We show the operation of an optically pumped magnetometer array in a 50 µT magnetic field. The various components for a fully optical and non-magnetic detector unit were constructed and evaluated, from which a prototype unit was assembled with fiber coupled electronics. In this unit the magnetometers were operated using the intensity modulated method and heated with an off-resonant laser. Calculations on the temperature distribution were used to design the magnetometer array. Different magnetometers in such a detector unit were characterized and showed identical performance. Without applying noise reduction schemes, the obtained magnetic field resolution is a factor 2.5 above the shot noise level down to frequencies of about 7 Hz.
RESUMO
Hybrids of koi, Cyprinus carpio x crucian carp, Carassius carassius and koi x goldfish, Carassius auratus, proved to be susceptible to koi herpesvirus (KHV, syn. CyHV-3) and developed KHV disease (KHVD). While hybrids of koi x goldfish were partly resistant to mortality following infection by immersion, most koi x crucian carp hybrids died after bath infection. KHV DNA was detected in dead fish but also in all surviving animals by different polymerase chain reactions (PCRs). According to these results, hybrid crossbreeding does not seem to prevent severe losses associated with KHV in terms of inducing KHVD. The present study showed severe losses after a waterborne KHV infection of between 35% and 100% in koi x goldfish and koi x crucian carp hybrids as well as in SPF carp.