Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Gynaecol Obstet ; 146(2): 250-256, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31131885

RESUMO

OBJECTIVE: To evaluate the association between birthweight and maternal heart rate (MHR) or heart rate variability (HRV) under resting conditions at 20-24 gestational weeks and 34 weeks or later (34+ weeks). METHODS: Data were retrospectively reviewed from the Safe Passage Study, a prospective longitudinal cohort study of alcohol use in pregnancy and birth outcomes in Cape Town, South Africa, between August 2007 and January 2015. Using custom-designed software, MHR and indicators of HRV were obtained from the recorded maternal electrocardiograms and compared with birthweight and z-scores of birthweight adjusted for gestation and gender. RESULTS: Data from 5655 women were included. MHR increased from 84.6 bpm at 20-24 weeks to 88.3 bpm at 34+ weeks. Increasing MHR from 70-80 to 80-90 and 90-100 bpm at 20-24 weeks was associated with increasing birthweight from 2940 to 2998 and 3032 g, respectively (P<0.05). MHR and HRV contributed 29% to the variability associated with birthweight, whereas maternal body mass index at recruitment contributed 44%. Similar associations were observed for MHR at 34+ weeks. CONCLUSION: The observed association of low maternal heart rate with birthweight might help to identify pregnancies at risk of poor fetal growth.


Assuntos
Peso ao Nascer/fisiologia , Desenvolvimento Fetal/fisiologia , Frequência Cardíaca/fisiologia , Adolescente , Adulto , Índice de Massa Corporal , Eletrocardiografia , Feminino , Retardo do Crescimento Fetal/etiologia , Idade Gestacional , Humanos , Estudos Longitudinais , Gravidez , Estudos Prospectivos , Estudos Retrospectivos , África do Sul , Adulto Jovem
2.
Med Eng Phys ; 48: 181-187, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28734875

RESUMO

This study explores the feasibility of prospectively assessing infant dehydration using four non-invasive, optical sensors based on the quantitative and objective measurement of various clinical markers of dehydration. The sensors were investigated to objectively and unobtrusively assess the hydration state of an infant based on the quantification of capillary refill time (CRT), skin recoil time (SRT), skin temperature profile (STP) and skin tissue hydration by means of infrared spectrometry (ISP). To evaluate the performance of the sensors a clinical study was conducted on a cohort of 10 infants (aged 6-36 months) with acute gastroenteritis. High sensitivity and specificity were exhibited by the sensors, in particular the STP and SRT sensors, when combined into a fusion regression model (sensitivity: 0.90, specificity: 0.78). The SRT and STP sensors and the fusion model all outperformed the commonly used "gold standard" clinical dehydration scales including the Gorelick scale (sensitivity: 0.56, specificity: 0.56), CDS scale (sensitivity: 1.0, specificity: 0.2) and WHO scale (sensitivity: 0.13, specificity: 0.79). These results suggest that objective and quantitative assessment of infant dehydration may be possible using the sensors investigated. However, further evaluation of the sensors on a larger sample population is needed before deploying them in a clinical setting.


Assuntos
Desidratação/diagnóstico , Dispositivos Ópticos , Pré-Escolar , Desidratação/complicações , Estudos de Viabilidade , Feminino , Gastroenteropatias/complicações , Humanos , Lactente , Masculino
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 5537-40, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26737546

RESUMO

Dehydration resulting from acute diarrhea is one of the leading causes of infant mortality in the developing world. Safe assessment of an infant's hydration level is essential to determine appropriate clinical intervention strategies. However, clinical hydration scales, which are the current gold standard for non-invasive hydration assessment, are often unreliable in lower resource settings. This study presents the development and testing of non-invasive, optical sensors for the objective assessment of dehydration based on the quantitative measurement of skin recoil time, capillary refill time and skin temperature. The results obtained have demonstrated the basic feasibility of using optical sensors for the objective assessment of dehydration. However, several challenges must be overcome before these sensors can be applied in a clinical setting.


Assuntos
Desidratação , Diarreia , Hidratação , Recursos em Saúde , Humanos , Lactente , Projetos de Pesquisa
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 1271-4, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26736499

RESUMO

The clinical assessment of dehydration is highly subjective and requires experienced and highly trained clinical personnel. At present no objective method for quantitatively determining an individual's dehydration status exists. The aim of this study is to address this deficiency by presenting the development and testing of a novel diagnostic tool for dehydration detection based on infrared spectrometry. Laboratory testing and two clinical studies were conducted to evaluate the efficacy of the device in both adults and infants. The results were promising for the infant study with a clear trend exhibited. However, a number of challenges must be overcome before this sensor can be applied in a clinical setting.


Assuntos
Espectrofotometria Infravermelho , Desidratação , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...