Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 10(1): 7007, 2020 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-32332815

RESUMO

Proton and ion beam therapy has proven to benefit tumour control with lower side-effects, mostly in paediatrics. Here we demonstrate a feasible technique for proton and ion beam spectroscopy (PIBS) capable of determining the elemental compositions of the irradiated tissues during particle therapy. This follows the developments in prompt gamma imaging for online range verification and the inheritance from prompt gamma neutron activation analysis. Samples of water solutions were prepared to emulate varying oxygen and carbon concentrations. The irradiation of those samples and other tissue surrogate inserts by protons and ion beams under clinical conditions clearly showed a logarithmic relationship between the target elemental composition and the prompt gamma production. This finding is in line with the known logarithmic dependence of the pH with the proton molar concentration. Elemental concentration changes of 1% for calcium and 2% for oxygen in adipose, brain, breast, liver, muscle and bone-related tissue surrogates were clearly identified. Real-time in vivo measurements of oxygen, carbon and calcium concentrations will be evaluated in a pre-clinical and clinical environment. This technique should have an important impact in the assessment of tumour hypoxia over the course of several treatment fractions and the tracking of calcifications in brain metastases.


Assuntos
Cálcio/química , Carbono/química , Íons/química , Oxigênio/química , Prótons , Humanos
2.
Phys Med Biol ; 65(9): 095010, 2020 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-32092707

RESUMO

The physical range uncertainty limits the exploitation of the full potential of charged particle therapy. In this work, we face this issue aiming to measure the absolute Bragg peak position in the target. We investigate p, 4He, 12C and 16O beams accelerated at the Heidelberg Ion-Beam Therapy Center. The residual range of the primary 12C ions is correlated to the energy spectrum of the prompt gamma radiation. The prompt gamma spectroscopy method was demonstrated for proton beams accelerated by cyclotrons and is developed here for the first time for heavier ions accelerated by a synchrotron. We develop a detector system that includes (i) a spectroscopic unit based on cerium(III) bromide and bismuth germanium oxide scintillating crystals, (ii) a beam trigger based on an array of scintillating fibers and (iii) a data acquisition system based on a FlashADC. We test the system in two different scenarios. In the first series of experiments, we detect and identify 19 independent spectral lines over a wide gamma energy spectrum in the presence of the four ion species for different targets, including a water target with a titanium insert. In the second series of experiments, we introduce a collimator aiming to relate the spectral information to the range of the primary particles. We perform extensive measurements for a 12C beam and demonstrate submillimetric precision for the measurement of its Bragg peak position in the experimental setup. The features of the energy and time spectra for gamma radiation induced by p, 4He and 16O are investigated upstream and downstream from the Bragg peak position. We conclude the analysis by extrapolating the required future developments, which would be needed to achieve range verification with a 2 mm accuracy during a single fraction delivery of [Formula: see text] physical dose.


Assuntos
Carbono/química , Terapia com Prótons/métodos , Síncrotrons , Carbono/uso terapêutico , Método de Monte Carlo , Terapia com Prótons/instrumentação , Espectrometria gama/métodos
3.
Med Phys ; 46(8): 3615-3626, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31087394

RESUMO

PURPOSE: The presence of range uncertainties hinders the exploitation of the full potential of charged particle therapy. Several range verification techniques have been proposed to mitigate this limitation. Prompt gamma spectroscopy (PGS) is among the most promising solutions for online and in vivo range verification. In this work, we present the experimental results of the detection of prompt gamma radiation, induced by 4 He beams at the Heidelberg Ion-Beam Therapy Center (HIT). The results were obtained, using a spectroscopic unit of which the design has been optimized using Monte Carlo simulations. METHODS: The spectroscopic unit is composed by a primary cerium bromide (CeBr 3 ) crystal surrounded by a secondary bismuth germanate (BGO) crystal for anticoincidence detection (AC). The digitalization of the signals is performed with an advanced FADC/FPGA system. The 4 He beams at clinical energies and intensities are delivered to multiple targets in the experimental cave at the HIT. We analyze the production of prompt gamma on oxygen and carbon targets, as well as high Z materials such as titanium and aluminum. The quantitative analysis includes a systematic comparison of the signal-to-noise ratio (SNR) improvement for the spectral lines when introducing the AC detection. Moreover, the SNR improvement could provide a reduction of the number of events required to draw robust conclusions. We perform a statistic analysis to determine the magnitude of such an effect. RESULTS: We present the energy spectra detected by the primary CeBr 3 and the secondary BGO. The combination of these two detectors leads to an average increase of the signal-to-noise ratio by a factor 2.1, which confirms the Monte Carlo predictions. The spectroscopic unit is capable of detecting efficiently the discrete gamma emission over the full energy spectrum. We identify and analyze 19 independent spectral lines in an energy range spacing from E γ = 0.718  MeV to E γ = 6.13  MeV. Moreover, when introducing the AC detection, the number of events required to determine robustly the intensity of the discrete lines decreases. Finally, the analysis of the low-energy reaction lines determines whether a thin metal insert is introduced in the beam direction. CONCLUSIONS: This work provides the experimental characterization of the spectroscopy unit in development for range verification through PGS at the HIT. Excellent performances have been demonstrated over the full prompt gamma energy spectrum with 4 He beams at clinical energies and intensities.


Assuntos
Cério/química , Raios gama , Hélio/uso terapêutico , Contagem de Cintilação/instrumentação , Análise Espectral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...