using a Fourier transform-infrared spectrometer indicates that Flu was bound to Gel through a bond involving the carboxyl and amino groups. Evaluation of characteristics of sustained release of Flu from the AC/Gel using an ultraviolet-visible spectrophotometer showed that the release rate of Flu decreased with increasing the AC content. The histological evaluation using of Sprague-Dawley rats suggest that, unlike the pure Gel sponge, the AC/Gel was not absorbed in an early stage. Therefore, the present study showed that sustained Flu release can be controlled by using an AC/Gel, suggesting the utility of this composite material.


Assuntos
Ácidos Graxos Monoinsaturados , Gelatina , Indóis , Animais , Sistemas de Liberação de Medicamentos , Fluvastatina , Inibidores de Hidroximetilglutaril-CoA Redutases , Teste de Materiais , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...